• 제목/요약/키워드: Limit of determination

검색결과 1,160건 처리시간 0.022초

근관치료의 근관장 측정에 관한 연구: 근관치료학 전공 교수 설문 (A survey on working length determination of endodontic treatment)

  • 안혜라;서민석
    • 대한치과의사협회지
    • /
    • 제55권1호
    • /
    • pp.42-52
    • /
    • 2017
  • The purpose of this study is to evaluate the preferred method of root canal length determination and the apical limit for canal instrumentation among endodontic teachers of dental school. A questionnaire on the preferred method of root canal length determination and the apical limit for canal instrumentation was designed and distributed to endodontic teachers of various dental schools. The response rate was 90%. The most preferred method of root canal length determination was Electronic apex locator (EAL)(89%). The most favoured apical limit for canal instrumentation was 0.5 to 1.0 mm short of the radiographic apex(78%). The most preferred method of using EAL was that the working length is taken at 'APEX' mark and then distracted 0.5mm from that length.(41%). When there is no agreement between radiographic measurement and EAL measurement, 74% of respondents chose the length of EAL measurement. The majority of endodontic teachers from Korean dental schools preferred EAL to radiograph method in determining root canal length.

  • PDF

시간의존법에 의한 금속판재 성형한계변형률의 결정 (Determination of the Forming Limit Strain of Sheet Metals by the Time-dependent Method)

  • 김성곤;오태환;김진동;김형종
    • 소성∙가공
    • /
    • 제24권5호
    • /
    • pp.361-367
    • /
    • 2015
  • The forming limit diagram (FLD) is the most commonly used tool for evaluating of sheet metal formability in the manufacturing field as well as the finite element analysis (FEA)-based design process. Determination of the forming limits is considerably influenced by testing/measuring machines, techniques and conditions. These influences may cause a large scatter in FLD from laboratory to laboratory. Scatter is especially true when the ‘position-dependent method’, as is specified in most national and international standards, is used. In the current study a new ‘time-dependent method’ is proposed, which is to determine the forming limit strains more accurately and reasonably when producing a FLD from experimental data. This method is based on continual strain measurement during the test. The results are compared to those from the existing standardized methods.

손해배상액 산정에 관한 최근 10년간 판례의 동향 (상)(上) (The Trend of Precedents about Calculation of Damage Compensation for Last Decade)

  • 박영호
    • 의료법학
    • /
    • 제10권2호
    • /
    • pp.11-36
    • /
    • 2009
  • This thesis introduces the trends of korean courts' ruling on damages in medical malpractice cases for past 10 years. First of all, Korean courts' ruling have had a tendency to pay only non-economic damages for not taking the informed consent. If a doctor cannot get the informed consent from a patient, he compensate only non-economic damages for the infringement of self-determination rights of patient. It's enough for the plaintiff to prove the infringement of self-determination rights, if the plaintiff just want to get non-economic damages. The Korean Supreme court have ruled that if plaintiffs want to get economic damages for the infringement of self-determination rights or informed consent, plaintiffs must prove that the infringement of self-determination rights is the proximate cause of the economic damages of patient. There is another tendency for the Korean Supreme court to limit the damages in medical malpractice cases on the ground of patient's diseases' dangerousness or patient's idiosyncrasy. In the past courts often limit the damages only to 70~80% of total damages, but now a days courts mostly limit the damages to 20~30%. This thesis also introduce the Korean courts' trends about Valuing damages in personal injury actions awarded for gratuitously rendered nursing and medical care.

  • PDF

조건부 차이조사의 관리한계 결정: 다구찌 품질손실 개념의 응용 (Determination of Control Limits of Conditional Variance Investigation: Application of Taguchi's Quality Loss Concept)

