• Title/Summary/Keyword: Liquid Liquid Extraction

Search Result 1,075, Processing Time 0.028 seconds

Rapid High Performance Liquid Chromatographic Quantification of Major Isoflavones in Soybeans and Soybean Pastes

  • Kim, Won-Chan;Kwon, Soon-Ho;Rhee, In-Koo;Hur, Jong-Moon;Jeong, Hyun-Hee;Choi, Sun-Ha;Lee, Kyung-Bok;Kang, Young-Hwa;Song, Kyung-Sik
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.24-27
    • /
    • 2006
  • A simple HPLC quantification method was developed for genistein, genistin, daidzein, and daidzin in soybeans and soybean products. The procedure used a $4.6{\times}100\;mm$ $Chromolith^{(R)}$ RP-18e column with a mobile phase of 1% HOAc in 20% MeOH to 1% HOAc in 80% MeOH for 10 min. The injection volume was $2\;{\mu}L$ at a flow rate of 2 mL/min. Detection was carried out under UV at 254 nm. Under these conditions, the major isoflavones daidzein, daidzin, genistein, and genistin in soybean and soybean pastes were eluted within 7 min with baseline separation. Optimal extraction of the above four major isoflavones was achieved when 40 g of soybean or soybean paste was refluxed in 100 mL of 95% ethanol for 2 hr. Ten different soybean cultivars and nine commercial soybean pastes were analyzed by this method. The total isoflavone content was highest in the cultivar Somyung ($2,497\;{\mu}g/g$ dry weight). The isoflavone content in soybean pastes varied widely from manufacturer to manufacturer (an almost five-fold difference between the highest and lowest values). Such variations were presumably due to differences in fermentation conditions, type of soybeans used, and levels of such additives as starch and salt.

Characterization of the Outer Membrane-Associated 2-Furaldehyde Dehydrogenase from Klebsiella pneumoniae (Klebsiella pneumoniae 균주의 세포외막에서 분리한 2-furaldehyde dehydrogenase의 특성에 관한 연구)

  • 이준우;강사욱;하영칠;한홍의
    • Korean Journal of Microbiology
    • /
    • v.26 no.3
    • /
    • pp.197-206
    • /
    • 1988
  • An outer membrane-associated 2-furaldehyde dehydrogenase, catalyzing the oxidation of 2-furaldehyde to 2-furoic acid from Klebsiella pneumoniae was purified to homogeneity and characterized. The enzyme showed its highly specific dependency on $\beta$-$NAD^{+}$. Enzyme activity was monitored during purification by using substrate 2-furaldehyde and coenzyme $\beta$-$NAD^{+}$ by means of high performance liquid chromatography. The outer membrane was successfully collected by the methods of Percoll density gradient ultracentrifugation and ultracentrifugation after preferential solubilization of the membrane with $Mg^{2+}$ and Triton X-100. The enzyme was purified by the series of procedures including extraction of outer membrane protein with EDTA and lysozume, and fractionation by column chromatography on QAE-Sephades Q-50, and subsequently Sephadex G-100. The enzume showed its optimal activity at $85^{\circ}C$, pH 9.5, and in the presence of 1.5% (vol/vol) Triton X-100. The enzyme exhibited a native molecular size of 88,000 by nondenaturing polyacrylamide gel electrophoresis and had an apparent Km of 4.72mM for 2-furaldehyde.

  • PDF

Inhibitory Effects of Brown Algae Extracts on Histamine Production in Mackerel Muscle via Inhibition of Growth and Histidine Decarboxylase Activity of Morganella morganii

  • Kim, Dong Hyun;Kim, Koth Bong Woo Ri;Cho, Ji Young;Ahn, Dong Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.4
    • /
    • pp.465-474
    • /
    • 2014
  • This study was performed to investigate the inhibitory effects of brown algae extracts on histamine production in mackerel muscle. First, antimicrobial activities of brown algae extracts against Morganella morganii were investigated using a disk diffusion method. An ethanol extract of Ecklonia cava (ECEE) exhibited strong antimicrobial activity. The minimum inhibitory concentration (MIC) of ECEE was 2 mg/ml. Furthermore, the brown algae extracts were examined for their ability to inhibit crude histidine decarboxylase (HDC) of M. morganii. The ethanol extract of Eisenia bicyclis (EBEE) and ECEE exhibited significant inhibitory activities (19.82% and 33.79%, respectively) at a concentration of 1 mg/ml. To obtain the phlorotannin dieckol, ECEE and EBEE were subjected to liquid-liquid extraction, silica gel column chromatography, and HPLC. Dieckol exhibited substantial inhibitory activity with an $IC_{50}$ value of 0.61 mg/ml, and exhibited competitive inhibition. These extracts were also tested on mackerel muscle. The viable cell counts and histamine production in mackerel muscle inoculated with M. morganii treated with ${\geq}2.5 $ MIC of ECEE (weight basis) were highly inhibited compared with the untreated sample. Furthermore, treatment of crude HD-Cinoculated mackerel muscle with 0.5% ECEE and 0.5% EBEE (weight basis), which exhibited excellent inhibitory activities against crude HDC, reduced the overall histamine production by 46.29% and 56.89%, respectively, compared with the untreated sample. Thus, these inhibitory effects of ECEE and EBEE should be helpful in enhancing the safety of mackerel by suppressing histamine production in this fish species.

