• Title/Summary/Keyword: Liquid Liquid Extraction

Search Result 1,075, Processing Time 0.026 seconds

Determination of 3-phenoxybenzoic Acid in Urine and Exposure Assessment of Pyrethroid Insecticides to Human Being (요중 3-phenoxybenzoic acid 미량 분석 및 pyrethroid계 살포자 노출 평가)

  • Seo, Jong-Chul;Song, Jae-Seok;Choi, Hong-Soon
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • Pyrethroid insecticide have widely been used for agricultural sector and residential environments. To assess the exposure of insecticide which is absorbed through skin the analysis of urinary metabolite is essential. At present, the urinary 3-PBA was analyzed using liquid-phase extraction. But LPE have many limitations, such as long pre-treatment time and low recovery. So, this study was conducted to determine the optimum conditions for analysing 3-PBA in urine using solid phase extraction. Furthermore, this study intend to investigate the relation of concentrations of pyrethroid, deltamethrin in air and 3-PBA in urine. The optimum condition for hydrolysis was found to be done with hydrochloric acid for one hour. The recovery rates of 3-PBA were $84.6%{\pm}1.2%$, $54.8{\pm}0.9%$, $99.8{\pm}1.2%$ with XAD-2, XAD-7, XAD-16 using as the aborbents and acetone as eluents respectively. But acetonitrle and methanol gave low recovery rate and methyl cellosolve could not elute the compound. The amount of acetone for elution were 6mL, 9mL, 3mL for XAD-2, XAD-7, XAD-16 as absorbents respectively. The non-absorbed rates was $0.8{\pm}0.5%$, and $0.7{\pm}0.3%$ under XAD-16, mesh size 140-200, amount of resin 1.4g and the flow rate of eluent was 0.1mL/min. In the concentration process, we obtained 11 times higher concentration of material. The amounts of urinary 3-PBA were. The LODs of 3-PBA and deltamethrin were 0.004 mg/L, 0.038 mg/L, respectively. The further research of minute monitoring which include spray pattern, environmental condition is needed And more research about the relation between total pyrethroid exposure and urinary various metabolite are also necessary.

Development Status and Research Direction in the Mineral Carbonation Technology Using Steel Slag (제철 슬래그를 이용한 광물 탄산화 기술의 개발 현황과 연구 방향)

  • Son, Minah;Kim, Gookhee;Han, Kunwoo;Lee, Min Woo;Lim, Jun Taek
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.141-155
    • /
    • 2017
  • In the present paper, we investigated the development status of precipitated calcium carbonate (PCC) production using steel slag, which is one of mineral carbonation (MC) technologies, from the standpoint of $CO_2$ utilization. Principle, feature, and global and domestic development status of the mineral carbonation technology were discussed together with the overview of the production method and market of PCC. Mineral carbonation is known as stable and environmentally-friendly technology enabling economical treatment of industrials wastes. Typically, PCC is produced by the reaction of $CO_2$ with supernatant solution after Ca extraction from steel slag followed by the separation of solid and liquid. The development status of MC using steel slag is at the pilot stage (Slag2PCC at Aalto University), and there remains the process economics improvement for commercialization. Key technologies for the further development are efficient extraction of Ca ions from steel slag including impurities removal, valorization of PCC via shape and size control, usage development and value-addition of residual slag, and optimization of reaction conditions for continuous process setup, etc.

Extraction Equilibria of Succinic Acid by Using Aqueous Two Phases System Containing Imidazolium Ionic Liquids and Salts (이미다졸계 이온성액체와 염을 포함한 수상이성분계를 이용한 숙신산의 추출 평형)

  • Lee, Yong Hwa;Kang, Jeong Won;Hong, Yeon Ki;Kim, Ki-Sub
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.349-353
    • /
    • 2014
  • Succinic acid is an important precursor in industries producing biopolymers, pharmaceutical and food additives and green solvents. However, due to the high price of petroleum and the global $CO_2$ emission, the biological production of succinic acid from renewable biomass is a novel process due to the fixation of $CO_2$ into succinate during fermentation. In this study, aqueous two phase systems based on imidazolium ionic liquids/$K_2HPO_4$ were used as an effective separation and concentration process for succinic acid. Experimental results show that aqueous two phase systems can be formed by adding appropriate amount of imidazolium ionic liquids to aqueous $K_2HPO_4$ solutions in the presence of succinic acid. It can be found that the ability of imidazolium ionic liquids for phase separation followed the order [HMIm][Br]${\fallingdotseq}$[OMIm][Br]>[BMIm][Br]>[EMIm][Br]. The maximum value of extraction efficiency for succinic acid was about 90% and the amount of coextracted water into top phase is proportional to the chain length of cation in imidazolium ionic liquids. It was concluded that the aqueous two phase systems composed of imidazolium ionic liquids/$K_2HPO_4$ was effective for the selective extraction and concentration of succinic acid.

