• Title/Summary/Keyword: Line Defect

Search Result 363, Processing Time 0.039 seconds

A Study on the Sensitivities Characteristics in a PD and a HFPD (PD 측정과 HFPD의 감도특성에 관한 연구)

  • Lim, Jang-Seob;Kim, Duck-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.29-32
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires on-line & on-site diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and PD/HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

Analysis of Insulation Aging in Operating High Voltage Motors (운전중인 고압전동기에서 절연열화 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

A Case Study on Malfunction of OCGR and Inaccuracy of Watt-hour Meter in Distributed Generation System (분산형 발전고객의 OCGR오동작 및 과부족 계량에 대한 사례연구)

  • Shin, Dong-Yeol;Park, Yong-Woo;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1349-1355
    • /
    • 2008
  • The paper shows the analysis of operating conflict of OCGR trip events and metering errors in the photovoltaic generation, wind generation distributed generation customers with no defect of the distributed generation facilities, which are connected to 22.9kV distribution lines. To analyze problems with metering errors and OCGR fault event, a power quality analyzer and PSIM program were used to test the field and to simulate in Sun-Cheon photovoltaic generation and Seo-Cheon photovoltaic generation customers. With the trial distribution line, the result of analysis was verified to prove with the same situation of the actual field. This paper suggests short term and long term countermeasures of OCGR fault events, analysis of over and shortage of metering errors in distributed generation customers.

Rare Cleft of the Nose (코에 국한된 희귀 안면 갈림)

  • Lee, Jung Ho;Song, Jin Kyung;Byeon, Jun Hee
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.667-670
    • /
    • 2005
  • Congenital facial cleft is a rare entity and appears along by the line of different processes of the facial development. An isolated cleft of the nose has been reported not often in the literature. We treated a patient with an isolated nasal cleft associated with undefined cranial anomaly. On 3D CT scan was seen a bony cleft traversing the pyriform aperture lateral to the anterior nasal spine. The nasal septum and frontal process of the maxilla were intact. There also was found bilateral bony defects in the frontal bone and bilateral frontal boss. The nasal cleft and frontal defect and boss were corrected by two stages: anterior two-third of the cranial vault with bilateral frontal boss was remodeled at the age of two years and the nasal cleft was repaired with a local rotation flap at age 3.

Reconstructive Strategies for Chronic Achilles Tendon Rupture (만성 아킬레스건 파열의 수술 전략)

  • Cho, Byung-Ki;Ahn, Byung-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.25 no.2
    • /
    • pp.80-88
    • /
    • 2021
  • Chronic Achilles tendon rupture is likely to result in functional impairment in gait and sports activity. The presence of a large defect secondary to retraction of the tendon ends, atrophy of the calf muscles, and vulnerable vascularity of the soft tissue envelope make it a challenging problem to treat. Surgical reconstruction aims to restore the length and tension of the gastrocnemius-soleus complex. Various surgical treatment options have been described, depending on several factors, including residual gap size after scar tissue removal, remaining tissue quality, and vascularity. Despite good results being reported, there is a lack of high-level, evidence-based clinical guidelines available to select the first-line surgical procedure. This paper overviews the current available surgical options for patients with chronic Achilles tendon rupture.

Development of robot calibration method based on 3D laser scanning system for Off-Line Programming (오프라인 프로그래밍을 위한 3차원 레이저 스캐닝 시스템 기반의 로봇 캘리브레이션 방법 개발)

  • Kim, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.16-22
    • /
    • 2019
  • Off-line programming and robot calibration through simulation are essential when setting up a robot in a robot automation production line. In this study, we developed a new robot calibration method to match the CAD data of the production line with the measurement data on the site using 3D scanner. The proposed method calibrates the robot using 3D point cloud data through Iterative Closest Point algorithm. Registration is performed in three steps. First, vertices connected by three planes are extracted from CAD data as feature points for registration. Three planes are reconstructed from the scan point data located around the extracted feature points to generate corresponding feature points. Finally, the transformation matrix is calculated by minimizing the distance between the feature points extracted through the ICP algorithm. As a result of applying the software to the automobile welding robot installation, the proposed method can calibrate the required accuracy to within 1.5mm and effectively shorten the set-up time, which took 5 hours per robot unit, to within 40 minutes. By using the developed system, it is possible to shorten the OLP working time of the car body assembly line, shorten the precision teaching time of the robot, improve the quality of the produced product and minimize the defect rate.

