• Title/Summary/Keyword: Liquid Liquid Extraction

Search Result 1,075, Processing Time 0.027 seconds

Ionic liquid coated magnetic core/shell CoFe2O4@SiO2 nanoparticles for the separation/analysis of trace gold in water sample

  • Zeng, Yanxia;Zhu, Xiashi;Xie, Jiliang;Chen, Li
    • Advances in nano research
    • /
    • v.10 no.3
    • /
    • pp.295-312
    • /
    • 2021
  • A new ionic liquid functionalized magnetic silica nanoparticle was synthesized and characterized and tested as an adsorbent. The adsorbent was used for magnetic solid phase extraction on ICP-MS method. Simultaneous determination of precious metal Au has been addressed. The method is simple and fast and has been applied to standard water and surface water analysis. A new method for separation/analysis of trace precious metal Au by Magnetron Solid Phase Extraction (MSPE) combined with ICP-MS. The element to be tested is rapidly adsorbed on CoFe2O4@SiO2@[BMIM]PF6 composite nano-adsorbent and eluted with thiourea. The method has a preconcentration factor of 9.5-fold. This method has been successfully applied to the determination of gold in actual water samples. Hydrophobic Ionic Liquids (ILs) 1-butyl-3-methylimidazole hexafluorophosphate ([BMIM]PF6) coated CoFe2O4@SiO2 nanoparticles with core-shell structure to prepare magnetic solid phase extraction agent (CoFe2O4@SiO2@ILs) and establish a new method of MSPE coupled with inductively coupled plasma mass spectrometry for separation/analysis of trace gold. The results showed that trace gold was adsorbed rapidly by CoFe2O4@SiO2@[BMIM]PF6 and eluanted by thiourea. Under the optimal conditions, preconcentration factor of the proposed method was 9.5-fold. The linear range, detection limit, correlation coefficient (R) and relative standard deviation (RSD) were found to be 0.01~1000.00 ng·mL-1, 0.001 ng·mL-1, 0.9990 and 3.4% (n = 11, c = 4.5 ng·mL-1). The CoFe2O4@SiO2 nanoparticles could be used repeatedly for 8 times. This proposed method has been successfully applied to the determination of trace gold in water samples.

Characteristics of trace analysis of potential diesel oxygenates using the factorial design in solid-phase microextraction with GC/FID (고체상미량분석법(SPME-GC/FID)에서 요인배치법을 이용한 디젤첨가제의 미량분석의 특성 평가)

  • Park, Jae-Sang;Chang, Soon-Woong
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.370-382
    • /
    • 2007
  • In this study, solid-phase microextraction (SPME) technique using GC/FID was studied as a possible alternative to liquid-liquid extraction for the analysis of EGBE, DGBE, DBM and TGME in water, and an optimization condition of trace analysis of EGBE, DGBE, DBM and TGME using the factorial design was described. Experiments used a fractional factorial design method followed by central composite design allowing optimization of a number of factors as well as statical analysis of results. The response surface analysis showed that the extraction efficiency can be described by a second-order polynomial equation in which the salts concentration, extraction temperature, extraction time and sonication time are the major influences. Using DOE, a new data-dependent method was developed that improved the quantity of confidently analyzed EGBE, DGBE, DBM and TGME in water samples.

Determination of Aloesin in Plasma by High-Performance Liquid Chromatography as Fluorescent 9-Anthroyl Derivative

  • Kim, Kyeong-Ho;Lee, Jin-Gyun;Park, Jeong-Hill;Shin, Young-Geun;Lee, Seung-Ki;Cho, Tae-Hyung
    • Archives of Pharmacal Research
    • /
    • v.21 no.6
    • /
    • pp.651-656
    • /
    • 1998
  • A sensitive high-performance liquid chromatographic (HPLC) method for the determination of aloesin in plasma was developed. After solid-phase extraction from plasma and derivatization of aloesin and compound AD-1, which was prepared from aloesin as a internal standard, with 9-anthroylnitrile in the presence of quinuclidine, the derivatives were separated on a Inertsil ODS-3 column using acetonitrile/methanol/water (3:1:6) as a mobile phase, and detected fluorimetrically at 460nm with excitation at 360nm. The detection limit of aloesin was 3.2ng/ml in plasma (S/N=3).

  • PDF

Microfluidic Components and Bio-reactors for Miniaturized Bio-chip Applications

  • Euisik Yoon;Yun, Kwang-Seok
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.86-92
    • /
    • 2004
  • In this paper miniaturized disposable micro/nanofluidic components applicable to bio chip, chemical analyzer and biomedical monitoring system, such as blood analysis, micro dosing system and cell experiment, etc are reported. This system includes various microfluidic components including a micropump, micromixer, DNA purification chip and single-cell assay chip. For low voltage and low power operation, a surface tension-driven micropump is presented, as well as a micromixer, which was implemented using MEMS technology, for efficient liquid mixing is also introduced. As bio-reactors, DNA purification and single-cell assay devices, for the extraction of pure DNA from liquid mixture or blood and for cellular engineering or high-throughput screening, respectively, are presented.

Salting-out Effects on the Partition of Proteins in Aqueous Two-phase Systems

  • KIM, CHAN-WHA;CHO KYUN RHA
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.5
    • /
    • pp.352-357
    • /
    • 1996
  • The partition of proteins in the salt-rich phase of polyethylene glycol (pEG)/salt aqueous two-phase systems is limited by the salting-out effects of salt. The logarithm of the concentration of proteins partitioned in the salt-rich phase decreases linearly with increases in the concentration of salt in the salt-rich phase (salting-out). Therefore, the partition of a given protein in the salt-rich phase of aqueous two-phase systems can be estimated from the salting-out constant. The slope of the solubility line (salting-out con-stant) for a given protein is determined by the type of salt in the two-phase systems.

