• Title/Summary/Keyword: Line test

Search Result 4,445, Processing Time 0.03 seconds

A Study for Running Test Result of Train Powering/Braking Control by TCMS (TCMS에 의한 전동차 추진/제동 제어기술의 현차시험 결과 고찰)

  • 박성호;한정수;신광균;박계서
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.652-658
    • /
    • 2000
  • TCMS(Train Control & Management System) control monitor and test the main on-board equipments including propulsion/brake unit by the serial transmission line. TCMS reduces interface circuits and number of train lines by the software logic and utilizing serial communication method. This paper describes the method of powering and braking control by TCMS software logic, and the software logic is verified by running test at Seoul Subway Line# 6. By running test result, we can see TCMS successfully control Powering/Braking of train

  • PDF

Analysis of Electrical Safety Level Test for Barehand Work at 765kV Vertical Double Circuit Six Bundle Conductors on the Suspension String Tower Type (765kV 수직2회선 6도체 현수형 철탑에서 직접활선작업의 안전성 평가분석)

  • Kim, Dae-Sik;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • It has been issued that the necessity of Live line work for 765kV vertical double circuit six bundle conductors transmission line when the characteristics of transmission line, the composition of T/L and near the T/L circumstances etc. Others are considered. The Barehand method of UHV T/L is extremely dangerous work and especially it is directly related with lineman life so it is very dangerous. It should be performed several technology developments for live-line work on the UHV T/L, that should be considered such as the electrical influence on workers near the T/L, development of live-line facilities, guarantee of safety, the technical rules of live-line work, the safe method of live-line work and etc. In order to maintain the 765kV transmission lines safely by barehand work, first of all, we should know the analysis of electrical safety level test in live-line work at 765kV vertical double circuit six bundle conductors on the suspension string tower type.

Analysis on Ventilation Performance of Natural Ventilation Systems in Multi-Family Housing Using Blower Door Test (Blower Door Test를 이용한 공동주택 자연환기시스템의 환기성능 분석)

  • Kim, Min Seok;Auh, Jin Sun;Hong, Goopyo;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.129-134
    • /
    • 2016
  • Today, natural ventilation systems are widely applied in multi-family housing. However, studies using the wind data trend line of the blower door test are insufficient. Purpose: Through this study, we will propose a computational method about ventilation performance of natural ventilation systems by conducting blower door test. Method: First, we sealed the gaps between the main systems including the natural ventilation system and conducted the blower door test. Next, the natural ventilation system was opened, the blower door test was conducted, and the difference in air flow rate between when closed and when opened was checked. Blower door test was carried out with a pressure difference of 50 Pa. Result: Therefore, the ventilation performance of the natural ventilation system was checked by drawing a trend line using the data to calculate the air flow rate at 2 Pa of the natural ventilation equipment standard pressure difference.

Study on Performance and Aging Test of Porcelain Insulators for Transmission Line (송전용 자기재 애자의 성능평가 및 가속열화시험)

  • 한세원;조한구;박기호;이동일;최인혁
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

Experimental Study on Firing Test of LPI Engine Using Gasoline Fuel for Improving the Production Process at End of line (엔진 착화 라인의 생산성 향상을 위한 LPI 엔진 가솔린 연료 적용성에 대한 실험적 연구)

  • Hwang, In-Goo;Choi, Seong-Won;Myung, Cha-Lee;Park, Sim-Soo;Lee, Jong-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.133-140
    • /
    • 2007
  • The purpose of this study was to evaluate the effects of gasoline fuel to the LPI engine. Firing test bench was used in order to assess the effect on gasoline-injected LPI engine. Gasoline fuel was supplied into the reverse direction(3-4-2-1 cylinder) at 3.0 bar with commercial gasoline fuel pump. Engine test was performed using the firing test mode at end of line. The deviations of excess air ratio of each cylinder and maximum combustion pressure using gasoline fuel were within 0.1 and $1{\sim}2\;bar$. Engine start time was measured with changing coolant temperature at $20^{\circ}C,\;40^{\circ}C,\;80^{\circ}C$, respectively. Residual gasoline volume in the fuel line was measured about 32 cc after firing test and it was less than 2 cc within 10 seconds purging. To simulate the end of line, the residual gasoline in the fuel line was purged during 5 and 10 seconds. Start time of LPI engine with LPG fuel were 0.61 and 0.58 seconds. This work showed that severe problems such as misfiring and liner scuffing were not occurred applying gasoline fuel to LPI engine.

A Study on the Vehicle Vibration Mode through the On-line Test for Korean High Speed Train (한국형 고속전철의 주행시험을 통한 진동 모드 분석 연구)

  • 박찬경;김영국;김석원;김기환
    • Proceedings of the KSR Conference
    • /
    • 2003.10a
    • /
    • pp.156-161
    • /
    • 2003
  • Korean High Speed Train (KHST) has been tested on high speed line in JungBu site since it was developed in 2002. The data acquisition system was used to test successfully the on-line test for proving the dynamic performance of KHST. The recognition of system vibration mode for railway vehicle is essential to understand the characteristics of design for dynamic system and diagnose the dynamic problems of vehicle system during test and operation. But, up to now, there are the efforts to know the system vibration mode within limit of theoretical field only, not experimental approach with systematic method. The theoretical results are too reliable to apply to real design problem, because it is theoretically based on the homogeneous linear system although the real system have the nonlinear characteristics and vary the environmental conditions. Therefor, in this paper, it is proposed the efficient method of vibration analysis for rail vehicle system and this method apply to KHST to recognize the vibration mode characteristics of it. The results show that this method is able to make the system vibration modes for KHST clear.

