• 제목/요약/키워드: Line-source model

Search Result 270, Processing Time 0.026 seconds

A Study of the Effect of Grouting Region on the Solution of Line Source Analysis (그라우팅 영역이 선형열원 해석에 미치는 영향에 관한 연구)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.143-150
    • /
    • 2010
  • Line source method of borehole system assumes the entire surrounding medium is uniform. However, thermal properties of grouting region are considerably different from those of surrounding soil. In this study we investigate the effect of grouting materials on the solution of line source method with the aid of numerical analysis. This numerical model generates the temperature of borehole fluid with which line source solution can be obtained. Then this solution can be compared with input condition of numerical model. The results of this comparison show that thermal conductivity and borehole thermal resistance of line source solution are approximately 86% and 91% of the input condition of numerical model. Chart method is developed in this study to find the numerical input conditions (thermal conductivity and borehole thermal resistance) from the line source solution. Thermal response test of test borehole is conducted, the results of which are approximately consistent with the Chart method. Thermal property changes of grouting materials on the line source solution are also examined.

Synthesis of Earthquake Ground Motion by Combining Stochastic Line Source Model with Elastic Wave Propagation Analysis Method in a Layered Half Space (추계학적 선진원 모델과 층상반무한체에서의 탄성파 전파 해석법에 의한 지진 지반운동 합성)

  • KIM, Jae Kwan;KWON, Ki Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.97-105
    • /
    • 1996
  • A Stochastic line source model is developed to simulate the seismic wave field generated during the rupture propagation process along a fault plane of which length is much larger than its width. The fault plane is assumed to consist of randomly distributed slip zones and barriers and each slip zone is modeled as a point source. By combining the newly developed source model with wave propagation analysis method in a layered 3-D visco-elastic half space, synthetic seismograms are obtained. The calculated accelerograms due to vertical dip slip and strike slip line sources are presented.

  • PDF

Connected Characteristics for Small Generation Source of Low Voltage Model Grids (저압 모의선로에 소형발전원 연계시 특성)

  • Lee, Sang-Woo;Kang, Jin-Kyu;Lee, Dong-Ha;Park, Tae-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the typical phase voltage and line current waveform characteristics of the distribution system with 3 phase small synchronous generation source in case with load and non-load group, in order to investigate the power quality for end load connected of generation source. As demonstrated by our experimental results, the distortion and power quality of phase voltage and line current waveform were relatively good for low voltage 3 phase model grids connected of 3 phase small synchronous generation source in case with non-load group. However, distortion and power quality of voltage and current waveform was poor for low voltage 3 phase model grids connected to 3 phase small synchronous generation source in the load group with some phase voltage and frequency difference. From the above results, we conclude that the phase voltage and frequency of 3 phase generation source must be identical to that of distribution system source to maximize the power quality. Also, special attention is required in case of having load group or non-load group to 3 phase generation source.

Study of the propagation problem in the curved source of vibration (곡선진동원에서의 진동전파문제 연구)

  • Oh, Jang-Haun;Huh, Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1112-1115
    • /
    • 2004
  • Recently, KTX start service 2004 and speed up the Chung-ang line and Ho-nam line using tilting train. When the train speed up at curve the vibration environment are changed. It is the reason of the wave propagation problem in the curved source. In this research, using SSI Program SASSI, Predict the vibration propagation around the curved source of vibration. The curved source of vibration propagation is different from straight source of vibration propagation. In this study, made a curved vibration source model and compared with straight model.

  • PDF

An equivalent Circuit Model of Transformer Coupled Plasma Source (축전 용량이 고려된 평판형 유도 결합 플라즈마 원의 등가회로 모델)

  • Kim, Jeong-Mi;Kwon, D.C.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1760-1762
    • /
    • 2002
  • In this work we develop an equivalent circuit model of TCP(transformer coupled plasma) source and investigate matching characteristic. The developed circuit model includes transmission line, standard-type impedance matching network and displacement current in the plasma source. The impedance of TCP is calculated by previously developed program for various source parameters and dependance of components of matching impedance on the value of source impedance is investigated.

