• Title/Summary/Keyword: LiftLT

Search Result 7, Processing Time 0.024 seconds

Change of Head Position and Muscle Activities of Neck During Overhead Arm Lift Test in Subjects With Forward Head Posture

  • Kim, Tae-ho;Hwang, Byoung-ha
    • Physical Therapy Korea
    • /
    • v.26 no.2
    • /
    • pp.61-68
    • /
    • 2019
  • Background: Forward head posture (FHP) is a postural alignment of the cervical vertebrae that leads to increased gravitational load on cervical segmental motions. The overhead arm lift test assesses the ability to actively dissociate and control low cervical flexion and move the shoulders through overhead flexion. Objects: The purpose of this study was to explore muscle activities in the upper trapezius (UT), serratus anterior (SA), sternocleidomastoid (SCM), and lower trapezius (LT) alongside changes in head position during the overhead arm lift test in individuals with FHP. Methods: Fifteen subjects with forward head posture and fifteen subjects with normal subjcects were enrolled in this study. The patients performed the overhead arm lift test, and muscle activities of the UT, SCM, SA, and LT were measured using surface electromyography and by evaluating changes in head position. Independent t-tests were used to detect significant differences between the two groups and Cohen's d was calculated to measure the size of the mean difference between the groups. Results: The FHP group demonstrated significantly increased muscle activity of the UT ($32.46{\pm}7.64$), SCM ($12.79{\pm}4.01$), and LT ($45.65{\pm}10.52$) and significantly decreased activity in the SA ($26.65{\pm}6.15$) than the normal group. The change in head position was significantly higher in the FHP group ($6.66{\pm}2.08$) than the normal group. Effect sizes for all parameters assessed were large between the two groups. Conclusion: The subjects with excessive FHP displayed were unable to fix their heads in position during the overhead arm lift test. The overhead arm lift test can thus be used in clinical settings to confirm control of the neck in these subjects.

Efficient Motion Compensated Interpolation Technique Using Image Resizing (영상의 크기 변환을 이용한 효율적인 움직임 보상 보간 기법)

  • Kwon, Hye-Gyung;Lee, Chang-Woo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.4
    • /
    • pp.599-608
    • /
    • 2013
  • Motion compensated interpolation (MCI) techniques are used for increasing the frame rate and generating the side information in the distributed video coding (DVC) system. In this paper, an efficient MCI technique using the image resizing in the DCT or LiftLT domain is proposed, and the performance of the MCI technique using various sub-pixel generation techniques is analyzed. Extensive computer simulations show that the proposed method produces the superior results compared to the conventional methods.

Comparison of the EMG Activities of Scapular Upward Rotators and Other Scapular Muscles Among Three Lower Trapezius Strengthening Exercises (아래등세모근 근력강화 운동방법들 사이의 어깨뼈 위쪽 돌림근과 다른 어깨 근육들의 근활성도 비교)

  • Yong, Joon-Hyoung;Weon, Jong-Hyuck
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.27-35
    • /
    • 2013
  • The aim of this study was to compare the electromyographic (EMG) activity levels of the scapular upward rotators [upper trapezius (UT), lower trapezius (LT), and serratus anterior (SA)] and other scapular muscles [posterior deltoid (PD), levator scapulae (LS), and infraspinatus (IS)] during isometric lower trapezius exercises. Twenty males with no medical history of shoulder pain or upper extremity disorders were recruited for this study. EMG activity was recorded from the UT, LT, SA, PD, LS, and IS while subjects performed three different exercises: Prone arm lift (PAL), Backward rocking diagonal arm lift (BRDAL), Modified Prone Cobra (MPC). One-way analysis of variance (ANOVA) was used to determine any significant differences among the three exercises. A lower relative activation of UT, LT, and SA was seen with the MPC than with the other exercises (p<.05). The relatively lower activation of the UT identified, the MPC exercise as the preferred choice for preferential strengthening the LT (p<.05). However, a higher activation in the PD, LS, and IS occurred with the MPC than with the other exercises (p>.05). The recruitment pattern of synergist varied depending on the exercise posture. These findings suggest that exercise posture is an important factor in the selection of strengthening exercise for weak muscle.

Efficient Image Denoising Method Using Non-local Means Method in the Transform Domain (변환 영역에서 Non-local Means 방법을 이용한 효율적인 영상 잡음 제거 기법)

  • Kim, Dong Min;Lee, Chang Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.69-76
    • /
    • 2016
  • In this paper, an efficient image denoising method using non-local means (NL-means) method in the transform domain is proposed. Survey for various image denoising methods has been given, and the performances of the image denoising method using NL-means method have been analyzed. We propose an efficient implementation method for NL-means method by calculating the weights for NL-means method in the DCT and LiftLT transform domain. By using the proposed method, the computational complexity is reduced, and the image denoising performance improves by using the characteristics of images in the tranform domain efficiently. Moreover, the proposed method can be applied efficiently for performing image denoising and image rescaling simultaneously. Extensive computer simulations show that the proposed method shows superior performance to the conventional methods.

