• Title/Summary/Keyword: Light emitting diode (LED)

Search Result 856, Processing Time 0.029 seconds

Fiber-optic Goniometer to Measure Knee Joint Angle for the Diagnosis of Gait Disturbance (보행장애 진단을 위한 무릎관절 각도 측정용 광섬유 각도센서)

  • Kim, S.G.;Shin, S.H.;Jeon, D.;Hong, S.H.;Sim, H.I.;Jang, K.W.;Yoo, W.J.;Lee, B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1009-1013
    • /
    • 2013
  • In this study, we developed a fiber-optic goniometer for the continuous measurement of knee joint angle which provides important medical information on Alzheimer's disease. The fiber-optic goniometer is composed of a light-emitting diode (LED), a plastic optical fiber (POF), and a voltage output photodiode (PD). As a sensing part of the fiber-optic goniometer, a unclad fiber with regular intervals of 1 mm was fabricated to improve efficiency of bending loss according to the angle variation of knee joint. The emitting light with a center wavelength of 470 nm from a LED is guided by a POF to the PD, the transmitted light is then attenuated by the bending loss inside the bent POF. The intensity variation of the light transmitted from the POF gives rise to a change in output voltage in the fiber-optic goniometer. Therefore, we measured the real-time output voltage of the proposed fiber-optic goniometer using the unclad fiber according to the knee joint angle. Through the repeated experiments, the fiber-optic goniometer shows that it has a reversibility and a wide measurable angle range.

Effects of Low-level Light Therapy at 740 nm on Dry Eye Disease In Vivo

  • Goo, Hyeyoon;Kim, Hoon;Ahn, Jin-Chul;Cho, Kyong Jin
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.50-58
    • /
    • 2019
  • Background and Objectives Low-level light therapy (LLLT) is an application of low-power light for various purposes such as promoting tissue repair, reducing inflammation, causing analgesia, etc. A previous study suggested the effect of light emitting diode (LED) light with the wavelength of 740 nm for promoting wound healing of corneal epithelial cells. This current study aimed to confirm the effect of LLLT for managing inflammation of a dry eye disease (DED) mouse model. Materials and Methods A total of 50C57BL/6 female mice were randomly grouped into 5 groups to compare the effect of LLLT:1) Control group, 2) Only LLLT group, 3) Dry eye group, 4) LLLT in dry eye group, and 5) Early treatment group. DED was induced with 4 daily injections of scopolamine hydrobromide and desiccation stress for 17 days, and LLLT at 740 nm was conducted once every 3 days. To analyze the effect of LLLT on the DED mouse model, tear volume, corneal surface irregularities, and fluorescence in stained cores were measured, and the level of inflammation was assessed with immunohistochemistry. Results The DED mouse model showed significant deterioration in the overall eye condition. After LLLT, the amount of tear volume was increased, and corneal surface irregularities were restored. Also, the number of neutrophils and the level of inflammatory cytokines significantly decreased as well. Conclusion This study showed that LLLT at 740 nm was effective in controlling the corneal conditions and the degree of inflammation in DED. Such findings may suggest therapeutic effects of LLLT at 740 nm on DED.

Effect of Si-doping on the luminescence properties of InGaN/GaN green LED with graded short-period superlattice

