• Title/Summary/Keyword: Line loss

Search Result 1,650, Processing Time 0.028 seconds

Development on the Process Control System for Full Gate Visual Test of LCD Manufacturing Process (LCD 생산공정의 전게이트 시각 검사를 위한 공정 제어장치 개발)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1725-1728
    • /
    • 2009
  • This research developed process control device and FGV pattern generating device essential for full gate visual inspection to improve process so that defect detection capability may be maximized in specified environment. The devices developed in this research, which can be swiftly replaced in case loss or error occurs, are anticipated to improve module yield as well as maintain tact loss near '0'. In addition, as a result of mounting H/W and S/W system to control detailed operation sequence in production line and executing performance check and verification, detection rates were 98.1% and 99.1% respectively for pixel defect by tact and line defect, and yield of the entire module process including gate and visual level test increased up to 98.3%.

Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

  • Bae, Hwang;Kim, Dong Eok;Ryu, Sung-Uk;Yi, Sung-Jae;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.968-978
    • /
    • 2017
  • Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal-hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

An Optimization Method for the Calculation of SCADA Main Grid's Theoretical Line Loss Based on DBSCAN

  • Cao, Hongyi;Ren, Qiaomu;Zou, Xiuguo;Zhang, Shuaitang;Qian, Yan
    • Journal of Information Processing Systems
    • /
    • v.15 no.5
    • /
    • pp.1156-1170
    • /
    • 2019
  • In recent years, the problem of data drifted of the smart grid due to manual operation has been widely studied by researchers in the related domain areas. It has become an important research topic to effectively and reliably find the reasonable data needed in the Supervisory Control and Data Acquisition (SCADA) system has become an important research topic. This paper analyzes the data composition of the smart grid, and explains the power model in two smart grid applications, followed by an analysis on the application of each parameter in density-based spatial clustering of applications with noise (DBSCAN) algorithm. Then a comparison is carried out for the processing effects of the boxplot method, probability weight analysis method and DBSCAN clustering algorithm on the big data driven power grid. According to the comparison results, the performance of the DBSCAN algorithm outperforming other methods in processing effect. The experimental verification shows that the DBSCAN clustering algorithm can effectively screen the power grid data, thereby significantly improving the accuracy and reliability of the calculation result of the main grid's theoretical line loss.

A study of Optimal Reconfiguration in Distribution Power System using Initial Operating Point (초기 운전점 선정을 통한 배전계통 최적 재구성에 관한 연구)

  • Seo, Gyu-Seok;Kim, Jung-Nyun;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.451-456
    • /
    • 2007
  • This paper presents a problem that reconfigure distribution power system using branch exchange method. Optimal reconfiguration problem calculates line loss, voltage condition about system states of all situations that become different according to line On/off status, and search for optimum composition of these. However, result is difficult to be calculated fast. Because radiated operation condition of system is satisfied using many connection and sectionalize switches in the distribution power system. Therefore, in this paper, optimization method for reducing system total loss and satisfying operating condition of radial and constraints condition of voltage is proposed using the fastest branch exchange. And optimal solution at branch exchange algorithm can be wrong estimated to local optimal solution according to initial operating state. Considering this particular, an initial operating point algorithm is added and this paper showed that optimal solution arrives at global optimal solution.

Analysis of conducted noise on modeling methods for loss of contact during traction of high-speed rail vehicle (고속전철 주행시 이선현상 모델링 방법에 따른 전도성 노이즈 해석)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.72-75
    • /
    • 2008
  • The Electromagnetic Interference(EMI) in railway applications is largely due to doing the power conversion for traction and Auxiliary system on the Highspeed Electric Multiple Unit-400X(HEMU-400X). In order to research on EMI in railway applications, it were included how much the HEMU-400X generates it and it has an effect on the equipments of electric system which resulted from Power Line Disturbance (PLD) phenomenon by the loss of contact during its running. In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated. The analysis of the loss of contact based on Power Simulator program software is performed to develop power line disturbance model suitable for high speed operation. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system.

