• Title/Summary/Keyword: Liquid storage tank

Search Result 210, Processing Time 0.028 seconds

Earthquake Response Analysis for 2-D Fluid-Structure-Soil Systems (2차원 유체-구조뭍-지반계의 지진응답해석)

  • 윤정방;장수혁;김재민;홍선기
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.289-296
    • /
    • 2000
  • This paper presents a method of seismic analysis for a 2-D fluid-structure-soil interaction systems. With this method, the fluid can be modeled by spurious free 4-node displacement-based fluid elements which use rotational penalty and mass projection technique in conjunction with the one point reduced integration scheme to remove the spurious zero energy modes. The structure and the near-field soil are discretized by the standard 2-D finite elements, while the unbounded far-field soil is represented by the dynamic infinite elements in the frequency domain. Since this method directly models the fluid-structure-soil interaction systems, it can be applied to the dynamic analysis of a 2-D liquid storage structure with complex geometry. Finally, results of seismic analyses are presented for a spent fuel storage tank embedded in a layered half-space and a massive concrete dam on a layered half-space.

  • PDF

Earthquake Response Analysis for 2-D Fluid-Structure-Soil Systems (2차원 유체-구조물-지반계의 지진응답해석)

  • 윤정방;장수혁;김재민
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.132-137
    • /
    • 2001
  • This paper presents a method of seismic analysis for a 2-D fluid-structure-soil interaction systems. With this method, the fluid can be modeled by spurious free 4-node displacement-based fluid elements which use rotational penalty and mass projection technique in conjunction with the one point reduced integration scheme to remove the spurious zero energy modes. The structure and the near-field soil are discretized by the standard 2-D finite elements, while the unbounded far-field soil is represented by the dynamic infinite elements in the frequency domain. Since this method directly models the fluid-structure-soil interaction systems, it can be applied to the dynamic analysis of a 2-D liquid storage structure with complex geometry. Finally, results of seismic analyses are presented for a spent fuel storage tank embedded in a layered half-space and a massive concrete dam on a layered half-space.

  • PDF

The effects of low temperature storage and aging of Jeot-kal on the microbial counts and microflora (젓갈의 숙성 및 저온 저장이 미생물 균수 및 균총에 미치는 영향)

  • Hong, Yeun;Kim, Jeong-Hee;Ahn, Byung-Hak;Cha, Seong-Kwan
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.1341-1349
    • /
    • 2000
  • The addition of 5% NaCI to standard plate count (SPC) and bromcresol purple (BCP) agar showed the highest viable cell counts for Jeot-kal samples. The use of 15% glycerol as cryoprotectant showed the highest microbial survival rate at both temperatures, $-20^{\circ}C$ and $-170^{\circ}C$, and on both colony count media, SPC and BCP. During the aging, the pH of Bajirak Jogae-Jeot (fermented clam) decreased from 6.8 to 5.0. Crude protein content was 10% for Bajirak Jogae-Jeot and $6{\sim}7%$ for Myeolchi-Jeot (fermented anchovy). Microbial population of Bajirak Jogae-Jeot was $10^9\;CFU/g$ after 4 weeks of aging, but was only $10^{3-5}\;CFU/g$ in the case of Myeolchi-Jeot. The proportion of Gram positive and catalase negative bacteria in Bajirak Jogae-Jeot increased drastically during the 4 weeks of aging, which showed typical lactic bacterial fermentation. After 2 years' storage of Jeot-kal in liquid nitrogen tank, the cell counts of total aerobic or lactic bacteria were decreased, resulting in about 10% survival rate. Microbial floral change of Jeot-kal was also investigated. In the case of Bajirak Jogae-jeot, the ratio of rod to cocci and that of Gram negative to positive increased after liquid nitrogen storage. But, rod to cocci ratio of Myeolchi-jeot decreased after liquid nitrogen storage. The ratio of yeasts decreased in both cases after storage.