Antioxidant capacity and nutritive components from biji sub-micron suspension by ultra-high pressure homogenization process (초고압균질 가공에 의해 제조된 초미세 비지 현탁액의 영양성분 및 항산화성)

  • Lee, Seon-Ho
    • Food Science and Preservation
    • /
    • v.22 no.5
    • /
    • pp.714-720
    • /
    • 2015
  • Biji is a tofu by-product made by squeezing the liquid out of the dregs left over from making tofu. The objectives of this research were to break the biji into sub-micron-scale particles and to prepare a biji sub-micron suspension having increased quality characteristics such as antioxidant capacity, polyphenol, dietary fiber, and soluble protein contents, in comparison with untreated biji. Disruption of biji by an ultra-high-pressure homogenization (UHPH) process was used to prepare the sub-micron suspension of biji. UHPH can be used to prepare emulsions or suspensions with extremely small particle sizes. The effect of the UHPH process on biji was studied at 1,000, 1,500, and 2,000 bar. The extraction yield increased up to 1.64 times by breaking the biji to form a sub-micron suspension. The soluble dietary fiber, protein, and free amino acid contents were increased by the UHPH process (p<0.05), in comparison with those of untreated biji. Furthermore, the total sugar, free sugar, and total polyphenol contents of biji were augmented by the UHPH process. Antioxidant activity (ABTS) after exposure to UHPH (1,000-2,000 bar) was well retained (p<0.05). The extraction efficiencies and nutritive components were enhanced by increasing the pressure in the UHPH process.

A Study on the Antifungal Properties of Ranunculaceae Herbal Medicines (미나리아재비과 한약재의 항진균성 검증 및 비교 연구)

  • Jae-yeoup Lim;Sang Ki Choi
    • Journal of Life Science
    • /
    • v.34 no.6
    • /
    • pp.393-398
    • /
    • 2024
  • The purpose of this study was to verify the antifungal properties of various herbal medicines belonging to the Ranunculaceae family and to find an extraction method effective in inhibiting fungal growth. When antifungal activity was measured in a liquid medium with extracts obtained by either hot water extraction or organic solvent extraction of the herbal medicines Clematis apiifolia, Coptis chinensis, and Pusatilla chinensis, effective results were obtained from the chloroform extract. In addition, fungal growth inhibition experiments were performed on unicellular fungi, Candida albicans, Candida tropicalis, and Candida lusitaniae, and on filamentous fungi, such as Pythium ultimum, Aspergillus fumigatus, and Fusarium oxysporum, using disk diffusion experiments on solid media. It was confirmed that P. chinensis extract has excellent antifungal properties against Candida spp. and C. apiifolia extract against filamentous mold. Finally, GC-MS analysis was performed to explore the useful antifungal substances present in the extract. As a result of the study, thurbergenone from C. apiifolia and 16-hydroxycleroda-3, 13(14)-dien-15, 16-olide (16-HCDO) from C. chinensis were confirmed as antifungal candidates. In conclusion, it was confirmed that C. apiifolia, C. chinensis, and P. chinensis have antifungal activity against various fungi, and in GC-MS analysis, all herbal medicines were confirmed to have different antifungal candidates. These results indicate that the Ranunculaceae family has evolved in several directions for fungal resistance traits.

Development and Validation of an Analytical Method for Quinoxyfen in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 살균제 Quinoxyfen의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.140-147
    • /
    • 2019
  • An analytical method was developed for the determination of quinoxyfen in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted with 1% acetic acid in acetonitrile and water was removed by liquid-liquid partitioning with $MgSO_4$ (anhydrous magnesium sulfate) and sodium acetate. Dispersive solid-phase extraction (d-SPE) cleanup was carried out using $MgSO_4$, PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed by using LC-MS/MS in positive mode with MRM (multiple reaction monitoring). The matrix-matched calibration curves were constructed using six levels ($0.001-0.25{\mu}g/mL$) and the coefficient of determination ($R^2$) was above 0.99. Recovery results at three concentrations (LOQ, 10 LOQ, and 50 LOQ, n=5) were in the range of 73.5-86.7% with RSDs (relative standard deviations) of less than 8.9%. For inter-laboratory validation, the average recovery was 77.2-95.4% and the CV (coefficient of variation) was below 14.5%. All results were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for quinoxyfen determination in agricultural commodities. This study could be useful for the safe management of quinoxyfen residues in agricultural products.

Simultaneous determination of 11-nor-Δ9-carboxy-tetrahydrocannabinol and 11-nor-Δ9-carboxy-tetrahydrocannabinol-glucuronide in urine samples by LC-MS/MS and its application to forensic science (LC-MS/MS를 이용한 소변 중 11-nor-Δ9-carboxy-tetrahydrocannabinol 및 11-nor-Δ9-carboxy-tetrahydrocannabinol-glucuronide의 동시 분석 및 법과학적 적용)

