• Title/Summary/Keyword: Link-K

Search Result 4,609, Processing Time 0.036 seconds

Link Quality based Efficient Code Propagation in Wireless Sensor Networks (센서네트워크에서 Link Quality를 고려한 효율적인 코드전파 기법)

  • Cho, Sung-Kywoo;Cha, Ho-Jung
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.439-441
    • /
    • 2005
  • 본 논문에서는 센서네트워크에서 Link Quality를 이용하여 코드와 같은 대용량의 데이터를 적을 에너지로 다르게 전파하는 LQNP 기법을 제안한다. 센서 네트워크에서 코드의 전파 방법에 대한 기존 연구들은 Link Quality를 고려하지 않고 코드를 전파하는 정책을 쓰고 있다. 패킷 손실이 많은 센서네트워크에서 이 방법은 적합하지 않기 때문에 본 논문에서는 패킷 손실이 많은 상황에서도 효율적인 코드 전파를 수행할 수 있도록 Link Quality를 이용하는 방법을 살펴본다.

  • PDF

An Adaptive Prefiltering Method for Reduction of DC-link ripple in Cascaded NPC/H-bridge System (Cascaded NPC/H-bridge 시스템의 DC-link 리플 저감을 위한 적응 선필터링 기법)

  • Lee, Hoon;Kang, Jin-Wook;Hyun, Seung-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.445-446
    • /
    • 2017
  • In this paper, adaptive prefiltering method is proposed for reduction of dc-link ripple in cascaded NPC/H-bridge system. Under non-linear load such as electric machine or harmonically distorted conditions, dc-link capacitor voltage with harmonics is inevitable result. In terms of reducing dc-link ripple, prefiltering method combined low pass filter with multiple second order generalized integrator is proposed. Proposed prefiltering method effectively reduces harmonics of dc-link ripple and improves characteristic of THD, simulated by using MATLAB R2014a and PSIM 9.1.4.

  • PDF

Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage (전원전압과 DC-link 전압 추정에 의한 3상 컨버터 센서리스 제어)

  • Chu Hung-Seok;Cheon Chang-Gun;Ahn Jin-Woo;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.227-230
    • /
    • 2001
  • A new control method of three phase converter without measuring input Phase-voltage and DC-link voltage is Proposed. Input Phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In additon, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

A study on link system of the programmable controller (Programmable Controller의 Link System에 관한 연구)

  • 안재봉;지동근;최호현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.175-177
    • /
    • 1986
  • 본 연구에서는 금성계전에서 이미 개발된 고기능 PC인 STARCON-M에 적용 할 수 있는 Link 시스템을 구성하여 다음과 같은 결론을 얻을 수 있었다. 1) 병렬 Link 시스템을 구성하여 최대 입출력 점수가 280점인 PC를 최대 744점 프로그램 용량이 최대 12K Word까지 확장하여 사용 할 수 있었다. 2) 직렬 Link 시스템을 구성하여 완벽한 분산제어 시스템을 구성할 수 있었으며 Master와 Local의 비율을 1:7까지 할 수 있고 동축 cable에 의해 500m 까지 연결하므로서 PC의 효율성을 증가시켰다. 3) Computer Link 에 의해 PC와 Computer간에 Data를 교신하므로서 관리 감시 제어 시스템을 구성할 수 있었다.

  • PDF

Multi-Channel High Speed Data Link Design for Small SAR Satellite Image Data Transmission

  • Kwag, Young K.
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1436-1439
    • /
    • 2002
  • In this paper, based on the data link model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath.

  • PDF

Basic Characteristic of 5-level Inverter with Different Divided DC Link Voltage

  • Matsuse, Kouki;Matsumoto, Takafumi;Kodera, Yuji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.179-183
    • /
    • 2013
  • This paper report on experimental results of 5-level inverter by DC divided link voltage. We have alreday reported that DC divided link valtage comes to be able to reduse harmonic of out line voltage. So we tested whether DC divided link voltage can reduce harmonics in experimental setup. This paper shows simulation results and experimental results. And we confirmed that DC divided link voltage can also apply in experimental setup.

