• 제목/요약/키워드: Linear measuring system

검색결과 297건 처리시간 0.028초

Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

Electrodermal Activity at the Left Palm and Finger in Accordance with the Pressure Stimuli Applied to the Left Scapula

  • Kim, Jae Hyung;Kim, Su Sung;Son, Jung Man;Kim, Yung Jae;Baik, Sung Wan;Jeon, Gye Rok
    • 센서학회지
    • /
    • 제25권4호
    • /
    • pp.235-242
    • /
    • 2016
  • A system for measuring the electrodermal activity (EDA) signal occurring at the sweat glands in the left palm and left finger of the human body was implemented in this study. The EDA measurement system (EDAMS) consisted of an algometer, a biopotential measurement system (BPMS), and a PC. Two experiments were performed to evaluate the function and clinical applicability of EDAMS. First, an experiment was carried out on the linearity of the voltage and the pressure that comprised the output signals of the algometer used for applying a pressure stimulus. Second, the amplitude of the EDA signal acquired from the electrode attached to the left palm or finger was measured while increasing the pressure stimulus of the algometer. When the pressure stimulus of the algometer applied to the left scapula was increased, the amplitude of the EDA signal increased. The amplitude of the EDA signal at the left palm was observed to be greater than that at the left finger. The amplitude of the EDA signal was observed to increase in a relatively linear relation with the intensity of the pressure stimuli. In addition, the latency of the EDA signal acquired from the electrode attached to the left palm or finger was measured while increasing the pressure stimulus of the algometer. When the pressure stimulus of the algometer applied to the left scapula was increased, the latency of the EDA signal decreased. The latency of the EDA signal at the palm was observed to be less than that at the finger. The latency of the EDA signal was observed to decrease nonlinearly with the pressure stimuli.

Improvement in Computation of Δ V10 Flicker Severity Index Using Intelligent Methods

  • Moallem, Payman;Zargari, Abolfazl;Kiyoumarsi, Arash
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.228-236
    • /
    • 2011
  • The ${\Delta}\;V_{10}$ or 10-Hz flicker index, as a common method of measurement of voltage flicker severity in power systems, requires a high computational cost and a large amount of memory. In this paper, for measuring the ${\Delta}\;V_{10}$ index, a new method based on the Adaline (adaptive linear neuron) system, the FFT (fast Fourier transform), and the PSO (particle swarm optimization) algorithm is proposed. In this method, for reducing the sampling frequency, calculations are carried out on the envelope of a power system voltage that contains a flicker component. Extracting the envelope of the voltage is implemented by the Adaline system. In addition, in order to increase the accuracy in computing the flicker components, the PSO algorithm is used for reducing the spectral leakage error in the FFT calculations. Therefore, the proposed method has a lower computational cost in FFT computation due to the use of a smaller sampling window. It also requires less memory since it uses the envelope of the power system voltage. Moreover, it shows more accuracy because the PSO algorithm is used in the determination of the flicker frequency and the corresponding amplitude. The sensitivity of the proposed method with respect to the main frequency drift is very low. The proposed algorithm is evaluated by simulations. The validity of the simulations is proven by the implementation of the algorithm with an ARM microcontroller-based digital system. Finally, its function is evaluated with real-time measurements.

DFIG 풍력발전기가 연계된 배전선로의 고조파 공진 특성에 관한 연구 (A Study on Harmonic Resonance in a DFIG Wind Turbine-generator Connected to a Distribution Power Line)

  • 최형주;이흥호
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1383-1389
    • /
    • 2013
  • There were telecommunication noise and malfunctions of the electronic devices occurred over a wide area due to the high harmonic voltage and/or current levels of the Back-to-back converter in the DFIG wind power system even though the magnitude of all harmonics is within the international standards. The triangular carrier signals of the PWM used in the power converter system is related to the telecommunication noise because they are in the range of audible frequencies and amplified by a variety of the standing waves that were excited by harmonic voltage sources in the weak grid system such as a long distance distribution transmission lines. This paper describes the characteristics of the harmonics in the wind turbine-generator, numerical analysis and simulation of the harmonics resonance phenomena in the distribution lines as well as measuring induced voltage of the telecommunication lines in parallel with power lines in order to verify the root cause of the telecommunication noise. These noise problems can occur in a wind turbine power system with a non-linear converter at any time, as well as photovoltaic power system. So, the preliminary review of suitable filter devices and switching frequencies of the PWM have to be required by considering the stability of the controller at the design stage but as part of the measures the effect of the telecommunication cable shields was analyzed by comparing the measured data between multi-conductor with/without shields so as to attenuate the sources of the harmonics voltage induced into the telecommunication lines and to apply the most cost-effective measures in the field.

