• Title/Summary/Keyword: Liquid in a tank

Search Result 449, Processing Time 0.027 seconds

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Rabbit's Cervical Tracheal Replacement with Cryopreserved Homograft - Effects on the Viability and Rejection - (토끼 경부기관의 초냉동보관 동종이식편 기관 이식술 - 생육성 및 거부반응에 미치는 영향 -)

  • 원태희;서정욱;성숙환
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1127-1133
    • /
    • 1998
  • Background: There are no ideal substitutes for tracheal replacement. Therefore we investigated the possibility of clinical use of cryopreserved tracheal homograft with special interest in the viability and rejection of the epithelial cell and cartilage. Material and Method: Rabbit's trachea was sected and stored in liquid nitrogen tank for 1 month. Tracheal replacement was done in 45 rabbits with autograft(n=15, Group 1), fresh allograft(n=15, Group 2) and cryopreserved homograft(n=15, Group 3). After 7, 14, and 30 days, 5 rabbits in each group were sacrificed and the regeneration of epithelium and cartilage and the degree of rejection were assessed by counting the monocellular infiltration. Result: Investigation at day 7, showed no difference in epithelial regeneration, however, at days 14 and 30, Group 1 showed better regeneration of epithelium than groups 2 and 3. There was no difference of epithelial regeneration between group 2 and 3. There was little rejection at day 7, but at days 14 and 30, there was significant rejection in group 2 and group 3.(P<0.05). Group 3 showed lesser rejection than group 2 at days 14 and 30, but it was not statistically significant. Cartilage showed no rejection and maintained its viability in groups 2 and 3. Conclusion: Cryopreserved tracheal homograft can maintain its viability, therefore it may represent a possibility of clinical application for tracheal replacement. However, cryopreservation can not eliminate the antigenicity of the trachea completely. Furthere studies for lowering the antigenicity and rejection should be performed for an ideal substitute for tracheal replacement.

  • PDF

Comparative Study on Removal Characteristics of Disinfection By-products by Air Stripping and Flotation Processes (탈기와 부상 공정에 의한 소독부산물의 제거특성에 관한 비교 연구)

  • Cha, Hwa-Jeong;Won, Chan-Hee;Lee, Kang-Hag;Oh, Won-Kyu;Kwak, Dong-Heui
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.513-520
    • /
    • 2016
  • It is well known that volatile compounds including disinfection by-products as well as emissive dissolved gas in water can be removed effectively by air stripping. The micro-bubbles of flotation unit are so tiny as microns while the diameter of fine bubbles applied to air stripping is ranged from hundreds to thousands of micrometer. Therefore, the micro-bubbles in flotation can supply very wide specific surface area to transfer volatile matters through gas-liquid boundary. In addition, long emission time also can be gained to emit the volatile compound owing to the slow rise velocity of micro-bubbles in the flotation tank. There was a significant difference of the THMs species removal efficiency between air stripping and flotation experiments in this study. Moreover, the results of comparative experiments on the removal characteristics of THMs between air stripping and flotation revealed that the mass transfer coefficient, $K_La$ showed obvious differences. To overcome the limit of low removal efficiency of dissolved volatile compounds such as THMs in flotation process, the operation range of bubble volume concentration is required to higher than the operation condition of conventional particle separation.

A Study on Worker Exposure to Chromium and Degreasing Solvent at Eleetroplating Operation in Small Industry in Korea (우리나라 중소기업 도금공정 근로자의 크롬 및 세척제 폭로에 관한 연구)

  • Paik, Nam Won;Zong, Moon Shik;Lee, Hong Keun;Yun, Chung Ski;Ceong, Hoe Kyeong;Lee, Kyeong Hee;Lee, Na Roo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.110-126
    • /
    • 1993
  • Worker exposures to total chromium, hexavalent chromium (VI), sulfuric acid and alkaline dust at electroplating operations and worker exposures to trichloroethylene (TCE) and methyl chloroform (MCM) at degreasing operations in eleven small industrial plants were evaluated. Appropriate local exhaust ventilation systems for both operations were designed and recommended. Results of the study are summarized as follows ; 1. Out of 134 measurements for airborne hexavalent chromium concentrations, seven were exceeding the Korean occupational health standard of $50{\mu}g/m^3$ and 45 were exceeding the NIOSH standard of $1{\mu}g/m^3$. With an exception of one measurement, concentrations of total chromium were below the Korean standard of $500{\mu}g/m^3$. 2. Worker exposures to chromium were closely related to the existing control methods at the electroplating operations. Local exhaust systems, partial coverage of the tank surface, and antifoaming agents on liquid surface were adopted as control methods. 3. With an exception of one sample, airborne concentrations of sulfuric acid and alkaline dusts were below the applicable occupational heatlth standards. 4. Three plants indicated that airborne concentrations of TCE and MCM were exceeding the Korean standards. Other plants showed lower concentrations than the standards. It should be noted that generally, the activities and workloads on the day of surveys were less than normal. 5. Since the most existing ventilation systems did not satisfy the ACGIH criteria, the ventilation systems should be improved. Some examples for designing appropriate ventilation systems are presented.

