• Title/Summary/Keyword: Line Defect

Search Result 363, Processing Time 0.041 seconds

On the LACBED Method to Determine the Nature of the Dislocation Defect in Crystalline Materials (결정체내의 전위 결함 형태를 결정하는 LACBED 방법에 관한 고찰)

  • Kim, Hwang-Su
    • Applied Microscopy
    • /
    • v.35 no.4
    • /
    • pp.64-73
    • /
    • 2005
  • In this paper we discussed in details how to determine the nature of dislocations in a crystal such as a Burgers vector, the line vector of dislocation and the associated slip plane, using LACBED and usual imaging techniques. These techniques basically involve the application of Cherns and Prestone s rules, the simulations of LACBED patterns with a certain form of the dynamical diffraction theory. The theoretical aspects including necessary approximations for calculations also were in details discussed. As a test specimen for experiments, the foils of a pure aluminum, containing many dislocations with appropriate density for LACBED experiments, were used..

A Study on On-Line Quality Monitoring Using Arc Light in Gas Metal Arc Welding (GMAW에서 아크 빛을 이용한 실시간 용접품질 모니터링에 관한 연구)

  • 조택동;양상민
    • Journal of Welding and Joining
    • /
    • v.18 no.4
    • /
    • pp.82-86
    • /
    • 2000
  • Gas metal arc welding(GMAW) is regarded as one of the best candidate for welding automation in industrial joining application. It is important to monitor the weld quality for the high performance weld automation. In GMAW, weld quality is closely related to arc stability especially. In this paper, arc light signal is measured and spectrum analyzed to the detect the variation of the weld quality. The FFT of the signal showed that the amplitude variance of FFT power spectrum was very large in poor weld process such as the decrease of weld bead width and height. The results show that it is possible to detect the weld defect position in weld process.

  • PDF

Diaphragmatic deformity in a cat mimicking a cardiac mass

  • Choi, Ran;Lee, Seung-Gon;Moon, Hyeong-Sun;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.2
    • /
    • pp.209-213
    • /
    • 2008
  • A four-month-old intact femlae Abyssinian cat was present for routine health evaluation, because her littermate was recently died of ventricular septal defect. Diagnostic imaging studies showed a large caudal paracardiac mass in thoracic radiography and homogenous mass adjacent to heart in the echocardiography. Further echographic study revealed that the mass was liver and the diaphragmatic line was intact. The positive contrast celiogram revealed that no extravasation of the contrast media across the diaphragm and the prolapse of diaphragm into the pleural cavity. Based on our diagnostic imaging studies, the case was diagnosed as diaphragmatic deformity in a cat mimicking a cardiac mass.

Defect Detection of 22.9kV Distribution Line based on the PD Detection (부분방전 검출을 이용한 22.9kV 배전케이블 실선로 결함 검출)

  • Lee, Jeon-Seon;Kim, Jung-Yoon;Kim, Seok-Jong;Lee, Dong-Geun;Seo, Kyung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.53-55
    • /
    • 2004
  • 부분방전 검출을 이용한 XLPE 케이블 진단은 중간 및 종단 접속재의 계면에 존재하는 결합을 검출할 수 있는 가장 효과적인 방법으로 제시되고 있지만 현장의 큰 노이즈로 인하여 신뢰성 있는 진단이 쉽지 않다. 하지만 국내에서 많은 연구가 이루어진 송전케이블 진단 기술을 바탕으로 배전케이블 진단에 적용하여 종단접속부에서 발생된 부분방전을 성공적으로 검출하였고 해체 조사를 통하여 결함을 검출하였다. 본 논문은 참고문헌[1]에 발표한 논문에 연결되는 논문으로 전편은 2004년 2월 부분방전 검출사례를 보고한 논문이고 본 논문에서는 8월 계획정전을 통하여 문제된 접속함을 교체한 후 해체조사를 통하여 결함을 검출한 사례보고이다.

  • PDF

An investigation on the metal depression of aluminum (알루미늄 Metal Depression에 관한 연구)

  • Kim, Tae-Gun;Kim, Nam-Hoon;Kim, Sang-Yong;Lee, Woo-Sun;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.86-87
    • /
    • 2005
  • Aluminum(Al) sputtering is best known method to form Al film for the Si wafer in the process of 180nm and above. In the Al metal line process, one of the frequently founded and well-known defect was metal depression. In this paper, several experiments were performed such as temperature, Ar gas flow rate, thickness change in other to reduce the metal depression and find the origination of metal depression. Through experiments, it is found that metal depression was significantly related to the temperature. And the Ar gas flow rate did not influence to the creation of depression. The off status ESC also showed stable metal film without depression by same mechanism of temperature decrease. Also, thickness is strongly influence to the metal depression.

