• Title/Summary/Keyword: Lines

Search Result 13,742, Processing Time 0.035 seconds

Exposure limits of Magnetic fields of High Voltage Transmission lines for Evaluation of Environmental Impact (고압선로 환경영향평가의 자기장 노출범위설정에 관한 연구)

  • Jeon, In-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.5
    • /
    • pp.243-250
    • /
    • 2004
  • Recently, concerns about health risks exposed to electromagnetic fields have been brought in the safety of electric power lines. A number of governmental and international organizations have advised to avoid the magnetic field exposure to the schools and residential areas. Some epidemiologic studies showed that electromagnetic fields should not exceed the exposure limits of 2-3mG to the people living near high-voltage transmission lines. In this study, the principles, ranges and survey methods of the assessment for powerfrequency electromagnetic fields were reviewed from the relevant research papers and documents. The ranges of electromagnetic fields were determined from 50m to 100m and have been defined according to the properties of each electric power lines and a new methodology was suggested in this study. It would be necessary to develop and improve specific assessment methods for various high-voltage transmission lines projects.

Analysis and Comparision of Measured and Calculated Value on Magnetic Fields Strength under Transmission Lines (초고압 송전선로의 자계크기 해석과 실측 비교)

  • Cho, Sung-Bae;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.7
    • /
    • pp.832-838
    • /
    • 1999
  • Recently, there are growing concerns about power frequency electric and magnetic fields coming out from the high voltage transmission lines, because of the wide spread perception of their probable harmful effect on human body. In connection with this trend, this paper describes the electric and magnetic fields measurement result around 154 kV and 345 kV transmission lines, a comparison of measured EMF to calculated one and the correlations between transmission lines currents and measured magnetic fields. Daily maximum and minimum magnetic field quantities under the selected 154 kV and 345 kV transmission lines had been measured for 1 year of 1997 and the average value of magnetic field exposure under the lines were calculated and presented based on the measured data.

  • PDF

Application of Supervisory System in Extra High Voltage Cable (초고압 케이블의 송전 감시 시스템 소개 및 기술동향)

  • Kwon, Byung-Il;Nam, Jeong-Se;Kang, Deok-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1791-1793
    • /
    • 1997
  • Since Korea was initiated a industrialization, many transmission lines have been installed to meet the increasing demand for the electric power. In large city, underground transmission lines were widely installed because of the environmental issue. But there have been appeared many failures on the lines, such as the external scar of cable, a fire in the culvert, overheating of cable, and so on. There have been many studies to monitor them and improve the reliability of the power supply. As a method monitoring the lines, a DTS(Distributed Temperature Sensor) system is developed and applied. This system monitors the lines and predicts the failures, using a optical fiber sensor. This paper describes this DTS system and its application for the underground transmission lines.

  • PDF

Isotomic and Isogonal Conjugates Tangent Lines of Lines at Vertices of Triangle

  • Seo, Min Young;Ahn, Young Joon
    • Journal of Integrative Natural Science
    • /
    • v.10 no.1
    • /
    • pp.27-32
    • /
    • 2017
  • In this paper we consider the two tangent lines of isogonal and isotomic conjugates of the line at both vertices of a given triangle. We find the necessary and sufficient condition for the two tangent lines of isogonal or isotomic conjugates of the line at both vertices and the median line to be concurrent. We also prove that every line whose isogonal conjugate tangent lines at both vertices are concurrent with the median line intersects at a unique point. Moreover, we show that the three intersection points correspond to the vertices of triangle are collinear.

"Dust, Ice, and Gas In Time" (DIGIT) Herschel observations of GSS30-IRS1

  • Je, Hyerin;Lee, Jeong-Eun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.50.1-50.1
    • /
    • 2013
  • As part of the DIGIT key program, we observed GSS30-IRS1, a Class I object located in Ophiuchus (d=125 pc), with Herschel-PACS. More than 70 lines were detected: CO lines of $J=14{\rightarrow}13$ to $41{\rightarrow}40$, several $H_2O$ lines of Eu=100 to 1500 K, 16 OH lines, and two atomic [OI] lines at 63 and 145 ${\mu}m$. All lines, except for [OI], were detected only at the central spaxel of $9.4^{\prime\prime}{\times}9.4^{\prime\prime}$ while the [OI] emission is extended along the NE-SW direction. One interesting feature in GSS30-IRS1 is that the continuum is extended beyond PSF, unlike the line emission. For detail analysis, we apply the non-LTE LVG model, RADEX as well as simple rotational diagrams to the detected line fluxes. We will discuss about the physical conditions around GSS30-IRS1, learned by the line flux analysis.

