• 제목/요약/키워드: Light Storage

검색결과 639건 처리시간 0.03초

Determination and classification of intraoral phosphor storage plate artifacts and errors

  • Deniz, Yesim;Kaya, Seher
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.219-228
    • /
    • 2019
  • Purpose: The aim of this study was to determine the reasons and solutions for intraoral phosphor storage plate (PSP) image artifacts and errors, and to develop an appropriate classification of the artifacts. Materials and Methods: This study involved the retrospective examination of 5,000 intraoral images that had been obtained using a phosphor plate system. Image artifacts were examined on the radiographs and classified according to possible causative factors. Results: Artifacts were observed in 1,822 of the 5,000 images. After examination of the images, the errors were divided into 6 groups based on their causes, as follows: images with operator errors, superposition of undesirable structures, ambient light errors, plate artifacts (physical deformations and contamination), scanner artifacts, and software artifacts. The groups were then re-examined and divided into 45 subheadings. Conclusion: Identification of image artifacts can help to improve the quality of the radiographic image and control the radiation dose. Knowledge of the basic physics and technology of PSP systems could aid to reduce the need for repeated radiography.

PLS-II 용 반도체 스위치 기반 키커 펄스 모듈레이터 설계 및 제작 (Design and Implementation of Solid-State Kicker Modulator for PLS-II)

  • 안석호;공형섭;박웅화;이병준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.307-308
    • /
    • 2019
  • The Pohang Light Source (PLS) - II is a 3 GeV third-generation synchrotron radiation facility. To inject electron beam from LINAC, a kicker modulator system and kicker magnets are installed in the PLS-II storage ring tunnel. The injected beam then falls into the storage ring beam dynamic aperture. This paper describes the design and implementation of the solid-state kicker modulator for PLS-II. The solid-state kicker modulator is consisted of high voltage solid state switch stacks. the technical considerations of the solid-state switch stacking for kicker modulator is discussed. The achieved capability of the solid-state kicker modulator demonstrates that is fulfills the design requirement of providing half-sine pulsed current of 10kA (peak), 6us (Base-width), with jitter < 2ns (Standard deviation). simulation and experimental results are presented to demonstrate the performance of the solid-state kicker modulator.

  • PDF

새포아풀(Poa annua sp.)의 종자휴면과 발아특성 (Seed Dormancy and Germination Characteristics of Annual Bluegrass (Poa annua L.))

  • 김태준;송재은;최정섭;조광연
    • 아시안잔디학회지
    • /
    • 제15권1호
    • /
    • pp.15-20
    • /
    • 2001
  • Two types of annual bluegrass have been reported, and those consist of annual type (Poa annua ssp. annua) and perennial type (Poa annua ssp. reptans). As a weed, annual bluegrasses are commonly found in putting greens and fairways in many golf courses. Due to its strong competitiveness such as tremendous seed reproduction rate a year, prostrate growth habit, and no herbicide availability, annual bluegrasses have been considered as one of the most hard-to-control weeds in turf management systems. A growth chamber study was conducted to determine seed dormancy and to understand seed germination characteristics of annual bluegrass (Poa annua ssp. annua). Freshly harvested seeds showed 80 and 55% germination at 30 and $35^{\circ}C$, respectively, indicating that the optimum temperature of annual bluegrass is $30^{\circ}C$. However, the seed germination occurred only under light condition at any given temperature. This result demonstrated that light is prerequisite for the seed germination, and no primary dormancy of annual bluegrass seed exists. Secondary seed dormancy induced by unfavorable temperatures and dark condition was broken through 4 to 6 wk-storage at $4^{\circ}C$ with moisture, and the stored seeds germinated at $20^{\circ}C$ even under the dark. In red and far-red light trial, fresh seeds resulted in 40% germination under red while no seed germination occurred under far-red light condition, indicating that phytochrome Pr and Pfr could be related to annual bluegrass seed germination. When the far-red light replaced the red the germination was recovered, but this reversibility did not reach to the germination level under the red light only. This result implied that other lights than red and far-red would play an important role on seed germination of annual bluegrass.

