• 제목/요약/키워드: Lighting Design Simulation

검색결과 134건 처리시간 0.032초

터널의 가시성 개선을 위한 Counter-beam 효과 연구 (The Contrast Analysis of Counter-beam for Tunnel Visibility)

  • 이영규
    • 한국산업정보학회논문지
    • /
    • 제6권1호
    • /
    • pp.77-81
    • /
    • 2001
  • 도로의 가시성(Visibility)은 운전자에게 매우 중요하다. 특히 차량이 터널을 통과할 때의 가시성은 더욱 중요한데, 터널내의 조명은 운전사의 가시성에 많은 영향을 미친다. 이러한 가시성 향상을 위하여 새로운 터널조명 방식인 Counter-beam 조명이 유럽과 일본을 중심으로 최근 소개되고 있다. 본 논문에서는 터널조명 발전을 위한 새로운 접근 방법론을 제시하고 기본적인 상황에서 Counter-beam 조명의 효과를 Simulation을 통하여 분석하고 평가함으로써 그 적용 가능성을 알아본다.

  • PDF

TRIAC 디밍제어방식을 적용한 실내 LED 조명기기의 전도성 잡음 저감에 관한 연구 (A Study on the Reduction of Conducted Noise Emission from an Interior LED Lighting Module with TRIAC Dimming Control)

  • 서정남;유용수;여인선
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.109-113
    • /
    • 2011
  • This paper analyzes the noise sources of an LED lighting module with TRIAC dimming control and proposes an improved EMI filter design for the reduction of conducted noise emission. TRIAC dimming invokes problems of input oscillation and capacitor overvoltage at the lighting module. The proposed double LC filter reduces high noise level from the circuit. The experimental and simulation results show that this approach can make significant contributions to the reduction of conducted noise emission from an LED lighting module with TRIAC dimming control.

알고리듬 변화에 따른 직/간접 조명시스템에 대한 디밍제어 효과분석 (Analysis on Dimming Control Effect by Algorithm Variation for Direct/Indirect Lighting in a Small Office)

  • 김수영
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.36-48
    • /
    • 2008
  • This study examines the influence of control algorithms on dimming performance to determine appropriate control setting when direct/indirect lighting is controlled by a daylight dimming system. Computer simulation were performed for a small office with double skin envelope under various daylight conditions. A retractable fabric shading and Venetian blind were applied for internal and external envelopes under three CIE standard sky conditions. Unshielded and partially-shielded photosensors were used, and three control algorithms were applied for the sensors. In general, dimming level was too excessive due to the direct impact of light from lighting fixture to the photosensor. Providing insufficient lighting output, the unshielded photosensor completely failed to secure required illuminance under any daylight condition. When a partially-shielded photosensor was applied under clear sky, three setting points functioned effectively. Less sensitivity for the partially-shielded photosensor was effective to control the dimming system optimally with reasonable energy saving. However, the daylight dimming control system for direct/indirect lighting does not appear to be energy effective when photosensors without enough shielded area is installed on ceiling where light from fixtures reaches directly.

G/T 199톤급 우리나라 대형선망 등선 겸용 운반어선의 선형설계에 관한 연구 (A Study on the Hull Form Design of a G/T 199ton Class Fishing Boat for Both Fish-luring Lighting and Fish Carrying in Korean Large Purse Seiner Fishing System)

  • 박애선;이영길;진송한
    • 대한조선학회논문집
    • /
    • 제49권5호
    • /
    • pp.391-399
    • /
    • 2012
  • This paper presents a method of hull form design for the assistant vessel which is used both as a lighting boat and a fish carrying boat for the fleet of newly formated purse seiner vessels. The optimum hull form parameters are searched by the Sequential Quadratic Programing(SQP) method with the power estimation method of Van Oortmerssen. The prismatic curve is redesigned from that of the reference hull by the Lackenby method. Through the modification of the hull form by using a CAD system, the design procedure is completed. The resistance performances of the reference and the modified hull forms are estimated by using a numerical simulation method. Also, the estimation of seakeeping ability and stability for the modified hull forms are carried out. And then, an optimum hull form is proposed for the designed hull form. Ship model tests for the reference and the designed hull forms are carried out at ship model basin. The results of the experiments show that the effective horse power of the designed hull form is about 22% smaller than that of the reference hull form at design speed. The designed hull form proposed in this study will contribute to the development of the hull form for Korean large purse seiner vessels.

보안설비의 적정관리를 위한 조명개선 (Lighting Improvement for Propriety Management of Security Installations)

  • 이개명;오성보
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1370-1374
    • /
    • 2015
  • 보안구역 내의 외곽울타리지역의 경비체제를 인적경비에서 과학화경비로 전환함에 따라 안정된 보안설비의 적정관리를 위한 조명개선이 요구되어진다. 본 논문에서는 효율적인 외곽 감시를 수행할 수 있도록 경비과학화시스템에 적합한 등기구 선정과 균일한 조도환경을 조성하기 위하여 조명설비의 부적절한 적용으로 모니터에 눈부심이 심한 울타리 지역을 선정하여 LED 등의 용량을 변화시키며 등기구의 각도, 등주간의 거리, 등기구의 취부높이 등의 조정에 따른 현장 모의실험으로 감시모니터에 발생하는 눈부심을 해소시키고자 하였다. 또한 모의실험 조건에 따른 CCTV 화면분석과 조도값을 바탕으로 공항 외곽지역과 유사한 조건으로 조명 모델링하고 소비전력이 다른 LED 광원을 이용한 시뮬레이션 실시로 공항 외곽보안설비의 적정운영 위한 조명설계안을 제시하고자 한다.