  • PDF

A Survey on Present Conditions of Operational Management in the Animal Manure Public Resource Center (가축분뇨 공동자원화시설 관리운영 실태조사)

  • Kim, Doo-Hwan;Ha, Duk-Min;Shin, Yong-Hwan
    • Journal of Animal Environmental Science
    • /
    • v.19 no.2
    • /
    • pp.169-176
    • /
    • 2013
  • This survey was conducted to investigate the present conditions of operational management in the 45 animal manure public resource center (APRC) in Korea. The regional distribution, processing capacity per year, capacity of liquid fertilizer storage tank, solid-liquid separation, utilization of facilities, odor reduction facility, on-site odor strength, complained in the community, liquid fertilizer sprayed area, use the Agrix, land application recipe, composting degree, quality management and general grading were surveyed and evaluated. General grading was divided with 5 stages (very good, good, fair, lack and bad). The number of evaluated "very good" animal manure public resource center was 7, and "good" was 5 and more than "fair" was 27. However, the number of evaluated negatively including "lack" and "bad" was occupied as 40% of the 45 animal manure public resource center.

Development of a Closed Roof Model for Liquid Manure Storage Tanks to Prevent Corrosion and Atmospheric Diffusion of Oder Gases (부식과 악취가스 대기확산 방지를 위한 액비저장조 밀폐형 지붕모델 개발)

  • Yun, N.K.;Lee, S.H.;Kim, K.W.;Yum, S.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2008
  • The roof structural model of liquid manure storage tank was designed to improve a structural safety and an ability of resistance to corrosion by the bad environmental condition with high humidity and high gas concentration. Due to corrosion of a general steel, the 5 years used materials were reduced to one-third of a new material in the result of a bending strength test. Some structural materials were tested to evaluate a strength and an anti-corrosion, and stainless steel pipe (STS439), steel angle with zinc hot dipping, rectangular steel pipe covered with FRP (Fiberglass Reinforced Plastics) resin were selected finally. A stainless steel is more expansive about $3{\sim}5$ times than general structural steel. But its durability under heavy corrosive environment is expected twice as long as general steel. The roof models were designed as closed cone type for each of the three structural materials. In the result of a FEM (Finite Element Method) structural analysis for the developed models, the safe snow depth was higher 2.3 times than a general roof structure, when elements of equal section modulus were used.

  • PDF

Design and Operation of a Small-Scale Hydrogen Liquefier (소형 수소액화기 설계 및 운전에 관한 연구)

  • Baik, Jong Hoon;Karng, Sarng Woo;Kang, Hyungmook;Garceau, Nathaniel;Kim, Seo Young;Oh, In-Hwan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.2
    • /
    • pp.105-113
    • /
    • 2015
  • In order to accelerate hydrogen society in current big renewable energy trend, it is very important that hydrogen can be transported and stored as a fuel in efficient and economical fashion. In this perspective, liquid hydrogen can be considered as one of the most prospective storage methods that can bring early arrival of the hydrogen society by its high gravimetric energy density. In this study, a small-scale hydrogen liquefier has been designed and developed to demonstrate direct hydrogen liquefaction technology. Gifford-McMahon (GM) cryocooler was employed to cool warm hydrogen gas to normal boiling point of hydrogen at 20K. Various cryogenic insulation technologies such as double walled vacuum vessels and multi-layer insulation were used to minimize heat leak from ambient. A liquid nitrogen assisted precooler, two ortho-para hydrogen catalytic converters, and highly efficient heat pipe were adapted to achieve the target liquefaction rate of 1L/hr. The liquefier has successfully demonstrated more than 1L/hr of hydrogen liquefaction. The system also has demonstrated its versatile usage as a very efficient 150L liquid hydrogen storage tank.

Performance Enhancement of the Heat Pump Using the Refrigerant Subcooling System (냉매 과냉각 시스템을 이용한 열펌프의 성능향상에 관한 연구)

