• Title/Summary/Keyword: Limit Distance

Search Result 481, Processing Time 0.023 seconds

A Study on Sunshine Environment with Different Distance between Buildings (인동간격에 따른 일조환경에 대한 연구)

  • 최용석;최지혜;김용식
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • Apartment design in residential Area is restricted by building distance limit code. Building distance limit decreases gradually to the 0.8H(height), and residential area has 250% site area ratio by building code, so site using has become efficient. In this study, examine the relationship between present building distance limit and right of daylighting environment by computer simulation. As well, high-rise residential officetel and multipurpose residential building becomes increase in commercial non-residential area. In the domestic, residential type multipurpose building made at the business area or central business area has 400∼800% site area ratio by building code. However, at a dweller's point of view, there are much lacks of environmental consideration to provide suitable daylighting environment. And, POE: Post Occupancy Evaluation is not completed yet. In this study, however, progress architectural environment prediction, basis by right of daylighting, and examine the possibility of daylighting by architectural distance limit code in residental area and by high-rise, high-density residential building in non-residental downtown area.

The Prediction of Allowable Limit Distance about Human Body by Vibration Regulation (진동 규제기준에 따른 인체의 허용 한계거리 예측)

  • Song, Jeong-Un;Hong, Woong-Ki;Kim, Seung-Kon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.2
    • /
    • pp.289-296
    • /
    • 2012
  • The shock vibration such as machine vibration, blasting vibration etc. has effect on nearby structure as well as human body. The purpose of this study is to predict allowable limit distance of vibration about human body. First of all, vibration velocity such as PPV, PVS was measured by shock vibration experiment, and vibration level was calculated by conversion formula of vibration velocity. And then, allowable limit distance was analyzed by converted vibration level. The results are as follows : Firstly, the correlation coefficient of converted vibration level was over R=0.94, and vibration level caused by PVS was usually represented to high curve line. Secondly, the cross point of vibration level between ground and concrete condition was represented to 66.68dB(V), and allowable limit distance was represented to difference over three times when vibration regulation was raised from 65dB(V) to 80dB(V).

Influence of Sample Number on the Estimation of Blasting Coefficients and Limit Scaled Distance (측정수가 발파계수와 허용환산거리의 산정에 미치는 영향)

  • 양형식;전양수;정지문
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.814-820
    • /
    • 1998
  • Vibration data from two blasting sites were analyzed to determine the sufficient sample number for blasting vibration estimation. Most important result is that much more than 30 sample data and succeeding measurement are necessary to estimate confident blasting vibration level and to determine limit scaled distance.

  • PDF

Uplift capacity of horizontal anchor plate embedded near to the cohesionless slope by limit analysis

  • Bhattacharya, Paramita;Sahoo, Sagarika
    • Geomechanics and Engineering
    • /
    • v.13 no.4
    • /
    • pp.701-714
    • /
    • 2017
  • The effect of nearby cohesionless sloping ground on the uplift capacity of horizontal strip plate anchor embedded in sand deposit with horizontal ground surface has been studied numerically. The numerical analysis has been carried out by using the lower bound theorem of limit analysis with finite elements and linear optimization. The results have been presented in the form of non-dimensional uplift capacity factor of anchor plate by changing its distance from the slope crest for different slope angles, embedment ratios and angles of soil internal friction. It has been found that the decrease in horizontal distance between the edge of the anchor plate and the slope crest causes a continuous decrease in uplift capacity of anchor plate. The optimum distance is that distance between slope crest and anchor plate below which uplift capacity of an anchor plate has been found to decrease with a decrease in normalized crest distance from the anchor plate in presence of nearby sloping ground. The normalized optimum distance between the slope crest and the anchor plate has been found to increase with an increase in slope angle, embedment ratio and soil internal friction angle.

Visual Acuity of Fish - 1 . Relationship Between line Width and Distance at Visual Limit of Filefish Stephanolepis Cirrhifer - (어류의 시각에 관한 연구 - 1 . 쥐치의 시인한계에서의 선의 굵기와 거리와의 관계 -)

  • An, Young-Il;Yang, Yong-Rhim
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.3
    • /
    • pp.241-248
    • /
    • 1996
  • The relationship between width of line target and distance at the limit of discrimination was examined by means of the behavioral method, for filefish Stephanolepis cirrhifer from 11 to 15cm body length. Target distance was distance from beginning of partition board to target plate, and was varied from 50cm to 200cm. The target plate was made of white acrylic resin with a vertical black line in the center. The width of line target was varied from 0.2mm to 8.0mm. Fish were trained to respond to a line target and the width of line target reduced until the minimum width required to elicit a response was established. Rate of success was expressed as the percentage of target choices in 90 trials. The line acuity of filefish was found to be 0.58 at a target distance of 50cm. The rate of success decreased slowly as line target width decreased from 8.0mm to 1.5mm, and decreased suddenly for target widths less than about 1.5mm. The width of the line target D(mm) at the limit of discrimination was shown to be an exponential function of the target distance L(cm) as follows : D=exp(9.947$\times$$10^-3$.L+0.146)