250 W급 LED가로등의 배광 최적설계에 관한 연구 (A Study on the Lighting Distribution Optimal Design of 250 W LED Streetlight)

  • 신왕수;이승민;권영국;이진열;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.408-413
    • /
    • 2015
  • Road lighting has emerged in importance as an essential system to secure safety and visibility for drivers and pedestrians. According to the Road Lighting Standards (KS A 3701), the luminance uniformity (U0) should be 0.4, the luminance uniformity for lanes (UI) should be 0.5, and a threshold increment (TI) of 10% should be satisfied. In this study, we conducted simulations using the Relux program in which the secondary optical lens was applied to a 21 W engine. Ten LED engines were installed on a two-way four-lane road, and the simulation result satisfied the requirements with U0 0.47, UI 0.63 and TI 8%. The U0, UI, and TI were compared with the angle of the LED streetlight varied in the range of $9^{\circ}{\sim}15^{\circ}$ with $0.5^{\circ}$ intervals. The range was selected as ${\pm}25%$ of the standard inclination angle of $12^{\circ}$ according to the Road Lighting Standard. The U0 was high and the UI and TI were low when the tilting angle was in the range of $9.5^{\circ}{\sim}10.5^{\circ}$. Consequently, an optimum-design of lighting distribution was obtained for the concrete two-way four-lane road when the inclination angle was $9^{\circ}$.

Thermal Characteristics of the Optimal Design on 20W COB LED Down Light Heat Sink

  • Kwon, Jae-Hyun;Lee, Jun-Myung;Huang, Wei;Park, Keon-Jun;Kim, Yong-Kab
    • International journal of advanced smart convergence
    • /
    • 제2권2호
    • /
    • pp.19-22
    • /
    • 2013
  • As the demand of the LED for lighting that emits light by p-n junction is increasing, studies on heatproof plate technology is being conducted to minimize the temperature of the LED lighting. As for the temperature of the LED devices, their light emitting efficiency decreases and the maximum lifespan drops down to 1/5. Therefore there are heat dissipation studies going on to minimize the heat. For LED heat dissipation, aluminum heat sink plates are mostly used. For this paper, we designed heat sink that fits residential 20W COB LED Down Light; packaged the heat sink and 20W COB and analyzed and evaluated the thermal properties through a Solidworks flow simulation. We are planning to design the optimal heat sink plate to solve the thermal agglomeration considering TIM(Thermal Interface material).

LED조명용 비구면 Plastic Lens의 성능향상을 위한 광학설계 (Optical Design considering Efficiency Improvement of Aspheric Plastic Lens for LED Lighting)

  • 이학석;박종락;김민재;김혜정;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.289-289
    • /
    • 2009
  • Light emitting diode(LED) has many advantages including lower energy consumption and longer lifetime and eco-friendly in comparison with traditional light sources. Spheric plastic lens generally used in LED lighting occurs aberration and ghost image which give displeasure and deteriorate vision quality in human eyes. Using the optical program (LightTools$^{TM}$, CodeV$^{TM}$), we were confirm the aberration and ghost image in optical simulation and employed aspheric lens form in the lens design to improve these problems. From the comparison of the simulation results between the aspheric lens and the spheric lens, we were ascertain to be improved both aberration and Ghost image.

  • PDF

100 W급 LED 보안 등기구용 비대칭 배광의 2차 렌즈 설계 (Secondary Optics Design of Dissymmetrical Light Distribution for 100 W LED Safety Luminaires)

  • 신익태;양종경;이동진;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제23권6호
    • /
    • pp.471-476
    • /
    • 2010
  • This paper has studied dissymmetrical light distribution design using the secondary optics in the simulation. fundamental Lambertian radiation distribution based on LED has been cut off by the secondary optics, and the first surface slope of lens and second surface slope of total reflection area have been calculated through formula. PMMA (the index of refraction: 1.49361) which is material of lens has been selected. critical angle($42.02993^{\circ}$) between Air and PMMA has been calulated by snell's law, and total reflection angle slope has been selected about $16.67^{\circ}$ to occur the total reflection. when the first surface slope and the second surface slope has been set up, Rays of all total reflection area have generated the total reflection. finally, designed LED Module has been estimated by Korean Industrial Standards for LED safety street lighting. dissymmetrical light distribution have been analyzed with reached effect of road illuminance, and average road illuminance which are each 70.6 lx, 40.35 lx, and 25.88 lx have been satisfied with Korean Industrial Standards for LED safety street lighting.

LED 프리즘 조명기구의 광학설계를 위한 조명광학설계 소프트웨어 비교 연구 (A Study on the Comparison of the Optical Design of LED Prism Luminaires from Lighting Optical Design Softwares)

  • 김유신;유민정;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.15-18
    • /
    • 2009
  • Photopia, LightTools, and ASAP are typical software for optical design of a luminaire. Through using various lighting simulation software some different results can be found under the same conditions. Therefore, the purpose of this paper is to compare simulated photometric data and values illuminance of different types of LED prism luminaires under the same conditions. Then, LED prism luminaires were divided into the linear type and the planar type. Also three kinds of prism angles were divided into $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$. In addition, the reasons for such differences were analyzed.

  • PDF