FVF-Based Low-Dropout Voltage Regulator with Fast Charging/Discharging Paths for Fast Line and Load Regulation

  • Hinojo, Jose Maria;Lujan-Martinez, Clara;Torralba, Antonio;Ramirez-Angulo, Jaime
    • ETRI Journal
    • /
    • 제39권3호
    • /
    • pp.373-382
    • /
    • 2017
  • A new internally compensated low drop-out voltage regulator based on the cascoded flipped voltage follower is presented in this paper. Adaptive biasing current and fast charging/discharging paths have been added to rapidly charge and discharge the parasitic capacitance of the pass transistor gate, thus improving the transient response. The proposed regulator was designed with standard 65-nm CMOS technology. Measurements show load and line regulations of $433.80{\mu}V/mA$ and 5.61 mV/V, respectively. Furthermore, the output voltage spikes are kept under 76 mV for 0.1 mA to 100 mA load variations and 0.9 V to 1.2 V line variations with rise and fall times of $1{\mu}s$. The total current consumption is $17.88{\mu}V/mA$ (for a 0.9 V supply voltage).

피드백 감지 회로 구조로 인한 향상된 Load Regulation 특성을 가진 LDO 레귤레이터 (LDO Regulator with Improved Load Regulation Characteristics and Feedback Detection Structure)

  • 정준모
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.1162-1166
    • /
    • 2020
  • 본 논문에서는 피드백 감지 회로 구조로 인하여 향상된 load regulation 특성을 개선시킨 LDO를 제안하였다. LDO 레귤레이터 내부 오차증폭기의 출력단과 패스 트랜지스터의 입력단 사이에 제안된 feedback 감지 회로를 추가하여 출력에 들어오는 델타 값의 regulation을 개선시켜 기존의 LDO 레귤레이터보다 개선된 load Regulation 특성의 전압 값을 갖는다. 제안된 회로는 Cadence의 Spectre, Virtuoso 시뮬레이션을 이용하여 삼성 0.13um 공정에서 특성을 시뮬레이션 하였다.

고효율 및 소형 스위치모드 라인 트랜스포머 (High Efficiency and Small Size Switch Mode Line Transformer(SMLT))

  • 김진홍;양정우;장두희;강정일;한상규
    • 전력전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.237-243
    • /
    • 2019
  • A high-efficiency and small-sized switched-mode line transformer (SMLT) is proposed in this study. The conventional structure of an adapter is composed of line transformer and rectifiers. This structure has a limit in miniaturizing due to low-frequency line transformer. Another structure is composed of power factor correction (PFC) and DC/DC converter. This structure has a limit in reducing volume due to two-stage structure. As the proposed SMLT is composed of an LLC resonant converter, a high-frequency transformer can be adopted to achieve isolation standards and size reduction. This proposed structure has different operation modes in accordance with line input voltage to overcome poor line regulation. In addition, the proposed SMLT is applied to the front of a conventional PFC converter, because the SMLT output voltage is restored to rectified sinusoidal wave by using a full-bridge rectifier in the secondary side. The design of the PFC converter is easy, because the SMLT output voltage is controlled as rectified sinusoidal wave. The validity of the proposed converter is proven through a 350 W prototype.

경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (II) (Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (II))

  • 김주락;창상훈;박현준;이영흠
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1984-1990
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

공진특성을 가지는 온도제어시스템의 스위칭 기법 연구 (A Study for the Switching Method of the Temperature Control System with the Resonance Feature)

  • 박활곤;박철우;최연호;구본호;권우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.87-90
    • /
    • 2003
  • There are generally two temperature control methods using ac voltage regulators - the phase control method and the on-off control method. The phase control method uses thyristor's angles of extinction for the output power regulation and the on-off control method uses the control of on and off times for the output power regulation. Both of methods have the problems that are the unbalance of the three phase and surge current caused system's destruction. The main object of this study proposes a solution of problems of surge currents and unbalance of three phase when thyristor voltage regulator is switching. To solve the problem, It is proposes that the solution of surge currents is using a tap transformer and an additional switch with adjustable resistance and applies zero crossing of switching voltage of two input line to power load. This method is discuss and verified by computer simulations and experiments.

