• Title/Summary/Keyword: Line capacity

Search Result 1,075, Processing Time 0.026 seconds

Study and Survey of Operating Efficiency with Cool Storage System (빙축열냉방시스템의 운전효율에 관한 조사연구)

  • 손학식;심창호;김강현;김재철
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study is to maintain high efficiency and reasonable use of cool thermal storage systems operated in the domestic building sector. As the result of efficiency test from the five types of operated cool storage systems on the condition that COP ranges are 2.6 to 3.4 during the day time and 2.1 to 3.0 during the night time and it decreased by more than 30% of rated COP given 3.8 to 3.0. The Analysis of cool storage rate shows that only 3 (21.4%) systems out of 15 buildings hold to over 40% capacity for its total capacity. To prevent the decrease in operating efficiency, it should correct the malfunction of 3-way valve and expansion valve and the mistake of control values for schedule program and increase cooling tower capacity. In order to improve piping line, it needs bypass brine line off refrigerator, separation of chilled water line with Ice Slurry system at day and night time and speed control of chilled and warm water pumps. This study does require the more studies on improving difficulty of increasing cooling load with Ice on Coil system, waterproofing with Ice Ball system, COP drop during the night time with Ice Lens, low operating temperature during the day time with Ice Slurry and increasing of Power loss due to hot gas de-icing with Ice Harvest in the future.

Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model (축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom;Kwon, Sin-Won;Gil, Kyung-Suk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

Integrated Storage System For Automobile Production Line (자동차 생산라인을 위한 통합창고 시스템)

  • Kim, Duksu;Seo, Yoonho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.2
    • /
    • pp.1-8
    • /
    • 2014
  • The automobile manufacture is a typical integrated assembly production that the numerous parts are committed sequentially to the assembly line. In this type of automobile manufacture, WBS (white body storage) and PBS (paint body storage) are operated to adjust the production sequence and to buffer. Starvation (impossibility of production owing to the insufficient supply) or blocking (impossibility of production owing to the over capacity) could occur in some chance, hence, both storages (WBS, PBS) are integrated as a prevention. This system is called integrated storage. In this paper, we suggest the simulation model of 'WBS-PBS integrated storage' and methodology of operation considering both 'Color grouping' and 'Option leveling.'

Selection of The Optimal Line using 3D GIS (3차원 지형정보를 이용한 최적노선 선정)

  • Han, Byoung-Cheol;Choi, Hyun;Kang, Sang-Yun;Kang, In-Joon
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.367-374
    • /
    • 2004
  • Roads which were not considered conditions such as capacity of the traffic have made seriously traffic problems and complex road lines. Construction of new roads have to make efficiently for solving the above problems and gain benefits. Simulation using 3D-GIS help find a matter of the design and do understanding users who work In the practical businesses. This study is showed selection of the optimal road line based on 3D-GIS through the traffic modeling.

  • PDF

An Overtaking-station-selection Algorism Based on Realtime Simulation for the Optimization of Mixed Operation of Express and Regular Trains of Urban Transit (도시철도의 완.급행 혼합 운전계획 최적화를 위한 실시간 시뮬레이션 기반 대피역 선정 알고리즘)

  • Seon, Hyeon-Kyoo;Ryu, Sang-Hwan;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.490-497
    • /
    • 2011
  • When operating Express and Standard trains, which run with two different scheduled time, in a single line with limited number of side tracks for overtaking standard trains, it is required to have various modeling methodologies and simulations in order to calculate an optimum headway to maximize the capacity of the line with the best scheduled time. Especially it is inevitable that following trains have to slow down or stop in the middle of their operations due to the preceding trains, in case it is inappropriate controlled about either in which station an overtaking should be taken or how long it should be. This study is to analyze TPS data which have been produced with a simulation program which the team has invented to optimize Express and Standard mixed traffic plan and to introduce an algorism which shows detected conflict data, calculates appropriate dwell time after getting overtaken and helps to decide stations for overtaking.

