• 제목/요약/키워드: Lighting load

검색결과 121건 처리시간 0.024초

업무용 건축물의 실내 조명기구 특성에 따른 발열 효과에 관한 연구 (Interior heating effect in an office building according to heat properties of light fixture)

  • 이윤진;안병립;김종훈;정학근;장철용;김태연
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Generally, 30% of the total energy consumption in office building is used for artificial indoor lightings, and almost 75-85% of electric power in fluorescent and Light-Emitting Diode (LED) lightings can be dissipated as a form of heat into indoor environment. The heat generated by indoor lightings can cause the increase of cooling load in office buildings. Thus, it its important to consider indoor lightings as a heat and light source, simultaneously. Method: In this study, we installed two kinds of indoor lightings including fluorescent and LED lightings and measured surface temperature of both indoor lightings. In addition, we obtained ambient temperature of indoor space and finally calculated total heat dissipated from plenum area and surface of lightings. Result: Total indoor heat gain was 87.17Wh and 201.36Wh in cases of six 40W-LED lightings and 64W-fluorescent lightings, respectively.

Battery SOC(State of Charge)측정을 통한 태양광발전 시스템 운영 방안 연구 (A study on the operating method for Photovoltaic system through the SOC measurement of batteies)

  • 송정용;서유진;권오상;정관철;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.1-7
    • /
    • 2004
  • In this paper, the new improved method for photovoltaic system was studied available for a lighting load by measuring the state of charge of lead-acid batteries. Photovoltaic systems has been evaluated as one of the most new and renewable energy and especially, the Stand-Alone Photovoltaic system has been used to a street light, a road sign light, an air caution light, an emergency call. Many Stand-Alone PV system are installed by a group. Although the pre-installation cost of PV system is high and it has not been operated due to the absence of optimal management standards. In this paper, it is proposed a new operating method by the measurement of lead-acid battery's SOC with a Ah balancing.

스마트 제어를 이용한 하이브리드 형 제어장치 연구 (A Study on Hybrid Control Unit Using a Smart Control)

  • 김희철
    • 한국전자통신학회논문지
    • /
    • 제11권11호
    • /
    • pp.1093-1100
    • /
    • 2016
  • 본 연구는 슈퍼캐패시티 EDLC(:Electric double layer capacitor)를 적용한 가로등용 태양광-풍력 하이브리드 발전시스템 성능의 우수함과 안정성을 입증하고자 한다. 독립전원용 태양광-풍력 하이브리드 발전시스템의 부하로 LED 광원을 이용한 조명장치를 적용하고 고출력 발전시스템을 통한 가로등 시스템 장치의 개발을 목표로 하고 있다. 발전된 전력을 배터리에 저장하는데 있어서 보조장치로 적용될 EDLC는 기존의 컨트롤러와는 달리 배터리의 고출력과 긴 수명을 보장할 수 있어 기존장치에 비해 유지보수가 적게 들고 우수한 성능을 확보할 수 있다.

Analysis and Design Considerations for a High Power Buck Derived LED Driver with Extended Output Voltage and Low Total Harmonic Distortion

  • Lv, Haijun;Wu, Xinke;Zhang, Junming
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1137-1149
    • /
    • 2017
  • In order to reduce the cost, improve the efficiency and simplify the complicated control of existing isolated LED drivers, an improved boundary conduction mode (BCM) Buck ac-dc light emitting diode (LED) driver with extended output voltage and low total harmonic distortion is proposed. With a coupled inductor winding and a stacked output, its output voltage can be elevated to a much higher value when compared to that of the conventional Buck ac-dc converter, without sacrificing the input harmonics and power factor. Therefore, the proposed Buck LED driver can meet the IEC61000-3-2 (Class C) limitation and has a low THD. The operating principle of the topology and the design methodology of the ac-dc LED driver are presented. A 150 W ac-dc prototype was built in the laboratory and it shows that the input current harmonics meet the lighting standard. In addition, the THD is less than 16% at a typical ac input. The peak efficiency is higher than 96.5% at a full load and a normal input.

RECOGNITION ALGORITHM OF DRIED OAK MUSHROOM GRADINGS USING GRAY LEVEL IMAGES

  • Lee, C.H.;Hwang, H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.773-779
    • /
    • 1996
  • Dried oak mushroom have complex and various visual features. Grading and sorting of dried oak mushrooms has been done by the human expert. Though actions involved in human grading looked simple, a decision making underneath the simple action comes from the result of the complex neural processing of the visual image. Through processing details involved in human visual recognition has not been fully investigated yet, it might say human can recognize objects via one of three ways such as extracting specific features or just image itself without extracting those features or in a combined manner. In most cases, extracting some special quantitative features from the camera image requires complex algorithms and processing of the gray level image requires the heavy computing load. This fact can be worse especially in dealing with nonuniform, irregular and fuzzy shaped agricultural products, resulting in poor performance because of the sensitiveness to the crisp criteria or specific ules set up by algorithms. Also restriction of the real time processing often forces to use binary segmentation but in that case some important information of the object can be lost. In this paper, the neuro net based real time recognition algorithm was proposed without extracting any visual feature but using only the directly captured raw gray images. Specially formated adaptable size of grids was proposed for the network input. The compensation of illumination was also done to accomodate the variable lighting environment. The proposed grading scheme showed very successful results.

