• Title/Summary/Keyword: LessFS

Search Result 88, Processing Time 0.029 seconds

Validity of Fecal Pollution Source Tracking using FC/FS Ratio (FC/FS 비율에 의한 분변오염원의 출처파악의 유효성)

  • Park, Ji-Eun;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • This study was conducted to assess the validity of fecal coliforms to fecal streptococci ratio (FC/FS) for distinguishing the human from animal origin of fecal pollution in surface water. FC/FS ratio determined in effluent from municipal wastewater and human feces treatment plant (WWTP) and in downstream close to discharge of human feces was above 4 which indicates human origin. However FC/FS ratios determined seasonally in other water zones of the Nakdong River, even in the same sampling site, varied differently (above 4 or less than 0.7) due to different survival time of FC and FS and other environmental factors such as rainfall in watershed. Compared to other season, FC/FS ratios in winter were much lower regardless of the origin. It is concluded that the FC/FS ratio determined in surface water is not always valid for determining the origin of fecal pollution.

Measurement of Atmospheric PCDD/Fs Concentrations Using Polyurethane Foam Disk Passive Air Samplers (폴리우레탄 폼 수동형 공기시료채취기를 이용한 대기 중 다이옥신/퓨란 농도 측정)

  • Kim, Taewook;Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.2
    • /
    • pp.102-111
    • /
    • 2016
  • Objectives: This study was conducted to evaluate the use of polyurethane foam disk passive air samplers (PUF PAS) for better measurement of atmospheric polychlorinared dibenzo-p-dioxins/furans (PCDD/Fs) concentrations compared to PUF PAS combined with high volume air samplers (HVS). Methods: Air samples were collected by a low volume air sampler (LVS) and PUF PAS. A total of two pairs were continuously collected for six months, but the PUF was replaced every two months. Results: A good correlation was shown ($R^2=0.8595$, p<0.0001) between atmospheric PCDD/Fs concentration measured by the LVS and PUF PAS. The average air sampling rate ($1.5m^3/day-sampler$) of all PCDD/Fs congeners showed a middle of the means which were measured using a HVS by other researchers in different cities. In addition, the air sampling rates of the LVS for each congener made less difference than did those of the HVS. Conclusion: It was found that measurements using the LVS were less influenced by atmospheric peak PCDD/Fs concentrations. However, trace POPs such as PCDD/Fs may involve relatively large analytical errors in measurement, and as a result the air sampling rate of the respective PCDD/Fs isomer is also likely to involve errors. The method of using a regression straight line between the concentrations obtained from the LVS and those from the PUF PAS was judged higher than the method using the air sampling rate, since the former compensated for the experimental errors in the process of evaluation of atmospheric PCDD/F concentrations using the PUF PAS.

Pretreatment Method Development of PCDD/Fs in Sediment Using ASE and SPMDs (ASE와 SPMDs를 이용한 퇴적물중 PCDD/Fs의 전처리법 개발)

  • Chun, Man-Young
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.1 s.56
    • /
    • pp.49-55
    • /
    • 2007
  • Three kind of ASE (Accelerated Solvent Extraction) and SPMDs (Semi-Permeable Membrane Devices) combined methods (ASE-SPMDs, ASE-accelerated SPMDs and SPMDs without extraction) and general Soxhlet-GPC were compared each other for the analysis of PCDD/FS in sediment. The average recovery rate of three types ASE and SPMDs combined methods (108.1%) were higher than that of the Soxhlet-GPC (79.5%) for three samples in each method using surrogate internal standards. The average coefficient of variation (10%, $2.1{\sim}25.2%$) for each congener of PCDD/Fs shows the reasonable results. Total PCDD/Fs concentrations after SPMDs without extraction were quite low, but those after ASE-SPMDs and ASE-accelerated SPMDs methods were close to the Soxhlet-GPC. Thus, the ASE-SPMDs and ASE-accelerated SPMDs methods are considered as the excellent pre-treatments method because they need less solvent and time without quality degradation.

Performance Analysis of Open Source Based Distributed Deduplication File System (오픈 소스 기반 데이터 분산 중복제거 파일 시스템의 성능 분석)

  • Jung, Sung-Ouk;Choi, Hoon
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.12
    • /
    • pp.623-631
    • /
    • 2014
  • Comparison of two representative deduplication file systems, LessFS and SDFS, shows that Lessfs is better in execution time and CPU utilization while SDFS is better in storage usage (around 1/8 less than general file systems). In this paper, a new system is proposed where the advantages of SDFS and Lessfs are combined. The new system uses multiple DFEs and one DSE to maintain the integrity and consistency of the data. An evaluation study to compare between Single DFE and Dual DFE indicates that the Dual DFE was better than the Single DFE. The Dual DFE reduced the CPU usage and provided fast deduplication time. This reveals that proposed system can be used to solve the problem of an increase in large data storage and power consumption.

