• 제목/요약/키워드: Life tube

검색결과 449건 처리시간 0.035초

Growth Inhibition and Apoptosis Induction of Human Umbilical Vein Endothelial Cells by Apogossypolone

  • Zhan, Yong-Hua;Huang, Xiao-Feng;Hu, Xing-Bin;An, Qun-Xing;Liu, Zhi-Xin;Zhang, Xian-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1791-1795
    • /
    • 2013
  • Aims and Background: Prostate cancer is one of the most common malignant tumors in the male reproductive system, which causes the second most cancer deaths of males, and control of angiogenesis in prostate lesions is of obvious importance. This study assessed the effect of apogossypolone (ApoG2) on proliferation and apoptosis of human umbilical vein endothelial cells (HUVECs). Subjects and Methods: HUVECs were treated with different concentrations of ApoG2. The survival rate of HUVECs were determined by MTT assay. Utrastructural changes of HUVECs were assessed with transmission electron microscopy. Apoptosis in HUVECs was analyzed by flow cytometry and cell migration by Boyden chamber assay. Matrigel assays were used to quantify the development of tube-like networks. Results: ApoG2 significantly inhibited HUVEC growth even at 24 h (P<0.05). The inhibitory effect of ApoG2 is more obvious as the concentration and the culture time increased (P<0.05). These results indicate that ApoG2 inhibits the proliferation of HUVECs in a time- and concentration-dependent manner with increase of the apoptosis rate. Besides, ApoG2 reduced the formation of total pseudotubule length and network branches of HUVECs. Conclusions: The results suggest that ApoG2 inhibits angiogenesis of HUVECs by growth inhibition and apoptosis induction.

식물생장용 저압챔버 내의 기온, 상대습도 및 압력의 변화 (Variations of Air Temperature, Relative Humidity and Pressure in a Low Pressure Chamber for Plant Growth)

  • 박종현;김용현
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.200-207
    • /
    • 2009
  • This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by $0.21kPa{\cdot}h^{-1}$, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by $1.03kPa{\cdot}h^{-1}$. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.

Echinostoma macrorchis (Digenea: Echinostomatidae): Metacercariae in Cipangopaludina chinensis malleata Snails and Adults from Experimental Rats in Korea

  • Sohn, Woon-Mok;Na, Byoung-Kuk
    • Parasites, Hosts and Diseases
    • /
    • 제55권5호
    • /
    • pp.541-548
    • /
    • 2017
  • A survey was performed to know the infection status of echinostome metacercariae in Cipangopaludina chinensis malleata snails from Korea. Total 75 snails collected in 5 localities, i.e., Imsil-gun, Jeollabuk-do, Hwasun-gun and Shinan-gun (Aphae and Jido), Jeollanam-do, and Jinju-si, Gyeongsangnam-do, were examined for metacercariae by the artificial digestion method. Infection rates of metacercariae were 80.0%, 66.7%, 100%, 60.0%, and 73.3%, and their densities were 39, 32, 183, 19, and 30 per snail infected, respectively. The metacercariae were round, $105-118{\times}105-118{\mu}m$ in size, with a thin cyst wall, collar spines on the head collar, and excretory granules in 2 canals of excretory tube. Adult flukes were elongated, ventrally curved, and $5,167{\times}939{\mu}m$ in average size. Head collar distinct, bearing 45 collar spines with 5 end groups on each side. Oral sucker subterminal, pharynx well developed, and esophagus somewhat short. Cirrus sac well developed, with a saccular seminal vesicle, and ventral sucker very large. Ovary elliptical and on the median line of the body. Testes tandem and slightly lobed. Eggs operculated, elliptical, and $90-103{\times}55-60{\mu}m$ in size. By scanning electron microscopy, the head collar was prominent with 45 collar spines resembling horns of younger stags. Scale-like tegumental spines were densely distributed on the body surface between the head collar and ventral sucker. Conclusively, it has been first confirmed that the life cycle of E. macrorchis is indigenously maintained in Korea, and C. chinensis malleata snails are popularly infected with the metacercariae of this echinostome.