High Speed Separation of PFCs in Human Serum by C18-Monolithic Column Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Won-Woong;Lee, Sun-Young;Yu, Se Mi;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3727-3734
    • /
    • 2012
  • An analytical method has been developed for the rapid determination of perfluorinated compounds (PFCs) in human serum samples. The extraction and purification of PFCs from human serum were performed by the modified method of previous report. Ten PFCs were rapidly separated within 3.3 min by C18-monolithic column liquid chromatography (LC) and detected by electrospray ionization (ESI) tandem mass spectrometry (MS/MS) in negative ion mode. The runtime of PFCs on monolithic column LC was up to 4-fold faster than that on conventional column LC. The effect of triethylamine (TEA) to the mobile phase has investigated on the overall MS detection sensitivity of PFCs in ESI ionization. Quantification was performed by LC-MS/MS in multiple-ion reaction monitoring (MRM) mode, using $^{13}C$-labeled internal standards. Method validation was performed to determine recovery, linearity, precision, and limits of quantification, followed by, the analysis of a standard reference material (SRM 1957 from NIST). The overall recoveries ranged between 81.5 and 106.3% with RSDs of 3.4 to 16.2% for the entire procedure. The calibration range extended from 0.33 to 50 $ng\;mL^{-1}$, with a correlation coefficient ($R^2$) greater than 0.995 and the limits of quantification with 0.08 to 0.46 $ng\;mL^{-1}$. This approach can be used for rapid and sensitive quantitative analysis of 10 PFCs in human serum with high performance and accuracy.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

Urinary Profiling of Endogeneous Estrogens Using GC/MS (GC/MS에 의한 뇨 중 내인성 에스트로겐의 Profiling)

  • Lee, Seon Hwa;Yang, Yoon Jung;Kim, Tae Wook;Paeng, Ki Jung;Chung, Bong Chul
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.4
    • /
    • pp.186-197
    • /
    • 1997
  • Estrogens, which play an important role in sex hormone and potential inhibitor of cancer cell proliferation were profiled for normal female and male. The nineteen endogeneous estrogens were simultaneously analyzed by selected ion monitoring method of GC/MS. Urinary estrogens were extracted by using Serdolit AD-2 resin, hydrolyzed with $\beta-glucuronidase/arylsulfatase$ from Helix pomatia, liquid-liquid extraction and quantitatively derivatized by MSTFA/TMSCl mixture in order to be detected on the GC/MS. The good quality-control data were obtained through the precision and accuracy test and the recovery range of them was 80.97∼97.81%. The Korean reference values of urinary estrogens were established and differences were found in normal female compared with normal male.

  • PDF

HPLC Determination and Steady-State Bioavailability Study of Levodropropizine Sustained-release Tablets in Dogs

  • Yan, Lin;Li, Tongling;Zhang, Rongqin;Xu, Xiaohong;Zheng, Pengcheng
    • Archives of Pharmacal Research
    • /
    • v.29 no.6
    • /
    • pp.514-519
    • /
    • 2006
  • A simple HPLC method using UV detection was developed and validated for the determination of levodropropizine (LDP) In dog plasma. The sample was prepared for injection using a liquid-liquid extraction method with 1-phenypiperazine as the internal standard. The mobile phase was methanol - diethylamine solution (0.05 M) (20:80, v/v, pH adjusted to 3.0 with $H_3PO_4$) with a detection wavelength of 240 nm. The limit of quantitation (LOQ) of LDP in a biological matrix was determined to be 25.25 ng/mL. The calibration curve was linear across the concentration range of 25.25 to 2020 ng/mL. The intra-day and inter-day precision values (CV%) were within 7% and accuracy (R.E. %) was within 6% of the nominal values for medium (252.5 ng/mL) and high (2020 ng/mL) LDP concentrations. For the LDP concentration at the LOQ, the intra-day and inter-day precision and accuracy were within 20% and 10%, respectively. The average absolute recovery for LDP was 70.28%. This method was successfully used to analyze plasma samples in a steady-state bioavailability study of a newly developed sustained-release LDP tablets (SR) using immediate-release tablets (IR) as the reference. The relative bioavailability of the SR was determined to be $106.3\;{\pm}\;12.8%$ (n=6). The $C_{max}$ of the SR was significantly lower (p<0.05), and the $t_{max}$ was significantly longer than that of the IR (p<0.05). The results of ANOVA and two one-sided tests indicated that the SR exhibited acceptable sustained release properties and was bioequivalent to the IR.