  • PDF

가속수명시험(ALT)을 이용한 WOLED의 성능 및 신뢰성 평가 (Evaluation of Performance and Reliability of a White Organic Light-Emitting Diode(WOLED) Using an Accelerated Life Test(ALT))

  • 문진철;박형기;최충석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.13-19
    • /
    • 2012
  • The purpose of this study is to extract the major factors related to the deterioration mechanism of white organic light-emitting diodes(WOLED) by performing accelerated testing of temperature, voltage, time, etc., and to develop an accelerated life test(ALT) model. The measurement results of the brightness of the WOLED exhibited that their average brightness tended to increase as the operating voltage increased and that the half-life period of the brightness appeared after approximately 400 hours when the operating voltage was 20V and the ambient temperature was $85^{\circ}C$. It could be seen that although the WOLED showed comparatively the same brightness when the initial acceleration began after the operating voltage was applied to it, its brightness changed excessively after the WOLED's thermal storage had been made. In addition, it was observed that the half-life period was reduced as the ambient temperature and applied voltage increased. The strength of the WOLED which had been maintained in the range of visible light at the maximum load was reduced by the deterioration of the organic light emitting material due to the influence of the operating voltage and temperature, and the reduction of emitted light was small at low voltage and temperature. It could be seen that the failure of the WOLED during the ALT was caused by wear due to load accumulation over time, and that Weibull distribution was appropriate for the life distribution and acceleration was established between test conditions. From the WOLED analysis, it is thought that factors influencing the brightness deterioration are voltage, temperature, etc., and that comprehensive analysis considering discharge control, dielectric tangent margin, etc., would further increase the reliability.

Effects of 3 different light-curing units on the physico-mechanical properties of bleach-shade resin composites

  • Azin Farzad;Shahin Kasraei;Sahebeh Haghi;Mahboubeh Masoumbeigi;Hassan Torabzadeh;Narges Panahandeh
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.9.1-9.11
    • /
    • 2022
  • Objectives: This study investigated the microhardness, flexural strength, and color stability of bleach-shade resin composites cured with 3 different light-curing units. Materials and Methods: In this in vitro experimental study, 270 samples were fabricated of bleach and A2 shades of 3 commercial resin composites (Point 4, G-aenial Anterior, and Estelite Sigma Quick). Samples (n = 5 for each trial) were cured with Bluephase N, Woodpecker LED.D, and Optilux 501 units and underwent Vickers microhardness and flexural strength tests. The samples were tested after 24 hours of storage in distilled water. Color was assessed using a spectrophotometer immediately after preparation and 24 hours after curing. Data were analyzed using 3-way analysis of variance and the Tukey test (p ≤ 0.001). Results: Samples cured with Optilux exhibited the highest and those cured with LED.D exhibited the lowest microhardness (p = 0.023). The bleach shade of Point 4 composite cured with Optilux displayed the highest flexural strength, while the same composite and shade cured with Sigma Quick exhibited the lowest (p ≤ 0.001). The color change after 24 hours was greatest for the bleach shade of G-aenial cured with Bluephase N and least for the A2 shade of Sigma Quick cured with Optilux (p ≤ 0.001). Conclusions: Light curing with polywave light-emitting diode (LED) yielded results between or statistically similar to those of quartz-tungsten-halogen and monowave LED in the microhardness and flexural strength of both A2 and bleach shades of resin composites. However, the brands of light-curing devices showed significant differences in color stability.

초소형 Sled-type 이중 서보 엑추에이터 설계 및 특성 분석 (The Design and Performance Test of Miniaturized Sled Type Dual-Servo Actuator)

  • 강동우;김기현;정재화;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.357-360
    • /
    • 2002
  • Nowadays, the improvement and development of Multi-media, information and communication technology are rapidly processed. And many products, for example, digital camera, digital camcorder, and PDA, are used for them. They need large data storage capacity and small size, light storage system. Due to that, many studies and researches in data storage system have been carried out. Especially, micro drive system was presented by IBM.(1) However, its system is expensive and uneasy to be portable. In ODD technologies, 1 inch drive system is not yet or in processing status.(2) If to be possible and to be come up, it is cheap than HDD system and easy to transfer information. In this paper, a miniaturized actuator(about linch) is designed and tested for ODD system. Specially, it is adapted for NFR(Near-field Recoding) system using SIL(Solid Immersion Lens). It is the dual-servo actuator which consists of a coarse actuator and fine actuator. Its actuating force generation method is VCM(Voice Ceil Motor). The fine actuator has 4-wire suspensions and bobbin wrapped by coil and includes focusing motion as well as tracking motion. The coarse actuator has an actuating coil and V-grooved guide mechanism. Also, the characteristics of the designed actuator is estimated by sine-swept mode and LDV(Laser Doppler Vibro-meter).

