• Title/Summary/Keyword: Lighting Direction

Search Result 145, Processing Time 0.023 seconds

A Study on the Change of Exclusive Space for Balcony Expansion in an Apartment - Focused on an Apartment House below 85m2 of Exclusive Area- (아파트 발코니 확장에 따른 전용공간의 변화에 관한 연구 - 전용면적 85m2형 공동주택을 대상으로 -)

  • Bae, Dong-Sig
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.2
    • /
    • pp.11-18
    • /
    • 2018
  • The purpose of this study is to analyze the structure and use change of the private space according to the balcony expansion and use it as the data of plan design. According to Bay, front length/width ratio and the change of balcony space before and after expansion of space organization of house units were analyzed. Common characteristics of Flat type and Tower type are an increase of the frontage length of house units in an apartment, an increase of the number of front bay, and an increase of integrated LDK focusing on living room. A difference is that Flat type shows high frontage ratio, Bay figure, and spatial arrangement favorable to front openness and lighting. Flat type shows higher area distribution than Tower type in LDK area distribution located in at the plane center. Spatial expandability and visual openness of Flat type are more beneficial than those of Tower type in the planning, and a balcony extension of house units has developed to direction to open more. Tower type creates various block images through a combination of house units focusing on the core. Uses after balcony expansion are area expansion of a balcony-neighboring room, storage space, expansion and function improvement of the variable range, and specialized space different from a neighboring room. In addition, there is no escapable space except for a shelter, so unit plan should be prepared to prevent using it other space of a shelter and to solve moving line of two-way horizontal refuge and vertical refuge.

Real-time Intelligent Exit Path Indicator Using BLE Beacon Enabled Emergency Exit Sign Controller

  • Jung, Joonseok;Kwon, Jongman;Jung, Soonho;Lee, Minwoo;Mariappan, Vinayagam;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Emergency lights and exit signs are an indispensable part of safety precautions for effective evacuation in case of emergency in public buildings. These emergency sign indicates safe escape routes and emergency doors, using an internationally recognizable sign. However visibility of those signs drops drastically in case of emergency situations like fire smoke, etc. and loss of visibility causes serious problems for safety evacuation. This paper propose a novel emergency light and exit sign built-in with Bluetooth Low Energy (BLE) Beacon to assist the emergency self-guiding evacuation using devices for crisis and emergency management to avoid panic condition inside the buildings. In this approach, the emergency light and exit sign with the BLE beacons deployed in the indoor environments and the smart devices detect their indoor positions, direction to move, and next exit sign position from beacon messages and interact with map server in the Internet / Intranet over the available LTE and/or Wi-Fi network connectivity. The map server generate an optimal emergency exit path according to the nearest emergency exit based on a novel graph generation method for less route computation for each smart device. All emergency exit path data interfaces among three system components, the emergency exit signs, map server, and smart devices, have been defined for modular implementation of our emergency evacuation system. The proposed exit sign experimental system has been deployed and evaluated in real-time building environment thoroughly and gives a good evidence that the modular design of the proposed exit sign system and a novel approach to compute emergency exit path route based on the BLE beacon message, map server, and smart devices is competitive and viable.

Robust Estimation of Camera Motion Using A Local Phase Based Affine Model (국소적 위상기반 어파인 모델을 이용한 강인한 카메라 움직임 추정)

  • Jang, Suk-Yoon;Yoon, Chang-Yong;Park, Mig-Non
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.1
    • /
    • pp.128-135
    • /
    • 2009
  • Techniques for tracking the same region of physical space with the temporal sequences of images by matching the contours of constant phase show robust and stable performance in relative to the tracking techniques using or assuming the constant intensity. Using this property, we describe an algorithm for obtaining the robust motion parameters caused by the global camera motion. First, we obtain the optical flow based on the phase of spacially filtered sequential images on the region in a direction orthogonal to orientation of each component of gabor filter bank. And then, we apply the least squares method to the optical flow to determine the affine motion parameters. We demonstrate hat proposed method can be applied to the vision based pointing device which estimate its motion using the image including the display device which cause lighting condition varieties and noise.

