• Title/Summary/Keyword: Lightings

Search Result 163, Processing Time 0.022 seconds

Analysis of Roles of Lighting and Background Musik for Storytelling - a Case Study of Disney's Short Animated Film (스토리텔링에서의 조명과 배경음악의 역할 분석 -디즈니 단편 애니메이션 <페이퍼맨>을 중심으로)

  • Park, Eun-Hea
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.8
    • /
    • pp.988-995
    • /
    • 2015
  • In 2013, Academy Award for Best Animated Short Film was granted to Walt Disney's short animation, (2012). With various aspects of its excellence, I focus on the very effective use of digital lightings and underscores for storytelling as its success factors. In this respect, this paper aims at analyzing the roles of the visual factors, especially tone, contrast, etc. created by lightings, and audio factors, especially underscores, in the film's story development. I find that can be characterized by the well-built story structure with distinct three acts. The main stream of the story is expressed with the overall mood that is created by the fine adjustments of brightness of the main light, and contrast. And the direction and the intensity of the lighting successfully describe the emotions of the characters in each scene. In addition, I find that properly chosen and positioned underscores make the development of the story more dynamic and more harmonized.

Performance Evaluation of LEDs for the Substitution of Fluorescent Lighting Sources (형광등 대체용 LED 조명기구의 성능 평가)

  • Chang, Jun-Ho;Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.115-118
    • /
    • 2007
  • Recently, the development of LEDs is important and prevalent in the lighting market. The purpose of this study is to evaluate the performance of white LEDs by comparing with fluorescent lightings. First, this study performed to survey technical developments and design trend of white LEDs. Second, comparing white LEDs with fluorescent lightings which are widely used, this paper evaluated physical characteristics of white LEDs. Lastly, this study Performed subjective evaluation which is comparing side-by-side rooms installed LEDs and fluorescent luminaires to investigate psychological and physical evaluation. The results of this study could be used as fundamental data for the development of white LEDs.

  • PDF

A Study on Reliability Analysis for Reliability Testing & Field Degradation Data of LED Lighting (LED조명기기의 필드 열화데이터에 대한 신뢰성 분석에 관한 연구)

  • Yang, Seong-Yong;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.54-59
    • /
    • 2011
  • LED lightings typically do not fail catastrophically during use. However, over time the light output will gradually depreciate. Even if there are same LED lighting, they are so different at all. because of dissimilar the use and environment of each LED lighting. In this paper, we make a description of reliability analysis procedures for the degradation data using collected field data. Reliability analysis procedures are consisted of estimating degradation models and failure time, verification of distribution and parameters of the distribution, and reliability measures estimation. At some point in time, the light emitted from an LED lightings depreciates to a level where it is no longer considered adequate for a specific application.

Development of Fin Expansion Type Cooling System using Heat Pipes for LED Lightings (히트파이프를 적용한 LED조명용 핀확장형 냉각시스템 개발)

  • Jung, T.S.;Kang, H.K.
    • Transactions of Materials Processing
    • /
    • v.21 no.2
    • /
    • pp.131-137
    • /
    • 2012
  • With the advantages of power savings, increased life expectancy and fast response time over traditional incandescent bulb, LEDs are increasingly used for many applications including automotive, aviation, display, and special lighting applications. Since the high heat generation of LED chips can reduce service life, degrade luminous efficiency, and cause variation of color temperature, many studies have been carried out on the optimization of LED packaging and heat sinks. In this study, a fin expansion type cooling device using heat pipe, instead of a solid aluminum heat sink, was designed for LED security lightings based on thermal resistance analysis. Numerical analysis and experimental validation were carried out to evaluate its cooling performance.

A Study on the Economic Analysis of LED Lightings in All-Electric Houses Using California Standard Practice Test (캘리포니아 테스트를 이용한 전기에너지주택 LED조명의 경제성 분석에 관한 연구)

  • Hwang, Sung-Wook;Lee, Hyun-Ju;Nah, Hwan-Seon;Kim, Jung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.1-7
    • /
    • 2011
  • Recently, all-electric house technology became one of the green growth technologies and is integrated with various areas such as electricity, machinery, architecture, material, and etc. Fossil fuel energy is used for heating and hot water supply in the conventional houses but electricity is adopted in the new conceptual houses to maximize advantages of electricity such as amenity, safety, cleanness, and so on. In this paper, an economic analysis is carried out when LED lightings are adopted using the California Standard Practice Test which has been used to estimate the effects of existing DSM (Demand Side Management) programs. The results are able to contribute to the diffusion of all-electric houses and the establishment of basic data and planning for DSM policies.