  • PDF

Optimal Efficiency Control of Induction Generators in Wind Energy Conversion Systems using Support Vector Regression

  • Lee, Dong-Choon;Abo-Khalil, Ahmed. G.
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.345-353
    • /
    • 2008
  • In this paper, a novel loss minimization of an induction generator in wind energy generation systems is presented. The proposed algorithm is based on the flux level reduction, for which the generator d-axis current reference is estimated using support vector regression (SVR). Wind speed is employed as an input of the SVR and the samples of the generator d-axis current reference are used as output to train the SVR algorithm off-line. Data samples for wind speed and d-axis current are collected for the training process, which plots a relation of input and output. The predicted off-line function and the instantaneous wind speed are then used to determine the d-axis current reference. It is shown that the effect of loss minimization is more significant at low wind speed and the loss reduction is about to 40% at 4[m/s] wind speed. The validity of the proposed scheme has been verified by experimental results.

A Study on the Reflection Type Analog Phase Shifter using Varactor and Branch Coupler (가변 캐패시터와 Branch Coupler를 이용한 반사형 아날로그 위상 변위기 연구)

  • 유강희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3A
    • /
    • pp.311-317
    • /
    • 2004
  • A low loss reflection type analog phase shifter which is realized with two varactors and branch coupler. is described. A new design technique for the large phase shift is applied using short stub microstripe lines. This paper presented the realization of design and experimental results. Through the experiment using the duroid microstrip line and varactors, the phase of 2.26GHz signal is controlled to the DC voltage with the phase shift range of 170$^{\circ}$. The achieved insertion loss of less than 3㏈ and the return loss of mote than 12㏈ are achieved over all phase states.

Analysis of Power Line Characteristics as High Speed Communication Channel (고속 채널로써 전력선 특성 분석)

  • Park, Chong-Yeun;Jo, Ho-Chan;Lee, Hyeuk-Sun
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.207-211
    • /
    • 2001
  • For the power line communication, we studied its characteristic impedance, noise characteristics, loss characteristics and the coupling circuit between the communication MODEM and power lines. As the results of the experiments, we concluded that the power line impedance in a house varied in the wide range because the electric systems generate the current and voltage hamornic noises.

  • PDF

Compact Open-stub Band-pass Filter with Narrow Bandwidth Using Impedance Mismatching of the Transmission- line (전송선로의 임피던스 부정합을 이용한 협대역 개방형 소형 스터브 대역통과 여파기)

  • Yoon, Ki-Cheol;Oh, Seung-Yeon;Oh, Kyoung-Min;Lee, Hyun-Wook;Hong, Tae-Ui;Lee, Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.6
    • /
    • pp.38-47
    • /
    • 2008
  • In this paper, the narrow band-pass filter with compact-size using the ${\lambda}g/2$ open stubs is proposed. The filter size is reduced by realization of transmission line at second harmonics and at the same time the power can be transferred to the output by using the fundamental wave generated in the resonator and the transmission line in which the impedance mismatch technique is adopted. Thus, the proposed filter can be reduced to half-length of horizontal transmission line than the conventional one. The experimental results show that insertion loss is 1.58 dB and return loss is 9.86 dB, and the fractional bandwidth is 10 % at the center frequency of 5.8 GHz. The filter size is $10.34{\times}18.56\;mm2$.

  • PDF

A Low Loss and Short-wavelength Transmission Line Employing Inverted Periodically Arrayed Capacitive Devices and Its Application to Miniaturized Passive Components on MMIC (저손실·단파장 특성을 가지는 반전된 형태의 주기적 용량성 선로구조와 MMIC상의 초소형 수동소자 개발에의 응용)

  • Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.149-156
    • /
    • 2012
  • In this study, we propose a novel transmission line employing inverted PACD (Periodically Arrayed Capacitive Devices) for application to a development of miniaturized passive components on MMIC. The novel microstrip line employing Inverted PACD structure showed a loss much lower than conventional microstrip line. Using the inverted PACD structure, we fabricated a miniaturized impedance transformer on MMIC. the size of the impedance transformer was 0.012 $mm^2$, which is only 1.7% of conventional one. The impedance transformer showed good RF performances in a frequency range of 2.25~6.5 GHz.