• Title/Summary/Keyword: Lighting system

Search Result 1,383, Processing Time 0.024 seconds

Application of Lightself to Buildings as a Integrated Daylighting System (건축물 일체형으로서 광선반형 자연채광시스템의 건축물 적용기법에 관한 연구)

  • Kim, Jeong-Tai;Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.17-24
    • /
    • 2002
  • For sustainable building design, using day lighting is considered a variable technique to save energy and create comfort indoor environments. Specially, the lightself as a integrated daylighting system is one of the most important techniques due to it's durability, availability and lighting performance. This paper aims to analyze the development and architectural application of a lightself system to buildings as a integrated day lighting system. For the study, advanced lightself systems developed in abroad such as "Integrated Enveloped and Lighting System", "Anidolic Daylighting System" and etc. are analyzed. Also, the architectural examples are investigated. As results, the new technologies such as optically treated reflective and sun-tracking are adopted to improve daylight performance. And, lots of environmentally friendly buildings are installed on integrated lightself system.

The Color Temperature Flexibility-typed LED Lighting Control System (색온도 가변형 LED 조명제어시스템)

  • Kim, Hye-Myeong;Yang, Woo-Seok;Cho, Young-Seek;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.284-288
    • /
    • 2015
  • The color temperature flexibility-typed Lighting Emitting Diode(LED) lighting control system proposed in this thesis employs Pulse Width Modulation(PWM) technique to control the brightness of LED lighting. The LED lighting used as a light source has 20W downlight composed of two types of LED chips: one is Warm White and the other is Cool white. One multi-sensor module consisting an infrared sensor, an illumination sensor, and a temperature sensor was made, to which Bluetooth wireless communication technique was applied to enable a smartphone application to control lighting brightness and identify the information collected from the sensor. CS-1000, a spectroradiometer, was used to measure LED dimming control and the changing values of a color temperature in eight steps. According to a test, it was found that it was possible to change a color temperature from 3187K of Warm White LED to 5600K of Cool White LED.

A study of Illumination on Floor Surface by Flat Form Louver of Top Lighting System (천창루버에 의한 내부공간 바닥면 조도변화와 설치방식에 관한 연구)

  • Kim, Mi-Hee;Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.132-138
    • /
    • 2011
  • Inducing the natural lighting into building has been commonly applied to the spaces where artistic objects are displayed to create better visual environment for the appreciation. The direct natural lighting, especially through top lighting system may, however, bring forth discoloing of highly light-sensitive materials such as paintings or demanding additional cooling load. In addition, it causes to create glare against appreciators or to yield in visual distraction due to the extreme contrast on the inner surfaces of the spaces. Shading device such as louver is capable of preventing such voidable cases with careful manipulation. This study aims to provide basic design guide-line when the flat-form louver has to be applied to top lighting system. Interaction between the daylight and louver was simulated by Reluxpro program with variation of the attachment location, the angle of the lover, surface reflectivity, to obtain the illumination of the floor surface. This study yields the louver just under the top lighting window with 90 degree angle gives the most desirable way of employment when the uniform illumination on the floor surface is required.

A Study on Design Requirements of Lighting system in Underground Streets (지하상가시설의 조명용 변전용량 기준설정에 관한 연구)

  • 김세동;최도혁
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.3
    • /
    • pp.43-46
    • /
    • 1996
  • This paper shows a reasonable design standard of lighting system in underground streets, that was made by the systematic and statistical way considering actual conditions, such as investigated lighting transformer capacity, electric power consumption for lighting, load characteristics, etc for 5 underground streets.

  • PDF

A Experimental Study the Showcase Lighting by Position of Light Source (광원의 위치를 중심으로 한 쇼케이스 조명실험연구)

  • 김현지;장상옥;안옥희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • This experimental study investigates the showcase display of cosmetic shops among the commercial space to suggest a desirable lighting by focusing on the lighting surroundings. The important outcomes of this study are summarized below. The result of the experiment for the showcase lighting; they need put the higher intensity lighting in inside for the local lighting and different effect. And for the emotional response, they need to put the horizontal lighting which is installed the behind of showcase and the vertical lighting for the front line lighting system.