국내 경북지역 소에서 분리된 브루셀라 분리주의 생물학적 특성 (Biological characterization of Brucella spp. isolated from cattle in Gyeongbuk, Korea)

  • 김정화;임정주;김동혁;이진주;김대근;전무형;김상훈;장홍희;이후장;민원기;김석
    • 대한수의학회지
    • /
    • 제50권2호
    • /
    • pp.117-124
    • /
    • 2010
  • Members of the genus Brucella are facultative intracellular bacteria and cause brucellosis, a chronic disease in humans and abortion in animals. In this study, we tested sera for brucellosis of 15 Hanwoo farms in the western part of Gyeong-buk province, resulting 5 farms were brucellosis positive in 2008. We collected blood from 277 heads in the brucellosis positive 5 farms, and performed serological diagnosis, brucella positive cattle which had shown higher than 200 antibody titer in tube agglutination test were slaughtered, supramammary lymph nodes were collected, and Brucella spp. wild type isolation and identification were performed. From these results, 15 of Brucella spp. wild type strains were isolated and all strains were identified as B. abortus biotype 1 by biological and molecular analysis. In the antimicrobial susceptibility test, all 15 strains had a similar susceptibility and resistance pattern. This study may be useful for bacteriological and epidemiological understanding of cattle brucellosis in Korea.

소형챔버를 이용한 드라이클리닝 모직물 목도리의 휘발성유기화합물 방출 특성 (VOC Emission Characteristics of Dry Cleaned Wool Scarfs through Small Chamber Test)

  • 신진호;권승미;김현수;노방식;김광래;어수미;정권;이영규
    • 한국환경보건학회지
    • /
    • 제43권2호
    • /
    • pp.95-102
    • /
    • 2017
  • Objectives: This study was conducted to evaluate the emission of VOCs from clothing that had been dry cleaned. Methods: In order to ensure the same conditions, f100% wool scarves were selected as the fabric type. Four identical tests were conducted on the option of either removing the plastic bags which came from the dry cleaning shop or not. The scarf was located inside a closet or room for one or two days. Small chamber tests were conducted to determine the VOC emission characteristics under the same conditions such as temperature, humidity, loading factor, and air exchange rates. Air from the chamber for VOCs was sampled by Tenax TA tube and analyzed by thermal desorption and GC/MSD. Results: Assuming that test represented dry cleaning and consumer's conditions well enough, we can conclude that immediate emissions after the dry cleaning of the scarfs caused elevated levels of TVOC, five VOCs (benzene, toluene, ethylbenzene, xylene, stylene), and decane group compounds. Conclusions: By removing the plastic bags which came from the dry cleaning shop or not, the storage conditions of dry cleaned scarfs by consumers during the storage time periods (one to three days) would be significant for reducing VOC emissions.

미소시험편을 이용한 고온 크리프 특성 평가법 개발 (Development of High Temperature Creep Properties Evaluation Method using Miniature Specimen)

  • 유효선;백승세;이송인;하정수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.43-48
    • /
    • 2000
  • In this study, a small punch creep(SP-Creep) test using miniaturized specimen$(10{\times}10{\times}0.5mm)$ has been described for the development of the newly semi-destructive creep test method for high temperature structural components such as headers and tubes of boiler turbine casino and rotor and reactor vessel. The SP-Creep testing technique has been applied to 2.25Cr-1Mo(STBA24) steel used widely as boiler tube material and the creep test temperature are varied at $550^{\circ}C{\sim}600^{\circ}C$. The overall deformations of SP-Creep curves are definitely depended with applied load and creep test temperature and show the creep behaviors of three steps like conventional uniaxial creep curves. The steady state creep rate${\delta}_{ss}$ of SP-Creep curve for miniaturized specimen increases with increasing creep temperature, but the exponential value with creep loading is decreased. The activation energy$(Q_{spc})$ during SP-Creep deformation with various test temperatures shows 605.7kJ/mol that is g.eater than 467.4kJ/mol reported in uniaxial creep test. This may be caused by the difference of stress states during creep deformation In two creep test. But from the experimental results, e.g. SP-Creep curve behaviors, the steady state creep rate${\delta}_{ss}$ with creep temperature, and the exponential value(n) with creep loading, it can be summarized that the SP-Creep test may be a useful test method to evaluate the creep properties of the heat resisting material.

