• Title/Summary/Keyword: Limit of Detection

Search Result 2,421, Processing Time 0.044 seconds

Rapid and Efficient Detection of 16SrI Group Areca Palm Yellow Leaf Phytoplasma in China by Loop-Mediated Isothermal Amplification

  • Yu, Shao-shuai;Che, Hai-yan;Wang, Sheng-jie;Lin, Cai-li;Lin, Ming-xing;Song, Wei-wei;Tang, Qing-hua;Yan, Wei;Qin, Wei-quan
    • The Plant Pathology Journal
    • /
    • v.36 no.5
    • /
    • pp.459-467
    • /
    • 2020
  • Areca palm yellow leaf (AYL) disease caused by the 16SrI group phytoplasma is a serious threat to the development of the Areca palm industry in China. The 16S rRNA gene sequence was utilized to establish a rapid and efficient detection system efficient for the 16SrI-B subgroup AYL phytoplasma in China by loop-mediated isothermal amplification (LAMP). The results showed that two sets of LAMP detection primers, 16SrDNA-2 and 16SrDNA-3, were efficient for 16SrI-B subgroup AYL phytoplasma in China, with positive results appearing under reaction conditions of 64℃ for 40 min. The lowest detection limit for the two LAMP detection assays was the same at 200 ag/μl, namely approximately 53 copies/μl of the target fragments. Phytoplasma was detected in all AYL disease samples from Baoting, Tunchang, and Wanning counties in Hainan province using the two sets of LAMP primers 16SrDNA-2 and 16SrDNA-3, whereas no phytoplasma was detected in the negative control. The LAMP method established in this study with comparatively high sensitivity and stability, provides reliable results that could be visually detected, making it suitable for application and research in rapid diagnosis of AYL disease, detection of seedlings with the pathogen and breeding of disease-resistant Areca palm varieties.

Rapid Detection of Streptococcus mutans Using an Integrated Microfluidic System with Loop-Mediated Isothermal Amplification

  • Jingfu Wang;Jingyi Wang;Xin Chang;Jin Shang;Yuehui Wang;Qin Ma;Liangliang Shen
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.8
    • /
    • pp.1101-1110
    • /
    • 2023
  • Streptococcus mutans is the primary causative agent of caries, which is one of the most common human diseases. Thus, rapid and early detection of cariogenic bacteria is critical for its prevention. This study investigated the combination of loop-mediated isothermal amplification (LAMP) and microfluid technology to quantitatively detect S. mutans. A low-cost, rapid microfluidic chip using LAMP technology was developed to amplify and detect bacteria at 2.2-2.2 × 106 colony-forming units (CFU)/ml and its detection limits were compared to those of standard polymerase chain reaction. A visualization system was established to quantitatively determine the experimental results, and a functional relationship between the bacterial concentration and quantitative results was established. The detection limit of S. mutans using this microfluidic chip was 2.2 CFU/ml, which was lower than that of the standard approach. After quantification, the experimental results showed a good linear relationship with the concentration of S. mutans, thereby confirming the effectiveness and accuracy of the custom-made integrated LAMP microfluidic system for the detection of S. mutans. The microfluidic system described herein may represent a promising simple detection method for the specific and rapid testing of individuals at risk of caries.

Development of a Novel Multiple Cross-Linking Spiral Amplification for Rapid and Sensitive Detection of HPV16 DNA