  • Cho, Il-Wook;Lee, Dong Hyun;Ryu, Mee-Yi;Kim, Jin Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.280.1-280.1
    • /
    • 2016
  • Generally InGaN/GaN green light emitting diode (LED) exhibits the low quantum efficiency (QE) due to the large lattice mismatch between InGaN and GaN. The QE of InGaN-based multiple quantum wells (MQWs) is drastically decreased when an emission wavelength shifts from blue to green wavelength, so called "green gap". The "green gap" has been explained by quantum confined Stark effect (QCSE) caused by a large lattice mismatch. In order to improve the QE of green LED, undoped graded short-period InGaN/GaN superlattice (GSL) and Si-doped GSL (SiGSL) structures below the 5-period InGaN/GaN MQWs were grown on the patterned sapphire substrates. The luminescence properties of InGaN/GaN green LEDs have been investigated by using photoluminescence (PL) and time-resolved PL (TRPL) measurements. The PL intensity of SiGSL sample measured at 10 K shows stronger about 1.3 times compared to that of undoped GSL sample, and the PL peak wavelength at 10 K appears at 532 and 525 nm for SiGSL and undoped GSL, respectively. Furthermore, the PL decay of SiGSL measured at 10 K becomes faster than that of undoped GSL. The faster decay for SiGSL is attributed to the increased wavefunction overlap between electron and hole due to the screening of piezoelectric field by doped carriers. These PL and TRPL results indicate that the QE of InGaN/GaN green LED with GSL structure can be improved by Si-doping.

  • PDF

The Analysis of the Muscle Fatigue Recovery Effect on LR9 by Compound Stimulation of the PEMFs and LED (음포혈(陰包, LR9)에서 펄스형 전자기장 및 가시광 LED 복합 자극이 대퇴부 근피로 회복에 미치는 영향 분석)

  • Lee, Na-Ra;Kim, Jung-Yoon;Park, Sun-Woo;Kim, Soo-Byeong;Lee, Hee-Young;Ahn, Soon-Jae;Kim, Young-Ho;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.13-23
    • /
    • 2011
  • Objectives : The aim of this study was to develop the combined medical stimulus system consisted of the PEMFs (Pulsed electromagnetic fields) and LED which are able to stimulate local point such as acupoints and trigger points. Methods : To evaluate the therapeutic effect on the musculoskeletal disorders and the possibility of alternative method on manual acupuncture, we compared the fatigue recovery of two groups by analyzing the EMG and peak torque (non-stimulation and, stimulation group) after strenuous knee exercise. We chose the LR9 as a stimulation point. Results : The median frequency (MF) and fatigue index (F.I) of the stimulation group were recovered faster than those of the non-stimulation group. Also the peak torques of both groups were not restored until after 20 minutes. However, the peak torque of the stimulation group was regained higher than that of the non-stimulation group. Conclusions : We confirmed that the proposed combined stimulus system had useful effects as treatment instrument of musculoskeletal disorder using non-invasive method of PEMFs and LED.

Study on an Automatic Punching System for a LED Display using Flexible Plates (LED 디스플레이용 유연 보드의 자동 펀칭 시스템 연구)

  • Choi, Hyeung-Sik;Kang, Jin-Il;Her, Jae-Gwan;Han, Jong-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.711-717
    • /
    • 2010
  • In this paper, a new automatic punching system that generates pinholes expressing texts or images on a plastic plate is developed. The pin-holed plate is used as a new glamorous display board reflecting colourful lights from the light emitting diode (LED) installed on the edge side of the plate. The punching system has four actuators which work together to make multiple holes with accurate position and depth on the plastic plate. For even reflection of the lights from texts or images on the board and fast production of the pin-holed boards, we developed an accurate actuating structure of the system cooperating with a PID control algorithm. We also built a GUI-based integrated control system to help users easily design luminous texts or images on the plastic plate. Also, we conducted a performance test of the system to verify the punching speed and depth control of the pin holes on the plastic plate.

Anti-scuticociliate effects of a combined treatment with formalin and blue LED (포르말린과 청색 LED 병용처리에 의한 항스쿠티카 효과)