  • PDF

Development of VLSI Process Simulator (반도체 공정 시뮬레이터 개발에 관한 연구)

  • 이경일;공성원;윤상호;이제희;원태영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.40-45
    • /
    • 1994
  • The TCAD(Technology Computer Aided Design) software tool is a popular name to be able to simulate the semiconductor process and device circuit. We have developed a two-dimensional TCAD software tool included an editor, parser, each process unit, and 2D, 3D graphic routine that is Integrated Environment. The initial grid for numerical analysis is automatically generated with the geometric series that use the user default(given) line and position separated with grid interval and the nodes corresponding to each mesh point stoic the all the possible attribute. Also, we made a data structure called PIF for input or output. Methods of ion implantation in this paper arc Monte Carlo, Gaussian Pearson and Dual-Pearson. Analytical model such as Gaussian, Pearson and Dual-Pearson were considered the multilayer structure and two-dimensional tilted implantation. We simuttaneously calculated the continuity equation of impurity and point defect in diffusion simulation. Oxidation process was simulated by analytical ERFC(Complementary Error Function) model for local oxidation.

PS-b-PDMS와 Amorphous Carbon Layer를 이용하여 Aspect-ratio와 Line-edge 개선에 대한 연구

  • O, Ji-Su;Seong, Da-In;O, Jong-Sik;Yeom, Won-Gyun;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.142-142
    • /
    • 2017
  • High Flory-Huggins interaction parameter (${\chi}$)를 가지는 polystyrene-block-dimethylsiloxane (PS-b-PDMS)는 초미세 패턴 제작과 우수한 defect density, 우수한 edge roughness 특성으로 향상된 패턴을 제공한다는 점에서 반도체 분야에서 많은 연구가 되고 있다. 하지만, PS와 PDMS 사이에 존재하는 큰 surface tension의 차이로 인해 PDMS는 PS와 air 사이에서 segregate되기 때문에 수직배향에 불리하여 high aspect ratio (HAR)을 가지는 cylinder, lamellar 패턴 제작에 있어 큰 어려움을 가진다. 본 연구에서는 이러한 문제를 해결하기 위해, PS-b-PDMS BCP 패턴과 하부 실리콘 기판 사이에 amorphous carbon layer (ACL)를 삽입하여 효과적으로 pattern transfer하는 공정을 연구하였다. 플라즈마를 이용하여 무한대에 가까운 etch selectivity를 가지는 식각 공정을 개발함으로써 낮은 aspect ratio를 가지는 PS-b-PDMS BCP 패턴의 한계점을 극복하였다. Large-x value를 가지는 BCPs를 이용하여도 매우 높은 aspect ratio를 가지면서 동시에 pattern quality를 향상시킬 수 있는 plasma process를 제시하였다.

  • PDF

Measurement of Defects on the Wall by use of the Inclination Angle of Laser Slit Beam and Position Tracking Algorithm of Camera (레이저 슬릿빔의 경사각과 카메라 자세 추정 알고리즘을 이용한 벽면 결함 측정)

  • 김영환;송상호;윤지섭;강이석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.339-339
    • /
    • 2000
  • In this parer, a method of measuring the size of defects on the wall and restructing the defect image of 3-dimension is developed based on the tracking algorithm of a camera position which uses the inclination angle of line slit beam for overcoming the difficulty of the corresponding problem identifying the image point in the both image. In the experiments, an algorithm for estimating the horizontal angle of CCD camera is presented and validated by applying it to the measurement of area and length under the variations of both the distance and the angle of CCD camera. And its performance is compared to that of the rotating and mapping method of image which has the Euclidian distance.

  • PDF

Oral and Maxillofacial Surgery Planning using 3D Clinical Model (3D 모델을 이용한 구강악면안면 외상환자수술 계획수립)

  • Kim, N.K.;Lee, D.H.;Kim, J.H.;Min, B.G.;Kim, Y.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.277-278
    • /
    • 1998
  • CT/MRI images were frequently taken to evaluate the anatomic structure and disease status, and to plan the treatment modality for oral and maxillofacial surgery. However, surgeons have many difficulties in reading and understanding 2D images without long time experiences. This study presents the method of 3D reconstruction with fine CT slices and its clinical application. We applied this method a clinical patient with oral and maxillofacial trauma and produced 3D reconstructed model which shows the fracture line in panfacial area and bone defect.

  • PDF

A study on fabrication of a micro patterned LGP (미세 패턴 응용 도광판 제작에 관한 연구)

  • Yoo Y.E.;Kim T.H.;Kim S.G.;Seo Y.H.;Je T.J.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.533-534
    • /
    • 2006
  • Micro pyramid pattern and its array are designed to enhance the brightness and its uniformity of LGP which is one of key parts in LCD. The designed micro pyramid patterns are fabricated on a Si-wafer first through MEMS process and then a Ni-stamper is electro-plated from the Si pattern master. Adopting the fabricated Ni-stamper, LGPs are injection molded at different mold temperatures and the fidelity of the pattern replication is estimated for each molding conditions and pattern locations. The replicated patterns are found to have some defect such as local short shot or micro weld line which are believed to have negative effect on the performance of the LGP.

  • PDF