  • 배후석;임채관
    • 품질경영학회지
    • /
    • 제49권4호
    • /
    • pp.467-482
    • /
    • 2021
  • Purpose: The main theme of this study is to determine the optimal control limit of conditional variance investigation by mathematical approach. According to the determination approach of control limit presented in this study, it is possible with only one parameter to calculate the control limit necessary for budgeting control system or standard costing system, in which the limit could not be set in advance, that's why it has the advantage of high practical application. Methods: This study followed the analytical methodology in terms of the decision model of information economics, Bayesian probability theory and Taguchi's quality loss function concept. Results: The function suggested by this study is as follows; ${\delta}{\leq}\frac{3}{2}(k+1)+\frac{2}{\frac{3}{2}(k+1)+\sqrt{\{\frac{3}{2}(k+1)\}^2}+4$ Conclusion: The results of this study will be able to contribute not only in practice of variance investigation requiring in the standard costing and budgeting system, but also in all fields dealing with variance investigation differences, for example, intangible services quality control that are difficult to specify tolerances (control limit) unlike tangible product, and internal information system audits where materiality standards cannot be specified unlike external accounting audits.

Determining Potassium Bromate in the Inhalable Aerosol Fraction in Workplace Air with Ion Chromatography

  • Kowalska, Joanna;Lis, Monika;Biesaga, Magdalena
    • Safety and Health at Work
    • /
    • 제12권2호
    • /
    • pp.209-216
    • /
    • 2021
  • Background: The article presents the results of studies performed in order to develop a new method of airborne potassium bromate(V) determination at workplaces. Methods: The method is based on a collection of the inhalable fraction of potassium bromate(V) using the IOM Sampler, then extraction of bromates with deionized water and chromatographic analysis of the obtained solution. The analysis was performed using ion chromatography with conductometric detection. The tests were performed on a Dionex IonPac®AS22 analytic column (250 × 4 mm, 6 ㎛) with AG22 precolumn (50 × 4 mm 11 ㎛). Results: The method provides for potassium bromate(V) determination within the concentration range of 0.043 ÷ 0.88 mg/m3 for an air sample of 0.72 m3 in volume, i.e., 0.1-2 times the exposure limit value as proposed in Poland. The method was validated in accordance with PN-EN 482. The obtained validation data are as follows: measuring range: 3.1-63.4 ㎍/mL, limit of detection (LOD) = 0.018 ㎍/mL and limit of quantification (LOQ) = 0.053 ㎍/mL. The developed method has been tested in the work environment, on laboratory employees having contact with potassium bromate(V). Conclusion: The analytical method allowed the determination of the inhalable fraction of airborne potassium bromate(V) at workplaces and can be used to assess occupational exposure.

자동화학 분석기 Toshiba 120 FR의 평가 (Evaluation of Autochemical Analyzer Toshiba 120 FR)

  • 박점기
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.98-109
    • /
    • 2004
  • The lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with another equipment was evaluated for the Toshiba-120FR chemistry autoanalyzer which was newly introduced at the Daejeon Veteran Hospital in Dec. 2003. Nineteen kinds of test for AST, ALT, ALP, LDH, GGT, TP, ALB, GLU, T-cho, T-bil, TG, UA, CAL, IP, AMY, HDL-C, LDL-C, Cre and BUN were performed to evaluate the lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with other equipment according to the NCCLS guidelines(EP5-A, EP6-P, EP9-A). The Toshiba-120FR autochemical analyzer showed good precision for all tested items. The data concerning the lower limit of detection, precision(total CV 0.47%~3.65%), setting method of target value, reportable range determination, recovery(93%~111%), linearity($R^2=0.997{\sim}0.999$), and comparison study(r=0.977~0.999) with other equipment was acceptable for all tested items. The results of evaluation for the Toshiba-120FR autochemical analyzer showed that this equipment could be used as an alternative to other equipment.

  • PDF

압력손실시험을 이용한 막 완결성 평가에서 초기압력 및 UCL 도출인자 민감도 분석 (Sensitivity Analysis of Initial Pressure and Upper Control Limit on the Pressure Decay Test for Membrane Integrity Evaluation)