  • PDF

Indentification of Coherent/Incoherent Noise Sources Using A Microphone Line Array (독립, 비독립 음원이 동시에 존재할 경우 선형 마이크로폰 어레이를 이용한 소음원 탐지 방법)

  • 김시문;김양한
    • Journal of KSNVE
    • /
    • v.6 no.6
    • /
    • pp.835-842
    • /
    • 1996
  • To identify the locations and strengths of acoustic sources, one may use a microphone line array. Apparent advantage of the source identification method utilizing a line array is that it requires less measurement points than intensity method and holography. This method is based on the information of magnitude and phase difference between pressure signals at each microphone. Since those differences are dependent on the source model, we have to assume them such as plane, monopole, etc. In this paper the conventional source identification methods such as beamforming method and MUSIC method are briefly reviewed by modeling a source as plane and spherical wave, then a modified method is introduced. This can be applied to sound field which may by either coherent or incoherent. Typical simulations and experiment are performed to confirm this identification method.

  • PDF

A Study of Borehole Thermal Behavior with 1-Dimensional Model;Field Test Analysis included (1차원 모델에 의한 보어홀 열거동 해석 및 현지측정)

  • Kim, Dae-Ki;Woo, Joung-Son;Ro, Jeong-Geun;Lee, Se-Kyoun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.550-554
    • /
    • 2007
  • A one-dimensional heat transfer model coupled with parameter estimation is developed in this study to predict the effective thermal conductivities of soil formation and borehole resistances from in situ field test data. In this application a new method of using initial ignoring time(IIT) obtained from error estimation is tried and turned out to be successful in determining soil thermal conductivities. The validity of this model is accomplished through comparison of the predicted temperature profiles of the model with the data from laboratory scale experimental setting. Eleven test boreholes were constructed in Ochang, Chungcheong Buk Do, and thermal response test was carried out with each borehole. The results of the in situ tests were analyzed with our 1-D numerical model and compared with the results of line source method. The comparison shows that the thermal properties from line source method is a little lower (${\sim}95%$)than those from numerical method. The reason of such result seems to be the lower thermal conductivity of grout material, which is not counted in line source method.

  • PDF

EMTP SIMULATION MODEL TO ANALYZE DYNAMIC INTERACTION BETWEEN STATCON AND TRANSMISSION SYSTEM (STATCON과 송전계통의 동적응동 분석을 위한 EMTP 시뮬레이션 모델)

  • Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.446-448
    • /
    • 1995
  • This paper dscribes a detail simulation model with EMTP (Electro-Magnetic Transients Program) which is very effective to analyze the interaction between the ac transmission line and STATCON (static condenser). The SATCON was represented by two voltage-source converters connected in parallel and sharing an energy storage dc capacitor bank. The voltage source converters was modeled with ideal gate turn-off switches. The power system was represented by a detail generator model and a distributed tramnsmission line model for detail performance analyses. Analysis results show that the conceived simulation model is very effective to analyze the interaction between the ac transmission line and STATCON, and to evaluate the performance of STATCON.

  • PDF

A Study of Determining Initial Ignoring Time of Line Source Model used in Estimating the Effective Soil Formation Thermal Conductivities (지중유효열전도율 해석에 사용되는 선형열원 모델의 초기제외시간 결정에 관한 연구)

  • Lee, Se-Kyoun;Woo, Joung-Son;Kim, Dae-Ki
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.167-174
    • /
    • 2008
  • Line source model is commonly used in analyzing the data obtained from thermal response test to estimate the effective soil formation thermal conductivity. In the application of line source model some part of initial data must be ignored in order to achieve more accurate result. The period of time for this initial data is called initial ignoring time(IIT) in this paper. However there has been no definite rule in determining this initial ignoring time. Therefore line source model requires experienced analyzer to select the useful data, which is somewhat subjective. One method often suggested is the calculation of IIT with non dimensional time $\tau=5$. However, this is a very theoretical result derived from a system of perfect line source model, which is somewhat different from the real system. A new method to determine IIT is presented in this study. This method requires error estimation first and IIT can be decided from the results of error estimation. This method is applied in the analysis of field test data and shows better result than the one obtained from the method using non dimensional time mentioned above as shown in Table 2.

A Study on the Atmospheric Environmental Capacity in Chungju Area (충주지역의 대기환경용량 추정에 관한 연구)

  • Park, Sang-Chan;Yeon, Ik-Jun;Cho, Byeong-Real;Cho, Jung-Sik;Kang, Byung-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.122-127
    • /
    • 2008
  • The purpose of this study is to calculate atmospheric environmental capacity for $PM_{10}$, $NO_2$ and $SO_2$ using a rollback model in Chungju. From the results of this study, the source contributions for $PM_{10}$ and $NO_2$ was the following order: line source > area source > point source. However, the source contributions for $SO_2$ was the following: point source > area source > line source. While the atmospheric environmental capacity of $NO_2$ and $SO_2$ was enough to meet the regional air quality target, $PM_{10}$ emission needs to be reduced by 5%.