• 제목/요약/키워드: LiBr/water

검색결과 112건 처리시간 0.023초

Numerical Analysis of Vertical Plate Absorber for Optimal Design

  • Yoon, Jung-In;Moon, Choon-Geun;Phan, Thanh-Tong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.252-262
    • /
    • 2004
  • A model of simultaneous heat and mass transfer process in absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber. which was considered to the change of refrigerant vapor pressure along the plate width direction. was developed to evaluate the compactness of plate absorber and supply basis data for optimal design of plate absorber. The effects of plate interval as well as the effect of capacity for one piece of plate absorber on plate absorber size such as plate height. plate heating area and plate absorber volume have been investigated. It is confirmed that there is exist an optimal plate interval minimizing plate absorber volume. And the smaller capacity for one piece of plate absorber. the smaller plate absorber volume is obtained.

내면가공 핀튜브 흡수기의 열 및 물질전달특성 (Characteristic of Heat and Mass Transfer on Inner Ribbed Notched Fin Tube Absorber)

  • 설원실;권오경;문춘근;정용옥;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.478-485
    • /
    • 2000
  • An experimental study of the absorption process of water vapor into lithium bromide solution was performed. For the purpose of development of high performance absorption chiller-heater utilizing Lithium Bromide solution as working fluid, the absorber is the most effective to improve the performance of an absorber because it requires the largest heat transfer area in an absorption chiller-heater system. This paper introduces bare tube and inner ribbed notched fin tube for the absorber of absorption chiller-heaters. Inner ribbed notched fin tube has about 10∼20% higher heat and mass transfer performance than bare tube conventionally used in absorbers and the it is expected to perform high heat and mass transfer. This paper will provide important information on the selection of absorber tubes in commercial absorption chill-heaters.

  • PDF

공냉식 수직 흡수기의 열전달에 미치는 계면활성제의 영향 (Influence of surfactant on heat transfer of air-cooled vertical absorber)

  • 윤정인;권오경;문춘근
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.740-748
    • /
    • 1999
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare inner surface, groove inner surface, corrugated inner surface and spring inserted inner surface tubes. The additive concentration was about 0.08 mass%. The heat transfer coefficient was measured as a function of film Reynolds number in the range of 20~200. Experiments were tarried out at higher cooling water temperature of $35^{\circ}C$ to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect which was generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an inserted spring has the highest enhancement effect.

  • PDF

Modeling of Pressure Drop for Water Vapor Flow across Tube Banks inside Horizontal Tube Absorber

  • Phan Thanh Tong;Yoon Jung-In;Kim Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.483-493
    • /
    • 2006
  • A model for a pressure drop of water vapor flow across tube banks in a horizontal tube absorber of an absorption chiller/heater using LiBr solution as a working fluid has been developed based on a commercial 20RT(70kW) absorption chiller/heater. The numerical results show that the characteristic of the pressure drop in the shell side of the horizontal tube absorber is completely different from that in a conventional shell and tube heat exchanger. Especially, solution film thickness has significant influence on the vapor pressure drop in the horizontal tube absorber. In addition, the effects by the tube diameters, the longitudinal pitch to diameter ratio, and Reynolds number of the vapor flow, on the vapor pressure drop have been studied to evaluate the compactness of tube absorber. It was found that the vapor pressure drop decreases as tube diameter increases, the longitudinal pitch to diameter ratio increases, and Reynolds number of the vapor flow decreases. A comparison of the present study results with well-established experimental and numerical results showed a good overall agreement.

중온수 흡수식 냉동기의 열전달 면적 최적화 (Optimization of Heat Transfer Area Distribution for a Hot Water Driven Absorption Chiller)

  • 정시영;조광운;이상수
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.431-438
    • /
    • 2000
  • The major irreversibilities in absorption chillers are associated with the transfer of heat into and out from the machine and irreversible process inside the machine. By modeling only external irreversibilities(endo-reversible), a model was formulated to predict the ideal performance of a single-effect absorption chiller. Its actual performance including both external and internal irreversibilities was calculated with a in-house simulation program. The optimization of heat transfer area distribution was performed for both endo-reversible cycle and actual cycle. The equation of endo-reversible modeling was found to give about 2times higher cooling capacity than the simulation program. At optimal distribution, it was found that heat transfer area of the evaporator was about 30% of total area, that of the generator was 20%, and the rest 50% was for the absorber and condenser. The system COP for endo-reversible cycle was slightly higher than that for actual cycle. In the case of LiBr-water single-effect absorption chiller, the maximum cooling capacity was obtained near the condition that LMTD is same at all heat exchangers.

  • PDF

수직관내 리튬브로마이드 수용액막의 흡수과정에 대한 비흡수가스의 영향 (Effects of Non-Absorbable Gases on the Absorption Process of Aqueous LiBr Solution Film in a Vertical Tube (II))

  • 김병주;이찬우
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.499-509
    • /
    • 1998
  • In the absorption process of water vapor in a liquid film, the composition of the gas phase, in which a non-absorbable gas is combined with the absorbate influences the transport characteristics remarkably. In the present study, the absorption processes of water vapor into aqueous solution of lithium bromide in the presence of non-absorbable gases were investigated analytically. The continuity, momentum, energy and diffusion equations for the solution film and gas phase were formulated in integral forms and solved numerically. It was found that the mass transfer resistance in gas phase increased with the concentration of non-absorbable gas. However the primary resistance to mass transfer was in the liquid phase. As the concentration of non-absorbable gas in the absorbate increased, the liquid-vapor interfacial temperature and concentration of absorbate in solution decreased, which resulted in the reduction of absorption rate. The reduction of mass transfer rate was found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of an absorber where non-absorbable gases accumulated. At higher non-absorbable gas concentration, the decrease of absorption flux was almost linear to the volumetric concentration of non-absorbable gas.