  • PDF

A Study on the Generation of Ship Hull Lines Using NURBS Method (NURBS 기법을 이용한 선체선도 형성에 관한 연구)

  • 이동기
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.1
    • /
    • pp.95-101
    • /
    • 2000
  • In general, free form design depends on B-spline which is used for the generating hull lines in most of shipyards. But, nowadays, the NURBS method is applied to free form modeling method, which is able to more flexible transformation than B-Spline, and then became industrial standard in the various field. Therefore, this method has been considerably applied in new application fields which are required free form modelling. In this paper, the program called 2DSURF with 5 modules and developed for the generation of hull lines is described. It is examined whether the program can be applied to body lines, sheer lines, and half breadth lines.

  • PDF

NEAR-INFRARED SPECTROSCOPY OF YOUNG GALACTIC SUPERNOVA REMNANTS

  • KOO, BON-CHUL;LEE, YONG-HYUN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.145-148
    • /
    • 2015
  • Young Galactic supernova remnants (SNRs) are where we can observe closely supernova (SN) ejecta and their interaction with the circumstellar/interstellar medium. They also provide an opportunity to explore the explosion and the final stage of the evolution of massive stars. Near-infrared (NIR) emission lines in SNRs mostly originate from shocked dense material. In shocked SN ejecta, forbidden lines from heavy ions are prominent, while in shocked circumstellar/interstellar medium, [Fe II] and $H_2$ lines are prominent. [Fe II] lines are strong in both media, and therefore [Fe II] line images provide a good starting point for the NIR study of SNRs. There are about twenty SNRs detected in [Fe II] lines, some of which have been studied in NIR spectroscopy. We will review the NIR [Fe II] observations of SNRs and introduce our recent NIR spectroscopic study of the young core-collapse SNR Cas A where we detected strong [P II] lines.

Estimation and Extraction of Unstable Frequency Lines of Acoustic Signal Using Neural Network

  • Ha, Seok-Wun;Hwang, Soo-Bok;Kim, Jae-Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2E
    • /
    • pp.39-44
    • /
    • 1999
  • In passive sonar, underwater moving objects are identified by the acoustic sounds they transmit. The spectrum of these sounds show features about the mechanism of the sound source, these features are discrete frequencies on the spectrum and frequency lines on the spectrogram. Variability in the underwater environment produce discontinuous broken or unstable fluctuating frequency lines. In this paper, we propose an efficient algorithm that estimate continuities of the discontinuous frequency lines and extract presence of the unstable frequency lines using neural networks and represent the proposed algorithm shows good performance in estimation and extraction the unstable frequency lines through the experiments.

  • PDF

Impedance measurement and analysis of overhead medium voltage power lines for broad band power line communication (BPLC) ($1{\sim}30MHz$ 광대역 전력선 통신을 위한 고압 배전선의 임피던스 특성 측정 및 해석)

  • Park, Young-Jin;Lee, Jae-Jo;Kim, Kwan-Ho;Lee, Won-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2345-2347
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power lines is reported for power line communication (PLC) over an MV power line network. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the transmission line theory, reflection behavior and impedance of power lines are investigated. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power lines is between $200{\Omega}$ and $300{\Omega}$ and converges to a half of their characteristic impedance.

  • PDF

Development of Optimal Sensor for Diagnostic System in Overhead Distribution Power Lines (가공 배전선로 진단시스템을 위한 최적 센서 개발)

  • Lee, Kyeong-Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.10
    • /
    • pp.670-675
    • /
    • 2015
  • Degradation diagnosis of cable is one of major issues for operation and maintenance in overhead distribution power lines. The diagnostic system for overhead power lines is composed of three parts in functional aspect - a travelling unit, a sensing unit and a communication unit. Among them, sensor detects the defects such as corrosion and disconnecting of power lines. Performance of sensor is very important, and besides, the size and structure of sensor is restricted for installation to small and lightweight diagnostic system. This paper suggests an optimal eddy current sensor best suit for small and lightweight diagnostic system in consideration of detecting performance, size and ease of installation and so on. Proposed sensor has been designed by Drum core structure and can be applied to the all domestic overhead power lines regardless of the cross-sectional areas. Also, it is showed that results of mock environmental test are satisfied.