Capillary Flow in Different Cells of Thuja orientalis, Gmelina arborea, Phellodendron amurense

  • Chun, Su Kyoung
    • 한국가구학회지
    • /
    • 제28권3호
    • /
    • pp.248-258
    • /
    • 2017
  • A study was carried out to observe the 1% aqueous safranine solution flow speed in longitudinal and radial directions of softwood Thuja orientalis L., diffuse-porous wood Gmelina arborea Roxb., and ring-porous wood Phellodendron amurense Rupr., Longitudinal flow was considered from bottom to top while the radial flow was considered from bark to pith directions. In radial direction, ray cells and in longitudinal direction tracheids, vessel and wood fiber were considered for the measurement of liquid penetration speed at less than 12% moisture contents(MC). The variation of penetration speed for different species was observed and the reasons behind for this variation were explored. The highest radial penetration depth was found in ray parenchyma of T. orientalis but the lowest one was found in ray parenchyma of P. amurense. The average liquid penetration depth in longitudinal trachied of T. orientalis was found the highest among all the other cells. The penetration depth in fiber of G. arborea was found the lowest among the other longitudinal cells. It was found that cell dimension and also meniscus angle of safranine solution with cell walls were the prime factors for the variation of liquid flow speed in wood. Vessel was found to facilitate prime role in longitudinal penetration for hardwood species. The penetration depth in vessel of G. arborea was found highest among all vessels. Anatomical features like ray parenchyma cell length and diameter, end-wall pits number were found also responsible fluid flow differences. Initially liquid penetration speed was high and the nit gradually decreased in an uneven rate. Liquid flow was captured via video and the penetration depths in those cells were measured. It was found that even in presence of abundant rays in hardwood species, penetration depth of liquid in radial direction of softwood species was found high. Herein the ray length, lumen area, end wall pit diameter determined the radial permeability. On the other hand, vessel and fiber structure affected the longitudinal flow of liquids. Following a go-stop-go cycle, the penetration speed of a liquid decreased over time.

고속유동장내 액체분열현상 (Phenomena of Liquid Jet Breakup in High Speed Gas Stream)

  • 박용국;석지권;이충원
    • 한국분무공학회지
    • /
    • 제1권2호
    • /
    • pp.66-73
    • /
    • 1996
  • The present study investigates experimentally the characteristics of liquid jet, which is, the spray flow in the normal direction of the air stream under the flow conditions of air velocity $110\sim125m/s$. The present study adopts with the flow visualization technique using a short duration light bulb and the image processing analyse with CCD camera. Two types of injector were used: one is a flat plate type, and the other is backward facing step type, which height are 5, 8, 10mm. Dispersion of liquid jet can be represented by gray level of CCD camera. In the upstream of liquid jet, the backward facing step shows better liquid jet penetration. However, in the downstream. mean droplet size for backward facing step injector is smaller than that for flat plate injector

  • PDF

경사면상의 층류 세류유동 특성 (Flow Characteristics of a Laminar Rivulet Down an Inclined Surface)

  • 김병주
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1035-1042
    • /
    • 2005
  • In the present study, the principle of minimum energy is employed to configure the shape of rivulet flowing down an inclined surface. The profile of laminar rivulet is determined by numerical integration. The maximum center thickness, which corresponds to the minimum thickness of falling film, is found to exist regardless of liquid flow rate and is compared with the analytical and experimental data. At small liquid flow rate the center thickness of rivulet and its width increase almost linearly with flow rate. Once the center thickness of rivulet becomes very close to its maximum value, its growth rate retards abruptly. However the width of rivulet increases proportionally to the liquid flow rate and most part of its free surface is as flat as that of stable film. The growth rate of rivulet thickness with respect to liquid flow rate becomes larger at bigger contact angle. The width of rivulet increases rapidly with its flow rate especially at small contact angle, As the liquid-vapor interfacial shear stress increases, the center thickness of rivulet decreases with its flow rate, which is remarkable at small contact angle. However the effect of interfacial shear stress on the width of rivulet is almost negligible.

