• Title/Summary/Keyword: Lighting energy saving

Search Result 219, Processing Time 0.025 seconds

Evaluation of Lighting Energy Saving Rate in a Small Office Space (소규모 사무공간의 조명에너지 절감율 평가에 관한 연구)

  • Kim, Han-Yong;Yun, Gyeong;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.50-58
    • /
    • 2012
  • The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m.

A Cost Effective Energy Saving of Fluorescent Lighting in Commercial Buildings

  • Lee, Seong-Ryong;Nayar, Chemmangot V.
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.215-222
    • /
    • 2012
  • Lighting represents a significant component of commercial buildings, particularly office buildings. Fluorescent lighting is invariably used in all commercial, industrial and residential areas. A significant amount of lighting energy is wasted every day by leaving the lights on and not utilizing daylight energy. However, if daylight illuminance can be harnessed, this will reduce the electricity consumption of fluorescent lamps and save energy. This paper explains possible significant savings in lighting energy consumption and hence in costs, without reducing the performance and visual satisfaction in office or industrial buildings. It is proposed to obtain energy saving by reducing the supply voltage without degradation in lighting performance. Experimental results confirm that as much as 20% of electrical energy can be saved by reducing about 9% of the supply voltage, without noticeably affecting light output while complying with lighting standard limits.

An Development of Landscape Lighting Power Control System with Solar Cell Generator Equipment for Energy Saving (에너지절감을 위한 태양광발전설비 연계형 경관조명 전력제어시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.364-371
    • /
    • 2010
  • In this paper, we propose the landscape lighting power control system with solar sell generator equipment for energy saving, and also which is included the landscape lighting power transformation device. The power transformation device can check inverse current in the power of the solar cell module and control the power of the battery. And we present the design of landscape lighting power control system. The power control system uses microprocessor with charging system and power transformation device. And also it can control the power of loads under consideration intensity of illumination. The landscape lighting loads are composed of LED(Lighting Emitting Diode) and HID(High Intensity Discharge)lamps. To evaluate property, we installed the solar cell array which generate three kilo watt power. Experimental results show that the proposed system can have stability and energy saving on the mixed configuration of electric loads with DC and AC lamps.

Effect of Lighting Saving Using High Efficiency Reflector (고효율 반사갓을 이용한 등기구 저감효과)

  • Cho, Huyn-Kyung;Kim, Jae-Chul;Jung, Seung-Bock;Im, Sang-Kug
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.148-153
    • /
    • 2006
  • This paper analyzes the effect of the energy saving and evaluates the economics using High Efficiency lighting. About 18 percent (17,000GWh) of total power demands in Korea m consumed i]l the lighting field. There isa lot of energy potential that can be saved because the power demand isolwer relatively than the others parts. The existing lighting that its length and electric energy are 32[mm] and 40[w] can alternate with high efficiency lighting which its length and electric energy are 26[mm] and 32[w]. Two Lightings is measuring the illumination and the electric energy and then are analyzed into the effect of the lighting saving by measurement.

  • PDF

Analysis of Saving Rates according to Energy Consumption Factors in Office Building (사무소 건물의 에너지 소비 요소별 절감률 분석)

  • Park, Byung-Il;Yang, In-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.115-122
    • /
    • 2016
  • In this study, 21 energy reduction factors were selected as architecture, system & operation, and lighting and equipment parts to analyze reduction method of the load occurring in office buildings. Energy consumption simulation was performed. In the architecture part, saving rate (1.53%) of "occupant density" factor was the most efficient. In the system and operation part, saving rate (1.28%) of "interior VAV and exterior FPU type" factor was the most efficient. In case of lighting and equipment part, saving rate (12.42%) of "schedule" factor was the most efficient. In the three parts, saving rate of the lighting and equipment part was 27.32%. This was caused by the "schedule" factor. Saving rates of the architecture part and the system and operation part were 3.39% and 1.20%, respectively.

The Effect of Remodeling Replacement of Photovoltaic Power Generation System in Fish Farm : Analysis of Energy Saving Effect through Simulation (수조식 양식장의 태양광발전시스템 리모델링 교체 효과: 시뮬레이션을 통한 에너지절감효과 분석)

  • Choi, Hyunseok;Na, Jonghyuk;Lee, Hyunyoung;Noh, Jayeop
    • Current Photovoltaic Research
    • /
    • v.9 no.1
    • /
    • pp.11-16
    • /
    • 2021
  • In the past, marine pollution caused by radioactivity and wastewater discharge caused mass destruction. As an alternative, the land farming system became common and operational. In recent years, safety and environmental problems caused by declining population due to aging of fishermen and underdeveloped facilities have always been lurking, so improvement is urgently needed. As part of the new renewable energy 3020 plan announced by the government in 2017, a new model was proposed to improve the environment as well as save energy when the roof of a water tank farm was remodeled into a solar power system. Study, when the existing roof was remodeled and replaced with a water tank farm in Busan as an empirical model, the energy saving rate was analyzed by comparing the actual electricity consumption and power generation.

