• 제목/요약/키워드: Level breakdown point

검색결과 23건 처리시간 0.026초

무근 콘크리트에서 균열 발생원 탐사를 위한 AE 기법의 적용 (Application of Acoustic Emission Technique for Crack Source Location Search in Plain Concrete)

  • 한상훈;이웅종;조홍동;김동규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.793-798
    • /
    • 1999
  • This study was conducted to evaluate structural integrity and crack source location of plain concrete beams using acoustic emission. Three point bending tests were carried out plain concrete specimen under cyclic loadings. The variable is W/C of concrete. From the tests it was shown that a breakdown of the kaiser effect and high AE activities during unloading could be effective indices to estimate the level of deterioration in plain concrete structures. The time and location and propagation of crack could be easily determined by monitoring AE, which concludes that AE technique can be a very useful tool to evaluate structural integrity of concrete plain beams.

  • PDF

윤활기유의 조성이 전기절연유의 성능 및 특성에 미치는 영향 (The Effect of Base Oil Composition on Electronic Insulating Oil's Performances)

  • 문우식;전정식
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.181-189
    • /
    • 1998
  • In order to investigate the effect of base oil composition on the electronic insulating oil's performances, an experimental study has been conducted using different oils. Owing to their properties, like lower pour point and gas absorbing, naphthenic base oils are used more often than paraffmic base oils for the electronic insulating oil application. Naphthenic and paraffinic base oils are significantly different in their aromatic hydrocarbon content. In this paper, PXE(para xylyl ethane), LAB(linear alkylbenzene), C13 aromatic hydrocarbon mixture and C17 aromatic hydrocarbon mixture are investigated regarding their influence on insulating oil's performances. According to present study, breakdown voltage decreased with increasing aromatic lydrocarbon content in a deep dewaxed paraffmic base oil. However, any changing in the dissipation factor was not recognizable at small treated level. Furthermore, the volume resistance was not influenced by aromatic hydrocarbon content. The gassing tendency was found as a highly sensible property, changing with treating aromatic hydrocarbons. The higher benzene ring content in the hydrocarbon, the better gassing tendency.

  • PDF

옥외용 실리콘 애자의 산성비중 질산이온에 의한 열화특성 연구 (An experimental investigation on the characteristics of the outdoor silicone rubber insulator due to nitrate ion of acid rain)

  • 김인태;이정헌;김정태;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.196-199
    • /
    • 1996
  • In this paper, aging characteristics of outdoor silicone rubber insulator resulting from the acid rain have been investigated with regards to nitrate ion ($NO_3$). For this purpose, silicone rubber was aged by immersing into the nitric solutions with different level ph during 1500 hours and various tests(tracking, contact angle, $tan{\delta}$, breakdown voltage, SEM, EDS, FT-IR) were performed. It was observed that the degradation was increased to ph 2.5 slightly and highly at ph 1.5. And thus, it could be expected that there is certain critical point between ph 1.5 and 2.5, which leads to throught degradation.

  • PDF

반밀폐형 온실 내에서 탄산가스 시비에 따른 광강도와 엽온에 반응한 토마토 잎의 최대 카복실화율, 전자전달율 및 광합성율 실측값과 모델링 방정식에 의한 예측값의 비교 (Comparison of Measured and Calculated Carboxylation Rate, Electron Transfer Rate and Photosynthesis Rate Response to Different Light Intensity and Leaf Temperature in Semi-closed Greenhouse with Carbon Dioxide Fertilization for Tomato Cultivation)