Treatment of cemental tear associated with periapical lesion using regenerative surgery; A case report (재생술식을 이용한 치근단 병소를 동반한 백악질 열리의 치료)

  • Kang, Hyo-Jin;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.5
    • /
    • pp.365-373
    • /
    • 2016
  • Purpose: Cemental tear is a specific type of root surface fracture characterized by a complete separation of a cemental fragment along the cementodentinal junction or a partial split within the cementum along an incremental line. It is suggested to be a factor for periodontal or periapical tissue destruction. The aim of this study is to present a diagnosis and treatment of cemental tear associated with periapical lesion with root canal treatment and regenerative periodontal surgery. Treatments: A 60-year-old male who had a history of sports trauma on the mandibular right central incisor about 10 years ago presented with apical cemental tear. Clinical examination showed a slightly dark yellowish discoloration and sinus tract that was located on the apical labial mucosa. The mobility and percussion were also assessed on the diseased tooth and recorded as $Miller^{\circ}{\phi}s$ Class II and tenderness to percussion. The probing depth was within the normal limit (<3 mm). Radiographic examination revealed a radiolucent lesion at the apical area and extended to distal aspect of the tooth along the fragment of cemental tear. After root canal treatment, periapical surgery was performed. The bony defect was exposed and then the detached root fragment was removed. Apical root resection and retrograde filling with Mineral Trioxide Aggregate (MTA) were accomplished and the bony defect was filled with deproteinized bovine bone mineral (DBBM) and covered with biodegradable collagen membrane. Results: After 9-month follow-up, healing of the mandibular right central incisor was uneventful and no swelling, purulence or pain was revealed in the associated area. Probing pocket depth was favorably stable, and the tooth mobility was decreased to the Miller's Class I. Conclusions: Apical cemental tear associated periapical lesion could be successfully treated with removal of the detached cementum in combination with apical surgery and GTR procedure.

  • PDF

The study on the possibility of performance analysis for the compressive member using the numerical method (수치해석법을 활용한 압축부재 성능 해석의 가능성에 대한 연구)

  • Kim, Gwang-Chul
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.1
    • /
    • pp.26-39
    • /
    • 2010
  • This is a leading study to replace the structural analysis methodology on the specific traditional joint by a numerical analysis. Tests were carried out to test the compressive methodologies with the numerical results. The Japanese larch was used as a sample. The Orthotropic property of wood was specifically considered for the finite element numerical analysis. Linear numerical analysis and non-linear numerical analysis for the BEAM element and the two SOLID elements of ANSYS were used to analyze the compressive performance. In addition, more finely divided elements were used to raise the accuracy of the numerical result. Finally, the statistically significant differences were tested between that of the analytical and numerical results. It could be concluded that the SOLID 64 element shows the most optimum result when the non-linear analysis with the more finely divided element was used. However, finely dividing of the element is a considerable time consuming process, and it is quite difficult to raise the accuracy of the non-linear numerical analysis. Therefore, if considering the vertical displacement to be of the only interest, the BEAM element is more efficient than the SOLID element because the BEAM element is reflected as a simple line, which is less time consuming and difficult in dividing the elements. But, the BEAM element cannot accurately model the knot as a strength defect factor which is an important property in the orthotropic property of wood. Therefore, the SOLID element should be used to model the strength defect factor, knot, as it can be efficiently applied on the structural size flexure member which could be more strongly effected by the knot. In addition, it is useful at times when the failure types of members are to be more closely investigated, as the SOLID element is able to examine the local stress distribution of the member. The conclusion drawn by this study is of the good concordance between analytical results and numerical results of compressive wood members, but how orthotropic properties should only be considered. The numerical analysis on the specific Korean traditional joints will be based on the current study results.

