• 제목/요약/키워드: Liquid Charge

검색결과 241건 처리시간 0.024초

비전도성 액체의 전기수력학적 미립화를 위한 전하 주입 특성에 관한 실험적 연구 (An Experimental Study on Charge Injection to Non-Conducting Liquid for Electrohydrodynamic Atomization)

  • 이기준;박종승;이상용
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1376-1383
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with the increase of liquid flow rate and input voltage. When the distance between the needle tip and the ground electrode becomes closer, the total, leakage and spray currents increase, while the onset voltage for the dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the liquid flow rate due to the higher charge density and the enhanced aerodynamic effect.

액정을 함유하는 유기 광도점체의 전하 수송착체에 의한 Charge-Carrier수송 특성과 형광거동 (Charge-Carrier Transport Properties and Fluorescence Behaviors Depending on Charge Transport Complex of Organic Photoconductor Containing Liquid Crystal)

  • 이봉;정선영;문두경
    • 폴리머
    • /
    • 제25권5호
    • /
    • pp.719-727
    • /
    • 2001
  • 유기광도전체에 있어서의 액정은 종래의 분자 배향성을 가지지 않는 비정성 고체계와는 달리 분자 배향성을 가지기 때문에 분자 사이의 질서도가 높아지게 되고, charge-carrier의 hopping을 방해하는 hopping site의 공간적인 틈이 작아져 고 이동도의 특성을 가질수 있다. 본 연구에서는 유기광도전체의 전하 수송층에 액정5CT를 혼합하여, charge-carrier수송특성에 있어서의 액정5CT의 영향을 관찰하였다. 액정5CT를 함유한 유기광도전체는 액정의 혼합비가 증가함에 따가 초기전위는 증가하였으며, 암감쇄는 감소하는 경향을 나타내었다. 감도는 5CT를 TNF와 OXD 각자에 대하여 40 wt%로 혼합한 시료의 경우에 가장 우수하게 나타났다. 형광거동을 관찰한 결과, 이는 전하수송재료와 액정5CT의 전하 수송착체에 의한 것으로, 액정5CT를 TNF와 OXD 각각에 대하여 40 wt%로 혼합한 시료의 경우가 다른 시료에 비해 전하 수송착체가 가장 잘 형성되어, 성공을 잘 수송하기 때문으로 나타났다.

  • PDF

비전도성 액체의 전하주입형 2-유체 노즐에 대한 분무 특성 (Spray Characteristics of Charge Injected 2-fluid Nozzle for Non-conducting Liquid)

  • 박민규;최영주;김상수
    • 한국분무공학회지
    • /
    • 제11권3호
    • /
    • pp.155-160
    • /
    • 2006
  • Spray characteristics of charge injected 2-fluid nozzle for non-conducting liquid have been studied. Spray current, specific charge and SMD of diesel have been measured. Spray current and specific charge are proportional to applied voltage. Air flow did not effect on spray current and specific charge. SMD decreases as air flow rate increases and decreases as applied voltage increases additionally. Spray angle increases as applied voltage increases. Fine droplets are obtained by charge injected 2-fluid nozzle without charge loss.

  • PDF

비전도성 액체의 전기수력학적 분무에 관한 실험적 연구 (An Experimental Study on Electrohydrodynamic Atomization of Non-Conducting Liquid)

  • 이기준;박종승;이상용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1322-1327
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with increase of liquid flow rate and input voltage. When the distance between the needle and the ground electrode becomes closer, total, leakage and spray current increase, but the onset voltage for dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the flow rate because the higher charge density is achieved with the larger liquid velocity in addition to the enhanced aerodynamic effect.

  • PDF

Electrohydrodynamic Analysis of Dielectric Guide Flow Due to Surface Charge Density Effects in Breakdown Region

  • Lee, Ho-Young;Kang, In Man;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.647-652
    • /
    • 2015
  • A fully coupled finite element analysis (FEA) technique was developed for analyzing the discharge phenomena and dielectric liquid flow while considering surface charge density effects in dielectric flow guidance. In addition, the simulated speed of surface charge propagation was compared and verified with the experimental results shown in the literature. Recently, electrohydrodynamics (EHD) techniques have been widely applied to enhance the cooling performance of electromagnetic systems by utilizing gaseous or liquid media. The main advantage of EHD techniques is the non-contact and low-noise nature of smart control using an electric field. In some cases, flow can be achieved using only a main electric field source. The driving sources in EHD flow are ionization in the breakdown region and ionic dissociation in the sub-breakdown region. Dielectric guidance can be used to enhance the speed of discharge propagation and fluidic flow along the direction of the electric field. To analyze this EHD phenomenon, in this study, the fully coupled FEA was composed of Poisson's equation for an electric field, charge continuity equations in the form of the Nernst-Planck equation for ions, and the Navier-Stokes equation for an incompressible fluidic flow. To develop a generalized numerical technique for various EHD phenomena that considers fluidic flow effects including dielectric flow guidance, we examined the surface charge accumulation on a dielectric surface and ionization, dissociation, and recombination effects.

