• Title/Summary/Keyword: Linear Motion Error

Search Result 207, Processing Time 0.035 seconds

Development of Real-time Landslide Inspecting and Monitoring System

  • Hur Chul;Jeon, Yang-Bae;Kim, Choon-Sik;Kim, Sang-Bong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.243-243
    • /
    • 2000
  • This paper introduces a visual inspecting and monitoring system based on an image processing technique. We propose an image processing method for analyzing landslide movement in real time. The method adopts Laplacian of Gaussian operator to extract linear features for the captured images and uses a linear matching algorithm to distinguish the matching error for those features. When the algorithm is processed, motion parameters such as displacement area and its direction are computed. Once movement is recognized, displacements are estimated graphically with statistical amount in the image plane. The simulation results are shown us to verify the effectiveness of the developed method.

  • PDF

The Improvement of Position Precision for Hybrid Linear Pulse Motor

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.28-33
    • /
    • 2001
  • The subject of this study is to improve the position performance of the linear motion for hybrid type Linear Pulse Motor (HLPM). Generally, there are two applicable methods to ensure precise position control ; a good processing method. This paper is suggested an electrical 125 microstep driving method so as to achieves the excellent control performance, besides the small mechanical manufacture of teeth pitch. The compensation method of digital PI control is apply to step response of stable position control, step error, vibration suppression and the approach to high stability, and the Ziegler-Nichols tuning method is applied to the proper design of control parameter. The proposed control method has been verified by simulation results of the suitable gain and phase margin of bode plot, and from experiment result of step response.

High-Accuracy Motion Control of Linear Synchronous Motor Using Reinforcement Learning (강화학습에 의한 선형동기 모터의 고정밀 제어)

  • Jeong, Seong-Hyen;Park, Jung-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1379-1387
    • /
    • 2011
  • A PID-feedforward controller and Robust Internal-loop Compensator (RIC) based on reinforcement learning using random variable sequences are provided to auto-tune parameters for each controller in the high-precision position control of PMLSM (Permanent Magnet Linear Synchronous Motor). Experiments prove the well-tuned controller could be reduced up to one-fifth level of tracking errors before learning by reinforcement learning. The RIC compared to the PID-feedforward controller showed approximately twice the performance in reducing tracking error and disturbance rejection.

Finite Element Analysis on the Motion Accuracy of Hydrostatic Table ($2^{nd}$. Analysis and Experimental Verification on Double Sides Table) (FEM을 이용한 유정압테이블의 운동정밀도 해석 (2. 양면지지형 테이블의 해석 및 실험적 검증))

  • Park, Chun-Hong;Lee, Hu-Sang;Kim, Tae-Hyoung;Kim, Min-Gi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.65-70
    • /
    • 2002
  • An analysis method for calculating motion accuarcy of double sides hydrostatic table is proposed in this paper. In this method, profiles of each rails are assumed as periodic function, therefore it is represented as the sum of spacial frequencies. Bearing clearance at any position rail is depended on the variation of linear, angular motion error of table and the form errors of both sides of a rail. Finite element method is applied to calculate pressure distributions in bearing clearance. In order to simplify the analyzing process, double sides table model is converted into equivalent single side table model. Results calculated by the proposed modeling method agree well with the results directly caculated by double sides modeling method, and also agree well with experimental results. From the theoretical and experimental analysis, it is verified that the proposed analysis method is very effective to analyze the motion accuracy of double sides hydrostatic table.

Three dimensional finite element analysis of static deflections of a machine tool structures (3차원 유한요소 모델링을 통한 공작기계 구조의 정적 변형도 해석)

  • 김현석;이수정;정광섭;이대길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.638-643
    • /
    • 1993
  • The three dimensional finite element models for the basic deflection of linear motion guides and ball screws were developed. Form the comparison of the results calculated by the finite element method with those by the experiment, it was proved that the modeling method might be applied to real machine tool structures. Form the structural analysis of the headstock of the machine tool, it was found that the static stiffness was calculated within 6.5% error

  • PDF

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF

Analysis of Synchronization Error in R2R Gravure Off-set Printing Process (R2R 그라비어 오프-셋 인쇄공정에서의 동기화 오차에 대한 분석)

  • Lee, Taik-Min;Kim, In-Young;Park, Sang-Ho;Kim, Bong-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.10
    • /
    • pp.1141-1145
    • /
    • 2011
  • Recently, there are many issues about R2R printing technique for mass production of electronic devices. Among the various Roll-to-roll based printing techniques such as gravure, off-set, flexo and so on, "Gravure off-set printing technique" has an advantage of higher printing resolution. The printing unit of gravure off-set printing technique usually consists of plate roll, blanket roll and impressure roll whose. Linear velocities should be synchronized each other for fine pattern printing. However, roller's manufacturing error and printing variations such as pringting pressure, printing speed, roll stroke and so on actually affected their synchronization anf thus the quality of fine fattern. In this paper, we analyzed the effective of synchronization error on printing quality. Also, this paper reviews the relative motion with each roll. And, this paper studys the synchronization error about its generation problem.

A Study on the Feeding System of Centerless Grinder for Machining the Ferrule (페룰가공용 무심연삭기 이송계 개발)

  • 박천홍;황주호;조순주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.65-69
    • /
    • 2002
  • In order to practicalize high precision centerless grinder for machining the ferrule, its feeding system is designed and tested. For satisfying the desired diametric tolerance and cylindricity of the ferrule, the feeding system is designed to have relatively high axial stiffness of 600 N/$\mu\textrm{m}$, high angular motion accuracy of 0.5 arcsec/mm in yaw direction and minimum resolution of 0.05 $\mu\textrm{m}$. A prototype of feeding system is built up with hydrostatic guideway and ballscrew. A linear scale with 0.05 $\mu\textrm{m}$ of resolution is used for position feedback. Experimental results show that the feeding system has the infinity of axial stiffness within the range of 1000 N and 0.3 arcsec/mm of yawing error. Also the feeding system shows obvious step response against 0.05 $\mu\textrm{m}$/step command without the lost motion or backlash. Although the vertical stiffness is reduced to 440 N/$\mu\textrm{m}$ by the elastic deformation of rail, it is good enough to use for machining the ferrule. From above, it is confirmed that the feeding system is applicable to centerless grinder for machining the ferrule.