• Title/Summary/Keyword: Linear measuring system

Search Result 297, Processing Time 0.035 seconds

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

A Comparison of coincidence between the Light field & the Radiation field using film and BIS (필름과 BIS 영상장치를 이용한 광/방사선조사야 일치성 비교평가)

  • Bang, Dong-Wan;Seok, Jin-Yong;Jeong, Yun-Ju;Choi, Byeong-Don;Park, Jin-Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.33-41
    • /
    • 2004
  • Purpose : Film has been the primary tool in coincidence testing between the light field and the radiation field, which constitutes the quality assurance list of a linear accelerator. But there is a great chance of errors being different among the observer when using film. Thus this study set out to use the BIS(Beam Image System) in addition to film in comparing and evaluating coincidence results between the two fields and in searching for the improvement measures. Materials & Methods : Photon beam of 6 and 15MV was exposed to film and the BIS using a linear accelerator. The light and radiation fields were each $50{\times}50,\;100{\times}100,\;and\;200{\times}200mm^2$. The gantry angle was $0^{\circ}$ when using film and $0^{\circ}\;and\;270^{\circ}$ when using the BIS. The devices adopted to test coincidence between the two fields were a ruler and film scanner when using film. With the BIS, the width of the scanned light and radiation fields was measured for errors with setting the X and Y axis. Results : The visual measurements of the observer with film resulted that the radiation field was bigger than the light field and that their maximum error was 1.9mm. The results were the same with the measurements using the film scanner except for the average error, which was less than 1.9mm. On the contrary, the measurements using the BIS showed that the light field was bigger than the radiation field at the gantry angle of $0^{\circ}\;and\;270^{\circ}$. The maximum error was 0.96mm, and the error range was $<{\pm}2mm$ both in the X and Y axis. The average error of ${\Delta}X$, Y was the smallest in the order of the visual film measurements, film scanner measurements, and BIS measurements Conclusion . This requires a careful measurement for accurate quality assurance since errors are much different according to each observer that tests coincidence between visual fields with film. And an observer needs to use another image device or develop a measuring device of his own if it seems necessary for accurate measurements.

  • PDF

Effect of syllable complexity on the visual span of Korean Hangul reading and its relation to reading abilities (한글 글자 유형이 시각 폭과 읽기 능력에 미치는 영향)

  • Choi, Youngon;Kim, Tae Hoon
    • Korean Journal of Cognitive Science
    • /
    • v.27 no.2
    • /
    • pp.325-353
    • /
    • 2016
  • The visual span refers to the number of letters that can be accurately recognized without moving one's eyes. The size of the visual span is affected by sensory factors such as perimetric complexity, crowding, and mislocation of letters. Korean Hangul utilizes rather unique alphabetic-syllabary writing system, quite different from English and Chinese writing systems. Due to this combinatorial nature of the script, the visual span for Hangul characters can also be affected by the letter type (e.g., CV vs CVCC). The present study examined the effect of syllable complexity on the visual span for Hangul by comparing letter recognition accuracy across four letter type conditions (C only, CV, CVC, and CVCC). We also aimed to determine the meaningful letter type(s) that is associated with differences in reading abilities in Korean. Using a trigram presentation method, we found that overall recognition accuracy declined as syllable complexity increased. However, the visual span for CVC type was greater than that for CV type, suggesting that the effect is not necessarily linear, and that there might be other factors affecting the visual span for these types of letters. C and CV type showed fairly strong positive correlations with reading comprehension, suggesting that these might be the meaningful units for measuring visual span in relating to reading abilities.