Determination of Ketorolac in Human Serum by High-performance Liquid Chromatography

  • Chun, In-Koo;Kang, Hyun-Hee;Gwak, Hye-Sun
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.529-534
    • /
    • 1996
  • A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of ketorolac in human serum using a new extraction method with a good recovery. Human serum samples (1.0 ml) spiked with known concentrations of ketorolac tromethamine and 10${\mu}g$ of ketoprofen as the internal standard (IS) were acidified with 200${\mu}l$ of 1 N HCl and extracted with 7 ml of n-hexane-ether (7:3 v/v). Extracts were centrifuged and organic layer was back-extracted with 400${\mu}l$ of 0.1% tromethamine solution. Twenty .mu.l of centrifuged aqueous layer was injected onto a reversed-phase octyl column and eluted with a mixture of acetonitrile, water, methanol, and triethylamine [35:55:10:0.1 (v/v), pH 3.0] at a flow rate of 1.0 ml/min. Ultraviolet detection of ketorolac and IS was carried out at 300 nm. The calibration curve obtained using peak area ratios showed a good linearity (in concentration range 10-150 ng/ml $r^2$=O.9944; in range 50-2000 ng/ml, r$^{2}$=0.9998). The mean intra-day accuracy and precision for this HPLC method were found to be 3.6 and 3.7%, respectively. The mean inter-day accuracy and precision were found to be 4.0 and 3.7%, respectively, in the concentration range 50-2000 ng/ml. The recovery of ketorolac from serum was 92.0 $({\pm}5.7)$ % at the concentration of 100 ng/ml. This method proved to be readily applicable to the assay of ketorolac in human serum.

  • PDF

The Changes of Aroma in Wine Treated with Reverse Osmosis System (역삼투압 시스템으로 처리한 포도주의 향기성분 변화)

  • Lee, Seung-Ryong;Lee, Kyu-Hee;Chang, Kyu-Seob;Lee, Suk-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.17-24
    • /
    • 2000
  • Reverse osmosis (RO) system was applied to improve wine quality. General wine (GEN) and wines containing different sugar levels $24^{\circ}Brix$ (RO-24) and $24^{\circ}Brix$ (RO-28) by removing pure water using RO system without sugar addition on brewing method. And they were compared by wine aroma analysis. The preparing method of analysis was LLCE (liquid-liquid continuous extraction). And volatile aroma compounds of different wines were prepared for raw, and diluted materials in same proportion. The wine aromas were described by trained twelve panelists for QDA (quantitative descriptive analysis) and showed for FD (flavor dilution)-chromatogram. Consequently, overall acceptability of RO-28 showed better than that of other treatments. Aromas of RO-28 also were represented the high contents of positive aroma compounds such as ethanol and ethyl acetate, which were identified by GC-O and GC-MS.

  • PDF

Quantitative Analysis of Rotenone and Deguelin in Biopesticides Containing Derris Extract by Ultra performance Liquid Chromatography (UPLC를 활용한 데리스 추출물 함유 유기농자재 중 Rotenone과 Deguelin 정량분석)

  • Lim, Sung-Jin;Kim, Jin-Hyo;Choi, Geun-Hyoung;Park, Byung-Jun
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.1
    • /
    • pp.52-56
    • /
    • 2015
  • BACKGROUND: Three commercial biopesticides containing derris extract, which is permitted as a commercial biopesticide substances by the Environmentally-friendly Agriculture Promotion Act, have been marketed in Korea. But, the quantitative analytical method of active substances for crop protection in biopesticides containing derris extract has not known. METHODS AND RESULTS: Solid phase extraction (SPE) cartridge clean-up method for the quantitative analysis of rotenone and deguelin in biopesticides containing derris extract was developed and validated by ultra-performance liquid chromatography (UPLC). The clean-up method was established using hydrophilic lipophilic balance (HLB) SPE cartridges for the bioactive substances in biopesticides containing derris extract, and the eluate was analyzed to quantify the rotenone and deguelin by the UPLC. LOQ and recovery rates of rotenone and deguelin were 0.085 and 0.044 mg/L, 95.7 and 93.3%, respectively. The content of rotenone and deguelin in three biopesticides containing derris extract were analyzed by the developed method, the results showed 0.001-0.236 and