  • PDF

Pattern Recognition for Typification of Whiskies and Brandies in the Volatile Components using Gas Chromatographic Data

  • Myoung, Sungmin;Oh, Chang-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.167-175
    • /
    • 2016
  • The volatile component analysis of 82 commercialized liquors(44 samples of single malt whisky, 20 samples of blended whisky and 18 samples of brandy) was carried out by gas chromatography after liquid-liquid extraction with dichloromethane. Pattern recognition techniques such as principle component analysis(PCA), cluster analysis(CA), linear discriminant analysis(LDA) and partial least square discriminant analysis(PLSDA) were applied for the discrimination of different liquor categories. Classification rules were validated by considering sensitivity and specificity of each class. Both techniques, LDA and PLSDA, gave 100% sensitivity and specificity for all of the categories. These results suggested that the common characteristics and identities as typification of whiskies and brandys was founded by using multivariate data analysis method.

Solubilities of Salen Derivatives and Their Cobalt Complex in Liquid and Supercritical CO2

  • Koh, Seung-Hyun;Jeon, Byung-Wan;Kim, Ha-Kwon;Park, Kwang-Heon;Kim, Hong-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.471-475
    • /
    • 2004
  • The solubility of N,N'-Bis(salicylidene) ethylenediamine (n-salen) and N,N'-bis(3,5-di-tert-butylsalicylidene) ethylenediamine (t-butyl-salen) was studied with in-situ UV-VIS spectrometer. n-Salen is 3-5 times more soluble than t-butyl-salen in liquid or supercritical $CO_2$. This behavior may be attributed to Lewis acid-base interaction between salen and $CO_2$. The chelation of salen with $Co^{++}$ ion in supercritical condition was confirmed to be fast enough above room temperature. However, the metal ion extraction capability of t-butyl salen is relatively poor because of its low solubility and ionic nature of complex.

Improved Calibration for the Analysis of Emerging Contaminants in Wastewater Using Ultra High Performance Liquid Chromatography and Time-of-Flight Mass Spectrometry

  • Pellinen, Jukka;Lepisto, Riikka-Juulia;Savolainen, Santeri
    • Mass Spectrometry Letters
    • /
    • v.9 no.3
    • /
    • pp.77-80
    • /
    • 2018
  • The focus of this paper is to present techniques to overcome certain difficulties in quantitative analysis with a time-of-flight mass spectrometer (TOF-MS). The method is based on conventional solid-phase extraction, followed by reversed-phase ultra high performance liquid chromatography of the extract, and mass spectrometric analysis. The target compounds included atenolol, atrazine, caffeine, carbamazepine, diclofenac, estrone, ibuprofen, naproxen, simazine, sucralose, sulfamethoxazole, and triclosan. The matrix effects caused by high concentrations of organic compounds in wastewater are especially significant in electrospray ionization mass spectroscopy. Internal-standard calibration with isotopically labeled standards corrects the results for many matrix effects, but some peculiarities were observed. The problems encountered in quantitation of carbamazepine and triclosan, due to nonlinear calibration were solved by changing the internal standard and using a narrower mass window. With simazine, the use of a quadratic calibration curve was the best solution.

Synthesis and Properties of Calix[4]crown-6 Functionalized Polymers

  • Kim Su-Han;Lee Chil-Won;Jeon Young-Min;Gong Myoung-Seon
    • Macromolecular Research
    • /
    • v.13 no.2
    • /
    • pp.141-146
    • /
    • 2005
  • Calix[4]crown-6-2,4-bis(4-aminobutyl ether), which has a crown-6 moiety at the 1,3-position and amino function at the 2,4-position, was prepared as an intermediate for the subsequent synthesis of calix[4]crown-6-containing polyamide and polyimide using adipoyl chloride and 1,2,4,5-benzenetetracarboxylic dianhydride. The chemical structures were characterized by IR, $^{1}H NMR$ spectroscopy and elemental analysis, and some of their physical properties, including their thermal behavior, were examined. The ion binding characteristics of the monomer and polymers for alkali metal and alkali earth metal ions were measured by liquid-liquid extraction from the aqueous phase into the organic phase. It has been observed that polyamide has a high binding ability towards various metal cations as compared to polyimide, which showed cesium ion selectivity.

Finite Element Analysis on Phase-Change Process of Pure Water (유한요소법을 이용한 순수 물의 상변화 과정에 대한 수치해석)

  • Hong Y. D.;Cha K. S.;Seo S. J.;Park C. G.
    • Journal of computational fluids engineering
    • /
    • v.7 no.4
    • /
    • pp.1-7
    • /
    • 2002
  • The phase-change transformation processes are relevant in many engineering applications. In particular, this phenomenon plays an important role in the extraction and fabrication operations in the metallurgical industry. The control of the heat transfer and fluid flow patterns is important to achieve casting quality and competitive production times. In the present study, a simple finite-element algorithm is developed for solid-liquid phase change problems. Natural convection in the liquid phase due to the temperature dependency of water density is considered by a numerical model. The predictions are compared with measurements by the particle image velocimetry(PIV). to show that the calculation results are in good agreement with the experiment results.