  • PDF

눈부심 저감을 고려한 LED광원 계류장 조명탑 설계에 관한 연구 (A Study on the Design of a Floodlighting Tower with LED Source of Light Considering the Reduction of a Glare)

  • 김동수;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제28권4호
    • /
    • pp.271-275
    • /
    • 2015
  • The floodlighting assists the pilot in taxiing the aircraft into and out of the final parking position and provide lighting suitable for passenger to embark and debark and for personnel to load and unload cargo. It is composed of sodium lamps which is consuming high energy. It needs to develop a dedicated LED lamp to replace the existing lamps. In this paper, We propose a suitable asymmetric angle of LED lamps to avoid a pilot's glare and to meet the standard illumination. For this, we analyze asymmetric angle of sodium lamps which are using in airport and confirm whether the illumination distribution and glare index meet the relating standards by using simulation method. Also, we study the needs of asymmetric characteristics of LED ramp by simulating the LED lamps with and without asymmetric characteristics of ramp respectively. With the simulation result, finally we propose the best asymmetric angle of LED lamp to meet the average illumination standard, and avoid a pilot's glare.

끼움벽과 단주효과를 고려한 학교건축물의 내진성능평가 (Seismic Performance Evaluation of School Building Short Column Effect)

  • 주창길;한주연;박태원
    • 교육시설 논문지
    • /
    • 제21권2호
    • /
    • pp.33-39
    • /
    • 2014
  • In the case of low-rise buildings in seismic performance evaluation, lateral force resistance of the pillars affects the seismic performance of the building. Evaluation of the seismic performance of the column is determined by the holding performance is evaluated by comparing the shear strength and bending strength it was destroyed bylow intensity. In case of the school building, in order to install the large windows for ventilation and lighting of the partition walls are located between the pillars. The case of the pillars of these, shear failure occurs in the event of an earthquake is often, in the seismic performance evaluation, partition wall and the wall of the shim is evaluated ignoring, pillar of the general pillars If you have to calculate the results of the seismic performance distorted that are destroyed by bending behavior can be evaluated as often. Results of the study, when assessed by distinguishing the effective length of the column, it was found that when a seismic load is applied, it is possible to accurately predict the failure mode, reliable results of seismic performance evaluation of the school building.

투광형 비정질 BIPV 시스템의 LCC 평가에 관한 연구 (A Study on the Life Cycle Cost Analysis of the See-through a-si Building Integrated Photovoltaic System)

  • 이한명;오민석;김회서
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.1-10
    • /
    • 2009
  • This study was carried out to evaluate the Life Cycle Cost(LCC) of three types of RTPV(Building Integrated Photovoltaic) systems-Glass plus Granite. Crystalline BIPV and See through Amorphous BIPV-which were vertically installed to generate the same power output(76 kW level). Initial investment costs. cost. savings and maintenance costs had been predicted during the period of analysing the LCC of three types of BIPV(Building Integrated Photovoltaic) systems installed for the purpose of evaluating the LCC. In case of cost savings, it had been analyzed by measuring the amount of electric power generated, reduction in lighting load and heat & cooling loads through simulation. From this analysis, it was predicted that the See-through amorphous BIPV offering cost saving advantages demonstrated the economical efficiency similar to the Class plus Granite when it is backed by more than 20 years of durability.

건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구 (A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings)

  • 정영선;정해권;장희경;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

어린이집의 넷 에너지 제로화 구현에 관한 사례분석 (A Feasibility Case Study on Net-Zero Energy Daycare Center)

  • 김지현;임희원;신우철
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.185-192
    • /
    • 2019
  • In this study, we, through case studies, formulated a method to implement net-zero energy daycare center at the current insulation and technology level, and calculated its energy expense. The reference model was a medium sized daycare center whose number of children was 99. We analyzed the energy consumption status for the reference model and developed TRNSYS simulation analytical model to realize net-zero energy . We assumed the reference model to be "All Electric Building" where all energy including cooking is supplied by electricity. The result is summarized as follows: First, the annual electricity consumption of daycare center was 53,291kWh. Plug load occupied the largest share of 48% followed by lighting, 10%, cooling, 9%, cooking, 9%, heating, 8%, hot water, 5% and ventilation, 2%. Second, the photovoltaic installation capacity to realize net-zero energy was 40.32kWp and its annual generation was 53,402kWh. Third, the annual energy expense(electricity bill) by realizing net-zero energy was 2,620,390won.