A Study on the Evaluation of Lighting Energy Consumption by Control Strategy of the Electric Lighting (전기조명 제어 전략에 따른 조명에너지 소비량 평가에 관한 연구)

  • Yun, Gyeong;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.119-125
    • /
    • 2012
  • The objective of this study is to evaluate the electric lighting energy consumption carried out by Daysim program. A comparison between the measurement and simulated exterior global horizontal illuminance shows differences about 10% and it is very similar to the measurement. The interior illuminance simulated by Daysim are 18.9% lower than the measurement and simulated lighting energy consumption is 10% lower than the measurement. Corrected annual lighting energy simulation results show that the best case is the combination of occupancy switch-off and dimming system with automatic controlled blinds (E-3). In case of no blinds, it occasionally derives the minimum lighting energy consumption but it causes the glare, so we need to be careful for choosing the control strategy. For the overcast sky, the lighting energy consumption is not changed significantly by control strategy while the lighting energy in the clear sky is changed noticeably. So we must know the right strategy for each case to control the electric lights and blinds.

The Improved Characteristics of the Stand-alone PV System by the Independent Battery Control Method (밧데리 개별 제어 방식에 의한 소규모 독립형 태양광 발전 시스템의 특성 개선)

  • 강신영;이양규;김광헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.482-489
    • /
    • 2002
  • This paper studies the stand-alone photovoltaic system for the solar lighting lamp. The solar lighting lamp has PV modules, batteries, and charge & discharge system. The charge efficiency is improved for the control of each battery which is divided the charge from the discharge to change the structure of existing solar lighting lamp charge & discharge system. so, the charge and discharge times are reduced of 50% and the depth of discharge control can be controlled in the discharge cut off voltage. It can be effective of the battery use. If a battery is out of order, this system can be executed for a regular period. So we saved the repair cost and developed of system's stabilization. It Is possible to make economical effects to apply for solar lighting lamp used photovoltaic system.

Load Pattern Considerations of The Photovoltaic Lighting System by Using Computer-based Date Acquisition System (컴퓨터기반의 DAS를 적용한 태양광 조명설비의 운용패턴 고찰)

  • 황명근;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.1-10
    • /
    • 2003
  • Comparing to the conventional power systems, PV(photovoltaic) outdoor lighting system applications are evaluated as the most economical application. In this paper, we installed two PV lighting systems, which uses LPS(low pressure sodium) and electrodeless lame as their loads, and applied a computer-based data acquisition system using the Labview program for monitering purpose and effective operations, considering battery life time Also, we observed the generated power from the solar array, and energy losses comparing to its installed capacity. Because most PV system performance procedures have looked at the performance of the individual components and have deficiency of addressing how the integrated system works, we confirmed the decrease possibility of the solar amy capacity after analyzing the performance of the installed PV lighting systems.

Information System of Smart u-LED Lighting Energy based on Zigbee Mesh Network (지그비 메쉬 망 기반 스마트 u-LED 전력제어 시스템)

  • Kim, Sam-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.77-83
    • /
    • 2013
  • Nowadays, the limitation of Lighting control and management skills is the excessive cost of equipments, the operational difficulties and wasting energy. To solve this problem is in need of communication and management S/W that is worked out complexly well as a information system of smart lighting energy, which is loaded wireless network facility. This paper made a study od the energy saving technology through energy monitoring and we developed LEIS(Lighting Energy Information Sysem) to converge this one. LEIS is monitoring and control lighting energy data that is collelcted from sensors by Zigbee mesh network and shows lighting use information by visualization to users. It is consists of lighting energy information data base based on LEM(Lighting Energy Metering) information and LEIS Web application, provide function scenario to manage energy optimization through LEIS.