  • Kang, Mun-Gyeong;Lee, Ju-Yeop;Lee, Yoonhang;Kim, Do-Hyung
    • Journal of fish pathology
    • /
    • v.35 no.1
    • /
    • pp.113-120
    • /
    • 2022
  • Scuticociliatosis caused by Miamiensis avidus is a very important parasitic disease in olive flounder farming industry. The aim of this study was to determine effect of combined treatment with blue LED (light-emitting diode) illumination and formalin on olive flounder (Paralichthys olivaceus) infected with M. avidus. Different intensity of 405 nm LED (20, 40, and 60 μmol·m-2·s-1) was illuminated on 2.2×104 cells/well of M. avidus in a 24 well microplate for 24 h. Also, 2.4×104 cells/well of M. avidus were exposed to varying combinations of 60 μmol·m-2·s-1 of 405 nm LED and serial 10-fold dilutions of formalin (from 10 to 100 ppm) for 15, 30, 45, and 60 min. Surviving M. avidus were counted using a hemocytometer. For in vivo test, flounder acclimatized at 11-12 practical salinity unit (psu) were challenged with 2×106 cells/ml of M. avidus by immersion method for 1 h. Then, fish were moved and divided into four groups; "F" group, treated with formalin at 50 ppm; "L" group, treated with 60 μmol·m-2·s-1 of 405 nm LED; "C" group, treated with combination of the two methods; and the control group. After treatment for 30 min, fish were transferred to new tanks (salinity = 11-12 psu) and observed for 3 weeks. As a result, illumination of 405 nm LED at 60 μmol·m-2·s-1 killed 100% of M. avidus after 12 h, while 67% and 90% of the scuticociliate died at 20 and 40 μmol·m-2·s-1, respectively, after 24 h exposure. One hundred percent of M. avidus was killed at 90, 80, 80 and 70 ppm after exposure to formalin for 15, 30, 45 and 60 min, respectively. However, combined method (e.g., 60 μmol·m-2·s-1 of 405 nm-LED plus 50 ppm formalin) killed the parasite within 30 min. From in vivo test, similarly, survival rates of fish challenged with M. avidus were 100%, 43%, 29% and 0% in the C, F, L, and control groups, respectively. Results obtained in this study demonstrates that the combined treatment method has clear synergistic effect on scuticociliatosis in fish.

Application of White Light Emitting Diodes to Produce Uniform Scions and Rootstocks for Grafted Fruit Vegetable Transplants (과채류 접목 시 균일한 접수와 대목 생산을 위한 백색 LED의 적용)

  • Hwang, Hyunseung;Chun, Changhoo
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.14-21
    • /
    • 2022
  • Uniform scions and rootstocks should be produced to ensure grafting success. Light quality is an important environmental factor that regulates seedling growth. The effects of warm- and cool-white light emitting diode (LED) ratios on seedling growth were investigated. Scions and rootstocks of cucumber, tomato, and watermelon were grown in a closed transplant production system using LED as the sole lighting source. The LED treatments were W1C0 (only warm-white), W1C1 (warm-white: cool-white = 1:1), W3C1 (warm-white: cool-white = 3:1), and W5C2 (warm-white: cool-white = 5:2). The seedlings grown in W1C1 had the shortest hypocotyls, and the seedlings grown in W1C0 had the longest hypocotyls among the three tested vegetables. The hypocotyls of watermelon scions, watermelon rootstocks, and tomato rootstocks were shortest in W1C1, followed by those in W3C1, W5C2, and W1C0, but there was no significant difference between W3C1 and W5C2, which remained the same as the ratio of cool-white LEDs increased. In addition, tomato scions had the first and second longest hypocotyls in W1C0 and W3C1, respectively, and the shortest hypocotyls in W5C2 and W1C1, along with W5C2 and W1C1, although the difference was not significant. The stem diameter was highest in W1C0 except for tomato seedlings and rootstocks of watermelon. The shoot fresh weight of scions and rootstocks of cucumber and watermelon and the root fresh weight of cucumber scions were lowest in W1C1. These results indicated that different ratios of LED lighting sources had a strong effect on the hypocotyl elongation of seedlings.