지능형 누설왜곡전파신호 측정시스템 개발 (Implementation of Intelligent Measurement System of InterModulation Distorted RF Signals)

  • 김동현;서나현;박기원;이영철
    • 한국지능시스템학회논문지
    • /
    • 제27권2호
    • /
    • pp.144-149
    • /
    • 2017
  • 본 논문에서는 650MHz에서 2,700MHz의 주파수 대역에서 우수한 동적영역과 선형성 특성을 나타내는 RF-수신기를 설계하고, 왜곡신호(누설 또는 혼변조)를 측정할 수 있는 지능형, 광대역 RF-왜곡신호 계측시스템을 구현하였다. 광대역 특성의 RF-수신모듈은 저 잡음특성과 동적영역 관계를 분석하여 RF수신단의 선형화 파라미터를 최적화시켰다. 지능형 디지털-왜곡(혼변조) 측정시스템에서는 측정하려는 왜곡(혼변조)신호를 PC상의 GUI 로 처리하여 원하는 계측파라미터를 PC 모니터에 나타내었다. 설계된 계측장치를 650MHz-2700MHz 까지 가변시켜 왜곡신호를 측정한 결과, -127.8dBc에서 -138dBc까지 나타내어 지능형 디지털 계측기로 이용될 수 있음을 보였다.

Profile Measurements of Micro-aspheric Surfaces Using an Air-bearing Stylus with a Microprobe

  • Shibuya, Atsushi;Gao, Wei;Yoshikawa, Yasuo;Ju, Bing-Feng;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.26-31
    • /
    • 2007
  • A novel scanning probe measurement system was developed to enable precise profile measurements of microaspheric surfaces. An air-bearing stylus with a microprobe was used to perform the surface profile scanning. The new system worked in a contact mode and had the capability of measuring micro-aspheric surfaces with large tilt angles and complex profiles. Due to limitations resulting from the contact mode, such as possible damage caused by the contact force and lateral resolution restrictions from the curvature of the probe tip, several system improvements were implemented. An air bearing was used to suspend the shaft of the probe to reduce the contact force, enabling fine adjustments of the contact force by changing the air pressure. The movement of the shaft was measured by a linear encoder with a scale attached to the actual shaft to avoid Abbe errors. A $50-{\mu}m-diameter$ glass sphere was bonded to the tip of the probe to improve the lateral resolution of the system. The maximum contact force of the probe was 10 mN. The shaft was capable of holding the probe continuously if the contact force was less than 40 mN, and the resolution of the probe could be as high as 10 nm, The performance of the new scanning probe measurement system was verified by experimental data.

잉크젯을 이용한 디스플레이 생산을 위한 회전 미러 방식의 잉크젯 액적 모니터링 장비 및 측정법 연구 (High-Speed Monitoring Device to Inspect Inkjet Droplets with a Rotating Mirror and Its Measuring Method for Display Applications)

  • 신동윤
    • 대한기계학회논문집A
    • /
    • 제41권6호
    • /
    • pp.525-532
    • /
    • 2017
  • 차세대 주력 디스플레이인 유기 및 양자점 발광 다이오드를 잉크젯을 이용하여 저렴한 비용으로 생산하기 위한 연구개발이 진행되어 왔으며, 잉크 액적의 토출 신뢰성을 고속으로 검사하기 위한 모니터링 장비의 개발이 요구된다. 본 연구에서는 기존 직선 운동 방식의 잉크젯 모니터링 장비 대신에 로터리 및 리니어 초음파 모터를 이용하여 미러를 회전시킴으로써 노즐들에서 토출되는 잉크 액적들을 모니터링할 수 있는 장비를 개발하여 측정 능력을 시험하였다. $10{\mu}m$, $30{\mu}m$$50{\mu}m$ 직경 원형의 측정 오차는 각각 $0.5{\pm}1.0{\mu}m$, $-1.2{\pm}0.3{\mu}m$$0.2{\pm}0.5{\mu}m$였다. 모니터링 시간은 17초가 소요되었으며, 제어 프로그램의 최적화를 통해 8.6초까지 모니터링 시간을 단축할 수 있는 가능성을 확인하였다.