  • PDF

Reconstruction of Trochanteric Pressure Sores using Perforator-based Flap from the Ascending Branch of Lateral Circumflex Femoral Artery (외측대퇴회선동맥 상행가지의 천공지피판을 이용한 대전자부 욕창의 재건)

  • Kim, Jun-Hyung;Eo, Su-Rak;Cho, Sang-Hun
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.595-599
    • /
    • 2010
  • Purpose: Trochanteric pressure sores management has been improved through the development of musculocutaneous flaps. But it has many drawbacks such as donor site morbidity and functional muscle sacrifice. With the introduction of perforator flap, it is possible to use in every location where musculocutaneous perforators are present. We have reconstructed trochanteric pressure sores using perforator-based flaps from the ascending branch of lateral circumflex femoral artery. Methods: Between May of 2006 and April of 2008, we performed six cases of perforator-based flap from the ascending branch of lateral circumflex femoral artery for the coverage of trochanteric pressure sores. For identifying perforators, a line was drawn from the anterior superior iliac spine to the superolateral border of the patella as the vertical axis, from the pubis to the trochanteric prominence as the horizontal axis. In the lateral aspect of the intersection of these two axes, various flap were designed according to its defects. The flap was raised in the subcutaneous plane above the fascia and the pedicle was traced by doppler and identified. The pedicle was meticulously dissected not to injure the periadventitial tissues and transposed to the defect. The donor site was closed primarily. Results: The mean age of patients was 56.2 years. Four male and two female patients were studied. Five patients were paraplegic. The mean defect size was $6{\times}4\;cm$. The largest flap dimension was $14{\times}7\;cm$. Donor sites were closed primarily without any complications. All flaps survived completely without necrosis, hematoma or infection. There were no recurrence during the follow-up period. Conclusion: Trochanteric pressure sores using perforator-based flap from the ascending branch of lateral circumflex femoral artery can be performed safely and it would be a reliable option for coverage of trochanteric pressure sores with minimal donor site morbidity.

The multifunctional RNA-binding protein hnRNPK is critical for the proliferation and differentiation of myoblasts

  • Xu, Yongjie;Li, Rui;Zhang, Kaili;Wu, Wei;Wang, Suying;Zhang, Pengpeng;Xu, Haixia
    • BMB Reports
    • /
    • v.51 no.7
    • /
    • pp.350-355
    • /
    • 2018
  • HnRNPK is a multifunctional protein that participates in chromatin remodeling, transcription, RNA splicing, mRNA stability and translation. Here, we uncovered the function of hnRNPK in regulating the proliferation and differentiation of myoblasts. hnRNPK was mutated in the C2C12 myoblast cell line using the CRISPR/Cas9 system. A decreased proliferation rate was observed in hnRNPK-mutated cells, suggesting an impaired proliferation phenotype. Furthermore, increased G2/M phase, decreased S phase and increased sub-G1 phase cells were detected in the hnRNPK-mutated cell lines. The expression analysis of key cell cycle regulators indicated mRNA of Cyclin A2 was significantly increased in the mutant myoblasts compared to the control cells, while Cyclin B1, Cdc25b and Cdc25c were decreased sharply. In addition to the myoblast proliferation defect, the mutant cells exhibited defect in myotube formation. The myotube formation marker, myosin heavy chain (MHC), was decreased sharply in hnRNPK-mutated cells compared to control myoblasts during differentiation. The deficiency in hnRNPK also resulted in the repression of Myog expression, a key myogenic regulator during differentiation. Together, our data demonstrate that hnRNPK is required for myoblast proliferation and differentiation and may be an essential regulator of myoblast function.