식기세척기 내부 유동 분포 분석을 위한 유동가시화 기법 개발 (Development of Flow Visualization Technique for Analysis of Flow Distribution inside Dishwasher)

  • 김아란;함정윤;조진호;조위삼;고한서
    • 한국가시화정보학회지
    • /
    • 제11권2호
    • /
    • pp.12-17
    • /
    • 2013
  • A flow visualization technique was developed to analyze flow distribution inside a dishwasher in this study. Then, a new design plan was proposed to improve the efficiency of the dishwasher by the analyzed results and it was confirmed experimentally by the developed technique. Gas flow fields inside a drying duct of a tub for a drying process was investigated by a developed PIV (Particle Image Velocimetry) and a CFD (Computational Fluid Dynamics) method. Also, the flow visualization technique was developed for the liquid flow field of a rotor-arm system to propose the improved design idea. Also, interactions between liquid and gas were observed around the rotor-arm system. The two-phase flow was modified to the liquid flow field because laser sheets are refracted when pass through the two-phase flow. Thus, the flow visualization techniques was developed in this study to measure the instantaneous flow velocities in the liquid quantitatively.

저고상율 소재의 유동 및 응고현상을 고려한 레올로지 성형공정해석 (Process Analysis for Rheology Forming Considering Flow and Solidification Phenomena in Lower Solid Fraction)

  • 정영진;조호상;강충길
    • 한국정밀공학회지
    • /
    • 제18권9호
    • /
    • pp.156-164
    • /
    • 2001
  • Two-dimensional solidification analysis during rheology forming process of semi-solid aluminum alloy has been studied. Two-phase fluid flow model to investigate the velocity field and temperature distribution is proposed. The proposed mathematical model is applied to the die shape of the two types. To calculate the velocity and temperature fields during rheology forming process, the earth governing equation correspondent to the liquid and solid region are adapted. Therefore, each numerical models considering the solid and liquid region existing within the semi-solid material have been developed to predict the deflect of rheology forming gnarls. The Arbitrary Boundary Maker And Cell (ABMAC) method is employed to solve the two-phase flow model of the Navier-Stokes equation. Theoretical model on the basis of the two-phase flow model is the mixture rule of solid and liquid phases. This approach is based on the liquid and solid viscosity. The liquid viscosity is pure liquid state value, however solid viscosity is considered as a function of the shear rate, solid fraction and power law curves.

  • PDF

Application of DFB Diode Laser Sensor to Reacting Flow (II) - Liquid-Gas 2-Phase Reacting Flow -

  • Park, Gyung-Min;Masashi Katsuki;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.139-145
    • /
    • 2003
  • Diode laser sensor is conducted to measure the gas temperature in the liquid-gas 2-phase counter flow flame. C$\_$10/H/ sub 22/ and city gas were used as liquid fuel and gas fuel, respectively. Two vibrational overtones of H$_2$O were selected and measurements were carried out in the spray flame region stabilized the above gaseous premixed flame. The path-averaged temperature measurement using diode laser absorption method succeeded in the liquid fuel combustion environment regardless of droplets of wide range diameter. The path-averaged temperature measured in the post flame of liquid-gas 2-phase counter flow flame showed qualitative reliable results. The successful demonstration of time series temperature measurement in the liquid-gas 2-phase counter flow flame gave us motivation of trying to establish the effective control system in practical combustion system. These results demonstrated the ability of real-time feedback from combustor inside using the non-intrusive measurement as well as the possibility of application to practical combustion system. Failure case due to influence of spray flame was also discussed.

흙의 비배수전단강도가 0이 되는 함수비인 흐름한계의 제안 (A Proposal of Flow Limit for Soils at Zero Undrained Shear Strength)

  • 박성식;농쩐쩐
    • 한국지반공학회논문집
    • /
    • 제29권11호
    • /
    • pp.73-84
    • /
    • 2013
  • 사면 내 토사가 붕괴되거나 토석류가 발생하는 경우 파괴면에 작용하는 전단강도는 0에 가깝게 되면서 토사가 비점성 액체와 같이 유동한다. 점성토는 함수비 증가에 따라 그 연경도가 달라지며 액체상태로 바뀌는 액성한계에서 도 약간의 전단강도를 가진다. 본 연구에서는 점성토의 전단강도가 0이 되어 흐름을 유발하는 함수비를 찾고자 하였 다. 카올리나이트, 벤토나이트, 그리고 카올리나이트(50%)+벤토나이트(50%)와 같은 세 종류의 점토에 혼합수로 증류 수, 해수, 또는 미생물용액을 혼합하여 액성한계 상태로 만든 다음 함수비를 단계적으로 증가시키면서 토베인 시험기 를 이용하여 비배수전단강도를 측정하였다. 액성한계와 소성한계에서 비배수전단강도의 범위는 각각 3.6-9.2kPa와 24-45kPa 정도이었다. 한편 측정 결과로부터 비배수전단강도가 급격하게 변화하는 값에 해당하는 함수비를 흐름함수 비(Flow Water content)로 정의하였으며, 비배수전단강도가 0이 될 때의 함수비를 흐름한계(Flow Limit)로 정의하였다. 그리고 흐름한계와 액성한계의 상관관계를 살펴보기 위하여 흐름한계와 액성한계의 차이를 점성지수(Cohesive Index) 로 정의하였다. 또한 흐름한계와 소성한계의 차이를 새로운 소성지수(New Plasticity Index)로 정의하였으며, 흐름한계를 이용하여 새로운 액성지수(New Liquidity Index)도 정의하였다. 흐름한계(Flow Limit)는 액성한계보다 1.5-2배 정도 높은 값을 보였으며, 새로운 소성지수는 기존 소성지수보다 2-5.5배 정도 높았다.

