• Title/Summary/Keyword: Liquid Liquid Extraction

Search Result 1,075, Processing Time 0.027 seconds

Efficient removal of radioactive waste from solution by two-dimensional activated carbon/Nano hydroxyapatite composites

  • El Said, Nessem;Kassem, Amany T.
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.327-334
    • /
    • 2018
  • The nano/micro composites with highly porous surface area have attracted of great interest, particularly the synthesis of porous and thin film sheets of high performance. In this paper, an easy method of cost-effective synthesis of thin film ceramic fiber membranes based on Hydroxyapatite, and activated carbon by turned into studied to be applied within the service-facilitated the transport of radioactive waste such as $^{90}Sr$, $^{137}Cs$ and $^{60}Co$) as activated product of radioisotopes from ETRR-2 research reactor and dissolved in 3M $HNO_3$, across a thin flat-sheet supported liquid membrane (TFSSLM). Radionuclides are transported from alkaline pH values. The presence of sodium salts in the aqueous media improves in $HNO_3$, the lowering of permeability because the initial $HNO_3$ concentration is improved. The study some parameters on the thin sheet ceramic supported liquid membrane. EDTA as stripping phase concentration, time of extraction and temperature were studied. The study of maximum permeability of radioisotopes for all parameters. The pertraction of a radioactive waste solution from nitrate medium were examined at the optimized conditions. Under the optimum experimental 98.6-99.9% of $^{90}Sr$, 79.65-80.3% of $^{137}Cs$ and $^{60}Co$ 45.5-55.5% in 90-110 min with were extracted in 10-30 min, respectively. The process of diffusion in liquid membranes is governed by the chemical diffusion process.

Determination of Residual Erythromycin Antibiotic in Fishery Products by Liquid Chromatography-electrospray Ionization Mass Spectrometry (LC-MS/MS를 이용한 어류 및 갑각류의 잔류 Erythromycin 항생제 분석)

  • Jo, Mi-Ra;Mok, Jong-Soo;Lee, Doo-Seog;Kim, Min-Jung;Kim, Poong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.1
    • /
    • pp.15-19
    • /
    • 2009
  • A simple and sensitive method for erythromycin quantification by liquid chromatography electrospray mass spectrometry (LC-MS/MS) in fishery products was developed. Samples were extracted by liquid-liquid extraction using 70% acetonitrile. Lipids were removed by acetonitrile saturated hexane. LC separation was performed on a Shiseido UG C-18 column ($150\;mm{\times}2.0\;mm$ internal diameter.) with a gradient system of 0.2% acetic acid-acetonitrile containing 0.2% acetic acid as a mobile phase at flow rate of 0.2 mL/min. The mass spectrometer was operated in selected reaction monitoring with positive electro-spray interface. Transitions were monitored a m/z $734{\to}577$ and $734{\to}158$, with m/z $734{\to}577$ chosen for quantification. Recovery of erythromycin from fish and shrimp fortified at the 10 ng/mL, 50 ng/mL and 100 ng/mL were 91.6-109.4%, 84.4-111.2% and 98.8-109.6% with high precision, respectively. Limits of quantification and limits of detection of erythromycin in both fish and shrimp were 10.0 ng/mL and 1.0 ng/mL, respectively. This analysis method for erythromycin has been proposed for registration in the Korean Official Methods of Food Analysis and has been utilized for fishery products analysis by the Korea Food and Drug Adminstration and the National Fisheries Products Quality Inspection Service.

Characteristics of Icing Phenomenon with Droplet of an Injector for Liquid Phase LPG Injection System (LPG 액상분사식 인젝터에서 후적에 의한 아이싱 특성 연구)

  • Park, Cheol-Woong;Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.9-16
    • /
    • 2007
  • Since the liquid phase LPG injection(LPLI) system has an advantage of higher power and lower emission characteristics than the mixer type fuel supply system, many studies and applications have been conducted. However, the heat extraction, due to the evaporation of liquid fuel, causes not only a dropping of LPG fuel but also icing phenomenon that is a frost of moisture in the air around the nozzle tip. Because both lead to a difficulty in the control of accurate air fuel ratio, it can result in poor engine performance and a large amount of HC emissions. The experimental investigation was carried out on the bench test rig in this study. It was found that n-butane, that has a relatively high boiling point($-0.5^{\circ}C$), was a main species of droplet composition and also found that the droplet problem was improved by the use of a large inner to outer bore ratio nozzle whose surface roughness is smooth. The icing phenomena were decreased when the an engine head temperature was increased, although a large amount of icing deposit was still observed in the case of $87^{\circ}C$. Also, it was observed that the icing phenomenon is improved by using anti-icing bushing.

