• Title/Summary/Keyword: Liner change

Search Result 81, Processing Time 0.028 seconds

Bio-barrier Formation by Biomass Injection into Soil (미생물 토양 주입을 통한 Bio-barrier 형성)

  • Kim, Geon-Ha;Song, Youngwoo;Gu, Dongyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.927-938
    • /
    • 2000
  • When microorganism is injected into porous medium such as soils along with appropriate substrate and nutrients, biomass retained in the soil pore. Soil pore size and shape are varied from the initial condition as a result of biofilm formation, which make hydraulic conductivity reduced. In this research, hydraulic conductivity reduction was measured after microorganism are inoculated and cultured with synthetic substrates and nutrients. Biomass-soil mixture was evaluated its applicability to the field condition as an alternative liner material in landfill by measuring hydraulic conductivity change after repetitive freeze-thaw cycles. Resistance of biofilm to chemical solution and degree of biodegradation were measured through column test.

  • PDF

A new insight into design of acoustic liner arrays arrangement in the presence of a grazing flow

  • Hadi Dastourani ;Iman Bahman-Jahromi
    • Advances in Computational Design
    • /
    • v.8 no.4
    • /
    • pp.273-293
    • /
    • 2023
  • This study evaluated the acoustic performance of two configurations of serial HR arrays and lined HR arrays in the presence of grazing flow using a 3D numerical simulation. The dual, triple, and quad HR arrays were compared to the conventional HR array. The simulation results showed that the number of resonant frequencies increased with the number of serial HR arrays. The CTL did not significantly change with the number of serial HR arrays. The acoustic performance of the two, three, and four-lined HR arrays was compared to the conventional HR array. The results showed that the resonant frequency and TLmax increased with the number of lined HR arrays. The CTL also increased with the number of lined HR arrays. The effect of the grazing flow Mach number (Ma) was investigated on the four-lined HR array configuration and compared to the conventional HR configuration. TLmax and CTL decreased for both configurations with increasing Ma. The four-lined HR array configuration had significantly better acoustic performance than the conventional HR configuration. The TLmax and CTL increased by more than 300% when the configuration was changed from the conventional HR to the four-lined HR array at Ma = 0.The increment percentage decreased with increasing Ma.

A Study on Unsaturated Permeable Properties of the Soil-Bentonite Mixtures (Soil-Bentonite 혼합토의 불포화 투수특성 연구)

  • Kim Man-il
    • The Journal of Engineering Geology
    • /
    • v.15 no.2 s.42
    • /
    • pp.123-132
    • /
    • 2005
  • This study presents the results of a laboratory investigation performed to study physical properties of soil-bentonite mixtures through the vertical permeation test and dielectric measurement test using Frequency Domain Reflectometry system for the liner of waste landfill. For the laboratory experiments, geotechnical testing was conducted on pre-mixed soil-bentonite which is consisted of standard sand, weathered granite soil and bentonite for estimating physical parameters such as a volumetric water content, void ratio and dielectric constant. In experiment results, initial soil-bentonite mixing rate has an effect of change of volumetric water content. Also change of volumetric water content of a soil-bentonite mixture is clearly detected to measure a response of dielectric constant. In order to estimate an unsaturated permeable property of soil-bentonite mixtures, equations between volumetric water content and dielectric constant were derived from this study.

Temperature Variations of Air Pocket in Type-3 Composite Vessel during Ambient Hydraulic Cycling Test (상온 수압반복시험 시 Type 3 복합재용기 내 공기층의 온도변화)

  • Cho, Sung-min;Kim, Kwang Seok;Kim, Chang Jong;Lyu, Geun-jun;Lee, Yeon-jae;Jo, Yun Seong;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.120-125
    • /
    • 2015
  • This research aims to increase the reliability and reproducibility of the ambient cycling test by properly making corrections to the test procedure. The vessel (106 L) is initially filled with 70 L of water and horizontally placed on a balance. The pressure range inside the vessel varies from 2.5 to 25.9 MPa at the frequency of 6 cycles per minute. After reviewing the results, there was a temperature difference of approximately $10^{\circ}C$ between the air pocket and the water, and the upper part of the liner faced a repeated temperature change of $40^{\circ}C$. It is possible for the aluminum liner of the composite vessel to be damaged by such a sharp change in temperature. Additionally, as a result, no pass having anything to do with the purpose of the test would occur. Therefore, it is suggested that the air pocket be completely removed.

Numerical Analysis of Combustion Characteristics during Combustion Mode Change of a Low NOx Utility Gas Turbine (발전용 저 NOx 가스터빈의 연소모드 변환시기의 연소특성 전산해석)

  • Jeong, Jai-Mo;Chung, Jae-Hwa;Park, Jung-Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • Three-dimensional numerical investigations are carried out to understand the combustion characteristics inside a DLN(dry low NOx) utility gas turbine combustor during the combustion mode change period by applying transient fuel flow rates in fuel supply system as numerical boundary conditions. The numerical solution domain comprises the complex combustor liner including cooling air holes, three types of fuel nozzles, a swirl vane, and a venturi. Detailed three-dimensional flow and temperature fields before and after combustion mode changeover have been analyzed. The results may be useful for further studies on the unfavorable phenomena, such as flashback or thermal damage of combustor parts when the combustion mode changes.