  • 최은영;정영애;안승현;장동철;김대현;이동수;권진경;우영회
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.401-409
    • /
    • 2021
  • 본 연구는 반밀폐형 토마토 재배 온실에서 광합성율 극대화를 위한 적정 탄산가스 시비 농도를 구명하고자 광합성 모델을 이용하여 잎의 최대 카복실화율(Vcmax), 최대 전자전달속도(Jmax), 열파괴, 잎 호흡 등을 계산하고 실제 측정값과 비교하였다. 다양한 광도(PAR 200µmol·m-2·s-1 to 1500µmol·m-2·s-1)와 온도(20℃ to 35℃) 조건에서 CO2 농도에 대한 A-Ci curve는 광합성 측정 기기를 사용하여 측정하였고, 모델링 방정식으로 아레니우스 함수값(Arrhenius function), 순광합성율(net CO2 assimilation, An), 열파괴(thermal breakdown), Rd(주간의 잎호흡)를 계산하였다. 엽온이 30℃ 이상으로 상승하였을 때 Jmax, An 및 thermal breakdown 예측치가 모두 감소하였고, 예측 Jmax의 가장 최고점은 엽온 30℃였으며 그 이상의 온도에서는 감소하였다. 생장점 아래 5번째 잎의 광합성율은 PAR 200-400µmol·m-2·s-1 수준에서는 CO2 600ppm, PAR 600-800µmol·m-2·s-1 수준에서는 CO2 800ppm, PAR 1000µmol·m-2·s-1 수준에서는 CO2 1000ppm, PAR 1200-1500µmol·m-2·s-1 수준에서는 CO2 1500ppm을 공급했을 때 포화점에 도달하였다. 앞으로 광합성 모델식을 활용하여 과채류 온실 재배 시 광합성을 높일 수 있는 탄산시비 농도를 추정할 수 있을 것으로 판단된다.

비교사례 연구를 통한 인프라 유지관리 기술 분류체계 도출 (Identification of Breakdown Structure for Infrastructure Maintenance, Repair, and Rehabilitation Technologies using Comparative Case Study)

  • 김두연;차용운;박원영;박태일
    • 한국산학기술학회논문지
    • /
    • 제21권10호
    • /
    • pp.248-258
    • /
    • 2020
  • 본 연구에서는 해외 선진국의 유지관리 체계를 벤치마킹하여 시설물의 생애주기 차원에서 종합적 자산 관리개념을 고려한 유지관리 기술 분류체계를 제안하였다. 이를 위하여 비교사례 연구 기법을 적용하였으며, 국내·외 유지관리 제도, 정의, 기술 분류체계 등을 비교·분석하였다. 비교사례 분석을 위하여 유지관리 비용 집행 비율이 높은 미국, 영국, 일본을 대상 국가로 선정하였고, 해당 국가들의 유지관리 체계를 분석하였다. 다음으로, 국내 유지관리 관련 법에 내포되어있는 인프라 유지관리 기술의 분류 및 정의에 대하여 분석하였다. 그 결과 해외 선진국들은 유지관리 기술의 효과에 따라 유지보수와 개선을 명확하게 분류하고, 예방적 유지관리 활동 중심의 체계를 구성하고 있었다. 반면, 우리나라의 시설물 유지관리 기술은 그 분류 및 정의가 명확하게 구분되지 않고 아직도 사후 대응적 구조 중심으로 이루어져 있어 개선이 필요한 것으로 나타났다. 비교사례연구 결과를 토대로 제안한 분류체계는 유지관리, 유지보수, 성능개선의 개념을 정립하고, 예방적 유지보수와 대응적 유지보수를 명확하게 구분하였다. 결과적으로 제안된 기술 분류체계는 자산관리관점에서 선제적 유지관리 활동과 합리적인 유지관리 예산 분배를 위한 기초연구로서의 활용도가 높을 것으로 기대된다.

4H-SiC PiN 다이오드의 깊은 준위 결함에 따른 전기적 특성 분석 (Analysis of Electrical Characteristics due to Deep Level Defects in 4H-SiC PiN Diodes)

  • 이태희;박세림;김예진;박승현;김일룡;김민규;임병철;구상모
    • 한국재료학회지
    • /
    • 제34권2호
    • /
    • pp.111-115
    • /
    • 2024
  • Silicon carbide (SiC) has emerged as a promising material for next-generation power semiconductor materials, due to its high thermal conductivity and high critical electric field (~3 MV/cm) with a wide bandgap of 3.3 eV. This permits SiC devices to operate at lower on-resistance and higher breakdown voltage. However, to improve device performance, advanced research is still needed to reduce point defects in the SiC epitaxial layer. This work investigated the electrical characteristics and defect properties using DLTS analysis. Four deep level defects generated by the implantation process and during epitaxial layer growth were detected. Trap parameters such as energy level, capture-cross section, trap density were obtained from an Arrhenius plot. To investigate the impact of defects on the device, a 2D TCAD simulation was conducted using the same device structure, and the extracted defect parameters were added to confirm electrical characteristics. The degradation of device performance such as an increase in on-resistance by adding trap parameters was confirmed.

