• Title/Summary/Keyword: Linear measuring system

Search Result 298, Processing Time 0.027 seconds

System Construction for Monitoring characteristic of LIM (유도형 리니어 모터의 특성 모니터링 시스템 구현)

  • Jang, Seok-Myeong;Lee, Sung-Lae;Lee, Sung-Ho;Park, Young-Tae;Park, Chan-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.52-54
    • /
    • 1999
  • This paper presents the results of monitoring for measuring characteristics of Linear induction motor. The results is divided into three parts, that is part for electrical quantity caculation, thrust caculation and speed decting part. Also, for the purpose of measuring the characteristics of LIM, LabVIEW software is used.

  • PDF

Load modeling and dynamic characteristic analysis of Permanent Magnet Linear Synchronous Motor (부하형태에 따른 LSM의 부하 모델링 및 기동특성 해석)

  • Lee, Dong-Yeup;Han, Kwang-Kyu;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.89-91
    • /
    • 2006
  • This paper presents dynamic characteristic of Permanment Magnet Linear Synchronous Motor(PMLSM). In order to analyze dynamic characteristics, simulink of Matlab is used. The measuring system of dynamic characteristics is manufactured and experiment results are compared with simulation results.

  • PDF

Neural network based position estimation of mobile robot in slippery environment (Slip이 발생할 때 신경회로망을 이용한 이동로보트의 위치추정에 관한 연구)

  • 최동엽;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.133-138
    • /
    • 1993
  • This paper presents neural network based position estimation method in slippery environment as an approach to solve one of problems which are engaged in dead reckoning method. Position estimator is composed of slip detector and linear velocity estimator. Both of them are based on the fact that dynamic characteristic of mobile robot in slippery environment is different from the case without slip. To find out the dynamic relation among driving torque, angular acceleration of driving wheel and linear acceleration of mobile robot, accelerometer is used for measuring acceleration of mobile robot and neural network is used for dynamic system identifier in slippery environment.

  • PDF

A Study on the Temperature Measuring System of an Oral Cavity (구강 내부 온도 계측을 위한 센서 시스템 연구)

  • Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1165-1169
    • /
    • 2007
  • In this study, a novel sensor system for measuring the temperature inside an oral cavity is proposed. With this aim, a small size of thermistor was used for resolving the cavity's temperature with the resolution of $0.1^{\circ}C$. To evaluate effectiveness of our sensor system, the temperature and its output voltage characteristic, and the specifications of response are investigated. It turned out to be that our sensor system has a linear property in terms of temperature variations for a healthy subject's body temperature range and has a good response time within 3 seconds. Also, in order to investigate the medical application, our sensor system is sought to measure the real temperature variations of a subject's oral cavity and ark shell especially for 'before' and 'after' exercise mode.

Development of The Screw Lead Measurement System (나사 리드 측정시스템 개발)

  • Choi, Jong-Guen;Choi, Hyeon-Cheol;Kim, Hyung-Sun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.7-13
    • /
    • 2007
  • This study proposes a new screw measurement system that is capable of measuring the pitch or lead of a screw, which is one of the most important parameters representing the screw quality. There are various conventional methods for screw measurement including some mechanical and optical ones, but they can not be applied to measure the lead except the profiles or sizes. The newly suggested method is able to measure the pitch or lead directly. This is executed by scanning the thread with a digital probe while the target screw rotates. The devised measurement system is a integrated computer system which is composed of a stepping motor, a digital linear gauge and a chuck device for holding the measured screw. In order to operate the system effectively and conveniently, a computer program having graphical user interface facility is developed. Some experiments were done to prove the effectiveness of the system.

A Study on the Protection and Measuring Algorithm of IED in Load Condition (부하상태를 고려한 IED 보호 및 계측 알고리즘에 관한 연구)

  • Lee, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.527-532
    • /
    • 2012
  • Recently, in power system, even though the needs of protective IED(Intelligent Electronic Device) is highly increased, there are some problems in the field when use the IED. When the IED is in the fluctuated overload condition, because of the existing algorithm calculate the trip time only with the measured current of just previous measuring stage, the calculated trip time is not a proper value for the overload protection at this kind of condition, and when the load current fluctuate between overload and normal condition, because of the instantaneous reset characteristic of existing algorithm the IED dose not trip. And the non linear loads using power electronic elements seem to be increased. These non linear loads require a counterplan about various harmonics incoming to electric power systems. So we will give solutions about these problems.