Comparisons of Trunk Muscle Activity During Arm Lift in Prone and Standing Positions With and Without Abdominal Drawing-in Maneuver

  • Kim, Ki-Song;Lim, One-Bin;Yi, Chung-Hwi;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.38-45
    • /
    • 2012
  • The aim of this study is to compare the effect of abdominal drawing-in maneuver (ADIM) on lower trapezius (LT), serratus anterior (SA), and erector spinae (ES) muscle activity during arm lifts in prone and standing positions. Twenty healthy subjects were recruited, and NoraxonTeleMyo 2400T was used to collect electromyographic signals from the LT, SA, and ES muscles. A two-way repeated analysis of variance (ANOVA) used a significance level of .05. If a significant interaction was found, pairwise comparisons were performed with a Bonferroni adjustment (.05/4=.013). The results of the study were as follows: 1) In LT, no significant ADIM by position interaction was found ($F_{1,19}$=.356, p=.558). There was a significant main effect for ADIM. LT muscle activity with ADIM was significantly greater compared with muscle activity without ADIM ($F_{1,19}$=82.863, p<.001). There was also a significant main effect for position. LT muscle activity in the prone position was greater compared with muscle activity in the standing position ($F_{1,19}$=116.401, p<.001). 2) In SA, significant ADIM by position interaction was found ($F_{1,19}$=8.687, p=.008). There were significant differences in all pairwise comparisons. The greatest SA muscle activity was observed in the standing position with ADIM. 3) In ES, significant ADIM by position interaction was found ($F_{1,19}$=122.473, p<.001). The lowest ES muscle activity was elicited in the standing position with ADIM. Based on these results, ADIM is advocated in the prone position to increase LT muscle activity. In addition, it is concluded that arm lifts in the standing position with ADIM offer the most favorable combination for reducing ES muscle activity and increasing SA muscle activity.

Comparative Analysis of the Serratus Anterior Muscle Activity When Right and Left Knee Lift during Quadruped Position on Push Up Plus

  • Nam, KiSeok;Kim, JiWoong;Park, JiWon
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.1
    • /
    • pp.58-63
    • /
    • 2020
  • Purpose: This study examined the effects of the right or left knee lift during push up plus in the quadruped position on the serratus anterior (SA) muscle activity. Methods: Twenty-one subjects (male 11, female 10) performed the quadruped position on push up plus. The muscle activities of the lower trapezius (LT), SA, and upper trapezius (UT) were measured by surface electromyography. Repeated measurements of one-way ANOVA were performed for statistical analysis of the data, and the criterion for statistical significance was set to p<0.05 and comparative analysis of the UT and SA ratio using a Paired t-test. Results: The right SA increased the muscle activity of the right knee lift during quadruped position push up plus (p<0.05). In particular, the right SA muscle activity was higher than the left. In addition, comparative analysis of the UT and SA ratio to the right knee lift during quadruped position push up plus was performed (p<0.05). The right was found to be a significant statistic compared to the left, but the left SA increased the muscle activity of the left knee lift during quadruped position push up plus (p<0.05). The left SA muscle activity was higher than right. In addition, comparative analysis of UT and SA ratio to the left knee lift during quadruped position push up plus was performed (p<0.05). The left was found to be a significance statistic than the right. In addition, the interaction effect between the groups showed significant differences (p<0.05). Conclusion: Knee lift during push up plus is recommended for the selective activation of a research exercise protocol of one side of the serratus anterior.

Development of Surface Acoustic Wave Biosensor Using Epitaxial Lift-Off(ELO) Technology (ELO 기술을 이용한 표면 탄성파 바이오 센서의 개발)

  • 김기범;정우석;권대규;김남균;홍철운
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.447-449
    • /
    • 2004
  • The purpose of this study is measured surface acoustic wave(SAW) characteristics to confirm utilization possibility as SAW sensor using new Pb(Mg$_{1}$3/Nb$_{2}$3/) $O_3$-PbTiO$_3$ (PMN-PT) piezoelectric substrate. We have tried to see if the material can be practically available as a new surface acoustic wave (SAW) biosensor to detect protein. The experimental results clarified that the frequency filtering of the central frequency of the PMN-PT substrate is a superior result to that of the LiTaO$_3$ (LT) substrate, but the result was not completely satisfactory. We know there is a problem in the design of inter-digital transducer (IDT) pattern. The waves transferred through the input terminal forms SAW which is sure to be transferred to the direction of the output terminal and the backward direction of the input terminal. This reflected wave is reiterated with SAW, which is transferred to the output direction, and so the frequency filtering gives a not good result. The electromechanical coupling coefficient of the PMN-PT substrate is excellent, and we can use it as a SAW sensor, in the near future, provided that there will be a new IDT design to increase the frequency filtering.

  • PDF