• 제목/요약/키워드: Liquid holdup

검색결과 31건 처리시간 0.021초

Modeling and simulation of air-water upward annular flow characteristics in a vertical tube using CFD

  • Anadi Mondal;Subash L Sharma
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2881-2892
    • /
    • 2024
  • Annular flow refers to a special type of two-phase flow pattern in which liquid flows as a thin film at the periphery of a pipe, tube, or conduit, and gas with relatively high velocity flows at the center of the flow section. This gas also includes dispersed liquid droplets. The liquid film flow rate continuously changes inside the tube due to two processes-entrainment and deposition. To determine the liquid holdup, pressure drop, the onset of dryout, and heat transfer characteristics in annular flow, it is important to have proper knowledge of flow characteristics. Especially a better understanding of entrainment fraction is important for the heat transfer and safe operation of two-phase flow systems operating in an annular two-phase flow regime. Therefore, the objective of this work is to develop a computational model for the simulation of the annular two-phase flow regime and assess the various existing models for the entrainment rate. In this work, Computational Fluid Dynamics (CFD) in ANSYS FLUENT has been applied to determine annular flow characteristics such as liquid film thickness, film velocity, entrainment rate, deposition rate, and entrainment fraction for various gas-liquid flow conditions in a vertical upward tube. The gas core with droplets was simulated using the Discrete Phase Model (DPM) which is based on the Eulerian-Lagrangian approach. The Eulerian Wall Film (EWF) model was utilized to simulate liquid film on the tube wall. Three different models of Entrainment rate were implemented and assessed through user-defined functions (UDF) in ANSYS. Finally, entrainment for fully developed flow was determined and compared with the experimental data available in the literature. From the simulations, it was obtained that the Bertodano correlation performed best in predicting entrainment fraction and the results were within the ±30 % limit when compared to experimental data.

소형냉각재 상실사고시 루프밀봉 형성 및 제거에 대한 예측 (Prediction of Loop Seal Formation and Clearing During Small Break Loss of Coolant Accident)

  • Lee, Sukho;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.243-251
    • /
    • 1992
  • 소형 냉각재 상실사고시 루프밀봉 형성 및 제거에 대하여 LSTF에서 수행된 실험 SB-CL-18의 결과를 RELAP5/MOD2와 /MOD3를 이용하여 예측하였다. 본 연구는 증기발생기 상향 및 하향 유동에서의 비대칭 냉각재수용에 따른 마노메트릭 유동에 의해 노심노출의 조기발생을 야기시키는 열수력학적 현상을 예측하기 위하여 수행되었다. RELAP5/MOD2를 이용한 해석결과는 루프밀봉 형성 및 제거를 포함하여 감압사고시의 주요 현상을 전반적으로 잘 예측하고 있으나 기초 계산외 결과를 볼 때 현상 및 시간적 순서에 관련하여 몇 가지의 차이가 있었다. RELAP5/MOD3는 RELAP5/MOD2보다 전반적인 현상, 특히 증기발생기 액체수용을 보다 잘 예측하고 있으며, 또 한 RELAP5/MOD3를 이용하여 증기발생기 U자관과 펌프 흡입관의 nodalization수를 늘린 경우는 루프 밀봉제거현상과 시간적 순서를 잘 예측할 수 있었다.

  • PDF

열화상카메라를 이용한 직물의 물 흡수 및 건조 특성에 대한 실험 연구 (Experimental Study on Water Absorption and Drying Characteristics of Various Fabrics using IR Camera)

  • 김정배
    • 한국분무공학회지
    • /
    • 제28권1호
    • /
    • pp.10-15
    • /
    • 2023
  • Recently, various types of towels and dishcloth dryer products are being widely distributed in Korea. Evaluation methods for water absorption properties of various fabrics have been developed, and there are many studies using them. This study newly intended that whether it is possible to obtain data that can quantitatively analyze the water absorption characteristics of various fabrics, to show the correlation between the water absorption height and the amount of water (water holdup) absorbed, and to experimentally suggest the applicability to evaluate the drying capacity of towel dryer using IR camera. Through these experiments, it was confirmed that quantitative data on the water absorption height of various fabrics can be measured using an IR camera and can be clearly applied to the performance evaluation of actual products.

