• Title/Summary/Keyword: Line-to-ground

Search Result 1,467, Processing Time 0.027 seconds

Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid (접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

Characteristics on the Neutral Point Potential of Line-to-Ground Voltage according to Line-to-Ground Fault in Resistance Ground System for Ships (선박의 저항접지 시스템에서 지락 고장에 따른 대지전압 중성점 전위 특성)

  • Lee, Yun-Hyung;Ryu, Ki-Tak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.689-696
    • /
    • 2018
  • System grounding is applied to the neutral point of a power source to secure the from any abnormal voltage and/or grounding fault. System grounding, which is applied mainly in ships is an ungrounded and resistance grounded system. Vessels using the MV power system with 3.3kV, 6.6kV, and 11kV mainly adopt a high resistance grounding system among the resistance grounding systems. The ground fault accounts for 95% of all faults occurring in the electrical system and when a fault occurs, the line-to-ground voltage of the power system is increased excessively, which adversely affects the onboard insulation system. This study analyzed the variation characteristics of the line-to-ground voltage neutral point according to the degree of ground fault in a resistance ground system applied in vessels. For this purpose, the characteristics of the grounding system were first explained, and the modeling of the neutral point potential of the line-to-ground voltage of the resistance grounding system in the vessels was derived. Finally, this study examined how the line-to-ground voltage, line voltage, and neutral point change according to various variable environments through MATLAB simulations.

Multi-channel Lidar Processing for Terrain Segmentation (지형분할을 위한 다채널 라이다 데이터 처리)

  • Chu, Phuong;Cho, Seoungjae;Sim, Sungdae;Kwak, Kiho;Cho, Kyungeun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.681-682
    • /
    • 2016
  • In this study we propose a novel approach to segment a terrain in two parts: ground and none-ground. The terrain is gained by a multi-channel 3D laser range sensor. We process each vertical line in each frame data. The vertical line is bounded by the sensor's position and a point in the largest circle of the frame. We consider each pair of two consecutive points in each line to find begin-ground and end-ground points. All points placed between a begin-ground point and an end-ground point are ground ones. The other points are none-ground. After examining all vertical lines in the frame, we obtain the terrain segmentation result.

Analysis on the Effects of the Induced Noise Voltage with the Impedance Changes of Telecommunication Line in the Power Inducting Situation (전력 유도 장애 발생 시 통신 선로의 접지체 임피던스 크기가 유도 잡음 전압에 미치는 영향 분석)

  • Choi, Mun-Hwan;Lee, Sang-Mu;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.227-230
    • /
    • 2007
  • In this paper, we have analyzed the change characteristics of induced noise due to the impedance change of the ground in both ends of telecommunication line. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. In the result of measurement, we can see the noise level change due to the change of the ground impedance, that is, as the ground impedance at either end of the telecommunication line become grower, the noise level is increased, and as the ground impedance at either end of the telecommunication line become smaller, the noise level is decreased. However, we can't define the relation between ground impedance size and PIF in these measurement results, so we will have to carry out the measurement more deeply and more practically with various conditions in environmental viewpoint and/or experimental viewpoint to establish the definition between ground impedance size and PIF.

  • PDF

An Analysis of Influence Between the Power Feeding Line Insulation and Negative Rail Potential for the DC Ground Fault Protection in the Rubber Wheel System (고무차륜시스템에서의 지락보호를 위한 급전선로 절연과 부극전위와의 영향 분석)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Young;Cho, Sanghoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.577-583
    • /
    • 2013
  • We have analyzed influence of potential rise in negative bus, which caused by decrease of power feeding line insulation, upon protecting method of DC ground protection device which detecting potential rise between negative bus and ground in order to detect ground fault in the rubber wheel system. For this purpose, we proposed negative potential equation between negative bus and ground and calculated negative potential according to system condition changes by estimating power feeding line insulation changes in steel wheel system and rubber wheel system, and equalizing DC power feeding system when ground fault occurred. Also, in order to estimate negative potential of real system, we modeled the rubber wheel system, and simulated normal status, grounding fault occurrence and power feeding line insulation changes. In normal status, negative potential did not rise significantly regardless of vehicle operation. When ground fault occurred, negative potential rose up over 300V regardless of fault resistance. However, we also observed that negative potential rose when power feeding line insulation dropped down under $1M{\Omega}$. In conclusion, our result shows that in case of rubber wheel system unlike steel wheel system, relay will be prevented maloperation and insulation status observation can be ensured when ground over voltage relay will be set 200V ~ 300V.

Analysis of Fire Accident on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재사고 사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Nam, Jung-Woo;Kim, Jin-Pyo;Park, Nam-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.18-23
    • /
    • 2010
  • This paper describes a cause of fire accidents on power system fire DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accident of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it makes progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial overvoltages and/or lightning one. The deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. Finally, the power failures would be causative of the fire accident.

Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재 사고사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

Ground fault protective relaying schemes for DC traction power supply system (비접지 DC 급전계통에서 전류형 지락보호계전 방법)

  • 정상기;정락교;이성혁;김연수;조홍식
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.412-417
    • /
    • 2004
  • In urban rail transit systems, ground faults in the DC traction power supply system are currently detected by the potential relay, 64P. Though it detects the fault it cannot identify the faulted region and therefore the faulted region could not be isolated properly. Therefore it could cause a power loss of the trains running on the healthy regions and the safety of the passengers in the trains could be affected adversely. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. A current limiting device, called Device X, is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. One type of the relaying schemes is called directional and differential ground fault protective relay which uses the current differential scheme in detecting the fault and uses the permissive signal from neighboring substation to identify the faulted region correctly. The other is called ground over current protective relay. It is similar to the ordinary over current relay but it measures the ground current at the device X not at the power feeding line, and it compares the current variation value to the ground current in Device X to identify the correct faulted line. Though both type of the relays have pros and cons and can identify the faulted region correctly, the ground over current protective relaying scheme has more advantages than the other.

A Study on the Ground Fault Current Distribution by Single Phase-to-Neutral Fault Tests in Power Distribution System (배전계통에서 1선 지락고장 시험에 의한 지락고장전류 분류에 관한 연구)

  • Kim, Kyung-Chul;You, Chang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.37-44
    • /
    • 2013
  • Phase to ground faults are possibly one of the maximum number of faults in power distribution system. During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multigrounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A simplified equivalent circuit model for the distribution system under case study calculated by using MATLAB gives results very close to the ground fault current distribution yielded by field tests.

Basic RF Characteristics of Fishbone-Type Transmission Line Employing Comb-Type Ground Plane (FTLCGP) on PES Substrate for Use in Flexible Passive Circuits

  • Yun, Young;Jeong, Jang-Hyeon;Kim, Hong Seung;Jang, Nakwon
    • ETRI Journal
    • /
    • v.37 no.1
    • /
    • pp.128-137
    • /
    • 2015
  • In this work, a fishbone-type transmission line employing a comb-type ground plane (FTLCGP) was fabricated on polyethersulfone (PES) substrate, and its RF characteristics were thoroughly investigated. According to the results, it was found that the FTLCGP on PES showed periodic capacitance values much higher than other types of transmission lines due to a coupling capacitance between the signal line and ground, which resulted in a reduction of wavelength and line width. Using the theoretical analysis, we also extracted the bandwidth characteristic of the FTLCGP on PES. According to the result, the FTLCGP structure showed a cut-off frequency of 280 GHz.