• Title/Summary/Keyword: Liquid Liquid Extraction

Search Result 1,075, Processing Time 0.028 seconds

Acute cocaine intoxication in a body packer

  • Park, Mee-Jung;Lim, Mi-Ae;Chung, Hee-Sun
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.103-106
    • /
    • 2006
  • A 35-year-old Perubian who suffered from grand mal seizures died in the aircraft on his way from the United States to Hongkong via Incheon international airport of Korea. While performing the autopsy, 115 packs made with double layer of transparent film and black plastic bag containing cocaine were found in the ileum and large intestine. Among of them, 3 packs were ruptured. To determine the concentration of cocaine and its metabolites, blood, urine, bile, liver, spleen, heart, kidney, brain and gastric contents were taken and toxicological analysis was performed. Gas chromatography/mass spectrometry (GC/MS) following liquid-phase extraction using chloroform:isopropanol (=9:1) and derivatization with bis(trimethylsilyl)-trifluoroacetamide (contains 1% trimethylchlorosilane) was performed. High levels of cocaine, benzoylecgonine (BE) and ecgonine methylester (EME) were found in the postmortem blood (0.96, 3.09 and $5.59{\mu}g/mL$) and urine (32.85, 145.35 and $53.17{\mu}g/mL$), respectively. Cocaine and its metabolites were also detected in all other biological specimen.

Measurement and Calculation of Excess Enthalpies for n-Hexane/Alkane series and NaOH/Water/Ethanol System using Isothermal Microcalorimeter (등온 미세열량계를 이용한 n-Hexane-알칸계 이성분 혼합물 및 NaOH/Water/Ethanol계의 과잉 엔탈피 측정 및 계산)

  • Choi, In Kyu;You, Seong-sik
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.660-667
    • /
    • 2017
  • Equilibrium data of the mixture is essential in the design and operation of separation equipment such as distillation or extraction in chemical processes. These equilibrium data can be obtained through experiments or by calculations using the known binary parameters and the thermodynamic models. Generally, to obtain these parameters, phase equilibrium experimental data such as gas-liquid and liquid-liquid are used. In this study, the excess enthalpy of the mixture was measured using the flow type microcalorimeter which is a simpler method than phase equilibria experiments, and the parameters of various theories were obtained by using this data. In order to investigate the relationship between carbon chain length, enthalpy and binary parameters in the alkane system, excess enthalpies for the n-hexane + alkane (n-pentane, n-heptane, n-octane and n-dodecane) were measured at 298.15 K and the banary interaction parameters of Wilson, NRTL, and UNIQUAC were obtained from the experimental data. In addition, we wanted to obtain basic information on the interaction and association phenomena of the system including electrolyte applicable to various fields by using the excess enthalpy experimental data and the existing theory. First, we investigated the excess enthalpy for the NaOH / Water / Ethanol system as a basic experiment and examined the applicability using the electrolyte-NRTL (eNRTL) theory.

Morroniside, Loganin, and Cornin Contents and Physicochemical Properties of Commercial Sansuyu (Corni fructus) Retort Drink (시중에 유통되고 있는 산수유 음료의 Morroniside, Loganin 및 Cornin 함량과 이화학적 특성)

  • Park, Su-Jin;Jeong, Ji-Suk;Jeong, Jae-Hun;Park, No-Jin;Son, Byeong-Gil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.8
    • /
    • pp.1018-1025
    • /
    • 2017
  • The present study collected 18 kinds of commercially circulated liquid Sansuyu (Corni fructus) in pouch form and conducted comparative analysis on markings and physicochemical characteristics in order to utilize this information as a base material for the development of Sansuyu liquid products. The most abundant valid substance was morroniside, followed by loganin and cornin, in that order. Total concentration of valid substances in Cornus fruit products produced in the Gurye region was 168.50 mg/100 g, which was significantly higher than the overall average of 130.89 mg/100 g. There were seven (1st) and seven (2nd) kinds that contained more morroniside than the overall average, six (1st) and four (2nd) kinds with more loganin than the overall average, and eight (1st) and one (2nd) kinds with more cornin than the overall average. There were also five types in which no loganin was detected. There were significant differences in the valid substances of most products according to production period. Overall, these results show that processing method standardization research on extraction conditions is needed to produce liquid Sansuyu products of excellent quality.