ON PREDCTION OF CONCENTRATION OF LIQUID FOOD BY ACOUSTIC NON-LINEAR PARAMETER B/A

  • Nishizu, Takahisa;Ikeda, Yoshio
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.344-352
    • /
    • 1993
  • The purpose of this study is to investigate the possibility of the non-destructive quality evaluation for food by the acoustic non-linear parameter B/A which is a measure of the non-linearity of the state equation of the medium in terms of pressure and density. The B/A of water, corn oil O/W(oil in water) emulsion and milk were measured by using a sound velocity measuring system. The B/A value of water was measured for ascertaining reliability of our experimental system. Corn oil W/W emulsion was prepared as a model of milk . It was proved that the B/A value of O/W emulsion was related to the oil concentration by a law of mixture. We applied this result to milk and obtained satisfactory results for predicting the milk fat concentration.

  • PDF

Switched Reluctance Contact-Free Linear Actuator Using Attractive Magnetic Forces (자기 흡인력에 의한 비접촉식 SR 형 선형 구동기)

  • 이상헌;정광석;백윤수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.47-55
    • /
    • 2003
  • In the development of positioning device for precision manufacturing and measuring, the friction from mechanical contact causes serious decrease of performance. In this study, we studied about variable reluctance type contact-free linear actuator to overcome drawbacks from friction. In the view of electromagnetics, we analyzed and derived theoretical magnetic force equation and designed structure for generating suspension and propulsion force simultaneously. In the view of dynamics, we derived equation of motion and identified the stability of the system. Finally, we verified the feasibility of the proposed system.

Development of a One-step Two-site Enzyme Immunoassay for Measuring Human Alpha-fetoprotein by Eliminating Hook-effect

  • Kim, Se-Ho
    • BMB Reports
    • /
    • v.34 no.1
    • /
    • pp.47-50
    • /
    • 2001
  • A one-step, two-site enzyme immunoassay was developed for measuring human alpha-fetoprotein (AFP) in serum and amniotic fluid using monoclonal antibodies (McAb) by eliminating the high-dose hook effect. Three McAbs that recognize different epitopes were selected among 16 different clones on the basis of epitope mapping, two for immobilization and one for horseradish peroxidase conjugation. This one-step immunoassay system is more convenient and rapid compared to a conventional two-step sandwich immunoassay system. It did not exhibit the hook effect to around 2.7 mg/ml of AFP, which is probably one of the highest concentrations of AFP in the serum. The dose-response curve of the system was linear to 500 mg/ml of AFP and the system could differentiate as low as 1 mg/ml of AFP The intra- and inter-assay variations were in an acceptable range; 95~104% and 97~105% respectively Its correlation with other commercial systems was around 95%.

  • PDF

Four Degree-of-Freedom Geometric Error Measurement System with Common-Path Compensation for Laser Beam Drift

  • Qibo, Feng;Bin, Zhang;Cuifang, Kuang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.26-31
    • /
    • 2008
  • A precision four-degree-of-freedom measurement system has been developed for simultaneous measurement of four motion errors of a linear stage, which include straightness and angular errors, The system employs a retro-reflector to detect the straightness errors and a plane mirror to detect the angular errors. A common-path compensation method for laser beam drift is put forward, and the experimental results show that the influences of beam drift on four motion errors can be reduced simultaneously. In comparison with the API 5D laser measuring system, the accuracy for straightness measurement is about ${\pm}1.5{\mu}m$ within the measuring range of ${\pm}650{\mu}m$, and the accuracy for pitch and yaw measurements is about ${\pm}1.5$ arc-seconds within the range of ${\pm}600$ arc-seconds.