  • PDF

Design of an Input-Parallel Output-Parallel Multi-Module DC-DC Converter Using a Ring Communication Structure

  • Hu, Tao;Khan, Muhammad Mansoor;Xu, Kai;Zhou, Lixin;Rana, Ahmad
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.886-898
    • /
    • 2015
  • The design feasibility of a micro unidirectional DC transmission system based on an input-parallel output-parallel (IPOP) converter is analyzed in this paper. The system consists of two subsystems: an input-parallel output-series (IPOS) subsystem to step up the DC link voltage, and an input-series output-parallel (ISOP) subsystem to step down the output voltage. The two systems are connected through a transmission line. The challenge of the delay caused by the communication in the control system is addressed by introducing a ring communication structure, and its influence on the control system is analyzed to ensure the feasibility and required performance of the converter system under practical circumstances. Simulation and experiment results are presented to verify the effectiveness of the proposed design.

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part II : Simulation and Experimental Results

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.27-34
    • /
    • 2003
  • In this paper, the power conditioner composed of the stand-alone single-phase squirrel cage rotor type self-excited induction generator (SEIG) driven by prime movers such as a wind turbine and a micro gas turbine (MGT) is presented by using the steady-state circuit analysis based on the two nodal admittance approaches using the per-unit frequency in addition to a new state variable defined by the per-unit slip frequency along with its performance evaluations for the stand-alone energy utilizations. The stande-alone single-phase SEIG operating performances in unregulated voltage control loop are then evaluated on line under the conditions of the speed change transients of the prime mover and the stand-alone electrical passive load power variations with the simple theoretical analysis and the efficient computation processing procedures described in the part I of this paper. In addition, a feasuible PI controlled feedback closed-loop voltage regulation scheme of the stande-alone single-phase SEIG is designed on the basis of the static VAR compensate. (SVC) and discussed in experiment for the promising stand-alone power conditioner. The experimental operating performance results are illustrated and give good agreements with the simulation ones. The simulation and experimental results of the stand-alone single-phase SEIG with the simple SVC controller for its stabilized voltage regulation prove the practical effectiveness of the additional SVC control loop scheme including the PI controller with fast response characteristics and steady-sate performance improvements.

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

입력 능동 부스트 컨버터를 고려한 역률개선회로의 특성분석 (A study on the characteristics of power factor correction circuits with input active boost converter)

  • 장준영;이관용;김철진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.270-272
    • /
    • 2003
  • Switching power supplies are widely used in many industrial fields. Power factor correction(PFC) circuits have tendency to be applied in new power supply designs. The input active power factor correction(APFC) circuits can be implemented using either the two-stage approach or the single-stage approach. The single-stage PFC circuit has advantage to reduce the number of components by eliminating a need for the PFC switch and control circuit. However, unlike in the two-stage approach, the do voltage on the energy storage capacitor in a single-stage PFC circuit is not well regulated. As a result. in universal line application($90{\sim}265Vac$), the storage capacitor voltage varies with the load and line variation. In this paper, the performance of output voltage regulation and transient response are clarified here. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results of 2 [kW] prototype converter.

  • PDF

Low Cost Power System Design for Plasma Display Panel(PDP)

  • Yoo, Kwang-Min;Lee, Jun-Young;Lim, Sung-Kyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.250-255
    • /
    • 2006
  • A low cost PDP sustain power supply is proposed based on flyback topology using Boundary Conduction Mode(BCM) to control input current regulation. This method guarantees DCM condition to regulate the input current harmonics under all load conditions. An excessive voltage stress due to the link voltage increase can be suppressed by removing link capacitor and adjusting transformer turns ratios, which makes it possible to be used for universal line applications. The proposed converter is tested with a 400W(200V-2A output) prototype circuit.

  • PDF