Determination of Heterocyclic Amines and Acrylamide in Agricultural Products with Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Kyung-Jun;Lee, Gae-Ho;Kim, HaeSol;Oh, Min-Seok;Chu, Seok;Hwang, In Ju;Lee, Jee-yeon;Choi, Ari;Kim, Cho-il;Park, Hyun-Mee
    • Toxicological Research
    • /
    • v.31 no.3
    • /
    • pp.255-264
    • /
    • 2015
  • Heterocyclic amines (HCAs) and acrylamide are unintended hazardous substances generated by heating or processing of foods and are known as carcinogenic and mutagenic agents by the animal experiments. A simple method was established for a rapid and accurate determination of 12 types of HCAs (IQ, MeIQ, Glu-P-1, Glu-P-2, MeIQx, Trp-P-1, Trp-P-2, PhIP, $A{\alpha}C$, $MeA{\alpha}C$, Harman and Norharman) and acrylamide in three food matrices (non-fat liquid, non-fat solid and fat solid) by isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS). In every sample, a mixture of internal standards including $IQ-d_3$, $MeIQx-d_3$, $PhIP-d_3$, $Trp-P-2-^{13}C_2-^{15}N$ and $MeA{\alpha}C-d_3$ was spiked for quantification of HCAs and $^{13}C_3$-acrylamide was also spiked for the analysis of acrylamide. HCAs and acrylamide in sample were extracted with acetonitrile and water, respectively, and then two solid-phase extraction cartridges, ChemElut: HLB for HCAs and Accucat: HLB for acrylamide, were used for efficiently removing interferences such as pigment, lipid, polar, nonpolar and ionic compounds. Established method was validated in terms of recovery, accuracy, precision, limit of detection, limit of quantitation, and linearity. This method showed good precision (RSD < 20%), accuracy (71.8~119.1%) and recovery (66.0~118.9%). The detection limits were < 3.1 ng/g for all analytes. The correlation coefficients for all the HCAs and acrylamide were > 0.995, showing excellent linearity. These methods for the detection of HCAs and acrylamide by LC-MS/MS were applied to real samples and were successfully used for quantitative monitoring in the total diet study and this can be applied to risk assessment in various food matrices.

Development and validation of an analytical method for the determination of lepimectin residues by HPLC-PDA (HPLC-PDA를 이용한 lepimectin 잔류량 분석법 개발 및 확인)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.142-153
    • /
    • 2013
  • A new, rapid, and simple analytical method was developed and validated using high performance liquid chromatograph-photodiode array detector (HPLC-PAD) for the determination of lepimectin residues in agricultural commodities. The lepimectin residues in samples were extracted with methanol, partitioned with dichloromethane, and then purified with glass column filled with subsequently to aminopropyl ($NH_2$) solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-PAD. Correlation coefficient ($R^2$) of both lepimectin $A_3$ and $A_4$ solutions were 0.9999. The method was validated using cucumber spiked with lepimectin at 0.02 and 0.2 mg/kg and pepper, mandarin, hulled rice, potato, soybean at 0.02 and 0.5 mg/kg. Average recoveries were 76.0~114.8% with relative standard deviation less than 10%, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.01 mg/kg, respectively. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional KFDA and Daejeon regional KFDA was followed with Codex guideline (CAC/GL 40). Therefore, developed method in this study is accurate, rapid, and appropriate for lepimectin determination and will be used to keep safety of lepimectin residues in agricultural products.