A Study on the Active EMI Filter for LED Driver (LED 구동장치용 능동 EMI 필터의 실현)

  • Lee, Dong-Ho;Choi, Min-Whan;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.62-68
    • /
    • 2015
  • Recently, LED is being used as various applications such as home lightings, work lightings and so on. EMI noise generated from LED driver have become a problem according to increase the use of LED. In this paper, Active EMI filter composed active and passive components is discribed as a method of solving a problem of EMI. The proposed filter is applied to the 160W LED load to verify performance experimentally. To compare the performance, We did an experiment using the proposed filter and the passive filter on the same 160W LED load and Driver System. As a result, The proposed Active EMI filter attenuated Conduction EMI noise better than any existing passive filter.

Study of the Characteristic and Optimization of Induction Lamp according to Gas Pressure and Amalgam Type (고출력 무전극램프의 가스압 및 아말감종류에 따른 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Kim, Yong-Kab;Park, Dae-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Currently, road lightings are installed with less than 400W of existing metal halide lamps. These road lightings are being replaced by energy-saving lightings. Induction lamps are expected to be more actively replaced with targets for tunnel lighting and high ceiling lighting. Therefore, it is necessary to develop high efficiency, high power induction lamps system. In this study, the gas type & pressure, amalgam type were designed for the high power of the induction lamps. And induction lamp system was optimized through electrical, optical characteristics analysis. It is optimized to the gas pressure 300~350 [mmHg] for the discharge tube of high power induction lamp and ferrite core. The driving circuit matching was completed with a induction lamp using indium amalgam. The rated power consumption of the induction lamp was optimized with 250 W (rated ${\pm}10%$)

A Study on the Outdoor Lighting of Campuses on the Ground of the User-Satisfaction (이용자 만족도에 의거한 캠퍼스 옥외조명 연구)

  • Kim Dong-Chan;Min Chang-Ki
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.1 s.108
    • /
    • pp.1-9
    • /
    • 2005
  • The purpose of this study is to form a night-view at a university to satisfy users through case studies of four representative university campuses with analyzing the lighting conditions and facility satisfaction. The result of this study is following. From the present lighting status, there are 664(l9types) lightings at Kyunghee University, 350(17types) at Sungkyunkwan University and 437(l9types) at Ajou University. Main materials of the lightings are metal, iron and stainless. Moreover, most illuminants are white-colored metal-halide lamp. There is no specially designed lighting facility because ready-made goods were used. Furthermore, the locations of lightings are not suitable so some are useless. Most main spatial illuminations are not satisfying outdoor standard, so it can be concluded that the designs of present campuses are not carrying on with-out plans. From the result, present campus lighting does not satisfy the desire of users in aesthetic and functional point of view but consider the luminosity. However, even though the luminosity does not standardize the law. It is because the design does not reflect a suitable standard with desire of users and it does not have a long term plan. Moreover, the campus design has no study about development plan even though it has enough green area which has a potential possibility to overcome the lack of green areas in a city. Therefore, it is needed to design a comprehensive campus plan which satisfies the desire of students and residents with considering promotion of excitement and harmony through adjusting luminosity of the lighting facilities and supplying various lighting resources.

The Master-Slave structure and Synchronization Method for a higher-Capacity Lighting Performance (대용량 조명연출을 위한 마스터-슬레이브 구조와 동기화 방안)

  • Choi, Seong-Cheol;Lee, Won-Ho;Moon, Byung-Koo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2559-2564
    • /
    • 2010
  • The indoor and outdoor lighting industry has become the bigger and more systemized using the semiconductor LED with each control R(Red), G(Green), B(Blue). The communication standard DMX512(ANSI E1.11) protocol of it can control and perform max. 512 lightings, especially 170 lightings in 24 bit true color. As the performance of below 100 lightings is distinguished small-size, this paper proposes a bigger capacity lighting performance above 1,000 using connection to 1 master to 32 slaves. Also, this paper proposes the synchronization method in order to accomplish a designed performance. In proposed method, the master sends the synchronization signal to slaves every 400ms. Slaves receive this signal and use to initialize the timer becoming the basis of DMX512 output. The example of the developed products using proposed method and the operation is introduced.

Experimental Studies on the Risk Assessment of Electrical Fire and Shock of LED Lighting for Outdoor (옥외용 LED 조명의 전기화재 및 감전 위험성 평가에 대한 실험적 고찰)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.77-97
    • /
    • 2011
  • In this paper, we studied risk assessments of electrical fire and shock of LED lightings for outdoor. We examined national regulations about the LED lighting for outdoor and analyzed the appearances and compositions of LED lightings. And, We experimented about water proof, line to line fault, line to line breakdowm, overvoltage, line to line leakage in overhead line or water of LED lighting. From experimental results, we know that there are risks of electrical fire and shock by abnormal conditions at the LED lighting. Therefore, the uses of protective devices and insulated type of converter are required for the electrical safety. We expect that the results of this study would be helpful for the improvement of regulations and standards for electrical safety and for the investigations of electrical accidents of LED lightings.

  • PDF