Relationship between battery level and irradiance of light-curing units and their effects on the hardness of a bulk-fill composite resin

  • Fernanda Harumi Oku Prochnow ;Patricia Valeria Manozzo Kunz;Gisele Maria Correr;Marina da Rosa Kaizer;Carla Castiglia Gonzaga
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.4
    • /
    • pp.45.1-45.10
    • /
    • 2022
  • Objectives: This study evaluated the relationship between the battery charge level and irradiance of light-emitting diode (LED) light-curing units (LCUs) and how these variables influence the Vickers hardness number (VHN) of a bulk-fill resin. Materials and Methods: Four LCUs were evaluated: Radii Plus (SDI), Radii-cal (SDI), Elipar Deep Cure (Filtek Bulk Fill, 3M Oral Care), and Poly Wireless (Kavo Kerr). Irradiance was measured using a radiometer every ten 20-second activations until the battery was discharged. Disks (4 mm thick) of a bulk-fill resin (Filtek Bulk Fill, 3M Oral Care) were prepared, and the VHN was determined on the top and bottom surfaces when light-cured with the LCUs with battery levels at 100%, 50% and 10%. Data were analyzed by 2-way analysis of variance, the Tukey's test, and Pearson correlations (α = 5%). Results: Elipar Deep Cure and Poly Wireless showed significant differences between the irradiance when the battery was fully charged versus discharged (10% battery level). Significant differences in irradiance were detected among all LCUs, within each battery condition tested. Hardness ratios below 80% were obtained for Radii-cal (10% battery level) and for Poly Wireless (50% and 10% battery levels). The battery level showed moderate and strong, but non-significant, positive correlations with the VHN and irradiance. Conclusions: Although the irradiance was different among LCUs, it decreased in half of the devices along with a reduction in battery level. In addition, the composite resin effectiveness of curing, measured by the hardness ratio, was reduced when the LCUs' battery was discharged.

Optical Simulation Study of the Improvement of Color-rendering Characteristics of White Light-emitting Diodes by Using Red Quantum-dot Films (적색 양자점 필름을 이용한 백색 발광 다이오드의 연색성 개선에 대한 광학 시뮬레이션 연구)

  • Lee, Gi Jung;Hong, Seung Chan;Lee, Jung-Gyun;Ko, Jae-Hyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.163-171
    • /
    • 2021
  • Conventional white light-emitting diodes (LEDs) for lighting applications consist of blue LEDs and yellow phosphors, the spectrum of which lacks deep red. To improve the color-rendering characteristics of white LEDs, a red quantum-dot film was applied to the diffuser plate of LED lighting. The mean free paths of the quantum dots and the concentration of the TiO2 particles in the diffuser plate were adjusted to optimize the optical structure of the lighting. The color-rendering index (CRI) was greater than 90 for most conditions, which demonstrates that adoption of the red quantum-dot film is an effective way for improving the color-rendering properties of conventional white LEDs. The angular dispersion of color coordinates could be removed by utilizing the optical cavity formed between the diffuser plate and the reflector on the bottom of the lighting, where multiple passages of the light through the quantum-dot film reduced the differences in optical path length depending on the viewing angle.

The Design of an Infrared Transcutaneous Control Unit for Totally Implantable Middle Ear System (완전 이식형 인공중이를 위한 체외 및 체내 제어시스템 구현)

  • 정의성;강호경;박일용;윤영호;김민규;송병섭;원철호;조진호
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.5
    • /
    • pp.71-78
    • /
    • 2004
  • An infrared remote control-type transcutaneous control device using a $\mu$-processor is design for the totally implantable middle ear system. An infrared light transmission model for the tissue of skin was introduced and then a radiant intensity and the required current of the infrared light emitting diode(IR LED) driving circuit at transmission part were calculated for the external control device. And the transmission part generates IR signal by the system's own data protocol which prevents interferences from other infrared remote controls of the household appliances. The control part of the implanted device was designed to analyze functions of the received infrared(IR) signal that indicate the power ON/OFF and volume UP/DOWN. After the system is implemented, a data transmission experiments using 4 mm thickness of porcine skin were carried out. From the experiment, it was verified that the infrared control signal was transmitted to receiving module of the implemented system without any error.