  • 손창효;윤찬일;박승준;이동건;오후규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.106-111
    • /
    • 2001
  • The performance characteristics of heat pump system using the new refrigerant subcooling system were investigated. The new heat pump system has the ice storage tank to accumulate the latent heat of the refrigerant during the night-time. The heat is released to subcool the saturated refrigerant liquid at the outlet of a condenser in the daytime. The experimental apparatus is a well-instrumented heat pump which consisted of a refrigerant loop and a coolant loop. The test sections(condenser and evaporator) were made of tube-in-tube heat exchanger with the horizontal copper tube of 12.7[mm] outer diameter and 9.5[mm] inner diameter. The evaporating temperatures ranged from $-5[^{\circ}C]$ to $0[^{\circ}C]$ and the subcooling degrees of the refrigerant varied from $15[^{\circ}C]$ to $25[^{\circ}C]$. The test of the ice storage was carried out at evaporating temperature of $-10[^{\circ}C]$ and the ice storage mode is an ice-on-coil type. The main results were summarized as follows ; The refrigerant mass flow rate and compressor shaft power of the heat pump system were independent of the subcooling degrees. The cooling capacity o the heat pump system increases as the evaporating temperature and subcooling degree increases. The cooling capacity of the heat pump system is about 25 to 30% higher than that of normal heat pump system. The COP of the heat pump system which subcooled the refrigerant liquid at the outlet of the condenser is about 28% higher than that of the normal heat pump system.

  • PDF

Improvement of Insulation System for LNG Storage Tank Base Slab (LNG 저장탱크 바닥판 단열 시스템 개선)

  • Lee, Yong-Jin;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.141-147
    • /
    • 2010
  • Liquefied natural gas(LNG) is natural gas that has been converted temporarily to liquid form for ease of storage and transport it. Natural gas is the worlds cleanest burning fossil fuel and it has emerged as the environmentally preferred fuel of choice. In Korea, the demand of this has been increased since the first import from the Indonesia in 1986. LNG takes up about 1/600th the volume of natural gas in the gaseous state by cooling it to approximately $-162^{\circ}C(-260^{\circ}F)$. The reduction in volume therefore makes it much more cost efficient to transport and store it. Modern LNG storage tanks are typically the full containment type, which is a double-wall construction with reinforced concrete outer wall and a high-nickel steel inner tank, with extremely efficient insulation between the walls. The insulation will be installed to LNG outer tank for the isolation of cryogenic temperature. The insulation will be installed in the base slab, wall and at the roof. According to the insulation's arrangement, the different aspects of temperature transmission is shown around the outer tank. As the result of the thermal & stress analysis, by the installing cellular glass underneath the perlite concrete, the temperature difference is greatly reduced between the ambient temperature and inside of concrete wall, also reducing section force according to temperature load.

A Study on the Weld Part Fracture Toughness of Austenite Type Stainless Steel for Cryogenic Liquid Nitrogen Storage Tank (초저온 액화질소 저장탱크 오스트나이트계 스테인리스강의 용접부의 파괴인성 연구)

  • Kim, Young-Deuk;Choi, Dong-Jun;Park, Hyung-Wook;Cho, Jong-Rae;Bae, Won-Byoung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.802-808
    • /
    • 2011
  • One of the important mechanical properties of cryogenic temperature structure material is fracture toughness. Research on normalization of fracture toughness test method is becoming very important issue with development of cryogenic structural elements. Specially, mechanical properties estimation by each micro-structure of welding department is important because it can cause unstable fracture when use under cryogenic environment in case of welding department. In this study, fracture toughness estimation test was carried out to unloading compliance method and sensitization heat-tread minimized test specimen at liquid nitrogen (77K), liquid helium (4K), 293K temperature to STS-316L base metal and weld metal.

An Extremely Low Temperature Properties of Wrought Aluminum Alloys (가공용 알루미늄 합금의 극저온 특성)

  • Jung, Chan-Hoi;Kim, Soon-Kook;Lee, Jun-Hee;Lee, Hae-Woo;Jang, Chang-Woo
    • Korean Journal of Materials Research
    • /
    • v.17 no.4
    • /
    • pp.192-197
    • /
    • 2007
  • The effects of immersion time in the liquid nitrogen on the behavior of aluminum alloys used for the hydrogen storage tank of auto-mobile at cryogenic temperature were investigated. With increasing immersion time in the liquid nitrogen, the elongation of AI 5083 alloy at cryogenic temperature decreased because of non-uniform fracture of precipitates on the grain boundary, and the serration also occurred because of discontinuous slip due to rapid decreasing of the specific heat. The mechanical properties of AI 6061 alloy at cryogenic temperature were characterized by uniformed yield strength, tensile strength and elongation regardless of the immersion time in the liquid nitrogen. These mechanical properties of aluminum alloys at cryogenic temperature were interpreted by the strength of grain boundary and the slip deformation behavior.