HPLC Analysis and Pharmacokinetics of KAL-1120, a Novel Anti-inflammation Agent, in Rats (흰쥐에서 항염증제 후보물질 KAL-1120의 HPLC 분석 및 약물동태)

  • Shin, Dae-Hwan;Lee, Jung-Yeol;Park, Seong-Hyeok;Lee, Gyeong-Bok;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of N-(-4-Chlorophenyl)-6-hydroxy-7-methoxy-2-chromanecarboxamide (KAL-1120), a novel anti-inflammation agent, in the rat plasma. The method was applied to analyze the compound in the biological fluids such as bile, urine and tissue homogenates. After liquid-liquid extraction, the compound was analyzed on an HPLC system with ultraviolet detection at 275 nm. HPLC was carried out using reversed-phase isocratic elution with a $C_{18}$ column, a mobile phase of a mixture of acetonitril (40 v/v%) at a flow rate of 1.0 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma was linear over the concentration range of 0.05-50 ${\mu}g$/mL. The intra- and inter-day assay accuracies of this method ranged from 0.06% to 9.33% of normal values and the precision did not exceed 6.28% of relative standard deviation. The plasma concentration of KAL-1120 decreased to below the quantifiable limit at 1.5 hr after the i.v. bolus administration of 2-10 mg/kg to rats ($t_{1/2,({\alpha})}$ and $t_{1/2,({\beta})$ of 2.15 and 26.7 min at a dose of 2 mg/kg, 3.91 and 33.0 min at a dose of 10 mg/kg, respectively). The steady-state volume of distribution ($V_{dss}$) and the total body clearance ($CL_t$) were not significantly altered in rats given doses from 2 to 10 mg/kg. Of the various tissues tested, KAL-1120 was mainly distributed in the lung and heart after i.v. bolus administration. KAL-1120 was detected in the bile by 30 min after its i.v. bolus administration. However, the concentration in the urine after i.v. bolus administration became too low to measure, suggesting that KAL-1120 is mostly excreted in the bile. In conclusion, this analytical method was suitable for the preclinical pharmacokinetic studies of KAL-1120 in rats.

Lipid Composition of Barley Flour Produced in Korea (한국산(韓國産) 보리가루의 지방질(脂肪質) 조성(組成))

  • Chun, Hye-Kyung;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.51-58
    • /
    • 1984
  • Grains of naked barley (Baekdong cultivar) were polished, powdered and subjected to the successive extraction into free and bound liquid fractions. These were further fractionated into lipid classes and quantified by means of thin layer chromatography, column chromatography and gas-liquid chromatography. Contents of free and bound lipids in barley flour were 2.27% and 1.01%, which were decreased to 2.12% and 0.76%, respectively, after purification. Free and bound lipids were consisted of monoglycerides, diglycerides, triglycerides, free sterols, sterol esters, free fatty acids and polar lipids. Major constituents of free lipids were 56.2% triglycerides, 14.9% free fatty acids and 13.4% sterols while those of bound lipids were 73.8% polar lipids, 8.4% free fatty acids and 5.2% triglycerides. The content of non-polar lipids in free lipids was 93.6% as compared with 26.2% in bound lipids. However, phospholipids content in bound lipids was 55.5% as compared with 2.5% in free lipids, and glycolipids content in bound lipids was 19.4% as compared with 3.9% in free lipids. Major fatty acids in the free and bound lipid fractions were linoleic acid 52.1%, 54.8%, palmitic acid 24.8%, 30.0% and oleic acid 15.6%, 8.8%, respectively, showing similar patterns in both fractions. The amount of unsaturated fatty acids in free lipids was 72.8% as compared with 68.0% in bound lipids. In comparing the fatty acid composition of non-polar lipids, glycolipids and phospholipids, no difference was observed between free and bound lipid fractions while a slight difference was found among the lipid constituents.