  • Zhang, Donghong;Liu, Dongliang;Liu, Bing;Ma, Xiulan
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.4
    • /
    • pp.610-620
    • /
    • 2021
  • There has been increasing interest in the head and neck squamous cell carcinoma (HNSCC) that is caused by high-risk human papillomavirus (HR-HPV) and has posed a significant challenge to Otolaryngologists. A rapid, sensitive, and reliable method is required for the detection of HR-HPV in clinical specimens to prevent and treat HPV-induced diseases. In this study, a multiple cross-linking spiral amplification (MCLSA) assay was developed for the visual detection of HPV-16. In the MCLSA assay, samples were incubated under optimized conditions at 62℃ for 45 min, and after mixing with the SYBR Green I (SGI) dye, the positive amplicons showed bright green fluorescence while the negative amplicons exhibited no obvious change. The specificity test revealed that the developed MCLSA technique had high specificity and could effectively distinguish all five HPV-16 strains from other pathogenic microorganisms. In terms of analytical sensitivity, the limit of detection (LoD) of MCLSA assay was approximately 5.4 × 101 copies/tube, which was 10-fold more sensitive than loop-mediated isothermal amplification (LAMP) and RT-PCR. The detection results of laryngeal cancer specimens collected from 46 patients with suspected HPV infection in the Liaoning region demonstrated that the positive detection rates of MCLSA and hybridized capture 2 kit were 32.61% (15/46). The true positive rate of the MCLSA assay was higher than that of RT-PCR (100% vs. 93.33%) and LAMP (100% vs. 86.67%). Therefore, the MCLSA assay developed in the present study could be a potentially useful tool for the point-of-care (PoC) diagnosis of HR-HPV, especially in resource-limited countries.

Development of Chicken Immunoglobulin Y for Rapid Detection of Cronobacter muytjensii in Infant Formula Powder

  • Kim, Yesol;Shukla, Shruti;Ahmed, Maruf;Son, Seokmin;Kim, Myunghee;Oh, Sejong
    • Food Science of Animal Resources
    • /
    • v.32 no.6
    • /
    • pp.706-712
    • /
    • 2012
  • The present study was aimed to produce a chicken polyclonal antibody against Cronobacter muytjensii and to develop an immunoassay for its detection. Purification of anti-C. muytjensii IgY from egg yolk was accomplished using various methods such as water dilution and salt precipitation. As a result, sodium dodecyl sulfate-polyacrylamide gel electrophoresis produced two bands around 30 and 66 kDa, corresponding to a light and a heavy chain, respectively. Indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) was performed to determine the effectiveness of the chicken IgY against C. muytjensii. The optimum conditions for detecting C. muytjensii by indirect ELISA and checkerboard titration of the antigen revealed an optimum average absorbance at the concentration of 18 ${\mu}g/mL$, having ca. $10^8$ coated cells per well. The anti-C. muytjensii IgY antibody had high specificity for C. muytjensii and low cross-reactivity with other tested pathogens. In this assay, no cross-reactivity was observed with the other genera of pathogenic bacteria including Escherichia coli O157:H7, Salmonella Typhimurium, Staphylococcus aureus, Bacillus cereus, Enterobacter aerogenes, Salmonella Enteritidis and Listeria monocytogenes. In addition, detection of C. muytjensii in infant formula powder showed a low matrix effect on the detection curve of IC-ELISA for C. muytjensii, with similar detection limit of $10^5$ CFU/mL as shown in standard curve. These findings demonstrate that the developed method is able to detect C. muytjensii in infant formula powder. Due to the stable antibody supply without sacrificing animals, this IgY can have wide applications for the rapid and accurate detection of C. muytjensii in dairy foods samples.

Simple and rapid colorimetric detection of African swine fever virus by loop-mediated isothermal amplification assay using a hydroxynaphthol blue metal indicator

  • Park, Ji-Hoon;Kim, Hye-Ryung;Chae, Ha-Kyung;Park, Jonghyun;Jeon, Bo-Young;Lyoo, Young S.;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.1
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, a simple loop-mediated isothermal amplification (LAMP) combined with visual detection method (vLAMP) assay was developed for the rapid and specific detection of African swine fever virus (ASFV), overcoming the shortcomings of previously described LAMP assays that require additional detection steps or pose a cross-contamination risk. The assay results can be directly detected by the naked eye using hydroxynaphthol blue after incubation for 40 min at 62℃. The assay specifically amplified ASFV DNA and no other viral nucleic acids. The limit of detection of the assay was <50 DNA copies/reaction, which was ten times more sensitive than conventional polymerase chain reaction (cPCR) and comparable to real-time PCR (qPCR). For clinical evaluation, the ASFV detection rate of vLAMP was higher than cPCR and comparable to OIE-recommended qPCR, showing 100% concordance, with a κ value (95% confidence interval) of 1 (1.00~1.00). Considering the advantages of high sensitivity and specificity, no possibility for cross-contamination, and being able to be used as low-cost equipment, the developed vLAMP assay will be a valuable tool for detecting ASFV from clinical samples, even in resource-limited laboratories.

