극저온 고압액체수소 공급용 인쇄기판 열교환기의 열설계에 관한 연구 (A Study on Thermal Design of Printed Circuit Heat Exchanger for Supply of Cryogenic High Pressure Liquid Hydrogen)

  • 손상호;최병일
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.347-355
    • /
    • 2021
  • This paper is a study on the thermal design of printed circuit heat exchanger (PCHE) to supply cryogenic high pressure liquid hydrogen stored from hydrogen liquefaction process by using computational fluid dynamics (CFD). This PCHE should be thermally designed to raise the temperature of cryogenic liquid hydrogen to a desired temperature and also to be anti-icing to avoid any local freezing in hot channel. This research presents the effect of inlet velocity and inlet temperature of hydrogen, and the effect of flow configurations of co/counter-flow on thermal design of PCHE heat exchanger based on various CFD simulation analysis.

소형 수소액화기 설계 및 운전에 관한 연구 (Design and Operation of a Small-Scale Hydrogen Liquefier)

  • 백종훈;강상우;강형묵;나다니엘 갈소;김서영;오인환
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.105-113
    • /
    • 2015
  • In order to accelerate hydrogen society in current big renewable energy trend, it is very important that hydrogen can be transported and stored as a fuel in efficient and economical fashion. In this perspective, liquid hydrogen can be considered as one of the most prospective storage methods that can bring early arrival of the hydrogen society by its high gravimetric energy density. In this study, a small-scale hydrogen liquefier has been designed and developed to demonstrate direct hydrogen liquefaction technology. Gifford-McMahon (GM) cryocooler was employed to cool warm hydrogen gas to normal boiling point of hydrogen at 20K. Various cryogenic insulation technologies such as double walled vacuum vessels and multi-layer insulation were used to minimize heat leak from ambient. A liquid nitrogen assisted precooler, two ortho-para hydrogen catalytic converters, and highly efficient heat pipe were adapted to achieve the target liquefaction rate of 1L/hr. The liquefier has successfully demonstrated more than 1L/hr of hydrogen liquefaction. The system also has demonstrated its versatile usage as a very efficient 150L liquid hydrogen storage tank.

Liquid Crystal Droplet Patterns to Monitor Catalase Activity at Femtomolar Levels

  • Yoon, Stephanie;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2704-2710
    • /
    • 2014
  • Catalase (CAT) decomposes hydrogen peroxide that is toxic to the body. In this study, simple and sensitive detector has been developed for observing catalase activity using liquid crystal droplet system. Microscale LC droplet patterns are formed by spreading aldehyde-doped nematic liquid crystal on pre-treated glass slides. When hydrogen peroxide is added, aldehyde is oxidized and amphiphiles are formed. Dodecanoates cause the pattern to transit from bright to dark as they self-assemble to form a carboxyalte monolayer at the interface. When a drop of pre-incubated CAT and hydrogen peroxide mixture is placed onto the pattern, bright fan-shape is observed. This planar optical appearance indicates that catalase has decomposed hydrogen peroxide. Compared to the detectors that have been previously developed, this system is more sensitive with detection limit of 1fM. This research suggests further studies to be on LC droplet patterning to develop highly sensitive and methodologically simple sensors for various chemicals.

액체수소 사고피해 완화기술에 대한 연구 (A Study on Mitigating Accidents for Liquid Hydrogen)

  • 조영도;김진준
    • 한국가스학회지
    • /
    • 제16권6호
    • /
    • pp.29-33
    • /
    • 2012
  • 이 연구에서는 최근의 액체수소안전관련 연구현황을 간략히 살펴보고자 한다. 액체수소 저장용기가 파손되어 액체수소가 누출될 수 있다. 누출된 액체수소는 풀을 형성하고 증발하여 수소증기 운을 형성한 뒤 증기운 폭발이 일어날 수 있다. 액체수소를 저장하고 있는 용기가 외부로부터 유입되는 열에 의하여 증발하는 가스를 처리하지 못할 경우에는 BLEVE가 발생할 수 있다. 압축된 수소가스가 있는 시설에서는 수소누출에 의한 제트화제가 발생하고 지연점화에 의하여 개방공간에서 플래시 화재 및 폭발이 발생할 수 있다. 이러한 여러 가지 사건에 대하여 최근의 기술개발과 향후연구개발 방향에 대하여 간략히 살펴보았다.

극저온 액체수소 기화기용 인쇄기판 열교환기의 동결 조건에 관한 실험적 연구 (Experimental Investigation on the Freezing Condition of Printed Circuit Heat Exchanger for Cryogenic Liquid Hydrogen Vaporizer)

  • 김우경;김보겸;손상호;이공훈;김정철
    • 한국수소및신에너지학회논문집
    • /
    • 제35권2호
    • /
    • pp.240-248
    • /
    • 2024
  • The purpose of this study is to investigate the freezing phenomena in printed circuit heat exchanger (PCHE) for cryogenic liquid hydrogen vaporizer. Local freezing phenomena in hot channels should be avoided in designing PCHE for cryogenic liquid hydrogen vaporizer. Hence, the flow and thermal characteristics of PCHE is experimentally investigated to figure out the conditions under when freezing occurs. To conduct lab-scale PCHE experiment, liquid nitrogen is used as a working fluid in cold channels instead of using liquid hydrogen. Glycol water is used as a working fluid in hot channels. Based on the experimental data, ratio between mass flow rates of cold channels and that of hot channels is proposed as contour map to avoid the freezing phenomena in PCHE.