Study of a Photovoltaic System as an Emergency Power Supply for Offshore Plant Facilities (해양플랜트 설비의 비상전원공급을 위한 태양광 발전시스템 연구)

  • Choi, Gun Hwan;Lee, Byung Ho;Jung, Rho-Taek;Shin, Kyubo
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.279-286
    • /
    • 2018
  • The use of eco-friendly energy in the offshore plant system is expanding because conventional generators are operated by fossil fuel or natural gas. Eco-friendly energy, which replaces existing power generation methods, should be capable of generating the power for lighting protection equipment, airborne fault indication, parameter measurement, and others. Most of the eco-friendly energy used in offshore plant facilities is solar and wind power. In the case of using photovoltaic power, because the structure must be constructed based as flat solar panels, it can be damaged easily by the wind. Therefore, there is a need for a new generation system composed of a spherical structure that does not require a separate structure and is less influenced by the wind. Considering these characteristics, in this study we designed, fabricated, and tested a unit that could provide the most efficient spherical photovoltaic power generation considering wind direction and wind pressure. Our test results indicated that the proposed system reduced costs because it did not require any separate structure, used eco-friendly energy, reduced carbon dioxide emissions, and expanded the proportion of eco-friendly energy use by offshore plant facilities.

Face Recognition Using Fisherface Algorithm and Fixed Graph Matching (Fisherface 알고리즘과 Fixed Graph Matching을 이용한 얼굴 인식)

  • Lee, Hyeong-Ji;Jeong, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.6
    • /
    • pp.608-616
    • /
    • 2001
  • This paper proposes a face recognition technique that effectively combines fixed graph matching (FGM) and Fisherface algorithm. EGM as one of dynamic link architecture uses not only face-shape but also the gray information of image, and Fisherface algorithm as a class specific method is robust about variations such as lighting direction and facial expression. In the proposed face recognition adopting the above two methods, linear projection per node of an image graph reduces dimensionality of labeled graph vector and provides a feature space to be used effectively for the classification. In comparison with a conventional EGM, the proposed approach could obtain satisfactory results in the perspectives of recognition speeds. Especially, we could get higher average recognition rate of 90.1% than the conventional methods by hold-out method for the experiments with the Yale Face Databases and Olivetti Research Laboratory (ORL) Databases.

  • PDF

An Analysis of Long-Term Variation of PM10 Levels and Local Meteorology in Relation to Their Concentration Changes in Jeju (제주지역 미세먼지의 장기변동 및 농도변화에 관한 국지기상 분석)

  • Park, Yeon-Hee;Song, Sang-Keun;Lee, Soo-Jeong;Kim, Suk-Woo;Han, Seung-Bum
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.107-125
    • /
    • 2016
  • Long-term variations of $PM_{10}$ and the characteristics of local meteorology related to its concentration changes were analyzed at 4 air quality sites (Ido-dong, Yeon-dong, Donghong-dong, and Gosan) in Jeju during two different periods, such as PI (2001-2006) and PII (2007-2013), over a 13-year period. Overall, the long-term trend of $PM_{10}$ was very slightly downward during the whole study period, while the high $PM_{10}$ concentrations in PII were observed more frequently than those in PI. The concentration variations of $PM_{10}$ during the study period was clarified in correlation between $PM_{10}$ and meteorological variables, e.g. the low (high) $PM_{10}$ concentration with large (small) precipitation or high (low) radiation and in part high $PM_{10}$ concentrations (especially, Donghong-dong and Gosan) with strong wind speed and the westerly/northwesterly winds. This was likely to be caused by the transport effect (from the polluted regions of China) rather than the contribution of local emission sources. The $PM_{10}$ concentrations in "Asian dust" and "Haze" weather types were higher, whereas those in "Precipitation", "Fog", and "Thunder and Lighting" weather types were lower. The contribution of long-range transport to the observed $PM_{10}$ levels in the urban center (Ido-dong, Yeon-dong, and Donghong-dong), if estimated by comparison to the data of the background site (Gosan), was found to explain about 80% (on average) of its input.

A Study on the Improvement Direction through the Present Status of Nursing Home - Focus on the Nursing Home in Chungcheongbuk-do - (노인요양시설의 건축현황 및 개선방향에 관한 연구 - 충청북도 노인요양시설을 중심으로 -)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.242-250
    • /
    • 2010
  • Recently, the long-term care insurance for the elderly was carried out according to the elderly is increased rapidly and the formation of sympathy that a nation and society try commonly to share health and welfare promotion of the elderly. The purpose of this study is to analyze the present status of nursing home after that the long-term care insurance is enforced in chungcheongbuk-do and to utilize as basic data. The study limited its survey to those facilities that refer to the Ministry of Health and Welfare data, that had the capacity of more than 50 people. The result are as followings. Firstly, most of the nursing home were located on the outskirts of the city. But it must be constructed in the city center if the recent deinstitutionalization trend is reflected. Secondly, notwithstanding the provisions of the Elderly Welfare Law, if the Livability and amenity are considered, the plan of a single or a twin room is needed. The ondol(溫突) system bedroom for the safety of the elderly had to be planned and for the color planning of a bedroom, a heating, the furniture, the form of a door, corridors, etc. should be partly improved. The fastener in which it is appropriate for the main exit, a stair, an elevator, the lighting device, and etc. is needed and the installation of a wandering path for the dementia patient and etc. is required. Thirdly, most of the dining room arranged on the first floor but it is not nearly used and it used for employee or the other use. Therefore, we have to consider the system in which it can deliver the meal to a bedroom. If the smell of the elderly and etc. is considered, the sufficient height of the floor should be reflected for the ventilation equipment. Lastly, The improvement of the existing law are required.