Analytical Determination of Vitamin B12 Content in Infant and Toddler Milk Formulas by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

  • Lee, Jung-Hoon;Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.6
    • /
    • pp.765-771
    • /
    • 2015
  • The development of a sample preparation method and optimization of the analytical instrumentation conditions were performed for the determination of the vitamin B12 content in emulsified baby foods sold on the Korea market. After removal of the milk protein and fats by chloroform extraction and centrifugation, the vitamin B12 was water extracted from the sample. Following filtration of the solution through a nylon filter, the water-soluble extract was purified by solid-phase extraction using a Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). The solution eluted from the cartridge was dried under a stream of nitrogen gas and reconstituted with 1 mL of water. The sample solution was injected into an LC-MS/MS system after optimizing the mobile phase for vitamin B12 detection. The calibration curve showed good linearity with the coefficient of correlation (r2) value of 0.9999. The limit of detection was 0.03 µg/L and the limit of quantitation was 0.1 µg/L. The method of detection limit was 0.02 µg/kg. The vitamin B12 recovery from a spiking test was 99.62% for infant formula and 99.46% for cereal-based baby food. The sample preparation method developed in this study would be appropriate for the rapid determination of the vitamin B12 content in infant formula and baby foods with emulsified milk characteristics. The ability to obtain stable results more quickly and efficiently would also allow governments to exercise a more extensive quality control inspection and monitoring of products expected to contain vitamin B12. This method could be implemented in laboratories that require time and labor saving.

Fault Detection and Diagnosis for Induction Motors Using Variance, Cross-correlation and Wavelets (웨이블렛 계수의 분산과 상관도를 이용한 유도전동기의 고장 검출 및 진단)

  • Tuan, Do Van;Cho, Sang-Jin;Chong, Ui-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.7
    • /
    • pp.726-735
    • /
    • 2009
  • In this paper, we propose an approach to signal model-based fault detection and diagnosis system for induction motors. The current fault detection techniques used in the industry are limit checking techniques, which are simple but cannot predict the types of faults and the initiation of the faults. The system consists of two consecutive processes: fault detection process and fault diagnosis process. In the fault detection process, the system extracts the significant features from sound signals using combination of variance, cross-correlation and wavelet. Consequently, the pattern classification technique is applied to the fault diagnosis process to recognize the system faults based on faulty symptoms. The sounds generated from different kinds of typical motor's faults such as motor unbalance, bearing misalignment and bearing loose are examined. We propose two approaches for fault detection and diagnosis system that are waveletand-variance-based and wavelet-and-crosscorrelation-based approaches. The results of our experiment show more than 95 and 78 percent accuracy for fault classification, respectively.

Microbiological Hazard Analysis for Agricultural Products Processing Center of Tomato and Recommendations to Introduce Good Agricultural Practices (GAP) System (Good agricultural practices(GAP) 제도 도입을 위한 토마토 산지유통센터의 미생물 위해분석)

  • Lee, Hyo-Won;Yoon, Yo-Han;Seo, Eun-Kyoung;Kim, Kyeong-Yeol;Shim, Won-Bo;Kil, Joong-Kwon;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.210-214
    • /
    • 2009
  • This study identified microbial risk factors in agricultural products processing center (APC) through the microbial hazard analysis to introduce good agricultural practices (GAP) system in APCs. Samples were collected from surroundings (basket, tray loader, weighing cup, collector, box) and workers by swabbing (glove and cloth) and glove juice method (hand) to enumerate total bacteria, coliform, Staphylococcus aureus, Escherichia coli, Escherichia coli O157:H7 and Salmonella. The levels of total bacterial and coliform populations recovered from surroundings were 2.4-5.7 log CFU/100 $cm^2$ and 2.3-5.7 log CFU/100 $cm^2$ or hand for surroundings, and workers, respectively samples were 2.3-5.7 log CFU/100 $cm^2$ or hand. Escherichia coli populations were determined to be below detection limit. S. aureus and Salmonella populations recovered from surroundings were 3.0-4.4 log CFU/100 $cm^2$ and close to detection limit, respectively. Corresponding bacterial populations to worker's samples were 2.8-5.2 log CFU/100 $cm^2$ or hand (S. aureus) and below detection limit (Salmonella). Bacterial populations of APC certified facilities were similar (p${\geq}$0.05) with those of uncertified facilities. These results showed that this study should be useful in development of GAP models to improve microbial safety in APCs.