Elution Behavior of Pd(II) - Isonitrosoethylacetoacetate Imine Chelates by Reversed Phase High Performance liquid Chromatography (역상 액체 크로마토그래피에 의한 Pd(II) - Isonitrosoethylacetoacetate Imine 유도체 킬레이트들의 용리 거동)

  • Kim, In-Whan;Shin, Han-Chul;Lee, Man-Ho;Yoon, Tai-Kun;Kang, Chang-Hee;Lee, Won
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.389-399
    • /
    • 1992
  • Liquid Chromatographic behavior of Pd(II) in Isonitrosoethylacetoacetate lmine, $Pd(IEAA-NR)_2$ (R=H, $CH_3$, $C_2H_5$, $n-C_3H_7$, $C_6H_5-CH_2$, $n-C_4H_9$) chelates were investigated by reversed-phase HPLC on Micropak MCH-5 column using methanol/water as mobile phase. The optimum conditions for the separation of $Pd(IEAA-NR)_2$ chelates were examined with respect to the effect of the flow rate, sample solvent, mobile phase strength and column temperature. It wass found that metal chelates were properly eluted in an acceptable range of capacity factor value($0{\leq}log\;k^{\prime}{\leq}1$). The dependence of the logarithm of capacity factor(k') on the volume fraction of water in the binary mobile phase was examined. Also, the dependence of k' on the liquid-liquid extration distribution ratio($D_c$) in methanol-water/n-alkane extration system was investigated. Both kinds of dependence are linear, which susggests that the retention of the electroneutral metal chelate is largely due to the solvophobic effect. Standard adsorption enthalpy changes (${\Delta}H^{\circ}$) and standard adsorption entropy changes (${\Delta}S^{\circ}$) of Pd(II) Isonitrosoethylacetoacetate imine chelates on Micropak MCH-5 column were calculated by measuring capacity factor with changing temperature of the column.

  • PDF

Directional Analysis on Intellectual Capital Indicators of Contract Foodservice Management Company in the Viewpoint of Contractor, Client, and Customer (위탁급식전문업체, 고객사, 고객 측면에서 위탁급식업의 지적자본 지표간 인과관계 분석을 통한 다자간 활용도 탐색)

  • Park Moon-Kyung;Yang Il-Sun
    • Journal of Nutrition and Health
    • /
    • v.38 no.9
    • /
    • pp.765-776
    • /
    • 2005
  • The purposes of this study were to a) examine IC (intellectual capital) circumstance of CFMC (contract foodservice management company), b) identify the correlation between IC of CFMC, c) analyze the cause and effect of IC in the viewpoint of contractor, client, and customer. The questionnaires of IC measurement were handed out to 108 CfHCs, there composing of main office employees, foodservice managers, customers, and clients of 207 school, 38 hospital, and 86 business/industry foodservices. The statistical data analysis was completed using SPSS Win (ver 12.0) for descriptive analysis, correlation analysis, simple linear regression analysis. First, CFMCs had operational experience for an average of 8 years and 8 months, and served an average of 38,540 meals a day. Most of the respondent companies operated 'food supply/distribution($50\%$)', 'catering ($46.7\%$)', and restaurant business ($43.3\%$)' except for institutional foodservice and managed an average of 66 clients for the contract period of 2 years and 3 months. Second, there was positive correlation between $\ulcorner$sales of foodservice$\lrcorner$ and 'market ability', $\ulcorner$client satisfaction$\lrcorner$ and necessary intellectual capital for managing branch/chain foodservice office, and $\ulcorner$customer satisfaction$\lrcorner$ and $\ulcorner$renewal and development$\lrcorner$, 'market ability', 'infrastructure support for foodservice operation', 'employee satisfaction', respectively. Finally, the result of the cause and effect analysis on CFMCs, clients, and customers was positively influenced by 'client satisfaction' with 'customer satisfaction', 'infrastructure support for foodservice operation' and 'customer satisfaction' with 'employee satisfaction', and 'infrastructure support for foodservice operation'. In conclusion, if CFMCs were to perform a routine checkups by utilizing CFMC's IC measuring tool, improvements in CFMC operational capacities as well as foodservice quality can be noted. Additionally, CFMCS can satisfy their client-customer relationship by employing internal marketing thechniques for employee, a more efficient infrastructure support system, and construc tive infrastructure utilization. Therefore, CFMCs can show significant improvement in their sales and foodservice quali-ty though continuous maintenance of the client and customer satisfaction.