Negative Exponential Disparity Based Deviance and Goodness-of-fit Tests for Continuous Models: Distributions, Efficiency and Robustness

  • Jeong, Dong-Bin;Sahadeb Sarkar
    • Journal of the Korean Statistical Society
    • /
    • 제30권1호
    • /
    • pp.41-61
    • /
    • 2001
  • The minimum negative exponential disparity estimator(MNEDE), introduced by Lindsay(1994), is an excellenet competitor to the minimum Hellinger distance estimator(Beran 1977) as a robust and yet efficient alternative to the maximum likelihood estimator in parametric models. In this paper we define the negative exponential deviance test(NEDT) as an analog of the likelihood ratio test(LRT), and show that the NEDT is asymptotically equivalent to he LRT at the model and under a sequence of contiguous alternatives. We establish that the asymptotic strong breakdown point for a class of minimum disparity estimators, containing the MNEDE, is at least 1/2 in continuous models. This result leads us to anticipate robustness of the NEDT under data contamination, and we demonstrate it empirically. In fact, in the simulation settings considered here the empirical level of the NEDT show more stability than the Hellinger deviance test(Simpson 1989). The NEDT is illustrated through an example data set. We also define a goodness-of-fit statistic to assess adequacy of a specified parametric model, and establish its asymptotic normality under the null hypothesis.

  • PDF

154kV 혼합송전선로 재폐로 결정에 관한 연구 (A Study on Reclosing Decision on 154kV Combined Transmission Lines)

  • 정채균;박흥석;강지원;이종범
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1761-1769
    • /
    • 2010
  • This paper describes switching surge analysis on reclosing decision in 154kV combined transmission line with power cables. Reclosing should be operated in combined transmission line based on the technical evaluation because of insulation problem of power cable section. If the surge strikes on power cable, the breakdown can occur at week point of cable insulation. Therefore the detailed analysis is required by considering several conditions such as length ratio of power cable, arrester, fault resistance, charging rate and grounding resistance, etc.. In addition, sheath voltage on IJ(Insulated Joint) is analyzed to confirm the protective level. Simulation is performed by EMTP/ATP. Analysis results show that reclosing can be operated without any special problem by the single line-to-ground fault with fault resistance of $1\Omega$ to $50\Omega$ occurred at the overhead transmission section in 154kV combined transmission lines and trap charge of 100% and 110%.

6-18 GHz Reactive Matched GaN MMIC Power Amplifiers with Distributed L-C Load Matching

  • Kim, Jihoon;Choi, Kwangseok;Lee, Sangho;Park, Hongjong;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • 제16권1호
    • /
    • pp.44-51
    • /
    • 2016
  • A commercial $0.25{\mu}m$ GaN process is used to implement 6-18 GHz wideband power amplifier (PA) monolithic microwave integrated circuits (MMICs). GaN HEMTs are advantageous for enhancing RF power due to high breakdown voltages. However, the large-signal models provided by the foundry service cannot guarantee model accuracy up to frequencies close to their maximum oscillation frequency ($F_{max}$). Generally, the optimum output load point of a PA varies severely according to frequency, which creates difficulties in generating watt-level output power through the octave bandwidth. This study overcomes these issues by the development of in-house large-signal models that include a thermal model and by applying distributed L-C output load matching to reactive matched amplifiers. The proposed GaN PAs have successfully accomplished output power over 5 W through the octave bandwidth.

GIS내에서 금속이물이 절연파괴에 미치는 영향 (The Effect of Conducting Particles on Breakdown Phenomena in GIS)

  • 김민규;문인옥;김윤택;김익수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1574-1576
    • /
    • 1994
  • $SF_6$ gas has become an important insulation medium in modern electric power apparatus, because of its high insulation withstand levels and good arc quenching capability. For the application of $SF_6$ gas in GIS the estimation of insulation properties is a fundamental point. Moreover the reduction of withstand levels in case of inhomogeneous fields caused by particles or fixed protrusions is of special interest. It is known that the presence of free conducting particles in GIS can significantly lower the insulating level of $SF_6$ gas at elevated pressure and also it has been recently shown that dielectric strength is greatly reduced by fast transients such as disconnector surges where metallic particles are involved. In this paper, we have disigned the particle test chamber rated 362kV for the purpose of investigating the discharge characteristics in SF6 gas where inhomogenius fields are caused by metallic particles.

  • PDF