Empirical Correlations for Breakup Length of Liquid Jet in Uniform Cross Flow-A Review

  • No, Soo-Young
    • 한국분무공학회지
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2013
  • The empirical correlations for the prediction of breakup length of liquid jet in uniform cross flow are reviewed and classified in this study. The breakup length of liquid jets in cross flow was normally discussed in terms of the distances from the nozzle exit to the column breakup location in the x and y directions, called as column fracture distance and column fracture height, respectively. The empirical correlations for the prediction of column fracture distance can be classified as constant form, momentum flux ratio form, Weber number form and other parameter form, respectively. In addition, the empirical correlations for the prediction of column fracture height can be grouped as momentum flux ratio form, Weber number form and other parameter form, respectively. It can be summarized that the breakup length of liquid jet in a cross flow is a basically function of the liquid to air momentum flux ratio. However, Weber number, liquid-to-air viscosity ratio and density ratio, Reynolds number or Ohnesorge number were incorporated in the empirical correlations depending on the investigators. It is clear that there exist the remarkable discrepancies of predicted values by the existing correlations even though many correlations have the same functional form. The possible reasons for discrepancies can be summarized as the different experimental conditions including jet operating condition and nozzle geometry, measurement and image processing techniques introduced in the experiment, difficulties in defining the breakup location etc. The evaluation of the existing empirical correlations for the prediction of breakup length of liquid jet in a uniform cross flow is required.

액체로켓 엔진에서의 극저온 산화제의 유동 특성 (Flow Characteristics of Cryogenic Oxidizer in Liquid Propellant Rocket Engine)

  • 조남경;정용갑;문일윤;한영민;이수용;정상권
    • 한국추진공학회지
    • /
    • 제6권4호
    • /
    • pp.15-23
    • /
    • 2002
  • 액체 로켓 엔진 메니폴드 및 인젝터 부는 단열 사양을 적용할 경우 시스템이 복잡해지고 무게가 증가함으로 인해 일반적으로 단열 사양이 적용되지 않는다. 단열사양을 적용하지 않을 경우에 일어날 수 있는 문제는 액체산소의 온도 상승과 메니폴드 내부벽 및 인젝터에서 기체가 발생할 수 있다는 점이다. 본 연구에서는 극저온 액체산소를 산화제로 사용하는 KSR-III 액체로켓 엔진의 산화제 메니폴드 및 인젝터에서 측정된 압력 강하 값을 이용하여 발생된 기체 분율을 계산하였다. 액체산소 메니폴드 기체 분율 계산은 이상유동의 분리유동 모델을 활용하였고. 인젝터에서의 기체분율은 오리피스 모델을 활용하여 예측하였다. 이와 함께 메니폴드 열해석을 수행하여 비등현상에 대한 유동형태를 파악하였다. 또한 액체로켓 엔진내에서의 기체 발생이 로켓 엔진의 성능 및 연소 안정성에 미치는 영향에 대하여 간략히 고찰하였다.

Transition of Rivulet Flow from Linear to Droplet Stream

  • Kim, Ho-Young;Kim, Jin-Ho;Kang, Byung-Ha;Lee, Seung-Chul;Lee, Jae-Heon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권3호
    • /
    • pp.147-152
    • /
    • 2002
  • When a liquid is supplied through a nozzle onto a relatively non-wetting inclined solid surface, a narrow rivulet forms. There exist several regimes of rivulet flow depending on various flow conditions. In this paper, the fundamental mechanism behind the transition of a linear rivulet to a droplet flow is investigated. The experiments show that the droplet flow emerges due to the necking of a liquid thread near the nozzle. Based on the observation, it is argued that when the retraction velocity of a liquid thread exceeds its axial velocity, the bifurcation of the liquid thread occurs, and this argument is experimentally verified.