A Spleen Size Measured by Ultrasound in 20's Normal Adults (초음파검사에 의한 20대 정상 성인의 비장 크기)

  • Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.337-343
    • /
    • 2020
  • An enlarged spleen can be caused by infections, cirrhosis and other liver diseases, blood diseases characterized by abnormal blood cells, problems with the lymph system, immune diseases, or other conditions. Therefore, knowing the normal size of the spleen is helpful for the diagnosis of spleen and may be useful for follow-up. Ultrasonographic examination may be considered normal size if the maximum length is less than 12 cm and less than 5 cm in thickness, but may vary depending on sex and race. We aimed to present the normal range of spleen size by measuring the spleen size by ultrasonography in 20's normal adult Korean. The length of the male spleen was 10.95±1.07 cm and the width was 4.48±0.61 cm. The female length was 9.20±1.30 cm and the width was 3.55±0.44 cm. There was a significant difference (p<0.001). The spleen length increased with increasing height (r=.57) and there was a significant positive linear relationship with increasing spleen length as body weight increased(r=.63). In normal adults, 5 men and 2 women had a spleen length of more than 12 cm and 2 men with a size exceeding 13 cm.

DEVELOPMENT OF FILTERING SYSTEM OF LASER FLUORESCENCE FOR IMPROVEMENT OF THE DIAGNOSTIC SENSITIVITY FOR DENTAL CARIES (레이저 형광법의 치아우식증 진단감도를 증진시키기 위한 필터링 시스템 개발)

  • Lee, Sang-Ho;Park, Jong-Whi;Kook, Jung-Ki;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.189-195
    • /
    • 2003
  • The objective of this study is to improve the optical sensitivity of laser fluorescence for detection of incipient enamel caries. An incipient carious lesion was formed in various stages by placing an enamel specimen of a bovine tooth in STPP demineralization solution. After measuring the optical density of the lesion surface by laser fluorescence induced by argon laser and various alter of yellow(500-520nm), amber(520-540nm), orange(540-560nm), and red(560-580nm), the specimen was cut vertically to measure the depth of the lesion using a polarizing microscope. SAS statistical program was used to analyze the relationship between the optical density of the lesion suface and the depth of the lesion. The results were as follows: 1. The optical density of early carious lesion, measured by laser fluorescence with amber and orange filter, and lesion depth observed by polarizing microscope, were increased as demineralization time increased. 2. The correlation coefficient between optical density of the lesion surface and the histological depth of the lesion was the highest in orange filter(r=0.49), followed by amber(r=0.32), yellow(r=0.13) and red(0.01). 3. Regression analysis showed that the most linear relationship between the optical density and the lesion depth was existed in orange filter group. In regard above results, laser fluorescence could be considered to be reliable for optical diagnosis of dental caries.

  • PDF

A Study on the Inter-Relational Interpretation of Street Plant Issues - Focus on Central Park Road in Incheon Metropolitan City - (가로수관련 문제유형의 관계론적 해석 - 인천광역시 중앙공원길을 중심으로 -)