A Study on the Analysis of 89Sr and 90Sr with Cerenkov Radiation and Liquid Scintillation Counting Method (첼렌코프광과 액체섬광계수법을 이용한 89Sr 및 90Sr 분석에 대한 연구)

  • Lee, Myung-Ho;Chung, Geun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • An accurate and simple analytical technique for $^{89}Sr$ and $^{90}Sr$, overcoming the demerits of the conventional method, has been developed with extraction chromatography and liquid scintillation counting. The Sr fraction was separated from hindrance elements with oxalate coprecipitation or cation exchange resin and purified with Sr-Spec column. With liquid scintillation counter, $^{89}Sr$ was measured by Cerenkov radiation method, and $^{90}Sr$ was measured by spectrum unfolding method. The developed radioactive strontium separation method was validated by application to the IAEA-reference material (IAEA-375, Soil) and radioactive waste samples.

Determination of Methoxyfenozide Residues in Water and Soil by Liquid Chromatography: Evaluation of its Environmental Fate Under Laboratory Conditions

  • Choi, Jeong-Heui;Mamun, M.I.R.;Shin, Eun-Ho;Kim, Hee-Kwon;El-Aty, A.M. Abd;Shim, Jae-Han
    • Toxicological Research
    • /
    • v.24 no.3
    • /
    • pp.207-212
    • /
    • 2008
  • Pesticide residues play several key roles as environmental and food pollutants and it is crucial to develop a method for the rapid determination of pesticide residues in environments. In this study, a simple, effective, and sensitive method has been developed for the quantitative analysis of methoxyfenozide in water and soil when kept under laboratory conditions. The content of methoxyfenozide in water and soil was analyzed by first purifying the compound through liquid-liquid extraction and partitioning followed by florisil gel filtration. Upon the completion of the purification step the residual levels were monitored through high performance liquid chromatography(HPLC) using a UV absorbance detector. The average recoveries of methoxyfenozide from three replicates spiked at two different concentrations and were ranged from 83.5% to 110.3% and from 98.1% to 102.8% in water and soil, respectively. The limits of detection(LODs) and limits of quantitation(LOQs) were 0.004 vs. 0.012 ppm and 0.008 vs. 0.024 ppm, respectively. The method was successfully applied to evaluate the behavioral fate of a 21% wettable powder(WP) methoxyfenozide throughout the course of 14 days. A first-order model was found to accurately fit the dissipation of methoxyfenozide in water with and a $DT_{50}$ value of 3.03 days was calculated from the fit. This result indicates that methoxyfenozide dissipates rapidly and does not accumulate in water.

Extraction of Short Peptide Using Supported Liquid Membranes (Supported Liquid Membrane을 이용한 Short Peptide의 추출)

  • Lee, Jae-Heung;Park, Ki-Moon
    • Food Science of Animal Resources
    • /
    • v.25 no.3
    • /
    • pp.340-343
    • /
    • 2005
  • The objective of this work was to study separation of short peptide (glycine-tyrosine) by using supported liquid membranes (SLMs) containing Aliquat as a cationic carrier, In the present investigation, the influence of pH of donor phase, concentrations of carrier and salt concentrations of acceptor phase on separation flux rate were investigated. Below pH 7.0 the flux rate was not affected by NaCl concentration or carrier concentration. However, the rate was increased significantly above pH 7.0. The rate with Hossain's SLM(H-SLM) containing $20\%$ Aliquat was about 3-fold higher with pH 9.0 at 0.25 M NaCl and 10-fold higher with pH 8.0 at 1.0 M NaCl than that with Duggan's SLM(D-SLM) containing $8\%$ Aliquat respectively. Furthermore, the rate with H-SLM was 10-fold higher at 1.0 M NaCl than the rate with 0.25 M NaCl, In conclusion, it would appear that the rate of separation was facilitated by using high salt concentrations together with high carrier concentrations above pH 7.0.

Determination of nadolol enantiomers in human plasma using a coupled achiral-chiral high-performance liquid chromatography method

  • Lee, Seung-Beom;Pham, Thuy-Vy;Mai, Xuan-Lan;Le, Thi-Anh-Tuyet;Nguyen, Thi-Ngoc-Van;Kang, Jong-Seong;Mar, Woongchon;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.59-67
    • /
    • 2020
  • Nadolol is a β-blocker drug, which effectively manages hypertension and angina pectoris. Its chemical structure allows the formation of four possible stereoisomers. A coupled column high-performance liquid chromatographic (HPLC) system with UV and fluorescence detection was investigated for simultaneously determining four nadolol enantiomers in human plasma. The plasma samples were prepared using a convenient liquid-liquid extraction process and passed through HPLC. Nadolol was initially separated from the endogenous compounds or other impurities in human plasma on a Phenomenex silica column, and its enantiomers were resolved and determined on a Chirapak AD-H column. The developed HPLC method achieved an effective chiral separation and significantly eliminated endogenous compound interference. This optimal HPLC method was validated following FDA guidelines. The results showed good selectivity, linearity, accuracy (90.50 % - 105.27 %), and precision (RSDs < 9.52 %) for each enantiomer. This method was also successfully applied to determine nadolol enantiomers in the plasma samples of a healthy male volunteer (after orally administering 80 mg racemic nadolol), proving its suitability for nadolol stereoselective pharmacokinetic studies.

Icing Characteristics in Liquid-Phase Injection of LPG Fuel (액상분사식 LPG 인젝터의 아이싱 생성 특성 및 억제 방법)

  • Lee, Sun-Youp;Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.14 no.4
    • /
    • pp.147-152
    • /
    • 2009
  • Since a liquid-phase LPG injection system allows accurate control of fuel injection and increase in volumetric efficiency, it has advantages in achieving higher engine power and lower emissions compared to the mixer type LPG supplying system. However, this system also leads to an unexpected event called icing phenomenon which occurs when moisture in the air near the injector freezes and becomes frost around the nozzle hole due to extraction of heat from surrounding caused by instant fuel vaporization. As a result, it becomes difficult to control air/fuel ratio in engine operation, inducing exacerbation of engine performance and HC emission. One effort to mitigate icing phenomenon is to attach anti-icing injection tip in the end of nozzle. Therefore, in this study, the effect of engine operation parameters as well as surrounding conditions on icing phenomenon was investigated in a bench test rig with commercially-used anti-icing injection tips. The test results show that considerable ice was deposited on the surface near the nozzle hole of the anti-icing tip in low rpm and low load operating conditions in ambient air condition. This is because acceleration of detachment of deposited ice from the tip surface was induced in high load, high rpm conditions, resulting in decrease in frost accumulation. The results of the bench testing also demonstrate that little or no ice was formed at surrounding temperature below a freezing point since the absolute amount of moisture contained in the intake air is too small in such a low temperature.

  • PDF

Simultaneous Determination of Amitraz, Bromopropylate, Coumaphos, Cymiazole and 2,4-Dimethylaniline in Korean Honey Samples by High-Performance Liquid Chromatography

  • Ryoo, Jae-Jeong;Kim, Se-Hoon;Jeong, Young-Han;Do, Hwan-Suk;Ryu, Jeong-Eun;Kwon, Hae-Young;Jeong, Ji-Yoon;Park, Hye-Jin;Lee, Soon-Ho;Hong, Moo-Ki;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.1043-1047
    • /
    • 2008
  • Simultaneous determination of amitraz, bromopropylate, coumaphos, cymiazole and 2,4-dimethylaniline in 200 honey samples purchased in Korea was performed by reversed-phase high-performance liquid chromatography with multiple UV detection. 2% Acetone in hexane was used for a liquid-liquid extraction and 20-40% water in acetonitrile solutions were used as mobile phases. The LOD for the analytes varied between 0.4 and 1.5 $\mu$g/L and the recoveries were yielded between 64 and 94%. Relative standard deviation of the repeatability of the method is less than 15%. Amitraz was not present in amount above 10 $\mu$ g/L and one for coumaphos and cymiazole and two for bromopropylate, and three for 2,4-dimethylanilne were detected in amount above 10 $\mu$ g/ L. Levels of the acaricide residues found were less than 50 $\mu$ g/L.

Selective Recovery of Platinum Group Metals by Solvent Extraction and Electrolysis in Non-aqueous Solution Based on Ionic Liquids (이온성액체 기반 비수계 용액에서 용매추출과 전해에 의한 백금족 금속의 분리회수)

  • Park, Gwang-won;Park, Jesik;Lee, Churl Kyoung
    • Resources Recycling
    • /
    • v.28 no.2
    • /
    • pp.46-53
    • /
    • 2019
  • In this study, the extraction and reduction behavior of platinum group metals in a non-aqueous solvent based on ionic liquids was investigated in order to confirm a new extraction technology of platinum group metals. Platinum was selectively extracted using an ionic liquid $[C_4mim]PF_6$ from a mixed solution of $PdCl_2$, $PtCl_4$ and $RhCl_3$ dissolved with concentration ratio of 10:1:0.5 M. After stripping of the metals by 1 M $HNO_3$ solution, the platinum was preferentially reduced by aqueous electrolysis on gold electrode at -0.8 V (vs. Pt-QRE). The residual palladium and rhodium were transferred to ionic liquid of $[C_4mim]Cl$. The metallic palladium and rhodium could be sequentially reduced on gold and STS304 as working electrodes by non-aqueous electrolysis, respectively.