A study on the work in fishing convention, 2007 and the fishing vessel's accommodation facilities standards in national fishing vessel act (ILO어선원노동협약과 어선법의 어선거주설비에 대한 고찰)

  • Kim, Wook-Sung;Park, Moon-Gap
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.466-475
    • /
    • 2010
  • This study intends to present a direction for the better reforming of fishers'onboard living conditions and proposals for preparing for ratification of the Work in Fishing Convention by means of making a comparison between standards on recent national fishing vessel accommodation facilities and standards on the Work in Fishing Convention and Its Recommendation, 2007, ILO. For the most part of standards on national fishing vessel accommodation facilities are somewhat insufficient to satisfy the provisions in Annex III of the Convention. Considering by items on fishing vessel accommodation facilities, the standards on insect protector, noise and vibration, heating and air conditioning, lighting, persons per sleeping room, recreational facility are not provided in national law. Headroom, separation of accommodation, sleeping room floor area, mattress size, mess room, galley and food storage are partially sufficient for the Convention. In case of sanitary facilities, national standards are not sufficient for the Convention. The other side, facilities related safety of ship and crew such as emergency escape etc., are fully sufficient for the Convention. These insufficiencies caused by different types of fishing vessel depend on originality of fishing method and practices. In the comparison between equivalent tonnage about vessel's length on convention and calculated tonnage of national existing fishing vessel, the difference are 226tons about length 24m and 501tons about length 45m. For that reason, headroom, persons per sleeping room, cabin of sicker and injured, sanitary facilities may decide to use gross tonnage in place of length (L) and the alleviating measure basis of convention. But in case of standards on sanitary facilities which are unsufficient for the Convention, specially in coastal fishing vessel length basis should be adopted with alleviating basis for less than length 24m.

GIS Application for Site Planning

  • Han, Seung-Hee;Lee, Jin-Duk
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • The general urban plan is the plane plan which limits general and uniformed constructions; however, the district unit plan is the solid plan that can leads various constructions by discriminating by plot, housing area and lot. Therefore, for the zone plan, not only the two-dimensional plot information such as plot usage plan, but also the three-dimensional plot information needs to be used to analyze lighting, sewerage and directions. To fulfill such requirements, the information can be gathered using GIS and photogrammetric method for the reasonable and efficient zone plan. In this research, the information about the testing area for the zone plan has been gathered using GIS method, and the three-dimensional model about the area has been built using the satellite image and DEM. As the result, plot usage analysis, direction analyst, water system analysis, and slope analysis has been done and used efficiently to build the district unit plan. Also, after the result after applying the analyzed result to the actual area says this is very appropriate and efficient.

  • PDF

A Study on the Comparative Analysis and Improvement of Indoor Environmental Factor in Green Building Rating Systems (국내외 친환경건축물 인증제도 실내 환경 관련 부문 비교분석 및 개선안 연구)

  • Joh Hahn
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.21-28
    • /
    • 2006
  • To promote environmentally responsible architectural practice, many nations have established their own green building rating system. Among other criteria, recently the indoor environmental quality section has been paid great attention due to Sick Building Syndrome, as this believed to caused by polluted indoor environment. In this context, indoor environmental quality is one of very important sections of each green building rating system and closely related to the very happiness of building users. The goal of this research is to compare and analyze the indoor environmental sections of three green building rating systems, GBCC, LEED v2.1, and BREEAM Office 2005, and find a direction for the improvement of GBCC. First, the three rating systems are analyzed in general to compare the importance of indoor environmental factors in each system. Second, the indoor environmental factors are reclassified within related sub-categories for the comparable analysis. Finally, based upon the comparable analysis, directions for the improvement of GBCC are as follows: 1. GBCC's h4r Environment Section needs to clarify its VOCs criteria based upon types of finish materials. 2. Sound Environment Section's noise control criteria needs to be revised based upon types of building usages and application method. 3. An indoor lighting related section needs to be included in GBCC, as even though light is the one of the most important factors in indoor environment, it has not been included in GBCC yet. 4. The sub-section of Confortable Indoor Environment Section related to the resting space and the universal accessibility are not in accord with the goal of green building rating system. These items need to be dealt within general building codes. 5. The rating evaluation structure and process need to be streamlined.