The Improved Method for Precise Determination of Pu Isotope Ratio using MC-ICP-MS (다중검출기유도결합플라즈마질량분석기를 이용한 Pu 동위원소비 정밀 분석법)

  • Yim, Seong-A;Han, Eun-Mi;Chae, Jung-Seok;Yun, Ju-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.117-123
    • /
    • 2010
  • Plutonium is by far the most important of the transuranic elements which have been released into the environment due to radio-toxicity and long term radiation effects on humans. And Pu isotope ratio ($^{240}Pu/^{239}Pu$) is of great interest because this ratio is used as a fingerprint for different sources. Mass spectrometry has been used as an useful atom counting technique with several advantages over decay counting techniques for the determination of Pu isotopes. It enables a determination of Pu isotope ratio in the environmental samples with a low detection limit and a short determination time. An ICP-MS is the representative mass spectrometry for Pu determination. In this study, the precision of $^{240}Pu/^{239}Pu$ isotope ratio was improved by using 4 multiple ion counters of MC-ICP-MS. The detection limit of $^{239}Pu$ and $^{240}Pu$ were $0.10\;fg\;ml^{-1}$ ($0.24\;{\mu}Bq\;ml^{-1}$), $0.12\;fg\;ml^{-1}$ ($0.97\;{\mu}Bq\;ml^{-1}$), respectively. The relative standard deviation of $^{240}Pu/^{239}Pu$ isotope ratio was less than 1 % in trace level. The various reference materials (seawater, soil and sediment) were analyzed to verify this method and their analytical results were in good agreement with the certified (or recommended value) value.

Comparison of the Analytical Method for 3-Monochloropropane-l,2-diol in Food (식품 중 3-monochloropropane-1,2-diol의 분석법 비교 연구)

  • Yoo, Seung-Seok;Oh, Chang-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.360-365
    • /
    • 2007
  • The studies for the derivatization of 3-monochloropropane-1,2-diol (3-MCPD) were performed mainly as acylation with HFBI (heptafluorobutyrylimidazole), alkylation with PBA (phenylboric acid) and silylation with BSTFA (N,O-bis[trimethylsilyl]trifluoroacetamide). Also silylation with MTBSTFA(N-methyl-N-[tert.-butyldimethylsilyl] trifluoroacetamide) and acylation with MBTFA (N-Methyl-bis[trifluoro-acetamide]) were also considered. Except the TBDMS derivative of 3-MCPD, all the derivatives were detected well. The derivatives of 3-MCPD with HFBI, PBA and BSTFA showed below 10 ${\mu}g/kg$ which was sensitive enough to satisfy Korea maximum residue limit 0.3 mg/kg. Among the tested adsorbents, Extrelut20 and Florisil were evaluated as the proper adsorbents to eliminate the soy sauce matrix for 3-MCPD. Ethyl acetate was the most efficient eluent with good recovery rate. The desired surrogate compound and internal standard were 1,2-butanediol and 1,2-dibromo-3-chloropropane, respectively. The limit of detection for PB-MCPD and TMS-MCPD were 10.16 and 7.06 ${\mu}g/kg$ on GC/MSD, respectively. HFB-MCPD derivative showed the lowest detection limits 2.98 and 5.32 ${\mu}g/kg$ by GC/ECD and GC/MSD, respectively.