  • PDF

A Study on Solid-liquid Separation of Swine Wastewater Using Coagulation and Dissolved Air Flotation (응집침전 및 부상분리에 의한 돈사폐수의 고액분리에 관한 연구)

  • Kim, Jong-Oh;Jeong, Seong-Uk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • In this study, the solid-liquid separation characteristics of swine wastewater were investigated for the coagulation and dissolved air flotation (DAF). Coagulation characteristics were studied using jar-tester with the different coagulants and dosage amounts. DAF characteristics were also investigated in terms of the different flotation conditions with the raw swine wastewater, pH adjustment only, and adding coagulants. When the raw swine wastewater was coagulated with the only inorganic coagulants, the proper inorganic coagulants were founded as $FeCl_3$ > PAC > Alum orderly, and the optimal coagulant dosages were founded as $1,000mg/{\ell}$, $1,500mg/{\ell}$, $1,500mg/{\ell}$, respectively. As the raw swine wastewater was treated with the polymer coagulants, the only cationic polymer coagulant showed an effective coagulation and the optimal dosage of cationic coagulant was founded as $200mg/{\ell}$. When the different dosages of cationic polymer was added to each $500mg/{\ell}$ of the inorganic coagulants, the proper inorganic coagulants were founded as $FeCl_3$ > Alum > PAC orderly, and optimal cationic polymer dosages was founded as $25mg/{\ell}$, $25mg/{\ell}$, and $100mg/{\ell}$, respectively. Resulting from the raw swine wastewater experiments using DAF without coagulation, the proper operation conditions of DAF were set to 400% of recycling ratio, 4 atm in air dissolving tank, and under pH 3. But the raw swine wastewater was difficult to successfully operate DAF without pre-coagulation. While the DAF separation after pre-coagulation using inorganic coagulants was not accomplished due to the low intensity of the floc, DAF after pre-coagulation using both the inorganic and cationic polymer coagulants was accomplished very well. Optimal dosage of cationic polymer coagulant in case of $500mg/{\ell}$ Alum dosage was founded as $500mg/{\ell}$.

  • PDF

Neuroprotective Effects of Modified Yuldahanso-tang (MYH) in a Parkinson's Disease Mouse Model (MPTP로 유도된 Parkinson's disease 동물 모델에서 열다한소탕 가감방 (MYH)의 신경 세포 보호 효과)

  • Go, Ga-Yeon;Kim, Yoon-Ha;Ahn, Taek-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.27 no.2
    • /
    • pp.270-287
    • /
    • 2015
  • Objectives To evaluate the neuroprotective effects of modified Yuldahanso-tang (MYH) in a Parkinson's disease mouse model. Methods 1) Four groups (each of 8 rats per group) were used in this study. 2) The neuroprotective effect of MYH was examined in a Parkinson's disease mouse model. C57BL/6 mice treated with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP, 30 mg/kg/day), intraperitoneal (i.p.) for 5 days. 3) The brains of 2 mice per group were removed and frozen at $-20^{\circ}C$, and the striatum-substantia nigra part was seperated. The protein volume was measured by Bradford method following Bio-Rad protein analyzing kit. Using mouse/Rat Dopamine ELISA Assay Kit. 4) The brains of 2 mice per group were separated and removed. TH-immunohistochemical was examined in the MPTP-induced Parkinson's disease mice to evaluate the neuroprotective effects of MYH on ST and SNpc. 5) Two mice out of each group were anesthetized and skulls were opened from occipital to frontal direction to take out the brains. The brains added TTC solution for 20 minutes for staining. 6) The water tank used for morris water maze test was filled with $28^{\circ}C$ water, and a round platform of 10cm in diameter was installed for mice to step on. The study was carried out once a day within 30 seconds, keep exercising to step on the platform in the pool. 7) The brains of two mice out of each group were fixed in 10% formaldehyde solution and paraphillin substance was infiltrated. They were fragmented by microtome, and observed under an optical microscope after Hematoxylin & Eosin staining. 8) A round acrylic cylinder with its upper side open was filled with clean water and depressive mouse models were forced to swim for 15 minutes. After 24 hours the animals were put in the same equipment for 5 minutes and were forced to swim. 9) The convenient, simple, and accurate high-performance liquid chromatography (HPLC) method was established for simultaneous determination of Neurotransmitters in MPTP-MYH group. Results 1) MYH possess Dopamine cell protective effect on MPTP-induced injury in striatum and substantia nigra pars compacta. 2) MYH inhibits the loss of tyrosine hydroxylase-immunoreacitive (TH-IR) cells in the striatum and substantia nigra pars compacta on MPTP-induced injury in C57BL/6 mice. 3) MYH possesses improvement effect on MPTP-induced memory deterioration in C57BL/6 mice through the reduction of prolongated Sort of lost time by MPTP injection using the Morris water maze test. 4) MYH possesses hippocampal neuron protective effect on MPTP-induced injury in C57BL/6 mice. 5) MYH possesses improvement effect on MPTP-induced motor behaviour deficits and depression in C57BL/6 mice through the reduction of prolongated losing motion by MPTP injection using the Forced swimming test. 6) MYH increases serotonin product amount on MPTP-induced injury in C57BL/6 mice. Conclusions This experiment suggests that the neuroprotective effect of MYH is mediated by the increase in Dopamin, TH-ir cell, Hippocampus and Serotonin. Furthermore, MYH essential oil may serve as a potential preventive or therapeutic agent regarding Parkinson's disease.