  • PDF

Safety Assurance of Dropper Clamp in Overhead Catenary System(I) (전차선로 드롭바 클램프 안전성 확보(I))

  • Lee, Ki-Won;Cho, Yong-Hyeon;Park, Young;Min, Byung-Il;Kwon, Sam-Young;Seok, Chang-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.223-226
    • /
    • 2007
  • In the electrical railway, for the improvement of a train speed, it is necessary to study not only the dynamic behaviors of overhead catenary system but the fatigue behaviors of components for a safety assurance according to the increase of vibration level. One of the critical components in the system is a dropper. Therefore, the dynamic force acting on a dropper was measured in the Chungbuk Line and analyzed to figure out the dynamic characteristics the dropper. And in order to assure the safety of dropper clamp and cable, we proposed a test facility as well as test method based on the test results For the further study, we will measure the dynamic forces in the conventional line and high-speed line and make up the test condition, so that the safety of dropper clamps can be assured.

  • PDF

Development of Automatic Data Acquisition & Remote Diagnostic System for Improving Efficiency of High-Voltage Motors Off-Line Insulation Diagnostic Test (고압전동기 Off-Line 절연진단시험 효율개선을 위한 데이터자동취득 및 원격진단시스템 구축)

  • Kang, Sang-Mu;Kang, Dae-Jeong;Han, Hyun-Seok;Kim, Won-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.707-708
    • /
    • 2015
  • This paper proposes a method for improving efficiency of high-voltage motors off-line insulation diagnostic test. The conventional manual test method has measurement errors and excessive processing time. We developed the KITAS system and solved these problems by using the instrument remote control and communication technology. The result of proficiency testing by interlaboratory comparisons using Power Factor Tip-Up test was '${\mid}E_n{\mid}$ < 1'. It was possible to confirm the validity of acquired data from the KITAS and establish a remote diagnostic system for easy access without physical limitations.

  • PDF

An Efficient Built-in Self-Test Algorithm for Neighborhood Pattern- and Bit-Line-Sensitive Faults in High-Density Memories

  • Kang, Dong-Chual;Park, Sung-Min;Cho, Sang-Bock
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.520-534
    • /
    • 2004
  • As the density of memories increases, unwanted interference between cells and the coupling noise between bit-lines become significant, requiring parallel testing. Testing high-density memories for a high degree of fault coverage requires either a relatively large number of test vectors or a significant amount of additional test circuitry. This paper proposes a new tiling method and an efficient built-in self-test (BIST) algorithm for neighborhood pattern-sensitive faults (NPSFs) and new neighborhood bit-line sensitive faults (NBLSFs). Instead of the conventional five-cell and nine-cell physical neighborhood layouts to test memory cells, a four-cell layout is utilized. This four-cell layout needs smaller test vectors, provides easier hardware implementation, and is more appropriate for both NPSFs and NBLSFs detection. A CMOS column decoder and the parallel comparator proposed by P. Mazumder are modified to implement the test procedure. Consequently, these reduce the number of transistors used for a BIST circuit. Also, we present algorithm properties such as the capability to detect stuck-at faults, transition faults, conventional pattern-sensitive faults, and neighborhood bit-line sensitive faults.

  • PDF

Integral effect test for steam line break with coupling reactor coolant system and containment using ATLAS-CUBE facility

  • Bae, Byoung-Uhn;Lee, Jae Bong;Park, Yu-Sun;Kim, Jongrok;Kang, Kyoung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2477-2487
    • /
    • 2021
  • To improve safety analysis technology for a nuclear reactor containment considering an interaction between a reactor coolant system (RCS) and containment, this study aims at an experimental investigation on the integrated simulation of the RCS and containment, with an integral effect test facility, ATLAS-CUBE. For a realistic simulation of a pressure and temperature (P/T) transient, the containment simulation vessel was designed to preserve a volumetric scale equivalently to the RCS volume scale of ATLAS. Three test cases for a steam line break (SLB) transient were conducted with variation of the initial condition of the passive heat sink or the steam flow direction. The test results indicated a stratified behavior of the steam-gas mixture in the containment following a high-temperature steam injection in prior to the spray injection. The test case with a reduced heat transfer on the passive heat sink showed a faster increase of the P/T inside the containment. The effect of the steam flow direction was also investigated with respect to a multi-dimensional distribution of the local heat transfer on the passive heat sink. The integral effect test data obtained in this study will contribute to validating the evaluation methodology for mass and energy (M/E) and P/T transient of the containment.