• Title/Summary/Keyword: Lifting system

Search Result 331, Processing Time 0.026 seconds

CLINICAL STUDY ON SURVIVAL RATE OF OSSEOINTEGRATED IMPLANTS (골유착성 치과 임플란트의 생존율에 관한 임상적 연구)

  • Choi, Ji-Yeon;Koh, Se-Wook;Ryu, Hwun-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.4
    • /
    • pp.306-313
    • /
    • 2009
  • Objectives: The aim of the present review was to evaluate survival rate and various factors associated with survival of osseointegrated implants. Patients and methods: The clinical comparisons were performed to evaluate survival rate of 794 endosseous implants that had been inserted between 2004 through 2008 in relation to sex and age of patients, position of implant, implant system and surface characteristics, length and diameter of implant, and bone graft technique. Results: The survival rate of implant was 94.3% in posterior area of maxilla and 98.6% in posterior area of mandible by position of implant, a statistically significant difference. As to diameter of implant, survival rate was 98.4% between the 4.0 and 4.5 mm and 75.0% in larger than 5.0 mm, that was statistically significant difference. There was a statistically significant difference regard to bone graft and surgical technique. The implant survival rate was 89.0% in a placement site which performed sinus lifting, and in case of implant placement with guided bone regeneration technique and without bone grafting was 97.6% and 100% each. Conclusion: According to these findings, this study establishes a relationship between survival rate of implant and position, surface characteristics, diameter of implant and bone graft technique.

A Study on Lifting Characteristics of Air-Lift Pump (공기양정(Air-Lift)펌프의 양수특성에 관한 연구)

  • Kim, Dong-Kyun;Lee, Cheol-Jae;Bae, Suk-Tae;Cho, Dae-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.14-21
    • /
    • 1999
  • As an effective means to convey crushed materials from seabed to onboard ship and to raise hazardous or abrasive liquids, air-lift pump provides a reliable mechanism due to its simple configuration and easy-to-operate principle. The present study is focused on investigation of related performance by the analysis program based on the gas-liquid two-phase flow in circular pipes. The program covers pump operating in isothermal and vertical two-phase flow with Newtonian liquids. It is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates. The comparison between riser performance of the conveyed liquid flow rate calculated by the computer program and measured data with large scale air lift pump system constructed in 200 meter depth vertical tank reveals similar distribution.

  • PDF

A Development of a Counter Balancing Experimental Equipment (카운터 밸런싱 실습장치 개발)

  • Ryu, Jae-Hu;Huh, Jun-Young
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.5 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • The counter balancing is a technique to control a load which is acting to actuator when the load changes from a resistance state to over running state according to the structural change of the load for the case of lifting or carrying a heavy load in industrial site. Even though this technique is frequently used in industrial site, there is no widely known design procedure and educational equipment in home and abroad. Therefore, in this study a new idea was presented to develop an counter balancing educational equipment. The idea was realized through the process of system modeling and simulation, drawing out of design parameters, manufacturing of a prototype. Finally the usefulness of this developed educational equipment was demonstrated by experiments. It is expected that by using this equipment a big help would be given to students who should understand the counter balancing equipment which is frequently encountered in industrial site.

  • PDF

A Numerical Study on the Performance Analysis of the Mixed Flow Pump for FPSO (수치해석을 이용한 FPSO용 사류펌프 성능해석 연구)

  • Kang, Kyung-Won;Kim, Young-Hun;Kim, Young-Ju;Woo, Nam-Sub;Kwon, Jae-Ki;Yoon, Myung-O
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.12-17
    • /
    • 2011
  • The seawater lift pump system is responsible for maintaining the open canal level to provide the suction flow of circulating water pump at the set point. The objective of this paper is to design a 2-stage mixed flow pump (for seawater lifting) by inverse design method and to evaluate the overall performance and the local flow fields of the pump by using a commercial CFD code. Rotating speed of the impeller is 1,750 rpm with the flow rate of 2,700 $m^3$/h. Finite volume method with structured mesh and realized k-${\varepsilon}$ turbulent model is used to guaranty more accurate prediction of turbulent flow in the pump impeller. The numerical results such as static head, brake horse power and efficiency of the mixed flow pump are compared with the design data. The simulated results are good agreement with the design data less 3% error.

Hinge Mechanism Design of Smooth-Lift-Unit for Flat Panel Display (평판디스플레이용 유연승강유니트의 힌지기구 설계)

  • Cheong, Seon-Hwan;Choi, Seong-Dae;Cho, Gyu-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.3
    • /
    • pp.85-91
    • /
    • 2007
  • This study was carried out to minimize the lifting force of a two hinge type stand mechanism. This unit is designed for the display devices in order to enhance the ergonomics for effective height adjustment and maintenance at any preferred position. The unit will be very useful for the mechanism fabricated with a coil spring and disc springs as a torque generator. The maximum and the minimum torque value should be calculated initially for the smooth lift. And the reasonable torque distribution is necessary to prevent any auto lift and auto dropping at any position because the torque generated by coil spring is more sensitive than disc spring in tilting the position. Therefore, the analysis of the coil spring is requisite to issue the specific torque value depending on the distorted angle with securing reliability of a long time storage condition. After the theoretical torque value was calculated, the evaluation was carried out by making a proto-type sample, then distorted angle was updated by experiment. The result of this study can readily be applied to various units for the optimization of the smooth lift.