Environment Change of Marine Transportation and Inter-related Development of Shipping and Shipbuilding Industries in Korea

  • Lee, Jin-Tae;Lim, Chin-Soo;Kim, Tae-Il;Koh, Chang-Doo
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.2
    • /
    • pp.34-45
    • /
    • 2007
  • Environment of marine transportation market is changing rapidly. Due to globalization of world economy, marine transportation of cargos, especially trade using container boxes, is increasing dramatically. Fierce competition in the global market of container transportation forces the shipping industry to seek the economy of scale to reduce transportation cost, and drives the merge and alliance of liner shipping companies. Mega-sized container ships, having capacity over 10,000 TEU, were introduced, and appeared recently, in order to reduce the unit transportation cost. Korean shipping and shipbuilding companies are competitive, and have considerable market share in the global market. Even though both industries are inter-connected through ships and have many common interests in order to enlarge the global market share, inter-relation between two industries is surprisingly insignificant. In this paper current issues in the process of environmental change of marine cargo transportation are reviewed, and inter-relation of shipping and shipbuilding industries is discussed. Suggestions for inter-related development of Korean shipping and shipbuilding industries are given, and means for mutually beneficial collaboration are suggested.

Performance Characteristics of Vehicle Air Conditioning System Using Internal Heat Exchanger with Inner Fin (휜 타입 내부열교환기 적용에 따른 차량용 냉방시스템 성능 특성)

  • Kim, Sung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.69-73
    • /
    • 2013
  • Internal heat exchanger (IHX) apparatus using the temperature difference between high and low pressure lines in vehicle air conditioning system is a good method to enhance the cooling performance. In this study, we designed various double-pipe internal heat exchangers which have inner fins between the internal pipe and external pipe. We also measured the performance characteristic (pressure drop, cooling capacity, compressor work and coefficient of performance (COP)) of the modified internal heat exchangers that had the change of the fin height and the inside shape of the internal pipe. This experimental results indicated that the liner and serration type internal heat exchanger was the best cooling performance. In addition, the air conditioning system with the liner and serration type internal heat exchanger showed the improved performances of about 6.4% and 9.2%, respectively, for the cooling capacity and COP.

A Study on the Characteristics of Mine Liner According to the Contents of CSA Using Industrial Byproducts (산업부산물을 활용한 CSA 첨가량에 따른 광산 차수재 특성에 관한 연구)

  • Kang, Suk-Pyo;Lee, Yeong-Hun;Kang, Hye-Ju;Cho, Sung-Hyun;Cho, Yong-Kwang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.74-81
    • /
    • 2019
  • In this study, to characterize the application of CSA and dihydrate gypsum Utilizing industrial byproducts, we investigated the characteristics of CSA and dihydrate gypsum to investigate the characteristics of Mine Liner according to the addition amount. As a result of compressive strength, length change and absorption rate of mining lime wastewater according to CSA addition amount, up to 30% of CSA showed a positive effect on shrinkage and absorption reduction effect as well as strength at initial age. However, due to excessive use of CSA 50%, it was reduced by 15% compared to OPC due to increase of absorption rate and decrease of cement amount due to over expansion rather than shrinkage compensation and void filling.

Sensitivity analysis for freight rate change in liner shipping industry - Comparison between slot chartering model and non-collaborating model - (정기선 해운사의 해상운송 요율 변화에 대한 민감도 분석 - 단독 운송과 제휴 운송 비교 -)

  • Chung, Ki-Ho
    • Management & Information Systems Review
    • /
    • v.34 no.4
    • /
    • pp.1-13
    • /
    • 2015
  • This paper presents a mathematical formulation for container slot chartering model through strategic alliance between liner shipping companies. This paper develops a solution procedure to apply the model to real world problems and its applicability is demonstrated by a numerical example. The model presented in this paper has some important features which have never been considered in the previous researches. The model is linear model and pursuits profit maximization. And also it considers slot chartering capacity selection. This paper attempts to perform sensitivity analysis and compares slot chartering model with basic non-collaborating model in which there is no alliance and collaboration. As a result of sensitivity analysis, some interesting findings are obtained; Even though freight rate is more and more decreasing, the profit by slot chartering model is always higher than the basic model but the profit gaps become smaller. But The ratio of the profit gap to the profit of basic model is more increasing.

  • PDF

Test Results of Composite Cylinder Surface Temperature change between Pool Fire and Single Impinging Jet Flame Exposure Condition (전체 화염 및 단일 화염 노출 조건에서 복합재료 용기 표면 온도 변화 비교)

  • Lee, Jae-Hun;Hwang, Jun-Ho;Kim, Young-Seop;Kim, Hyo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.648-651
    • /
    • 2009
  • 탄소섬유강화플라스틱(CFRP:Carbon Fiber Reinforced Plastic)용기의 외부에 화재가 발생할 경우 함침된 수지(Resin)가 탄화되면서 자체 강도가 약화되고 충전된 가스가 외부 온도 상승에 따라 압력 상승이 발생하여 용기의 폭발로 이어지는 사고가 발생할 개연성이 높다. 화염 노출조건에서 복합재료 용기의 폭발을 방지하기 위하여 용기용 밸브에 내장된 온도감응식 압력안전장치(TPRD:Thermally activated Pressure Relief Device) 작동 성능을 검증하기 위한 방법으로 화염실험(Bonfire test)를 실시하고 있으나, 개방 공간에서 실시되는 이 실험은 표면 온도 변화가 매우 크게 발생하여 실험에 대한 재현성(Reproducibility)에 의문이 제기되고 있다. 따라서, 표면 온도를 일정하게 유지하기 위한 실험 방법의 개선이 필요하다. 본 연구에서는 경유+heptane을 이용한 전체 화염에 노출되는 경우와, 천연가스를 이용한 단일화염에 노출되는 경우의 실험 결과 비교를 통하여 화염 노출 표면 온도를 일정하게 유지하기 위한 가열 방법의 타당성을 검토하였다. 또한, 복합재료 라이너(Liner)의 온도 변화 비교를 통하여 집중화염 노출 조건에서 열전달 특성을 알아보았다.

  • PDF