Organic co-solvents mediated variation in anion-water hydrogen bonding in [Bmim][BF4] ionic liquid through FTIR spectroscopy

  • Manna, Arpan;Lim, Manho
    • Rapid Communication in Photoscience
    • /
    • 제4권3호
    • /
    • pp.67-69
    • /
    • 2015
  • FTIR spectroscopy has been employed to investigate the variation of anion-water hydrogen bonding in 1-butyl 3-methyl imidazolium tetrafluoroborate ([Bmim][$BF_4$]) ionic liquid caused by addition of organic co-solvents with various polarities. The variation was estimated by probing band shape and intensity of the OH stretching vibration of trace water present in ionic liquid at $3400-3800cm^{-1}$. The presence of polar aprotic co-solvent in ionic liquid dramatically reduces the absorptivity of the OH stretch band, indicating that the co-solvent changes the nature of anion-water hydrogen bond drastically, which might be responsible for the reduction of the viscosity of ionic liquid in the presence of the co-solvent.

극저온냉동기 예냉 수소액화기의 기초설계 (Basic design of hydrogen liquefier precooled by cryogenic refirgerator)

  • 김승현;장호명;강병하
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.389-400
    • /
    • 1997
  • A thermodynamic cycle analysis is performed for refrigerator-precooled Linde-Hampson hydrogen liquefiers, including catalysts for the ortho-to-para(o-p) conversion. three different configurations of the liquefying system, depending upon the method of the o-p conversion, are selected for the analysis. After some simple and justifiable models are introduced, a general analysis program to predict the liquid yield and the figure of merit(FOM) is developed with incorporating the commercial computer code for the hydrogen properties. The discussion is focused on the effect of the two primary design parameters-the precooling temperature and the high pressrure of hydrogen. When the precooling temperature is in the range between 45 and 60 K, the optimal high pressure for the maximal liquid yield is found to be in the range between 100 to 140 bar, regardless of the o-p conversion. However, the FOM can be maximized at slightly smaller values of high pressures. It is remarkable to observe that the lower precooling temperatures are favorable since both the liquid yield and the FOM can be obtained without compressing hygrogen to extremely high pressures.

  • PDF

Characteristic analysis and condenser design of gas helium circulation system for zero-boil-off storage tank

  • Jangdon Kim;Youngjun Choi;Keuntae Lee;Jiho Park;Dongmin Kim;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권4호
    • /
    • pp.65-69
    • /
    • 2023
  • Hydrogen is an eco-friendly energy source and is being actively researched in various fields around the world, including mobility and aerospace. In order to effectively utilize hydrogen energy, it should be used in a liquid state with high energy storage density, but when hydrogen is stored in a liquid state, BOG (boil-off gas) is generated due to the temperature difference with the atmosphere. This should be re-condensed when considering storage efficiency and economy. In particular, large-capacity liquid hydrogen storage tank is required a gaseous helium circulation cooling system that cools by circulating cryogenic refrigerant due to the increase in heat intrusion from external air as the heat transfer area increases and the wide distribution of the gas layer inside the tank. In order to effectively apply the system, thermo-hydraulic analysis through process analysis is required. In this study, the condenser design and system characteristics of a gaseous helium circulation cooling system for BOG recondensation of a liquefied hydrogen storage tank were compared.

포화상태에 놓인 C-Type 액체수소 탱크의 슬로싱이 열 유속과 BOG에 미치는 변화의 수치적 분석 (Numerical Study of Heat Flux and BOG in C-Type Liquefied Hydrogen Tank under Sloshing Excitation at the Saturated State)

  • 이진호;황세윤;이성제;이장현
    • 한국전산구조공학회논문집
    • /
    • 제35권5호
    • /
    • pp.299-308
    • /
    • 2022
  • 본 논문은 슬로싱 상태에 놓인 포화 상태 액체수소탱크에서 열 유속 및 BOG(Boil-off gas)의 경향을 다루고 있다. 특히, 액체-기체간의 침투 및 혼합에 의한 열 교환에 관심을 두었다. 먼저, VOF(Volume of fluid)와 Eulerian 기반의 다상 유동모델로 모형 슬로싱 실험을 모사하여 압력을 예측하고 계측된 값과 비교하였다. 자유 수면 및 충격 압력 실험 결과와 해석 결과를 비교하였으며, 유체의 속도 예측에서 정확할 수 있음을 간접적으로 증명하였다. 그리고 2차원의 Type-C 원통형 수소탱크를 대상으로 다상열유동해석을 수행하였다. 이때 포화상태에 놓인 액체 및 기체수소를 가정하고, 해석을 통해 각 상간의 혼합에 의한 열 교환의 수준을 확인하고자 하였다. 단, 상간의 열 교환만을 관심으로 두고 있었으므로 질량전달 및 기화모델은 해석에서 제외하였다. 최종적으로 상의 혼합으로 인해 액체수소로 유입되는 열 유속의 기여도에 대하여 정리하였다. 또한 액체수소로 유입되는 열 유속과 집중 질량 기반의 간이식을 통해 BOG 발생량 및 경향을 예측하고 분석하였다.

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF