• Title/Summary/Keyword: Lifting Analysis

Search Result 431, Processing Time 0.027 seconds

Application of NIOSH Lifting Equation to Analysis of Workload for Patients Transferring by Physical Therapist: a Case Study (물리치료사의 환자 운반 시 작업 부하 분석에 NIOSH 들기 공식 적용: 사례연구)

  • Lee, In-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.3
    • /
    • pp.119-124
    • /
    • 2009
  • Purpose: The National Institute for Occupational Safety and Health (NIOSH) lifting equation (NLE) is a useful tool to ergonomically analyze a workload. The NLE has high reliability and it can assess tasks by analyzing the work process. The purpose of this case study was to try using the NLE to analyze the workload of transferring patients by physical therapists in the hospital setting. Methods: We observed a physical therapist (PT) transferring patients from a wheelchair to a tilt table and a therapeutic table in one day. Two types of patient transferring methods were evaluated; (1) the manual single person method of stand, pivot and transfer, and (2) manual two person lifting under the thigh and grasping the waist for totally dependent patients. Results: The NIOSH lifting indexes of a person grasping the waist during the manual two person lifting were 5.52~4.48 according to the patient's weight. The NIOSH lifting indexes were 3.34 and 4.48 for the tasks performed by the manual single person method. Conclusion: Because transferring patients is not done very frequently, patients transferring tasks by a PT are not included as one of the musculoskeletal disorder related risky work criteria of the Korea Ministry of Labor. But the NIOSH lifting indexes of a person grasping the waist during the manual two person lifting and the manual single person method were over the NIOSH recommended weight limit threshold.

  • PDF

A Study for Rationalization of Lifting Lug Design of Ship Block (선박블록 탑재용 러그구조의 설계합리화를 위한 연구)

  • 함주혁
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.249-261
    • /
    • 1997
  • A basic study on the lifting lug design has performed through the rational and systematic process. In order to evaluate the proper design-load distribution around lug eye investigation of contact force between lifting lug and shackle pin is performed using non-linear parametric analysis idealized by gap element models. Gap element modeling and nonlinear analysis procedures are illustrated and discussed based on MSC/NASTRAN. Some analysis and design guides are suggested through the consideration of several important effects such as stress distribution pattern, circumferential contact force distribution along the lug eye face, loading share rate between lug main plate and doubler, effect of loading direction, relation between applied force and deflection and size effect of shackle pin radius. Additionally optimum design studies are performed and general trends according to the variation of design parameters are suggested.

  • PDF

Evaluation Method of Physical Workload in Overhead Lifting Posture Using Surface EMG Analysis (sEMG 분석을 이용한 높이 들어올리기 자세에서의 신체적 작업부하의 정량적 평가방법 개발)

  • Lee, Young-Jin;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.4
    • /
    • pp.328-335
    • /
    • 2011
  • For human factor engineering and wearable robot design, the quantitative assessment of physical workload is needed. Through measuring the surface EMG (sEMG) and analysis, the physical workload in overhead lifting posture is presented in quantitative manner. By normalizing sEMG activities with maximal voluntary contraction (MVC), the inter-subject variability is reduced. In all muscles, %MVC increased as the weight of lifting object increases. In anterior deltoid muscle, the %MVC was 3-4 times higher than the other muscles which imply that this muscle performs the major role in the overhead lifting posture. In fatigue analysis, %MVC and the mean frequency in muscle of anterior deltoid changed markedly when compared with other muscles. Through the suggested procedures and analysis, the physical workload for a specific posture can be represented in quantitative way but the clinical meaning for the value should be investigated further.

Relationship Between the Number of Hip Abduction Performance With Contralateral Adduction in Side-lying and the Lateral Pelvic Shift Distance During One-leg Lifting

  • Do-eun Lee;Jun-hee Kim;Gyeong-tae Gwak;Young-soo Weon;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.30 no.2
    • /
    • pp.152-159
    • /
    • 2023
  • Background: The gluteus medius (Gmed) plays a critical role in maintaining frontal plane stability of the pelvis during functional activities, such as one-leg lifting. Side-lying hip abduction (SHA) has been used as a dynamic test to evaluate Gmed function. However, the abduction force of the lower leg against the floor is not controlled during SHA. Therefore, hip abduction performance with contralateral adduction in the side-lying position (HAPCA) can be proposed as an alternative method to assess performance of hip abduction. If the number of HAPCA is related to the lateral pelvic shift distance, a new quantitative measurement for hip abductor function may be presented. Objects: This study aimed to investigate the relationship between the number of successful HAPCA and the lateral pelvic shift distance during one-leg lifting. Methods: Thirty healthy participants were recruited, and lateral pelvic shift distance was measured during one-leg lifting test using two-dimensional analysis. The number of successful HAPCA was counted when participants touched both target bars at the beat of a metronome. Results: There was a negative correlation between the number of HAPCA and lateral pelvic shift distance during one-leg lifting (r = -0.630, p < 0.05). The number of HAPCA accounted for 39.7% of the variance in the lateral pelvic shift distance during one-leg lifting (F = 18.454, p < 0.001). Conclusion: The number of successful HAPCA is significantly correlated with lateral pelvic shift distance during one-leg lifting. This finding suggests that HAPCA can be proposed as a new measurement for hip abductor performance and more research is needed on its relationship with hip abductor strength.

Comparison of Abdominal Muscle Activation During Lifting with Stabilization Method (물건 들기 시 복부 안정화 방법에 따른 몸통 근육 활성도 비교)

  • Kim, Ha-Rim;Son, Ho-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.4
    • /
    • pp.95-102
    • /
    • 2021
  • PURPOSE: This study examined the muscle activity of the abdominal muscle when lifting with abdominal hollowing with visual feedback and lifting with a pelvic compression belt. This study suggests how to lift an object safely in the workplace for people who bend their backs repeatedly. METHODS: The study was conducted on healthy men in their 20s and 30s. When lifting a 7kg object, lifting with abdominal hollowing with visual feedback, and lifting an object with a pelvic compression belt were performed three times in random order. The muscle activities were measured rectus abdominis (RA), external oblique (EO), internal oblique/transverse abdominis (IO/TrA) muscles, and abdominal hollowing exercises, and box lifting exercises were carried out in advance before the experiment. One-way ANOVA was used to compare muscle activities, and a Tukey HSD was used for post-analysis. The level of significance was set to .05. RESULTS: According to the study, there was no significant difference in muscle activity of the RA muscle depending on the lifting method (p > .05). There were significant differences between the EO and IO/TrA muscle (p < .05). The IO/TrA muscle activity showed the largest increase in lifting an abdominal hollowing with visual feedback (p < .05). The EO muscle activity increased in pelvic compression belt lifting (p < .05). The muscle activity was increased in RA, but there was no significant difference (p < .05). CONCLUSION: Abdominal hollowing lifting with visual feedback increases the muscle activity of the IO/TrA muscle, which is higher than normal, and affects the core stability of the body.

Applicability of NIOSH Lifting Equation to analysis of Workload for Patients Transferring (병원 환자 운반 업무의 작업 부하 분석에 NIOSH 들기 작업 공식의 적용 가능성)

  • Gi, Do-Hyeong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.43-50
    • /
    • 2006
  • The purpose of this study was to investigate applicability of NIOSH lifting equation(NLE) to analysis of workload for patient transferring. In principle, the NLE is not applied to analyzing workload of patient transferring, because 1) the task is generally performed by two or more persons; 2) unlike ordinary objects, human body of patients is basically unstable load with their location of the center of mass significantly varying during lifting activity; and 3) the task is done in a restricted work space. This study was conducted through comparison of NIOSH lifting indexes(LIs) and L5/S1 compressive forces by 3DSSPP for patient transferring tasks performed by 2~6 persons. The results showed that LIs are linearly correlated with L5/S1 compressive forces with correlation coefficient of 0.92, which resulted in a significant simple linear regression equation for LIs and L5/S1 compressive forces. Consequently, it was concluded that the NLE is applicable to transferring patient only with slight modification. Based on the results, instead of 1.0 originally used by NIOSH, the LI of 1.5 was proposed as a gauge to estimate whether or not the task needs corrective action to reduce risk for developing lifting-related low back pain.