Investigation of ground condition charges due to cryogenic conditions in an underground LNG storage plant (지하 LNG 저장 시험장에서 극저온 환경에 의한 지반상태 변화의 규명)

  • Yi Myeong-Jong;Kim Jung-Ho;Park Sam-Gyu;Son Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.67-72
    • /
    • 2005
  • To investigate the feasibility of a new concept of storing Liquefied Natural Gas (LNG) in a lined hard rock cavern, and to develop essential technologies for constructing underground LNG storage facilities, a small pilot plant storing liquid nitrogen (LN2) has been constructed at the Korea Institute of Geoscience and Mineral Resources (KIGAM). The LN2 stored in the cavern will subject the host rock around the cavern to very low temperatures, which is expected to cause the development of an ice ring and the change of ground condition around the storage cavern. To investigate and monitor changes in ground conditions at this pilot plant site, geophysical, hydrogeological, and rock mechanical investigations were carried out. In particular, geophysical methods including borehole radar and three-dimensional (3D) resistivity surveys were used to identify and monitor the development of an ice ring, and other possible changes in ground conditions resulting from the very low temperature of LN2 in the storage tank. We acquired 3D resistivity data before and after storing the LN2, and the results were compared. From the 3D images obtained during the three phases of the resistivity monitoring survey, we delineated zones of distinct resistivity changes that are closely related to the storage of LN2. In these results, we observed a decrease in resistivity at the eastern part of the storage cavern. Comparing the hydrogeological data and Joint patterns around the storage cavern, we interpret this change in resistivity to result from changes in the groundwater flow pattern. Freezing of the host rock by the very low temperature of LN2 causes a drastic change in the hydrogeological conditions and groundwater flow patterns in this pilot plant.

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

Viability of Endothelial Cells in Preserved Human Saphenous Vein Allografts (보존된 사람 동종 복재정맥 이식편혈관 내피세포의 생활성에 관한 연구)

  • 지현근;김용진
    • Journal of Chest Surgery
    • /
    • v.36 no.4
    • /
    • pp.229-241
    • /
    • 2003
  • Background:Autogenous vein is the preferred vascular graft for patients who require coronary artery bypass surgery or peripheral arterial bypass surgery. When an autogenous vein is not available, an allograft saphenous vein can be used as an alternative conduit. Although arterial homograft has been under investigation since the beginning of this century, the viability of endothelial cells and the optimum mode of storage for the venous and arterial allografts is controversial. In addition, with the recently gained knowledge of vascular endothelial functions, such as the production of nitric oxide or thrombomodulin, the viability and antigenicity of endothelial cells are being studied again. The purpose of this study was to evaluate the viability of endothelial cells in the preserved human saphenous veins. Material and Method: The veins were stored in a $4^{\circ}C$ RPMI (Roswell Park Memorial Institute) 1640 solution including 10% fetal calf serum, for one, three, five, seven or fourteen days. After the completion of the storage period, the veins were divided into two groups: Group I: studied immediately at $4^{\circ}C$ (cold) storage (I-1, I-3, I-5, I-7, I-14), and Group II: studied after storage at $-196^{\circ}C$ liquid nitrogen tank (cryopreservation) in an RPMI 1640 solution containing 10% DMSO for two weeks (II-1, II-3, II-5, II-7, II-14). Light microscopy and scanning electron microscopy (SEM), frypan blue exclusion testing, and thrombomodulin immunohistochemistry were performed. Result: In a morphometric study using SEM, there was statistically significant increase in Gundry Score in Groups I-7, I-14, II-5, II-7, and II-14 and showed cellular destruction (p<0.05). In the thrombomodulin immunohistochemistry study, there was reactivity in Groups I-1, I-3, and I-5, but the cryopreserved group revealed decreased reactivity (p<0.05). The trypan blue exclusion testing also showed superior viability in cold storage Group I. Conclusion: Venous allografts preserved in a $4^{\circ}C$ RPMI 1640 solution showed well preserved endothelial cellular integrity and thrombomodulin expression at up to seven days of preservation. Although cryopreservation of venous allografts stored in 10% DMSO -RPMI 1640 solution maintained the endothelial cellular structure on SEM, immunohistochemistry from the thrombomodulin and trypan blue exclusion testing showed decreased viability, It remains to be seen whether the decreased thrombomodulin reactivity could be restored, and what the nature to the relationship is between thrombomodulin and long-term patency of allografts.