• 제목/요약/키워드: Lighting Maintenance

검색결과 121건 처리시간 0.026초

Earlier Metabolizable Energy Intake Level Influences Heat Production during a Following 3-Day Fast in Laying Hens

  • Ning, D.;Guo, Yuming;Wang, Y.W.;Peng, Y.Z.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권4호
    • /
    • pp.558-563
    • /
    • 2013
  • The present study was conducted to estimate energy requirements for maintenance in laying hens by using indirect calorimetry and energy balance. A total of 576 28-wk-old Nongda-3 laying hens with dwarf gene were randomly allocated into four ME intake levels (86.57, 124.45, 166.63 and 197.20 kcal/kg body weight $(BW)^{0.75}$ per d) with four replicates each. After a 4 d adaptation period, 36 hens from one replicate were maintained in one of the two respiration chambers to measure the heat production (HP) for 3 d during the feeding period and subsequent 3 d fast. Metabolizable energy (ME) intake was partitioned between heat increment (HI), HP associated with activity, fasting HP (FHP) and retained energy (RE). The equilibrium FHP may provide an estimate of NE requirements for maintenance (NEm). Results showed that HP, HI and RE in the fed state increased with ME intake level (p<0.05). Based on the regression of HP on ME intake, the estimated ME requirements for maintenance (MEm) was 113.09 kcal/kg $BW^{0.75}$ per d when ME intake equals HP. The FHP was decreased day by day with the lowest value on the third day of starvation. Except for lowest ME intake level, the FHP increased with ME intake level on the first day of starvation (p<0.05). The FHP at the two higher ME intake levels were greater than that at the two lower ME intake levels (p<0.05) but no difference was found between the two lower ME intake levels. Linear regression of HP from the fed state to zero ME intake yielded a value of 71.02 kcal/kg $BW^{0.75}$ per d, which is higher than the extrapolated FHP at zero ME intake (60.78, 65.23 and 62.14 kcal/kg $BW^{0.75}$ per d for the first, second and third day of fasting, respectively). Fasting time, lighting schedules, calculation methods and duration of adaptation of hens to changes in ME intake level should be properly established when using indirect calorimetry technique to estimate dietary NE content, MEm and NEm for laying hens.

CCFL유도등의 전기적 특성 분석 (Analysis of Electrical Characteristics of CCFL Exit Light)

  • 정종진
    • 한국재난정보학회 논문집
    • /
    • 제17권1호
    • /
    • pp.184-193
    • /
    • 2021
  • 연구목적: 본 연구에서는 CCFL유도등의 동작원리가 일반 조명기기와 동일하여 일반 조명기기의 램프 안정기 성능인증 기준인 KS기준에서 광원의 특성에 영향을 줄 수 있는 시험항목을 도출하여 CCFL유도등의 특성을 분석하였다. 또한 CCFL광원의 전기적 특성과 온도 특성의 연관성을 분석하여 광원 수명에 미치는 영향을 고찰하였다. 연구방법: 실험에 사용된 시료는 대형, 중형, 소형 등 각 크기별 2개 제조사의 제품을 대상으로 수행하였으며, 시험 항목은 역률, 파고율, 전류 고조파함유율이다. 연구결과: 역률은 모든 시료가 0.4~0.6사이의 값을 나타내어 KS기준에서 정한 0.9이상 보다 작은 값을 보였다. 파고율은 대형의 경우 3.6~3.7 정도의 값을 나타냈으며, 중형은 4.4~4.7, 소형은 3.5~3.7사이의 값을 나타내었다. KS기준인 1.7이하보다는 2배 이상의 높은 값을 나타냈다. 전류 고조파함유율은 81%~110%의 값을 나타냈으며, KS기준이 20% 이하임을 감안할 때 모든 시료가 KS기준을 상당히 넘어서는 값을 가짐을 확인할 수 있었다. 결론: 파고율과 전류 고조파함유율은 광원의 온도상승과 기기의 소손 등에 영향을 미칠 가능성이 있는 성분이므로 이런 전기적 특성을 KS기준의 범위 안에서 유도등을 개발한다면 유도등의 품질개선과 유지관리에 큰 도움이 되리라 생각된다.

히스토그램 분석을 이용한 콘크리트 구조물의 최대 균열 폭 평가 (Estimation of Maximum Crack Width Using Histogram Analysis in Concrete Structures)

  • 이석민;정범석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.9-15
    • /
    • 2019
  • 본 연구의 목적은 영상 처리 기법의 히스토그램 분석을 이용하여 콘크리트 구조물 표면의 최대 균열 폭을 평가하는 것이다. 이를 위하여 콘크리트 표면 균열에 대한 영상을 촬영하고, 촬영된 영상을 회색 영상 및 이진화 영상으로 변환하였다. 이진화된 영상은 팽창과 침식이 적용된 후 레이블링을 통하여 분리된 객체로 인식된다. 콘크리트 표면은 시간이 경과함에 따라 먼지와 얼룩 등이 발생될 수 있으며, 촬영 조건에 따라 그림자 및 조명 반사가 포함될 수 있다. 또한, 콘크리트 균열은 연속적인 형상으로 발생되는 반면에 잡음은 점의 형태로 나타난다. 이러한 영향을 제거하기 위하여 이진화 과정은 양방향 블러와 적응적 경계를 적용하였으며, 레이블링된 영역에 대하여 면적비를 통한 잡음 제거를 수행하였다. 잡음이 제거된 각각의 균열 객체는 히스토그램 분석을 통하여 x축과 y축에 대한 최대값 및 그 위치가 연산되고, 분리된 객체에 대한 각각의 최대값 위치에서 삼각비를 통하여 균열 폭을 평가하게 된다. 제안된 방법에 의해 평가된 최대 균열 폭은 균열 게이지에 의해 계측된 값과 비교 분석되었다. 본 연구에 의해서 제안된 방법은 콘크리트 표면 영상에 대한 균열 폭 평가에 신뢰성을 향상 시킬 수 있을 것이다.

공공의료시설에 적합한 신재생에너지시스템의 복합적용비율에 관한 연구 (A Study on the Application Ratio by the New and Renewable Energy Systems Fit for Public Medical Facilities)

  • 홍준호;이용호;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.32-43
    • /
    • 2014
  • This study set out to identify the importance of each factor influencing facility selection with a survey among public medical facilities under the category of public buildings and apply the importance of economy, technology and environment with the weighting factor method, thus proposing optimal application plans. The research content of each section can be summarized as follows:1) Estimated energy consumption according to the energy simulation was 65,129MWh/yr, which was 18.7% higher than that according to the calculation equation. Of the energy consumption, more than 80% was used by heating and cooling facilities and construction facilities, and 20% was used by electronics such as medical equipments and in and outdoor lighting. 2) The results of a survey on the factors influencing the importance when selecting a new and renewable energy system reveal that the upper items had a priority in economy, environment, and technology in the descending order and that the lower item shad a priority in initial investments, maintenance and repair costs=energy costs, supply reliability, energy efficiency and $CO_2$ emissions in the descending order. 3) The application alternatives were analyzed in economy, technology, and environment. As a result, a geothermal system turned out to be the most excellent one a cross all the upper and lower comparison items. Of the other systems, a solar thermal system was superior in initial investments, maintenance and repair costs, and energy efficiency, where as a photovoltaic system was superior in energy costs, supply reliability, and $CO_2$ emissions. 4) As for the mixed application ratio among economy, technology, and environment, when the percentage of a geothermal system was approximately 80% or higher in anew and renewable energy system, it was the best and most optimal application plan.

역사문화경관 보전을 위한 경관협정 항목에 관한 연구 (A Study of the Landscape Agreement Project for Historical and Cultural Landscape Preservation)

  • 신민지;신지훈
    • 한국조경학회지
    • /
    • 제41권6호
    • /
    • pp.129-139
    • /
    • 2013
  • 본 연구는 지역의 경관관리를 위해 경관협정이 많이 이루어지고 있는 현 시점에 역사문화경관을 보전하기 위한 방안으로 경관협정을 제시하고자 하였으며, 경관협정의 내용이 포괄적이고 광범위한 내용으로 구성되어 있는 문제점 및 경관유형에 따른 경관관리 방법과 경관협정내용의 일반화가 필요하다는 문제에서 진행되었다. 이를 위해 역사문화경관 보전 관련 가이드라인 고찰 및 주민자치 및 참여에 의한 경관관리가 이루어지고 있는 국 내외 지역 사례 등을 고찰하여 도출된 항목들을 통해 지역민이 직접 참여하여 스스로 지킬 수 있는 지속적이고 실효성 있는 경관관리방법을 제안하고자 하였다. 역사문화경관 보존을 위해 지역 주민이 자발적으로 지키는 것이 바람직한 것으로 판단되는 경관협정 항목으로는 역사문화경관 주변의 조성에 있어 건축물 외형 및 외부공간 등이 역사문화경관을 모티브로 하여 접근성과 상징성이 나타나도록 조성할 것으로 고려해야 하며, 가로환경에서 보행 친화적인 환경을 유지하기 위해 옥외광고물 및 시설물의 유지관리에 주의를 기울이고, 기존의 역사문화경관과 조화로운 디자인을 추구하는 것을 제안하였다. 중요도가 낮아 필요시 포함될 수 있는 사항으로 제안할 수 있는 내용은 건축물의 규모를 제한하고, 건축설비시설의 은폐 및 집약화로 노출을 막는 세부 사항과 외부공간의 유지관리, 자연친화적인 재료의 사용 및 야간경관의 네온표지판관리 및 야간조명시간 운영에 대한 사항 등으로 나타났다. 연구 결과를 통해 전통성이 나타나는 역사문화경관의 경관관리를 위해 지역민이 스스로 추진하여 경관향상 및 지역민의 경관에 대한 의식의 전환을 기대할 수 있는 것으로 판단된다.

대형 푸드코트 이용 고객들의 서비스 인카운터 중요도-실행도(IPA) 분석 평가 연구 (A Study on Customer Service Encounters at a Large Food Court Customer Using Importance-performance Analysis)

  • 윤혜려
    • 한국식품영양학회지
    • /
    • 제21권1호
    • /
    • pp.97-105
    • /
    • 2008
  • An IPA model was used to evaluate customer service encounters at a large food court; also the gaps between importance and performance from were also evaluated from both perspectives. The findings of this study will be applied in order to improve service quality at various large food service operations. A total of 298 customers from a large shopping mall food court completed the study questionnaire, asking them to evaluate the important and performance attributes of service. Seven underlying dimensions were identified and labeled by factor analysis: factor 1 was "safety": factor 2 "time": factor 3 "atmosphere": factor 4 "quality of food": factor 5 "menu attributes": factor 6 "comfort": and the last and seventh factor was "comprehension". As a result of IPA analysis the overall mean scores between the importance attributes and performance attributes showed significant differences by independent t-tests(p<0.001). Quadrant I was classified with unnecessary items including interior design, proper lighting, suitable chairs, and proper room temperature. In quadrant II thirteen variables showed high scores for both importance and performance, such as various menu choices, hygienic food, dishes, chairs, food court, kitchen, and employees; proper ventilation, employee kindness, waiting time to order, and received food; automatic system for ordering-serving. Quadrant III included eight variables identified as low priority, including appearance of food, nutrient content of food, proper portions, new menu, proper music, proper location of cashier, services for children and efficiency of movement. In quadrant IV six variables were included as areas to focus management's efforts, such as food taste, proper food temperature, use of safe food materials, maintenance of food quality, existence of preferred foods, and proper food prices. These results suggest that food court customers have interests that are distinct from restaurant customers and may need to be treated differently. It is anticipated that this data will be useful to the foodservice industry in order to segment customer characteristics by different dinning behaviors.

기업체 복지시설의 실내디자인 방향에 관한 연구 -직원식당을 중심으로- (A Study on the Direction of the Interior Deisgn of Welfare Facility -Focus on Cafeteria for Employee-)

  • 오도엽
    • 한국실내디자인학회논문집
    • /
    • 제17호
    • /
    • pp.22-29
    • /
    • 1998
  • As the trend shows that corporate investment for staff's welfare facilities has increased alongside employee's enhanced economic and conscious level which has resulted from economic growth and industrialization this study aims at analyzing interior design elements in staff's welfare facilites especially in cafeteria and suggesting new directions for designing those spaces. The method and scope of this study in firstly to described general points such as function and role of public food service and interior design elements in staff's cafeteria and then to grasp and analyze the present conditions of the staff's cafeteria for enterprises and financial organizations which has been built after 1990. The conclusion of his study can be summarized as follows : First it is desirable to locate employee's cafeteria on upper or top floor which has relatively good atmosphere. Second it is recommended to make overall atmosphere of employee's cafeteria impressive and in commercial restaurant. Third the separation of service circulation serveries and eating area is necessary. Fourth material for each parts should be easy to maintain and durable. Fifth more illuminance that the regulation is recommended and lighting fixture should be selected in terms of economics and maintenance. Sixth selecting bright and warm colors with partial application of accent colors is effective. Seventh furniture should be harmonized with the ambience of the space and required to be convenient and durable. Eighth to provide visual and auditory pleasure during eating it is desirable to equip the minimal A/V system. In addition diverse aspects such as improving employee's welfare caring for company the way of treating employee an boosting corporate images should be considered when designing staff's cafeteria and interior designer should be able to satis managerial aspects productivity and effectiveness as well as pursuing functional aesthetic facts.

  • PDF

고령사회를 대비한 노인운전자 교통사고 특성 및 저감방안 -제주지역을 중심으로- (The Characteristics of Traffic Accidents and Reduction Methods by Elderly Drivers to Prepare for the Aging Society -Focused on Jeju-)

  • 김경범
    • 한국콘텐츠학회논문지
    • /
    • 제14권7호
    • /
    • pp.151-160
    • /
    • 2014
  • 본 연구의 목적은 노인운전자의 교통사고 유형과 특성 등을 분석하여 교통사고 저감방안을 도출하고, 향후 노인을 위한 실제적인 교통안전정책의 방향 수립에 있다. 노인운전자의 교통사고 실태를 분석한 결과, 노인운전자에 의한 교통사고는 조명시설 등 교통안전시설물 설치가 열악한 도시 외곽지역인 지방도에서 빈번하게 발생하고 있으며, 가장 많이 발생하는 시간대는 18~20시 사이로 태양빛이 사라지고 어둠이 드리우는 일몰시간대로 나타났다. 안전운전의무 불이행과 같은 주의력 부족에 의한 교통사고가 많이 발생하였다. 노인운전자에 의한 교통사고 감소뿐만 아니라 우리 사회 전체의 안전을 위해서는 교통약자인 노인을 배려하는 법제도의 개선과 지역특성을 고려한 도로안전시설물 등의 정비가 필요하며, 신체적 능력이 저하된 노인운전자는 자신 스스로가 자신의 운전능력을 의심하고 테스트할 수 있는 신뢰 기재인 면허갱신제도 등에 의한 테스트와 대체교통수단 이용을 통한 직접 운전수요를 감소시키려는 노력이 필요하다.

무인감시설비 유지보수를 위한 자동점검시스템 설계 (Design of Automatic Inspection System for Maintenance of Unmanned Monitoring Facility)

  • 문채영;김세민;류광기
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 춘계학술대회
    • /
    • pp.515-517
    • /
    • 2018
  • 변전소, 댐, 철도 등과 같은 공공시설들의 출입은 매우 엄격하제 관리되어 있으며 최근에는 IT기술의 발전과 정부의 비용절감정책으로 무인감시설비가 도입되어 운영되고 있다. 그러나 무인감시설비에 고장이 발생되면 감시 공백과 침입자에 의한 정보유출과 시설파손 등의 피해가 발생할 수 있다. 또한 감시설비의 점검을 위해서는 관리자의 주기적 방문점검이 필요하며 이로 인해 추가적인 관리비용이 발생되는 문제점을 갖고 있다. 이를 해결하기 위해 본 논문에서는 무인감시설비의 동작 상태를 실시간 점검하여 문제 발생 시 자동복구를 시도하고 관리자에게 이를 통보하는 시스템을 설계하였다. 설계된 시스템은 영상, 음향, 조명 상태 등의 정보를 수신하고 판단하는 NVR과 무인감시설비의 상태를 감지하고 복구를 시도하는 제어장치로 구성되어 있다. 본 논문에서 제안된 시스템을 이용하여 무인감시설비의 고장으로 인한 감시공백 최소화와 점검비용의 감소로 인한 경제성 향상에 기여할 것으로 기대된다.

  • PDF

공공임대주택 유형별 부재의 사후보전 수선시기 설정연구 (Analysis of the Breakdown repair time of the Building Components in Public Rental-Housing Types)

  • 이강희;안용한;채창우
    • KIEAE Journal
    • /
    • 제13권6호
    • /
    • pp.129-136
    • /
    • 2013
  • The rental housing has played a key role to supply a decent living space for the low-income households. The owner of the rental housing should maintain and manage the building physical condition. On the other hand, rents should use the housing without any damage and pay a certain fare for the rent. A rent is classified into two types : private and public. The public rent is mainly to supply a living space for non-available home owner with a low-rent fare. Many of public rent are built and supplied by the public institution or local government. The supplier would take a responsibility to maintain the building and components, reflected by the maintenance plan and repair scope. In this paper, it aimed at providing the repair time in building components of the public rental housing such as lighting, electrical cable, paintings and etc.. The repair time is analyzed with three calculation methods which are solved by the probability and empirical approach. Results are as follows : First, the repair time of the electrical facilities are maintained with 11yr, 10yr and 7 in permanent, public and redevelopment rent respectively. The roof proof has a repair time with 14yr, 11yr and 8 in permanent, public and redevelopment rent housing respectively. Second, Most of the components has a prior length of the repair time in permanent, public and redevelopment rent sequently. There is a difference in repair time according to the rental types. Therefore, it would continue to research the difference in aspect of the living style, building physics, living consciousness and etc.