Analysis on Torques of Shoulder and Elbow Joints of Humanoid Robot Arm for Lifting Tasks (리프팅 작업을 위한 인간형 로봇 팔의 어깨와 팔꿈치 관절 토오크 분석)

  • Kim, Byoung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.3
    • /
    • pp.223-228
    • /
    • 2015
  • This paper analyses the torque characteristics of the shoulder and elbow joints of a humanoid robot arm that is useful for an object lifting and transferring task instead of human beings. For the purpose, some typical human lifting behaviors are considered, and various simulations for lifting and transferring an object have been performed by employing a humanoid robot arm having a simple configuration of shoulder and elbow joints. Through the simulation, it is shown that the torque patterns and ranges of the shoulder and elbow joints required for such a humanoid lifting and transferring task can be found earlier in the design of a humanoid robot arm. As a result, this effort is useful for us to design an effective robot arm.

A study on coupling effect during lifting (들기 작업시 손잡이의 영향에 관한 연구)

  • 장성록;배동철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.119-124
    • /
    • 2003
  • Despite rapid technological advance and increased automation facilities, many jobs and activities in our living require manual materials handling(MMH). These include wide variety of activities such as moving things, lifting bags. boxes or cartons, etc. Many studies found that handle could affect on maximum acceptable weight of lifting, but there were few studies f3r the effects of work posture and coupling in lifting tote box. This study performed that ten male college students were required to lift a tote box with and without handle for three postures (bending, straight, right angle posture). From the experiment, following results were obtained. (1) MVC reduced maximum 23% by type of handle. (2) MVC was highest in straight posture, but was lowest in right angle posture. (3) As a result of ANOVA, MVC paid attention to posture and coupling. (p<0.01) (4) To all handle types, biceps brachii activity was increased in right angle posture. but reduced in straight posture. (5) To all posture, biceps brachii activity was most lively in no handle. The results of MVC measurement, subjective rating, EMG analysis, statistic analysis showed that maximum acceptable weight of lifting was influenced by type of handle and straight posture was more comfortable than other postures. Based on these results, it was concluded that acceptable weight of lifting has to differ for work posture and coupling.

New decoupled wavelet bases for multiresolution structural analysis

  • Wang, Youming;Chen, Xuefeng;He, Yumin;He, Zhengjia
    • Structural Engineering and Mechanics
    • /
    • v.35 no.2
    • /
    • pp.175-190
    • /
    • 2010
  • One of the intractable problems in multiresolution structural analysis is the decoupling computation between scales, which can be realized by the operator-orthogonal wavelets based on the lifting scheme. The multiresolution finite element space is described and the formulation of multiresolution finite element models for structural problems is discussed. Various operator-orthogonal wavelets are constructed by the lifting scheme according to the operators of multiresolution finite element models. A dynamic multiresolution algorithm using operator-orthogonal wavelets is proposed to solve structural problems. Numerical examples demonstrate that the lifting scheme is a flexible and efficient tool to construct operator-orthogonal wavelets for multiresolution structural analysis with high convergence rate.

Comparative Analysis of Lifting Loads of Tower Cranes by Core Structure Construction Methods

  • Choi, Yong Seok;Kim, Taehoon;Kim, Sangdae
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.3
    • /
    • pp.301-306
    • /
    • 2020
  • In tall building construction, the appropriate control of lifting loads on tower cranes is critical in terms of the construction duration of structural works. The adoption of efficient construction methods can be the most effective way of minimizing the inputs of tower cranes and making a lifting plan and management easier. Based on actual data from a tall building project, this study comparatively analyzes lifting loads of tower cranes by the core structure preceding construction method (CSPCM) and the core structure succeeding construction method (CSSCM). The results revealed that the CSSCM could reduce up to about 56.3% of lifting loads for core works and significantly enhance lifting efficiency compared with the CSPCM. Consequently, this enabled a substantial reduction in the construction duration of structural works. This study provides a practical reference to assist engineers and managers in applying efficient construction methods and lifting equipment operation in tall building projects.