  • PDF

The System for Long Distance Connection based on High Performance Serial Bus (고성능 시리얼 버스를 기반으로 한 원거리 접속용 장치)

  • 송정호;정민섭;강성봉
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.729-732
    • /
    • 1999
  • In this paper. we propose a system model and the associated control method for long distance connection using the High Performance Serial Bus, IEEE 1394. Though IEEE 1394-1995 Standard has connection distance limit of 4.5m, our proposed system can extend the limit further even without degrading network performance. And the current systems using IEEE 1394 don't have to make any change to use the proposed system.

  • PDF

Fog Generated Field Test for Criteria of Sign Size of Variable Speed Limit Signs (가변 제한속도 표지판 크기기준 정립을 위한 안개재현 현장실험)

  • Kim, Yongseok;Lee, Sukki;Kim, Soullam
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.87-96
    • /
    • 2016
  • OBJECTIVES : A fog generated field test was conducted to analyze the relationship between different sizes of variable speed limit signs and the legibility distance under various fog density conditions. By using this study, appropriate sizes of signs can be selected depending on the density of fog. METHODS : An actual tunnel was selected as the area for this test, as other places cannot maintain the fog condition because of rapid air current. A total 121 subjects were recruited for this test, which took place over the course of four days. The test on the first day was conducted under normal weather conditions for comparison. Visibility-distance detecting sensor was used to measure the visibility distance due to the fog density time, simultaneously with the evaluation of legibility distance by subjects. RESULTS : The test results show the relationship between the different sizes of signs and the legibility distance corresponding to the visibility distance due to both non-fog and fog generated conditions. According to the technical test results, appreciable amount of reduction in legibility distance due to fog was resulted in all sizes of signs. Moreover, the legibility distance is reduced proportionately with the decrease in the visibility distance due to fog. CONCLUSIONS : The results of this study can be used to select appropriate sizes of valuable speed signs under fog conditions. Hence, drivers can expect to have more room to respond to adverse weather conditions, thereby reducing the risk of accidents.

Fog Generated Field Test for Luminance Criteria of Variable Speed-Limit Signs (가변속도형 표지 휘도기준 정립을 위한 안개재현 현장실험)

  • Kim, Yongseok;Lee, Sukki;Kim, Soullam
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.77-85
    • /
    • 2016
  • OBJECTIVES : A fog generated field test was conducted to analyze the relationship between the luminance of variable speed-limit signs and the legibility distance under various fog density conditions. By using this study, appropriate luminance values can be selected depending on the density of fog. METHODS : An actual tunnel was selected as the area to conduct the test, as other places cannot maintain the fog condition because of rapid air current. Ninety-two subjects were recruited for this test, which took place during the course of three days. Visibility-distance detecting sensor was used to measure the visibility distance due to the fog density time, simultaneously with the evaluation of legibility distance by subjects. RESULTS : The test results show the relationship between luminance values and the legibility distance corresponding to the visibility distance due to fog. According to the technical test results, lower luminance value such as $7000cd/m^2$ corresponds to less legibility distance compared to higher values such as $20000cd/m^2$ or $40000cd/m^2$. However, the amount of difference between $20000cd/m^2$ and $40000cd/m^2$ is negligible in our test. CONCLUSIONS : The results of this study can be used to select appropriate luminance of valuable speed signs under fog conditions. Hence, drivers can expect to have more room to respond to adverse weather conditions, thereby reducing the risk of accidents.

Analysis and Simulation of SF6 Tracer Experiments for Tracking the Pollutant Transport (오염물질 이동 추적을 위한 SF6 추적자 실험 분석과 모사 연구)

  • 김영성;조성호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.397-410
    • /
    • 1998
  • Tracer experiments were performed 4 times in December 1992 on the relatively flat terrain and nearby building area adjacent to the Taedok Science Town in Korea. Each experiment was continued for relatively short period of 1 or 2 hours with intermittent release of SF6 up to 2.07g/s at 10m height. Movement of tracer plume was tracked by a continuous tracer analyzer installed on an air monitoring van. Simulation with INPUFF was carried out to analyze and predict experiments. Measured profiles of tracer plume were narrow and sharp while predicted profiles by INPUFF were broad and slowly varied. Tracer plumes were detected at a short distance of 0.5 to 2.2 km mainly due to intermittent release and high value of lower detectable limit. Various experimental conditions were tested by INPUFF simulation in order to find desirable conditions. Higher wind speed and less variable wind direction could yield longer distance of plume tracking only when the lower detectable limit was sufficiently low. Distance of plume tracking was long and did not much depend on the lower detectable limit in stable atmospheric conditions.

  • PDF