  • PDF

Numerical and Experimental Analyses of the Aerodynamic Characteristics of a Counter Rotating Axial Fan (엇회전식 축류홴의 공력 특성에 관한 전산 해석 및 실험)

  • Cho, Jin-Soo;Won, Yu-Phil;Lee, Moon-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.325-337
    • /
    • 2000
  • A study was done on the numerical and experimental analyses of the aerodynamic characteristics of a counter rotating axial fan. The numerical analysis uses the frequency domain panel method developed for the aerodynamic analysis of interacting rotating systems, which is based on the unsteady lifting surface panel method. Each stage of interaction involves the solution of an isolated rotor, the interaction being done through the Fourier transform of the induced velocity field. Numerical results showed good agreements with other experimental data for single and counter rotating propeller systems. And they were compared with the experimental results of the counter rotating axial fan studied in the present paper. The performance test was carried out based on the Korean Standard (KS B 6311). It was focused on the relative efficiency increase of a counter rotating system for a single rotating one, and effects of the axial distance between the front and rear rotors on overall fan performances were investigated. As a result, it was shown that the counter rotating axial fan has the efficiency 14% higher than the single rotating one at peak efficiency points.

The Analysis of Low Back Loading and Muscle Fatigue while Lifting an Asymmetric Load (비대칭무게중심을 지닌 물체 들기 작업시 허리부위 등근육 부하 및 피로 분석)

  • Han, Seung-Jo;Kim, Sun-Uk
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.30-36
    • /
    • 2012
  • This study is aimed to show that an asymmetric load in the frontal plane leads to an increase in low back loading and fatigue in comparison with a symmetric load when workers lift an external weight by investigating previous studies and verifying the phenomenon with an experiment. Ten male subjects are required to lift and hold an given external load at 70cm height during 50sec, then the EMG amplitude and median frequency on bilateral low back muscle groups (Longissimus, Iliocostalis, and Multifidus) are recorded and analyzed. Independent variables are two-level load weight (13kg, 20kg) and three-level LCG (Center, 6.5cm to the right, and 13cm to the right), and dependent variables are EMG amplitude average, difference, and Fatigue Index (FI). Results show that load weight increases significantly amplitude average and FI, but LCG does significantly amplitude difference and FI significantly (P-value < 0.05). Also the correlation coefficient between amplitude difference and FI is over 0.99. These implies that trunk loading should be explained by not EMG amplitude but muscle fatigue aspect since the association between an external load and amplitude is linear, but the relationship between an external load and median frequency as muscle fatigue index is almost exponential.

Upper Limbs Related Muscle Strength and Fatigue During the Wrench Job for Korean Young Aged (렌치 작업에서의 청년층의 상지근력 및 근피로도에 관한 연구)

  • Yoon, Hoon-Yong;Kim, Eun-Sik
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.88-97
    • /
    • 2012
  • The muscle strengths in various postures are still used in the workplace, although mechanization and automation have been continuously accomplished. The aim of this study is to measure the maximum muscle strength and analyze the muscle fatigue during the various wrench jobs which are one of the upper limbs related works. Four hundreds and eighty five college students (243 males and 242 females) participated in this study. Twelve muscle strengths which are using for pulling, pushing, lifting and lowering the wrench with various postures are measured. For every moment, the muscle strengths for both hands were measured. In each measurement, five seconds averaged value and peak value were collected. The averaged value of preferred hand and non-preferred hand was compared. Also, the averaged value of opposite movement was compared through t-test. The fatigue of agonist for each movement was analyzed using EMG analysis. The result of this study can provide some basic information not only in designing the tools in work but also in selection, training and management of workers.

STUDY ON THE HYDRAULIC DESIGN OF 2 STAGE MIXED FLOW PUMP (2단 사류펌프의 임펠러 성능향상 방안 연구)

  • Kim, Y.J.;Woo, N.S.;Kwon, J.K.;Chung, S.K.;Park, U.S.;Bae, S.E.;Park, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.556-560
    • /
    • 2011
  • The seawater lift pump system is responsible for maintaining the open canal level to provide the suction flow of circulating water pump at the set point. The objective of this paper is to design a 2-stage mixed flow pump(for seawater lifting) by inverse design and to evaluate the overall performance and the local flow fields of the pump by using a commercial CFD code. Rotating speed of the impeller is 1,750 rpm with the flow rate of 2,700 $m^3/h$. Finite volume method with structured mesh and Realizable ${\kappa}-{\varepsilon}$ turbulent model is used to guaranty more accurate prediction of turbulent flow in the pump impeller. The numerical results such as static head brake horse power and efficiency of the mixed flow pump are compared with the reference data. Also, the periodic condition calculation method for the mixed flow pump was carried out in order to investigate the pump performance characteristics with the modification of impeller geometry.

  • PDF

Active Control of Flow-Induced Vibration Using Piezoelectric Actuators (압전 작동기를 이용한 유체 유기 진동의 능동 제어)

  • 한재홍
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.446-451
    • /
    • 2003
  • This paper presents some examples of active control of flow-induced vibration using piezoelectric actuators. The flutter phenomenon, which is the dynamic instability of structure due to mutual interaction among inertia, stiffness, and aerodynamic forces, may cause catastrophic structural failure, and therefore the active flutter suppression is one of the main objectives of the aeroelastic control. Active flutter control has been numerically and experimentally studied for swept-back lifting surfaces using piezoelectric actuation. A finite element method, a panel aerodynamic method, and the minimum state space realization are involved in the development of the governing equation, which is efficiently used for the analysis of the system and design of control laws with modern control framework. The active control suppressed flow-induced vibrations and extended the flutter speed around by 10%. Another representative flow-induced vibration phenomenon is the oscillation of blunt bodies due to the vortex shedding. In general, it is quite difficult to set up the numerical model because of the strong non-linearity of the vortex shedding structure. Therefore, we applied adaptive positive position feedback controller, which requires no pre-determined model of the plant, and successfully suppressed the flow-induced vibration.

  • PDF