  • Hong, Youn-Soon;Chung, Doo-Yong;Choi, Kang-Rim
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.1
    • /
    • pp.80-89
    • /
    • 2008
  • Generally, trees lining the streets are the most easily accessible green areas in the city and constitute the smallest basic unit in the formation of the urban linear green axis. This study attempts to interpret issues related to city trees from a comprehensive and relational viewpoint. The site of this study is Central Park Street in front of Incheon Metropolitan City Hall. This street is representative of those in Incheon City. This study is an inter-relational interpretation of issues by measuring the vitality of these trees. The following are results of this study: First, the vitality of city trees is higher in those trees growing in natural ground than those growing in plant gratings. This observation can lead to budget savings and increased natural areas in the city. Also, if planter and multi-layering planting methods are introduced where damage to trees is predicted, variation to urban landscape can be achieved while linking to reinforced rearing foundation of street-side trees. Second, there is need for a holistic approach to caring for street-side trees regarding the damage caused by drastic pruning and strong street lights. The typical functions of these trees, like supplying freshness in summer, absorbing solar radiation, and controlling the urban micro-climate are closely related to the vitality of the trees. Accordingly, the function and ecology should be understood holistically, not separately. In this aspect, the functional and ecological use of the multi-layering planting method is effective in protecting pedestrians from vehicles as well. Third, the fallen leaves of monotonous rows of trees have different ecological and functional effects. Not only is the index of greenness in the urban setting increased, but there are also aesthetic and symbolic effects. Fourth, in spite of being the street along which Incheon Metropolitan City Hall, major administrative buildings and Central Park are located, this street does not have its own special identity to discriminate it from other streets. It fulfills only functional criteria based on uniformity. If there is no paradigm shift from today's street system based on vehicles, the role of landscape architecture will be very passive in regards to street-side trees, the minimum unit of urban green. Fifth, on this particular street, many trees were planted in December, which reflects a deficiency of short and long-term strategy, like a street-tree master plan. In this aspect, we still lack a mature culture concerning these trees as a basic unit in urban greenery. Furthermore, there needs to be cultural introspection concerning present administrative practices.

Changes of Hysteresis Loop Characteristics of the Tendon Under Tensile Stress (Tendon의 인장응력에 따른 자기이력특성 변화의 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.123-128
    • /
    • 2015
  • The iron is an element having a high yield strength, mechanical hardness, good electrical conductivity, and also it has been used in various fields because of ease machining. In bridges have been used tendon made of a steel wire for large loads and light weight. Tension measurement of tendon employed in PreStressed Concrete (PSC) bridge is very important for the bridge safety check. NDT (Non-Destructive Testing) is essential for the safety check, however, magnetic NDT is difficult to apply due to the non-linear magnetization curve and hysteresis loop in the magnetic properties. In this work, for basic study of magnetic NDT application, we have constructed a B-H loop measuring system for 7-strand tendon of which diameter is 15.5 mm, and which can apply tensile stress up to 2.0 GPa. We have measured hysteresis loops of two kinds of tendons under different tensile stress. Amplitude permeability and maximum magnetic induction near knee show the most sensitive and high linearity depends on tensile stress. Relative amplitude permeability was decreased from 500 to 200 and maximum magnetic flux density changed 0.6 T.

Study on the Projectile Velocity Measurement Using Eddy Current Probe (와전류 탐촉자를 이용한 총구 탄속 측정에 관한 연구)

  • Shin, Jungoo;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.3
    • /
    • pp.83-86
    • /
    • 2015
  • Nowadays the weapon systems are employed air bursting munition (ABM) as smart programmable 40 mm shells which have been developed in order to hit the target with programmed munition that can be air burst after a set distance in the battlefield. In order to improve the accuracy of such a bursting time, by measuring the speed of the munition from the barrel, weapon systems calculate the exact time of flight to the target and then the time information must be inputted to the munition. In this study, we introduce a device capable of detecting a shot at K4 40 mm automatic grenade. The shot is composed of a rotating copper band to convert linear motion into rotary motion when it passes through the barrel, the steel section is exert the effect of fragment and aluminum section to give fuze information. The aluminum section was used to detect munition using eddy current method. To measure muzzle velocity by means of non-contact method, two eddy current probes separated 10 cm was employed. Time interval between two eddy current probe detection times was used as muzzle velocity. The eddy current probe was fabricated U-shape Mn-Zn ferrite core with enamelled copper wire, and 200 kHz alternating current was used to detect inductance change. Measured muzzle velocity using the developed sensor was compared to the Doppler radar system. The difference was smaller than 1%.