Influence of the Inclination Angle and Liquid Charge Ratio on the Condensation in Closed Two-Phase Thermosyphons with Axial Internal Low-Fins

  • Cho, Dong-Hyun;Han, Kyu-il
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.422-428
    • /
    • 2003
  • This study concerns the performance of the heat transfer of the thermosyphons having 60, 70, 80. 90 axial internal low-fins in which boiling and condensation occurr. Water, HCFC-141b and CFC-11 have been used as the working fluids. The operating temperature, the liquid charge ratio and the inclination angle of thermosyphons have been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from experimental results. The experimental results have been assessed and compared with existing theories. As a result of the experimental investigation, it was found that the maximum heat flow rate in the thermosyphons is dependent upon the liquid charge ratio and inclination angle. A relatively high rate of heat transfer has been achieved by the thermosyphon with axial internal low-fins. The inclination of a thermosyphon has a notable influence on the condensation. In addition, the overall heat transfer coefficients and the characteristics at the operating temperature are obtained for the practical applications.

Simulation Study of an e-Beam Addressed Liquid Crystal Display for Projection

  • Zhou, Fushan;Yang, Deng-Ke;Molitor, R.J.
    • Journal of Information Display
    • /
    • 제3권4호
    • /
    • pp.8-12
    • /
    • 2002
  • We have carried out a simulation study on an e-beam addressed liquid crystal projection display in which the liquid crystal is switched by the electric field of the charge, produced by an electron beam, on the surface of the display. We calculated the electric field produced by the surface charge, the liquid crystal director configuration and the profile of the transmitted light. We studied the factors affecting the resolution of the display and the effect of pretilt angle on the performance of the display. The e-beam addressed liquid crystal projection display potentially has the advantages of high resolution and high brightness.

A Study on the Improvement of Heat Transfer Performance in Low Temperature Closed Thermosyphon

  • Han, Kyu-Il;Yee, Seok-Su;Park, Sung-Hyun;Lee, Suk-Ho;Cho, Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제16권9호
    • /
    • pp.1102-1111
    • /
    • 2002
  • The study focuses on the heat transfer performance of two-phase closed thermosyphons with plain copper tube and tubes having 50, 60, 70, 80, 90 internal grooves. Three different working fluids(distilled water, methanol, ethanol) are used with various volumetric liquid fill charge ratio from 10 to 40%. Additional experimental parameters such as operating temperature and inclination angle of zero to 90 degrees are used for the comparison of heat transfer performance of the thermosyphon. Condensation and boiling heat transfer coefficients, heat flux are obtained using experimental data for each case of specific parameter. The experimental results are assessed and compared with existing correlations. The results show that working fluids, liquid fill charge ratio, number of grooves and inclination angle are very important factors for the operation of thermosyphons. The relatively high rate of heat transfer is achieved when the thermosyphon with internal grooves is used compared to that with plain tube. The optimum liquid fill charge ratio for the best heat transfer performance lies between 25% and 30%. The range of the optimum inclination angle for this study is 20$^{\circ}$~30$^{\circ}$ from the horizontal position.

A Comparison of the Heat Transfer Performance of Thermosyphon Using a Straight Groove and a Helical Groove

  • Han Kyuil;Cho Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권12호
    • /
    • pp.2296-2302
    • /
    • 2005
  • This study is focused on the comparison of heat transfer performance of two thermosyphons having 60 straight and helical internal grooves. Distilled water has been used as working fluid. Liquid fill charge ratio defined by the ratio of working fluid volume to total internal volume of thermosyphon, the inclination angle and operating temperature were used as experimental parameters. The heat flux and heat transfer coefficient are estimated from experimental results. The conclusions of this study may be summarized as follows; Liquid fill charge ratio, inclination angle and geometric shape of grooves were very important factors for the operation of thermosyphon. The optimum liquid fill charge ratio for the best heat flux were $30\%$. The heat transfer performance of helically grooved tube was higher than that of straight grooved tube in low inclination angle (less than $30^{\circ}$), but the results were opposite in high inclination angle (more than $30^{\circ}$). As far as optimum inclination angle concerns, range of $25^{\circ}\~30^{\circ}$ for a helically grooved tube and about $40^{\circ}$ for a straight grooved tube are suggested angles for the best results.

Modeling an e-Beam Addressed Liquid Crystal Projection Display

  • Yang, Deng-Ke;Zhou, Fushan;Molitor, R.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.930-932
    • /
    • 2002
  • We have carried a theoretical study on e-beam addressed liquid crystal projection display in which the liquid crystal is switched by the electric field of the charge, produced by an electron beam, on the surface of the display. We calculated the electric field produced by the surface charge, the liquid crystal director configuration and the profile of the transmitted light. We studied the factors affecting the resolution of the display. We also studied the effect of pretilt angle on the performance of the display. The e-beam addressed liquid crystal projection display potentially has the advantages of high resolution and high brightness.

  • PDF