대기오염제어를 위한 생물살수여과법에서 물질전달계수 실험평가방법에 관한 연구 (Experimental Evaluation Method of Mass Transfer Coefficient on Biotrickling Filtration for Air Pollution Control)

  • 원양수;조완근
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.482-488
    • /
    • 2015
  • 생물학적 방법에 의한 대기오염물질 처리는 기존의 처리방법을 대체할 수 있는 방법으로 각광을 받고 있다. 생물학적 처리방법은 유기화합물 또는 악취가 포함된 저농도 고유량의 공기를 처리하는데 효과적이다. 생물살수여과법을 이용한 대기오염물질 제거에서 물질전달 연구는 공정 최적화를 위해 매우 중요한 부분이다. 본 연구에서는 3상의 물질전달이 이루어지는 생물살수여과법에서 기체/액체(살수액), 기체/고체(미생물), 액체/고체 물질전달 실험방법 개발과 물질전달 현상을 고찰하였다. 또한 본 연구에서는 각 상간에서 물질전달에 영향을 미치는 인자로 동적적체량, 기/액 유량비, 반응기내 미생물량, 살수액 순환량 등에 대해 고찰하였다.

고부하 유기성 폐수처리를 위한 분리막 결합형 순산소 고효율 포기장치의 총괄 산소전달효율 평가 (Comparison of Overall Oxygen Transfer Coefficient in the Membrane Coupled High Performance Reactor for a High Organic Loading Wastewater Treatment)

  • 강범희;임경호;이상민
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.81-88
    • /
    • 2010
  • This study was conducted to find the capability of comparison of overall oxygen transfer coefficient in the membrane coupled high performance reactor (MPHCR) in treating high organic loading wastewater. Effluent quality had been analyzed while the influent organic loading rate was changed from 2 to $7kg\;COD/m^3{\cdot}day$. The oxygen transfer coefficients had been investigated using two-phase nozzle for operating variables which were internal circulation flowrate (5~8 L/min), air flow rate (0.0125~0.2 L/min), liquid temperature ($10{\sim}20^{\circ}C$), and pure-oxygen flow rate (0.0125~0.2 L/min). The overall oxygen transfer coefficient was increased with flowrate of internal circulation and air and high temperature. Especially, internal circulation flow rate showed distinct effect on overall oxygen transfer coefficient due to an increase of gas holdup and air-liquid contract area by two-phase nozzle. In the high range of organic loading rate from 4 to $7kg\;COD/m^3{\cdot}day$, the removable efficiency of COD was 91%. Conventional activated sludge process usually treat organic loading from 0.32 to $0.64kg\;COD/m^3{\cdot}day$ however, the MPHCR can treat 10 to 20 times higher if it would be compared to the conventional activated sludge process. Foaming problem often happened and caused biomass wash out of the reactor, therefore, the foaming should be controlled for the enhanced operation.

단일노즐을 사용한 내부순환 공기리프트 반응기에서 수력학과 액체의 흐름특성 (Hydrodynamics and Liquid Flow Characteristics in an Internal Circulation Airlift Reactor using a Single Nozzle)

  • 김종철;장서일;손민일;김태옥
    • 공업화학
    • /
    • 제8권5호
    • /
    • pp.816-821
    • /
    • 1997
  • 기체분산기로 단일노즐을 사용한 내부순환 공기리프트 반응기에서 수력학과 액체의 흐름특성을 해석하였다. 실험은 공기-물계에서 기체속도와 반응기의 높이를 변화시키면서 국부지역의 기체체류량과 추적자의 충격-응답곡선을 측정하였다. 실험결과, 약 8 cm/s이상의 기체속도에서 상승관은 기포가 강한 합체를 일으키는 난류흐름을 나타내었고 하강관에서는 균일한 크기의 큰 기포들이 분산된 지역까지의 축방향 높이가 기체속도의 증가에 따라 감소하였다. 그리고 국부지역과 반응기 전체의 평균 기체체류량은 기체속도가 증가할수록 증가하였고 반응기 상부지역의 높이가 증가할수록 감소하였다. 또한 혼합시간은 기체속도보다 반응기 상부지역의 높이에 크게 영향을 받으며 이들이 증가할수록 감소하였다. 상승관과 하강관에서 액체의 흐름은 플러그흐름에 근접하였고 환전혼합흐름으로 볼 수 있는 반응기 상부지역의 크기에 따라 반응기 전체의 액체흐름특성이 크게 변화하였다. 이때 액체의 순환속도는 기체속도가 증가할수록 증가하였고 다른 기체분산기에서 보다 상당히 큰 값을 나타내었다.