  • 이주희;홍승관;허현철;이광제;최영준
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.793-800
    • /
    • 2008
  • Recently domestic drinking water industry has recognized membrane-based technology as a promising alternative for water treatment. To ensure successful application of membrane processes, the integrity of membrane systems should be maintained. According to US EPA guidance, the pressure decay test based on the bubble point theory is recommended to detect any membrane defection of which size is close to the smallest diameter of Cryptosporidium oocysts, $3{\mu}m$. Proper implementation of the pressure decay test is greatly affected by initial test pressure, and the interpretation of the test results is associated with upper control limit. This study is conducted to investigate various factors affecting determination of initial test prtessure and upper control limit, including membrane-based parameters such as pore shape correction factor, surface tension and contact angle, and system-based parameters, such as volumetric concentration factor and total volume of system. In this paper, three different hollow fibers were used to perform the pressure decay test. With identical initial test pressure applied, their pressure decay tendency were different from each other. This finding can be explained by the micro-structure disparity of those membranes which is verified by FESEM images of those membranes. More specifically, FESEM images revealed that three hollow fibers have asymmetry, deep finger, shallow finger pore shape, respectively. In addition, sensitivity analysis was conducted on five parameters mentioned above to elucidate their relation to determination of initial test pressure and upper control limit. In case of initial pressure calculation, the pore shape correction factor has the highest value of sensitivity. For upper control limit determination, system factors have greater impact compared to membrane-based parameters.

Evaluation of limit load analysis for pressure vessels - Part I: Linear and nonlinear methods

  • Chen, Xiaohui;Gao, Bingjun;Wang, Xingang
    • Steel and Composite Structures
    • /
    • 제22권6호
    • /
    • pp.1391-1415
    • /
    • 2016
  • Limit load of pressure bearing structures was reviewed in this article. By means of the finite element analysis, limit load of pressurized cylinder with nozzle was taken as an example. Stress classification method and Elastic-plastic finite element analysis combining with limit load determination methods were used to determine limit load of cylinder with nozzle. Comparison of limit load determined by different methods, the results indicated that limit load determined by linearization method was the smallest. Limit load determined by twice elastic slope criterion was the nearest than experimental results. Elastic-plastic finite element analysis had comparably computational precision, but required time consuming. And then the requirements of computer processing and storage capacity by power system became higher and higher. Most of criteria for limit load estimation included any human factors based on a certain substantive characteristics of experimental results. The reasonable criterion should be objective and operational.

Electrochemical Behavior of Norfloxacin and Its Determination at Poly(methyl red) Film Coated Glassy Carbon Electrode

  • Huang, Ke-Jing;Xu, Chun-Xuan;Xie, Wan-Zhen
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.988-992
    • /
    • 2008
  • A poly(methyl red) film-modified glassy carbon electrode (PMRE) was fabricated for determination of norfloxacin (NFX). The electrochemical behavior of NFX was investigated and a well-defined oxidation peak with high sensitivity was observed at the film electrode. PMRE greatly enhanced the oxidation peak current of NFX owing to the extraordinary properties of poly(methyl red) film. Based on this, a sensitive and simple voltammetric method was developed for measurement of NFX. A sensitive linear voltammetric response for NFX was obtained in the concentration range of $1\;{\times}\;10^{-6}\;-\;1\;{\times}\;10^{-4}$ mol/L and the detection limit was $1\;{\times}\;10^{-7}$ mol/L using linear sweep voltammetry (LSV). The proposed method possessed advantages such as low detection limit, fast response, low cost and simplicity. The practical application of this new analytical method was demonstrated with NFX pharmaceuticals.

Comparison of Extraction Procedures for the Determination of Capsaicinoids in Peppers

  • Jeon, Geonuk;Lee, Jun-Soo
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1515-1518
    • /
    • 2009
  • The objective of this study was to compare 3 extraction methods including, solid phase extraction (SPE), acetonitrile extraction, and methanol extraction, for their usefulness as extraction methods to determine capsaicinoids. The determination of capsaicinoids in the extracts was carried out on a reverse-phased high performance liquid chromatography (HPLC) using a fluorescence detector. Three extraction methods, i.e., SPE, acetonitrile extraction, and methanol extraction were compared for the quantification of capsaicinoids using raw peppers and pepper powder. The highest analytical values were observed using methanol extraction and the lowest values using SPE. Also, the analytical method validation parameters such as accuracy, precision, limit of detection, limit of quantitation, and specificity were calculated to ensure the method's validity. This method provides a fast and accurate approach for the determination of capsaicinoids in peppers.