Experimental Investigation of Heat Transfer in Absorber with Small Diameter Tube

  • Phan Thanh Tong;Moon Choon-Geun;Kim Jae-Dol;Yoon Jung-In
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.261-262
    • /
    • 2006
  • The effect of tube diameter on heat transfer characteristics of absorber in absorption chiller/heater using LiBr solution as a working fluid has been investigated by experimental study to develop a high performance and compact absorber. A system Includes a tube absorber, a generator, solution distribution system and cooling water system was set up. The diameter of the heat exchanger tube inside absorber was changed from 15.88mm to 12.7mm and 9.52mm. The experimental results show that the heat transfer coefficient, Nusselt number and heat flux increase as solution flow rate and cooling water flow rate increase. The heat transfer performance increases as tube diameter decreases. Among three different tube diameters, the smallest tube diameter 9.52mm has highest heat transfer performance. A comparison of the heat transfer coefficient obtained by the present study with those of previous experimental results showed good overall agreement.

  • PDF

수평관 외벽에서 친수성 표면처리가 응축열전달에 미치는 영향 (Effects of Hydrophilic Surface Treatment on Condensation Heat Transfer at the Outside Wall of Horizontal Tube)

  • 황규대;박노성;강병하
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.533-540
    • /
    • 2000
  • Condensation heat transfer characteristics have been investigated experimentally when a water vapor is condensed on the outside of a horizontal copper tube in a condenser. This problem is of particular interest in the design of a LiBr-water absorption system. Hydrophilic surface modification was performed to increase the wettability on the copper tube. The optimum hydrophilic treatment condition using acethylene and nitrogen as reaction gas is also studied in detail. The results obtained indicate that the optimum reaction gas ratio of acethylene to nitrogen for hydrophilic surface modification was found to be 7 : 3 for the best condensation heat transfer. In the wide ranges of coolant inlet temperatures, and coolant mass flow rates, both the condensation heat transfer rate and the condensation heat transfer coefficient of a hydrophilic copper tube are increased substantially, compared with those of a conventional copper tube used in a condenser. It is also found that the condensation heat transfer enhancement by the hydrophilic surface modification still emains even after a hundred cycles of wet/dry processes.

  • PDF

응축기 배열 회수에 의한 흡수식 냉동기의 고효율화에 관한 연구 (A study on the Characteristics of the High Efficiency absorption Chiller by Heat Recovering from Condenser)

  • 박찬우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.46-51
    • /
    • 2006
  • In order to utilize the refrigerants condensation heat of condenser on the absorption chiller system, the solution cooling condenser(SCC) were proposed, which weak solution of absorber outlet use as a cooling water. As the UA of the solution cooling condenser increased, increasement of COP is about maximum 0.09 in occasion of single effect and is about maximum 0.08 in occasion of double effect series flow. In the case of heat exchanger efficiency is about 0.85, it's increments are 0.08 and 0.072, each. And solution cooling condenser is a more effective device in the single effect absorption system more than double effect system for the principle of operation. In order to increases the heat of solution cooling condenser, if reduce the flow rate of cooling water or the value of UA, it makes COP increase a little, but it brought COP decrease because of increasing the pressure of system.

  • PDF

Phenyl 고리를 갖는 고분자 겔의 팽윤거동에 대한 이온 특성화 효과 (Effects of Ion Specificity on the Expansion Behavior of Polymer Gel with Phenyl Ring)

  • 안범수
    • 한국응용과학기술학회지
    • /
    • 제29권2호
    • /
    • pp.278-285
    • /
    • 2012
  • 낮은 농도와 높은 농도의 염 용액에서 Poly(styrene sulfonic acid)(PSSA) 겔의 팽윤도에 대한 이온 특성화 효과를 ${SO_3}^-$와 페닐 고리의 수소결합을 통하여 조사하였다. 낮은 농도에서 PSSA 수화 겔의 수축 정도는 ${SO_3}^-$와 물 사이의 수소 결합에 대한 음이온의 불안정화 영향 때문에 음이온에서는 $SCN^-$<$Br^-$<$Cl^-$<$F^-$의 순서를 따랐다. 재 팽윤은 계에서 특별한 상호 작용이 있을 때 높은 농도에서 관찰되었다. 반면 양이온에서 PSSA 겔의 수축은 $Li^+$<$Na^+$<$K^+$<$Ca^{+2}$ 순서를 따랐다. $Ca^{+2}$ 이온에서의 큰 수축 효과는 이가 양이온(+2)에 의한 PSSA 겔의 물리적 가교 때문에 나타난 것으로 보인다. 양이온에서의 수축은 ${SO_3}^-$와 양이온 사이의 상호작용 정도에 비례하였다. PSSA의 팽윤에 대한 이온 특성화 효과는 ${SO_3}^-$와 페닐 고리의 수화 수소결합에 대한 이온의 영향 정도, 양이온과 ${\pi}$ 전자의 상호작용, 소수성 상호작용, 그리고 분산력 등이 복합적으로 작용하여 나타난다고 볼 수 있다.