  • PDF

기포탑에서 작은기포와 큰기포의 크기 구별 (Size Verification of Small and Large Bubbles in a Bubble Column)

  • 서명재;진해룡;임대호;임호;강용;전기원
    • Korean Chemical Engineering Research
    • /
    • 제50권2호
    • /
    • pp.304-309
    • /
    • 2012
  • 동력학적 기체유출방법(dynamic gas disengagement method)과 이중전기저항 탐침방법(dual electrical resistivity probe method)을 동시에 사용하여 기포탑에서 큰 기포와 작은 기포의 크기를 구별하였다. 기포탑의 일정한 운전조건에서 기포탑 내부에 체류하는 큰 기포와 작은 기포의 체류량은, 기포탑에 유입되는 기체의 유입을 차단한 후 시간의 흐름에 따른 기포탑 내부의 압력강하 변화를 측정하여 동력학적 기체유출방법에 의해 측정하였다. 기포의 크기와 빈도수는 동력학적 기체유출방법에 의해 큰 기포와 작은 기포의 체류량을 측정하는 동일한 운전조건에서 측정하였으며 이들 자료들로부터 기포의 크기에 따른 기포의 체류량을 결정하였다. 기포탑에서 큰 기포와 작은 기포의 크기결정은 동력학적 기체유출방법에 의해 얻은 큰 기포와 작은 기포의 체류량과 이중전기저항 탐침법에 의해 구한 크기의 범위를 아는 기포들의 체류량을 비교하여 결정하였다. 여과된 압축 공기와 물을 기체상과 연속액상을 사용하였으며, 기포탑의 직경은 0.102 m이고 높이는 1.5 m이었다. 기포탑에서 큰 기포와 작은 기포의 경계 크기는 4.0~5.0 mm 이었는데, 기체의 유속이 낮은 범위에서는 큰 기포와 작은 기포의 경계 크기가 5.0 mm 정도이었으나 기체의 유속이 상대적으로 큰 범위에서는 큰 기포와 작은 기포의 경계 크기가 4.0 mm 정도가 되었다.

단일노즐을 사용한 내부순환 공기리프트 반응기에서 기체 및 액체의 유동특성 - 유동지역의 크기영향 - (Gas and Liquid Flow Characteristics in an Internal Circulation Airlift Reactor using a Single Nozzle -Effects of Flow Zone Sizes-)

  • 장서일;김종철;장영준;손민일;김태옥
    • 공업화학
    • /
    • 제9권6호
    • /
    • pp.901-906
    • /
    • 1998
  • 기체분산기로 단일노즐을 사용한 내부순환 공기리프트 반응기에서 기체 및 액체의 유동특성을 해석하였다. 실험은 공기-물계에서 하강관의 직경과 상승관의 높이가 다른 세 가지 반응기를 사용하여 기체속도와 반응기의 높이를 변화시키면서 각 유동지역의 기체체류량과 추적자의 충격-응답곡선을 측정하였다. 실험결과, 기포의 유동양상은 상승관에서 강한 기포합체를 일으키는 슬러그흐름을, 그리고 하강관에서는 직경의 크기에 따라 전이흐름 또는 균일상 기포흐름을 나타내었다. 그리고 동일한 반응기 상부지역의 높이비에서 각 유동지역과 반응기 전체의 평균 기체체류량은 하강관의 직경이 작을수록 상당히 증가하였다. 또한 혼합시간은 기체속도보다 반응기 상부지역의 높이에 크게 영향을 받으며 동일한 반응기 상부지역의 높이비에서는 하강관의 직경과 상승관의 길이가 클수록 상당히 큰 값을 나타내었다. 액체의 유동특성은 하강관에서 기포의 유동양상과 반응기 상부지역의 크기에 따라 크게 변화하였으며 상승관에서 액체의 순환속도는 기체속도와 반응기 상부지역의 크기가 증가할수록 증가하였고 동일한 반응기 상부지역의 높이비에서는 하강관의 직경과 상승관의 길이가 증가할수록 증가하였다.