  • Park, Meejung;Kim, Sineun
    • Analytical Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.259-266
    • /
    • 2021
  • Cannabis (Marijuana) is one of the most widely used drugs in the world, and its distribution has been controlled in South Korea since 1976. Identification of 11-nor-Δ9-carboxy-tetrahydrocannabinol (THCCOOH) in urine can provide important proof of cannabis use, and it is considered scientific evidence in the forensic field. In this study, we describe a simultaneous quantitative method for identifying THCCOOH and THCCOOH-glucuronide in urine, using simple liquid-liquid extraction (LLE), and liquid chromatography-tandem mass spectrometry (LC-MS/MS). THCCOOH-D3 and THCCOOH-glucuronide-D3 were used as internal standards. Validation results of the matrix effect, as well as recovery, linearity, precision, accuracy, process efficiency, and stability were all satisfactory. No carryover, endogenous or exogenous interferences were observed. The limit of detection (LOD) of THCCOOH and THCCOOH-glucuronide were 0.3 and 0.2 ng/mL, respectively. The developed method was applied to 28 authentic human urine samples that tested positive in immunoassay screening and gas chromatography/mass spectrometry (GC/MS) tests. The ranges of concentrations of THCCOOH and THCCOOH-glucuronide in the samples were less than LOQ~266.90 ng/mL and 6.43~2133.03 ng/mL, respectively. The concentrations of THCCOOH-glucuronide were higher than those of THCCOOH in all samples. This method can be effectively and successfully applied for the confirmation of cannabinoid use in human urine samples in the forensic field.

Validation of Analytical Method for Male Sex Hormone Monitoring in Urine due to the Chemical Castration (성충동약물치료 시행에 따른 소변 중 남성호르몬의 분석법 확립)

  • Jeong, Sujin;Baeck, Seungkyung;Park, Sunhye;Son, Kkonnip;Park, Yonghoon;Lee, Sangki
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.330-336
    • /
    • 2013
  • "The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.

Simultaneous Fluorimetric Determination of On-line Preconcentrated HANs, DCAD and TCAD by Using RPLC with a Postcolumn Derivatization System

  • Jung, Sung-Woon;Choi, Yong-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1783-1790
    • /
    • 2013
  • A simultaneous analytical method has been developed for the fluorimetric determination of haloacetonitriles (HANs) [dichloroacetonitrile (DCAN), trichloroacetonitrile (TCAN), dibromoacetonitrile (DBAN), haloacetamides [dichloroacetamide (DCAD), and trichloroacetamde (TCAD)] in drinking water by using the combined on-line perconcentration/reversed phase liquid chromatography (RPLC)-postcolumn detection system. This on-line perconcentration system was achieved by employing a precolumn packed with a commercial solid phase extraction (SPE) sorbent for the enrichment and purification of the target analytes. The haloacetonitriles and haloacetamides were separated on CN analytical column in a 7.5% methanol-0.02 M phosphate buffered mobile phase at pH 3. The column effluents were reacted with postcolumn reagents of ophthaldialdehyde (OPA) and sulfite ion at pH 11.5, to produce a highly fluorescent isoindole fluorophore, which were measured with a fluorescence detector. Under the optimized conditions for RPLC and the postcolumn derivatization system all of the coefficient of determination of the standard calibration curves for the target analytes were over 0.99 and had a linear range from 5 to 100 ${\mu}g/L$. The detection limits showed 1.6 ${\mu}g/L$ for DCAD, 0.1 ${\mu}g/L$ for TCAD, 0.6 ${\mu}g/L$ for DCAN, 1.6 ${\mu}g/L$ for TCAN and 1 ${\mu}g/L$ for DBAN, and the recoveries were ranged from 64 to 99% except for DCAD with precisions less than 4.9% in distilled water, and from 72(${\pm}4%$) to 116%(${\pm}2%$) in tap water.

Screening and detection of methylisothiazolinone and chloromethylisothiazolinone in cosmetics by UPLC-MS/MS

  • Lee, Ji Hyun;Paek, Ji Hyun;Park, Han Na;Park, Seongsoo;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.125-133
    • /
    • 2020
  • Methylisothiazolinone (MIT) and chloromethylisothiazolinone (CMIT) cause allergic contact dermatitis and are banned cosmetics ingredients, except in rinse-off products. However, their presence has been detected in cosmetics. We report a UPLC-tandem MS/MS screening method for their simultaneous determination in cosmetics. To facilitate extraction from various matrices, pretreatment methods were developed for each sample type. The method was optimized through a series of assessments, including specificity, LOD, LOQ, linearity, recovery, stability, precision, and accuracy. The LODs and LOQs for MIT ranged from 0.054 and 0.163 ㎍ mL-1 whereas those for CMIT ranged from 0.040 and 0.119 ㎍ mL-1. The linear correlation coefficients (r2) were higher than 0.999. Relative standard deviations (RSDs) for both intra- and inter-day measurements ranged from 0.3 ~ 13.6 %. Recoveries at three different concentrations were within 87.9 ~ 118.9 %. The RSD for stability measurements of spiked samples was within 7 %. These results confirm the suitability of the developed method for the simultaneous quantitation of MIT and CMIT in cosmetics. Samples of 320 color cosmetics, including eyeshadows, solid lipsticks, liquid lipsticks, and nail polishes were analyzed using the developed method, and two of them were found to contain both MIT and CMIT and one of them was found to contain only MIT. This data and the method will aid the regulation of ingredients used in cosmetics.