  • PDF

Validation of the LC-MS/MS Method for Ginsenoside Rb1 Analysis in Human Plasma (LC-MS/MS를 이용한 인체 혈장에서 Ginsenoside Rb1의 분석법 검증)

  • Han, Song-Hee;Kim, Yunjeong;Jeon, Ji-Young;Hwang, Minho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1753-1757
    • /
    • 2012
  • A new liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay for the quantification of ginsenoside Rb1 in human plasma was developed and validated. The separation was performed on a Agilent C18 column ($4.6mm{\times}150mm$, particle size 5 ${\mu}m$) with a gradient elution of 0.1% formic acid in water and 0.1% formic acid in methanol and a flow rate of 0.9 mL/min. The analyte was determined using electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode (m/z 1131.714${\rightarrow}$365.303). Human plasma samples were extracted with acetone : water (50:50) by the liquid-liquid extraction method. The method was linear over the dynamic range of 10~500 ng/mL with a correlation coefficient of r=0.9995. The intra-and inter-day precision over the concentration range of ginsenoside Rb1 was lower than 5.8% (correlation of variance, CV), and the accuracy was between 96.0~104.6%. This LC-MS/MS assay of ginsenoside Rb1 in human plasma is applicable for quantification in a pharmacokinetic study.

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • A rapid, sensitive analytical method for glucuronolactone in beverages was developed and validated using hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HILIC-ESI-MS/MS). To determine the optimum analytical conditions for glucuronolactone, three different kinds of HILIC columns and two mobile phases with different pH values were examined. An amide-bonded stationary phase with a pH 9 acetonitrile-rich mobile phase was the best condition in terms of column retention, ESI-MS/MS response area, and signal-to-noise ratio. After extraction, glucuronolactone was separated through the HILIC amide column and detected by negative ESI-MS/MS in selected reaction monitoring (SRM) mode. Nine energy drinks sold in Korea were spiked with glucuronolactone at a concentration of 5 ng/mL; the Monster $Energy^{TM}$ sample showed the smallest peak area and its signal-to-noise ratio was used for method validation. Good linearity was obtained in the concentration range from 20 to 1500 ng/mL with a correlation coefficient > 0.998. The developed method had a limit of detection (LOD) of 6 ng/mL and a limit of quantitation (LOQ) of 20 ng/mL. The recovery of this method at concentration of 20, 100, 500, and 1000 ng/mL was 96.3%-99.2% with relative standard deviations (RSD) of 1.6%-14.0%. A reproducibility precision assessment at concentration of 100 and 500 ng/mL was carried out among three laboratories. The recovery of that evaluation was 95.1%-102.3% with RSD of 2.7%-7.0%. An analysis of variance indicated that there was no difference between the recovery results of the three laboratories at the 5% significance level. The validated method is applicable to inspecting beverages adulterated with glucuronolactone in Korea.

Determination of Siderophore from Bacillus Mojavensis Using Liquid Chromatography quadrupole Time-of-flight Tandem Mass Spectrometry (액체크로마토그래피-사중극 비행시간형 탠덤질량분석기를 이용한 Bacillus mojavensis 균주 속 사이드로포어 규명)

  • Cheon, Hae In;Yeo, Mi Seon;Kim, Kang Min;Kang, Jae Seon;Pyo, Jaesung
    • Journal of Life Science
    • /
    • v.29 no.2
    • /
    • pp.198-201
    • /
    • 2019
  • Recently, it has been reported that Bacillus mojavensis possesses antifungal properties and plant growth-promoting activities, which are similar to the characteristics of siderophore. In this study, the siderophore produced by B. mojavensis was assessed using a solid phase extraction (SPE) cartridge and liquid chromatography quadrupole time-of-flight tandem mass spectrometry (Q-TOF MS/MS). After B. mojavensis was incubated in phenol medium for 16 hr and lyophilized, the sample was dissolved in water and loaded to an SPE cartridge to remove interferences. The cartridge was washed with 5% methanol in water and eluted with 2% formic acid in methanol sequentially. The eluted solution was evaporated under a stream of nitrogen gas and reconstituted in methanol. The reconstituted sample was filtered, and $1{\mu}l$ of the sample was assessed using Q-TOF MS/MS. The mass spectrometer was operated using the positive electrospray ionization mode. Based on the mass spectrum and tandem mass spectrum, the siderophore produced by B. mojavensis was bacillibactin, one of the catechol types of siderophore with a molecular weight of 882.2556. This siderophore analysis could provide a justification for the study of B. mojavensis as a functional food and for pharmaceutical applications.