  • PDF

삼상 역 유동층의 수력학, 열전달 및 물질전달 특성 (Characteristics of Hydrodynamics, Heat and Mass Transfer in Three-Phase Inverse Fluidized Beds)

  • 강용;이경일;신익상;손성모;김상돈;정헌
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.451-464
    • /
    • 2008
  • 삼상 역 유동층은 유동하거나 부유하는 입자의 크기가 매우 작은 경우나 유동입자의 밀도가 액체보다 작은 담체나 접촉매체 또는 촉매전달물질인 경우에 생물반응기, 발효공정, 폐수처리공정, 흡착, 흡수공정 등에 매우 효과적으로 사용될 수 있어서 그 적용성은 날로 증대되고 있다. 그러나, 삼상 역 유동층에 대해서는 많은 연구가 진행되지 않아 왔으며 수력학적 특성에 대한 연구조차도 미흡한 실정이다. 삼상 역 유동층을 이용한 많은 종류의 반응기와 공정들의 운전과 설계 그리고 scale-up을 위해서는 삼상 역 유동층에서 수력학적 특성과 열전달과 물질전달과 같은 이동현상에 대한 정보는 필수적이라는 것은 자명한 사실이다. 따라서, 본 총설에서는 삼상 역 유동층에 대한 정보들을 공학적 측면에서 요약하고 재정리하여서 이 분야의 현장에서 필요한 지식들을 제안하고자 하였다. 본 논문은 수력학적 특성, 열전달 특성 그리고 물질전달 특성의 세 부분으로 이루어져있다. 즉, 수력학적 특성 부분에서는 운전변수가 상 체류량, 기포의 특성 그리고 유동입자의 분산에 미치는 영향을 검토하였으며, 열전달 특성 부분에서는 삼상 역 유동층에서의 운전변수가 열전달 계수에 미치는 영향을 고찰하였고, 열전달 모델에 대한 정리를 하였으며, 물질전달 특성 부분에서는 운전변수가 연속액상의 축방향 분산계수 및 액상 부피물질전달계수에 미치는 영향에 대해 고찰하였다. 또한, 각 절에서 유동입자의 최소유동화속도, 상 체류량, 기포특성, 유동입자의 요동빈도수 및 유동입자의 분산 등과 같은 수력학적 특성과 열전달 계수 그리고 연속액상의 축방향 확산계수와 물질전달계수 등을 예측할 수 있는 상관식들을 제안하였다. 본 총설의 마지막 절에서는 삼상 역 유동층의 공업적 응용을 위해 앞으로 더 연구해야하는 내용에 대해 제안을 하였다.

증류탑 성능평가에 적합한 소형 증류탑 개발 (Development of Small Distillation Column for Performance Evaluation of Distillation Column)

  • 김병철;조태제;김영한
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.668-671
    • /
    • 2010
  • 증류시스템 검증용 소형 다단 증류 장치에 활용할 수 있는 소형 충전물을 사용하여 실험실 규모의 증류실험을 실시하였다. 직경 6.7 mm의 실린더형 스테인레스 스틸 충전물을 이용하여 충분한 겉보기 표면적을 얻었고, 액의 체류량과 체류 속도도 양호한 결과를 얻었다. HYSYS를 이용한 이론단수의 계산치와 증류실험치를 비교하여 27 cm 충전층에 대해서는 7 cm이고, 45 cm 충전층에 대해서는 8 cm의 충전층이 이론단 1 단에 해당함을 알았다. 상업용 일정구조 배열의 충전탑에서 8 cm의 충전층이 이론단 1 단에 해당함과 비교하면 유사한 증류효율을 얻을 수 있음을 보여 주었다. 이러한 결과는 증류관의 보온이 완벽할 때 가능하였으며, 실험실에서의 증류 실험에서는 보온이 중요함을 입증하였다. 본 실험 결과로부터 실험실에서도 실제 현장에서 사용하는 증류탑과 유사한 증류 시스템의 시험이 가능함을 보여 준다.