  • PDF

호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술 (Respiratory air flow measuring technique without sensing element on the flow stream)

  • 이인광;박준오;이수옥;신은영;김경천;김경아;차은종
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Sp-Creep 시험에 의한 고온 크리프 특성 평가 기술 개발(ll) - 보일러 헤더 - (Development of Evaluation Technique of High Temperature Creep Characteristics by Small Punch-Creep Test Method (ll) - Boiler Header -)

  • 백승세;이동환;하정수;유효선
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.55-60
    • /
    • 2002
  • For the development of a new creep test technique, the availability of SP-Creep test is discussed for 1Cr-0.5Mo boiler header material. And some results are also compared with those of 2.25Cr- 1Mo steel which widely uses as boiler superheater tube. The results can be summarized as follows. The load exponents(n) obtained by SP-Creep test for 1Cr-0.5Mo steel are decreased with increasing creep temperature and the values are 15.67, 13.89, and 17.13 at 550$^{circ}C$ ,575$^{circ}C$ and 600$^{circ}C$, respectively. The temperature dependence of the load exponent is given by n = 107.19 - 0.1108T. This reason that load exponents show the extensive range of 10∼16 is attributed to the fine carbide such as M$_{23}$C$_{6}$ in lath tempered martensitic structures. At the same creep condition, the secondary creep rate of 1Cr-0.5Mo steel is lower than the 2.25Cr-1Mo steel1 due to the strengthening microstructure composed by normalizing and tempering treatments. Through a SEM observation, it can be summarized that the primary, secondary, and tertiary creep regions of SP-Creep specimen are corresponding to plastic bending, plastic membrane stretching, and plastic instability regions among the deformation behavior of four steps in SP test, respectively.y.

차량용 중공 스테빌라이저바의 내측 쇼트피닝 효과 (Effect of Inner Shot Peening Process for Tubular Stabilizer Bars)

  • 서유원;서진원;이원기;김진영
    • 대한기계학회논문집A
    • /
    • 제41권11호
    • /
    • pp.1119-1124
    • /
    • 2017
  • 차량 하부에 장착된 스테빌라이저바는 차량이 곡선 구간을 선회할 때 차량의 자체를 유지해 줌으로서 차량 주행을 보다 편안하게 해 준다. 스테빌라이저바는 중실과 중공 타입 2가지가 있으며, 차량의 경량화를 위해 중공 형태의 스테빌라이저바의 적용이 늘고 있다. 차량의 경량화를 위한 중공 스테빌라이저바는 중실에 비해 무게가 34% 이상 경량화가 가능하지만 경량화 비율이 높아질수록 제품의 내구 수명은 급격하게 감소하는 경향을 나타낸다. 이러한 내구 수명 감소에 대한 대책으로서 소재의 고강도 및 고경도 소재를 적용하거나 쇼트피닝 공법을 개선 하는 등의 노력을 통해 내구 수명을 보장할 수 있다.

진행된 담도암의 경관조사 (Transcatheter Irradiation of Advanced Extrahepatic Biliary Tract Carcinoma)

  • 김경애;김성규;신세원;김명세;송선교;권굉보
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.173-176
    • /
    • 1987
  • 담도암은 서서히 자라며 원격전이가 늦은데 비하여 완전절제가 어렵고 수술 후 재발율이 높아. 생존율은 매우 낮다. 많은 예에서 국소치료의 실패가 치료실패의 요인으로 밝혀짐에 따라 술후 방사선 치료의 중요성이 인정되어 왔다. 외부방사선치료 만으로는 충분한 선량을 조사할 수 없으므로 국소적인 고선량치료법으로서 술중방사선치료, 간질방사선치료 (interstitial irradiation), 경관방사선치료(transcatheter irradiation) 등이 사용되고 있으나 경관방사선치료의 보고는 드물다. 영남대학병원 치료방사선과에서는 진행된 담도암 1예에서 암 종괴의 부분절제 후 삽입된 T-자관을 통하여 고선량 방사선 치료를 실시하였기에 문헌고찰과 함께 보고하는 바이다.

  • PDF