  • PDF

Response Analysis of Ground Vibration for Cutting and Embankment Transition Zone Structure (절성토 접속구조별 지반진동 응답특성)

  • Lee, Il-Wha;Yun, Won-Min;Choi, Won-Il;Hwang, In-Hwan;Hwang, Sung-Wook
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3195-3200
    • /
    • 2011
  • The vibration resulting from railway operation is transmitted through the track and line structure, ground movements to adjacent buildings. As these vibration is growing, there is occurred exaggerated forces and displacements of the track and line structure and it is causing the differential settlement. It is difficult to clarify the dynamic response characteristics of trackbed because of various environmental conditions. However, track irregularity be affected by ununiformed bearing capacity and its dynamic response, study for dynamic response characteristics is required to investigate the cause of track irregularity and countermeasure. This study was intended to evaluate the numerical analysis which exam the response analysis characteristic of ground vibration by shape of cutting and embankment transition zone. The original method of analysis were have to examine variables such as directions, angles, drain conditions, linear conditions. However, In the analysis there were to consider the effect of moving loads according to directions of cutting and embankment transition zone.

  • PDF

The Disagreement of Discourse and Power Through the Experiences of Nursing for Caring of Long-term Hospitalized Patients (장기 입원환자 간호 갈등경험을 통해 본 담론 대립과 권력)

  • Kim, Hae Ok
    • Korean Journal of Adult Nursing
    • /
    • v.19 no.3
    • /
    • pp.495-507
    • /
    • 2007
  • Purpose: This critical ethnography was performed to explore the experiences of nurses who are working with patients in an industrial disaster hospital. During the research process, I focused on the experiences of conflict in caring patients. Methods: Data for the study came from 13 informants with their corresponding patients through interview and observation from March 2002 to February 2004. The data was examined line by line; then compared and contrasted based on a critical discourse analysis. Results: Nurses' conflicts came from discrepancies of the world views from that of the patients. Such conflicts arose because of various issues as follows: Worker as an individual vs patients, nurse as young women vs the medical profession, hospital as an extended home vs health care setting, and hospitalization as a means to enhance work capacity vs a means of treatment. Conclusion: We need more study on the development of adaptive strategy for the nurses to overcome conflicts during their nursing career. Developing a nurses' and patient role intervention program is needed.

  • PDF

Voltage Estimation Method for Distribution Line with Irregularly Dispersed Load (부하가 불규칙하게 분포된 배전선로의 전압추정 방법)

  • Park, Sanghyeon;Lim, Seongil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.491-497
    • /
    • 2018
  • Most of the applications for distribution system operation highly rely on the voltage and current managements from the field devices. Voltage from the remote controlled switch contains unacceptably large measurement error due to the nonlinear characteristics of the bushing potential transformer. This paper proposes a new voltage magnitude estimation method by calculating voltage drop using current measurement, line impedance and loads deployment data. Contract demand power and pole transformer capacity managed by NDIS are used as a key element to improve accuracy of the proposed method. Various case studies using Matlab simulation have been performed to verify feasibility of the propose voltage estimation method.

Survey of Evolutionary Algorithms in Advanced Planning and Scheduling

  • Gen, Mitsuo;Zhang, Wenqiang;Lin, Lin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.35 no.1
    • /
    • pp.15-39
    • /
    • 2009
  • Advanced planning and scheduling (APS) refers to a manufacturing management process by which raw materials and production capacity are optimally allocated to meet demand. APS is especially well-suited to environments where simpler planning methods cannot adequately address complex trade-offs between competing priorities. However, most scheduling problems of APS in the real world face both inevitable constraints such as due date, capability, transportation cost, set up cost and available resources. In this survey paper, we address three crucial issues in APS, including basic scheduling model, job-shop scheduling (JSP), assembly line balancing (ALB) model, and integrated scheduling models for manufacturing and logistics. Several evolutionary algorithms which adapt to the problems are surveyed and proposed; some test instances based on the practical problems demonstrate the effectiveness and efficiency of evolutionary approaches.

Developing an On-line Handwritten Word Recognition System Using Stroke Information and Post-processing Techniques (영문 대문자의 획 정보와 후처리를 이용한 온라인 필기 단어 인식기 구현)

  • 윤인구;김우생
    • Proceedings of the IEEK Conference
    • /
    • 2000.06c
    • /
    • pp.19-22
    • /
    • 2000
  • This paper presents new on-line handwritten algorithm for continuous alphabet uppercase characters. The algorithm is based on the idea that alphabet uppercase character consists of at most 4 strokes. It tries to determine the maximum output for a recognition result among outputs of four recognizers which have the capacity to discriminate the character using from 1 through 4 stroke information. The recognition module has 4 neural network based recognizers, which can recognize from 1 through 4 stroke character. We also use specialized post-processing techniques for improving the recognition performance. Trained on 440 input data and choosing 390 uppercase words for a recognition test we reached a 92% recognition rate.

  • PDF