미나리를 이용한 계면활성성분 및 합성세제 제거에 관한 연구 (The Removal of Surfactants and Commercial Detergents by Oenanthe javanica)

  • 김경민;최한영;신정식;나규환;이장훈
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.115-120
    • /
    • 1997
  • The purpose of thesis was to investigate the removal efficiency of surfactants and commercial detergents by Oenanthe javanica that is one of aquatic plants in Korea. The experiment is concerned with measuring the concentrations of surfactants and commercial detergents in different media: 1) in pure water, 2) in water containing Oenanthe javanica, 3) in water containing Oenanthe javanica and commercial nutrients. The surfactants used in this research include linear alkylbenzene sulfonates (LAS), $\alpha$-sulfo fatty acid methyl esters(MES), and alkylbenzene sulfonates(ABS). Two commercial detergents designated as A and B were in the forms of power and liquid. The results showed that LAS and MES were more effectively removed by Oenanthe javanica probably because these have a chain of linear carbon than on ABS with a branched carbon structure. In the case of commercial detergents, when the except was performed on the basis of surfactants proportion, the removal trends were similar to LAS and MES. The 5-day cultivating test with initial concentration of 0.5-1.0 ppm surfactants showed that less than 10% was removed if no nutrients an Oenanthe javanica were added. When Oenanthe javanica was added into the sample solution containing surfactants, the removal efficiency was increased 100% for the solution containing 0.5-1.0 ppm 60-70% for 5-10 ppm. In addition, chlorisis on Oenanthe javanica was observed due to surfactants and commercial detergents for all three cases. To test the dependence of population density on nutrients, the initial population density was made 300 g/0.4 m$^2$. Throughout the 5-day experiment, the on Oenanthe javanica grew 20-25% with 0.5-1.0 ppm without the synthetic nutrients but by 5% with a high concentrations of 5-10 ppm. The population density was appeared to be independent of synthetic nutrients. The leaves were to be grown with synthetic nutrients, while roots were grown without synthetic nutrients. Based on this research, the fundamental data concerning cultivation and an adequate adjustment of the water condition can provide for the utilization of Oenanthe javanica in real water treatment system.

  • PDF

특성이 다른 지게차 적재 중량 센서의 초기 값 오차 보정 (Error Calibration of Initial Value of Weight Measuring Sensors with Different Feature of Forklift)

  • 한치문;임춘식;이성렬
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.214-220
    • /
    • 2019
  • 산업현장에서의 안전사고 빈도가 높은 지게차 전복의 주요 원인인 과적을 방지하기 위해 개발된 앵커(anchor) 볼트 형태의 strain 게이지 센서의 초기 값 오차를 보정하는 방법을 제안하였다. Strain 게이지 센서의 초기 값 오차는 앵커 볼트의 물리적이고 기계적 오차와 환경적 문제에기인하는 것을 확인하였다. 이러한 원인들을 제조 공정에서 제거하는 것은 본 연구의 범위를 벗어나는 것이기 때문에 제반 원인들을 고려한 보정 값을 찾고, 이 보정 값으로 strain 게이지 센서부를 구성하는 ADC 모듈의 초기 값을 보정하는 방법을 적용하였다. 보정 값 도출을 위하여 선형 보간법을 채택하였다. 도출한 보정 값을 4개의 strain 게이지 센서에 적용하여 시험한 결과 4개의 센서 모두 실제 중량 값과의 차이가 5% 이내가 되는 것을 확인하였다. 아울러 초기 값 보정 전에는 센서들의 ADC 값과 적재 중량 실제 값의 상관성이 없었던 점도 동시에 해결할 수 있었다.

Prediction of apparent total tract digestion of crude protein in adult dogs

  • Kangmin Seo;Hyun-Woo Cho;Min Young Lee;Chan Ho Kim;Ki Hyun Kim;Ju Lan Chun
    • Journal of Animal Science and Technology
    • /
    • 제66권2호
    • /
    • pp.374-386
    • /
    • 2024
  • To predict the apparent total tract digestibility (ATTD) of crude protein (CP) in dogs we developed an in vitro system using an in vitro digestion method and a statistical analysis. The experimental diets used chicken meat powder as the protein source, with CP levels of 20% (22.01%, analyzed CP value as dry-based), 30% (31.35%, analyzed CP value as dry-based), and 40% (41.34%, analyzed CP value as dry-based). To simulate in vivo digestive processes a static in vitro digestion was performed in two steps; stomach and small intestine. To analyze ATTD the total fecal samples were collected in eight neutered beagle dogs during the experimental period. CP digestibility was calculated by measuring CP levels in dog food, in vitro undigested fraction, and dog feces. In result, CP digestibility at both in vivo and in vitro was increased with increasing dietary CP levels. To estimate in vivo digestibility the co-relation of in vivo ATTD and in vitro digestibility was investigated statistically and a regression equation was developed to predict the CP ATTD (% = 2.5405 × in vitro CP digestibility (%) + + 151.8). The regression equation was evaluated its feasibility by using a commercial diet. The predicted CP digestibility which was calculated by the regression equation showed high index of similarity (100.16%) with that of in vivo in dogs. With that, it would be a feasible non-animal method to predict in vivo CP digestibility by using in vitro digestion method and the proposed linear regression equation in adult dogs.