  • PDF

수용가용 전자전력저장시스템의 경제성 분석 (Economic Assessment of Customer Owned Battery Energy Storage System (BESS))

  • 최준호;김재철;홍종석;손학식;임태훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.180-183
    • /
    • 2000
  • The Battery Energy Storage System(BESS) has lots of advantages such as load levelling, quick response emergency power(spinning reserve), frequency and voltage control, improvement of reliability, and deferred generation and transmission construction. The economic feasibility requires justification from the customer side of meter to promoting the dissemination of BESS nationally. In this paper, we proposed the economic assessment model of customer owned Battery Energy Storage System(BESS) which is complemented and improved the existing model. The proposed model is applied to the typical customer type(light-industrial commercial, and residential) which are taken from the statistical analysis on the load profile survey of Korea Electric Power COmpany (KEPCO). The economic assessment performed for each customer type to justifying their economic feasibility of BESS installation from the economic measures such as payback period, overall benefits, ROI, and ROR. The results of this paper are useful to the customer investment decision making and the national energy policy & strategy.

  • PDF

Building Smart Microgrid Test-Bed를 이용한 전력사용량 패턴 최적화방안 연구 (A Study on the Optimization of Power Consumption Pattern using Building Smart Microgrid Test-Bed)

  • 이상우;강진규;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.1-7
    • /
    • 2014
  • The microgrid system is the combination of photovoltaic(PV) array, load, and battery energy storage system. The control strategies were defined as multi-modes of operation, including rest operation without use of battery, power charging, and power discharging, which enables grid connected mode or islanded mode. Photovoltaic power is a problem of the uniformity of power quality because the power generated from solar light is very sensitive to variation of insolation and duration of sunshine. As a solution to the above problem, energy storage system(ESS) is considered generally. There fore, in this study, we did basic research activities about optimization method of the amount of energy used, using a smart microgrid test-bed constructed in building. First, we analyzed the daily, monthly and period energy pattern amount of power energy used, and analyzed PV power generation level which is built on the roof. Utilizing building energy pattern analysis data, we was studied an efficient method of employing the ESS about building power consumption pattern and PV generation.

포항가속기 저장링챔버의 헬륨누설검사 (Helium Leak Test for the PLS Storage Ring Chamber)

  • 최만호;김형종;최우천
    • 비파괴검사학회지
    • /
    • 제13권3호
    • /
    • pp.31-38
    • /
    • 1993
  • 포항가속기 저장링 진공챔버는 진공도가 $10^{-10}Torr$로 유지될 수 있도록 설계되었고, 초고진공에 적합하도록 TIG용접을 하여 헬륨에 대한 누설률이 $1{\times}10^{-10}Torr{\cdot}{\ell}/sec$ 이하의 기밀성이 요구되고 있다. 저장링 진공챔버에 적용된 TIG용접방법과 결함에 대해 논하고 누설검사에 사용된 헬륨누설검사기의 원리 및 검사방법에 대해서 보고하고자 한다.

  • PDF

마요네즈 저장 중 미세구조의 변화 (Microstructural Changes of Mayonnaise during Storage)

  • 송영선
    • 한국식품과학회지
    • /
    • 제22권3호
    • /
    • pp.300-306
    • /
    • 1990
  • 마요네즈 저장 중 미세구조의 변화를 광학현미경과 주사 전자현미경으로 관찰하였다. 신선한 마요네즈는 다양한 크기의 지방구로 이루어져 있었으며 지방구의 크기 분포는 정규분포를 보였다. $60^{\circ}C$$-10^{\circ}C$에서 저장하는 동안 지방구의 합일(合一)에 의해 지방구가 커지는 경향을 보였으며, 탁도에 의한 실험결과 또한 이러한 지방구의 합일(合一)현상을 확인시켜 주었다. 전자현미경은 광학현미경에 비해 크기가 작은 지방구를 측정하기가 용이하였으며, 따라서 지방구의 평균 입경이 작았다. 이것은 전자현미경의 높은 해상력과 심도 때문이며, 더욱이 시료를 회석할 필요가 없어 균일한 지방구의 분포를 보여주는 전자현미경 방법은 광학현미경에 비해 유화제품의 지방구 분포를 측정하기에 유리한 방법이라 하겠다.

  • PDF