Energy Saving System Based on the Human Sensing Technique (인체감지를 통한 에너지절약 시스템 개발)

  • Lee, Jong-Pil;Ji, Pyeong-Shik;Shin, Kwan-Woo;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.4
    • /
    • pp.205-209
    • /
    • 2004
  • This research is investigated an energy saving system based on human detecting technique. It saves a lot of energy by automatic switching method of lighting, appliance, and so on. Existence of people on space is detected by infrared ray sensor. If there is not anybody during definite time, then main controller of system sends "power off" signal to lighting switches, and outlets. When people are detected again, turn on lighting switches and outlets. Result of this research is adaptable for classrooms and offices, and great effect of energy saving is expected.

The Summer Cooling and Lighting Energy Performance Evaluation of Small Office Buildings with Venetian Blinds (블라인드를 고려한 여름철 소규모 사무소 건물의 냉방 및 조명에너지 평가)

  • Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • The daylighting control system has to be applied to prevent the excessive incident daylight and reduce energy use. As the one of the most useful daylighting control systems, the blind system is simple and easy to install on the window for small office buildings. This study aims to evaluate the summer energy performance of small office buildings by venetian blinds and energy saving strategy of ministry of knowledge economy in korea. For the study, the simulations have been executed on blind installation conditions and lighting control methods. As results, the energy loads cut down 22 to 25(%) by using blind energy. Also, the efficient shows high on EMS system and low on $45^{\circ}$ slat angles. Also, using energy saving strategy can reduce about 13(%) energy load.

Efficient Lighting System for Amenity Light Environment (쾌적 빛 환경을 위한 효율적 조명 시스템)

  • Choi, Jong-Hyo;Oh, Myoung-Won;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.136-141
    • /
    • 2009
  • Considerable part of energy consumption is occurred by through buildings. Especially, Lighting energy consumption is most part of one in building. There is very various ways and systems for saving lighting energy. In method, It can be divided Passive Daylighting System and Active Daylighting System. Louver, Screen and use of window's character is representative ways of passive system. Reflection mirror, optical pipe and optical fiber is representative method of active system. Introducing day light on which place can't be introduced day light by typical method is important advantage of active system. Except introducing day lighting methods, efficient lighting management system can save lighting energy. It called lighting automation system. Representatively, Occupancy-related automation and Brightness-related automation system is that. According to occupancy and introducing daylighting level properly operate lamp's intensity of illumination that can save lots of energy. Though Introducing daylighting method, effective lighting system we can get proper intensity of illuminance level and energy saving.

  • PDF

A Study on the User and Location Awareness Technology Applied Dimming Lighting Control System to Save Energy (에너지 저감을 위한 사용자 및 위치인식 기술 적용 디밍 조명제어 시스템 연구)

  • Choi, Kihyun;Kim, Yongseong;Lee, Henagwoo;Seo, Janghoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.14-23
    • /
    • 2015
  • Although research and technology developments have recently increased to save lighting energy within buildings, such research and technology development are judged to be unsuitable for energy savings since they are limited in the sense that the application of the technology is fragmented. This study proposes a user and location awareness technology applied to dimming lighting control system and verified the effectiveness of energy savings by building a test bed. The results were as follows : 1) This study suggested a user and location awareness technology applied to dimming lighting control system. 2) The system shows 96.6% and 82.8% energy saving rates, respectively, on the basis of one user, compared to an on/off lighting control and the user and location awareness technology applied to on/off lighting control system. 3) The energy consumption of the user and location awareness technology applied to on/off lighting control system and the user and location awareness technology applied to dimming lighting control system increased to 96.6%, 88.3%, and 59.6% and 82.8%, 85.0%, 51.5%, respectively, on the basis of one, two, and three users, compared to the on/off lighting control system. This study confirmed the energy saving performance of the user and location awareness technology applied to the dimming lighting control system through performance evaluation. In this regard, further study needs to be undertaken to evaluate the performance at night time.