Modeling and Analysis of High Speed Serial Links (SerDes) for Hybrid Memory Cube Systems (하이브리드 메모리 큐브 (HMC) 시스템의 고속 직렬 링크 (SerDes)를 위한 모델링 및 성능 분석)

  • Jeon, Dong-Ik;Chung, Ki-Seok
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.4
    • /
    • pp.193-204
    • /
    • 2017
  • Various 3D-stacked DRAMs have been proposed to overcome the memory wall problem. Hybrid Memory Cube (HMC) is a true 3D-stacked DRAM with stacked DRAM layers on top of a logic layer. The logic die is mainly used to implement a memory controller for HMC, and it is connected through a high speed serial link called SerDes with a host that is either a processor or another HMC. In HMC, the serial link is crucial for both performance and power consumption. Therefore, it is important that the link is configured properly so that the required performance should be satisfied while the power consumption is minimized. In this paper, we propose a HMC system model included the high speed serial link to estimate performance accurately. Since the link modeling strictly follows the link flow control mechanism defined in the HMC spec, the actual HMC performance can be estimated accurately with respect to each link configuration. Various simulations are conducted in order to deduce the correlation between the HMC performance and the link configuration with regard to memory utilization. It is confirmed that there is a strong correlation between the achievable maximum performance of HMC and the link configuration in terms of both bandwidth and latency. Therefore, it is possible to find the best link configuration when the required HMC performance is known in advance, and finding the best configuration will lead to significant power saving while the performance requirement is satisfied.

On a Bayes Criterion for the Goodness-of-Link Test for Binary Response Regression Models : Probit Link versus Logit Link

  • Kim, Hea-Jung
    • Journal of the Korean Statistical Society
    • /
    • v.26 no.2
    • /
    • pp.261-276
    • /
    • 1997
  • In the context of binary response regression, the problem of constructing Bayesian goodness-of-link test for testing logit link versus probit link is considered. Based upon the well known facts that cdf of logistic variate .approx. cdf of $t_{8}$/.634 and, as .nu. .to. .infty., cdf of $t_{\nu}$ approximates to that of N(0,1), Bayes factor is derived as a test criterion. A synthesis of the Gibbs sampling and a marginal likelihood estimation scheme is also proposed to compute the Bayes factor. Performance of the test is investigated via Monte Carlo study. The new test is also illustrated with an empirical data example.e.

  • PDF

Cage Link and the Effect of Cross-Link Breakdown (Cross-Link Breakdown 효과와 Cage Link)

  • Oh, Teresa;Kim, Kyung-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.517-520
    • /
    • 2004
  • Organosilicate films are promising porous low-dielectric materials, which can replace the silicon dioxide films. It was researched that organosilicate films have two different chemical shifts according to the increase of the flow rate ratio. There are the red shift due to the electron deficient substitution group, and the blue shift of the electron rich substitution group. Among these chemical shifts, the blue shift from $1000 cm^{-1}$ to $1250 cm^{-1}$ was related with the formation of pores. The methyl radicals of the electron-rich substitution group terminate easily the Si-O-Si cross-link, and the Si-O-C cage-link near $1057 cm^{-1}$ is originated from the cross-link breakdown due to much methyl radicals.

  • PDF

Bypass-Based Star Aggregation Using Link Attributes for Improving the Information Accuracy

  • Kwon, Sora;Jeon, Changho
    • Journal of Communications and Networks
    • /
    • v.17 no.4
    • /
    • pp.428-439
    • /
    • 2015
  • In this study, we present an approach for reducing the information inaccuracy of existing star aggregation based on bypass links when there are multi-constraint QoS parameters in asymmetric networks. In our approach, bypass links with low similarity are selected. Links that are not chosen as bypass links are included in each group depending on the star's link characteristics. Moreover, each link group is aggregated differently according to the similarity of the links that make up the group. The selection of a bypass link by using link similarity reduces the existing time complexity of O($N^3$) to O(N) by virtue of the simplification of the selection process. In addition, the adaptive integration according to the characteristics of the links in each group is designed to reduce the information inaccuracy caused by static aggregation. Simulation results show that the proposed method maintains low information distortion; specifically, it is 3.8 times lower than that of the existing method, even when the number of nodes in a network increases.