Design of Adaptive Deduplication Algorithm Based on File Type and Size (파일 유형과 크기에 따른 적응형 중복 제거 알고리즘 설계)

  • Hwang, In-Cheol;Kwon, Oh-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.149-157
    • /
    • 2020
  • Today, due to the large amount of data duplication caused by the increase in user data, various deduplication studies have been conducted. However, research on personal storage is relatively poor. Personal storage, unlike high-performance computers, needs to perform deduplication while reducing CPU and memory resource usage. In this paper, we propose an adaptive algorithm that selectively applies fixed size chunking (FSC) and whole file chunking (WFH) according to the file type and size in order to maintain the deduplication rate and reduce the load in personal storage. We propose an algorithm for minimization. The experimental results show that the proposed file system has more than 1.3 times slower at first write operation but less than 3 times reducing in memory usage compare to LessFS and it is 2.5 times faster at rewrite operation.

Comparisons of Teachers' Satisfaction with School Lunch Program in Middle and Elementary Schools run by Foodservice Management Type (초.중등학교 교사의 학교급식 만족도에 대한 위탁운영 및 직영 형태간 비교)

  • 이정원;박양자;박영숙;이미숙
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.3
    • /
    • pp.406-416
    • /
    • 1997
  • Teacher's satisfaction with school lunch programs run by foodservice(FS) management types were surveyed with questionnaire at 5 middle and 4 elementary schools. The 88 middle and 104 elementary school teachers who participated and schools' FS management were of 5 types : self/conventional, contracted/conventional, contracted/commissary and contracted/dosirak delivery. Most teachers knew correctly their schools' present FS management types and thoroughly understood the main reasons for needing school lunch program with proper nutrition, better taste and balanced diets in addition to the first reason its less work than preparing homelunches. Teacher's satisfactions with their present school FS were high in self/conventional and contracted/conventional and was very low in contracted/commissary and contracted/ dosirak Taste, hygiene, nutrition and dining facilities in turn were pointed out to be improved : firstly hygiene in the self and firstly taste in the contracted. Particularly dining-rooms were found to have narrow space, uncomfortable chairs and tables, unclean, and having unpleasant smells. Teachers observed that the overall students' food habits such as eating more various foods and better table manners through that school lunch programs, particularly the self-managed types were improved. Conclusively most teachers emphasized school lunch programs to be continued and preferred self-managed types and contracted/conventional types as the second best in having less work to manage, better, taste, nutrition and hygiene, less cost and better nutrition education in turn. And they thought school founders should handle the finances needed to newly establish or repair the school FD facilities, otherwise provided with the partial aid of student's parents.

  • PDF

High-Robust Relaxation Oscillator with Frequency Synthesis Feature for FM-UWB Transmitters

  • Zhou, Bo;Wang, Jingchao
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.202-207
    • /
    • 2015
  • A CMOS relaxation oscillator, with high robustness over process, voltage and temperature (PVT) variations, is designed in $0.18{\mu}m$ CMOS. The proposed oscillator, consisting of full-differential charge-discharge timing circuit and switched-capacitor based voltage-to-current conversion, could be expanded to a simple open-loop frequency synthesizer (FS) with output frequency digitally tuned. Experimental results show that the proposed oscillator conducts subcarrier generation for frequency-modulated ultra-wideband (FM-UWB) transmitters with triangular amplitude distortion less than 1%, and achieves frequency deviation less than 8% under PVT and phase noise of -112 dBc/Hz at 1 MHz offset frequency. Under oscillation frequency of 10.5 MHz, the presented design has the relative FS error less than 2% for subcarrier generation and the power dissipation of 0.6 mW from a 1.8 V supply.

Development of a High Temperature and Exactitude Pressure Sensors for Superior Environmental Characteristics (내환경성이 우수한 고온.고정밀용 압력센서의 개발)

  • 서정환;백명숙;임창섭
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.13-22
    • /
    • 2002
  • This paper presents characteristics of CrOx thin-film Strain gauge pressure sensors, which were deposited on SUS630 diaphragm by DC reactive magnetron sputtering in an argon-Oxide atmosphere(Ar-(10%)$O_2$). The optimized condition of CrOx thin-film strain gauges were thicknessrange of 2500$\AA$ and annealing condition ($350^{\circ}C$, 3 hr) in Ar-10 %$O_2$deposition atmosphere. Under optimum conditions, the CrOx thin-films for strain gauge is obtained a high resistivity, $\rho$=156.7$\mu$$\Omega$cm, a low temperature coefficiect of resistance, TCR=-86 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal, 15. The output sensitivity of pressure sensor obtained is 2.46㎷/V and the maximum non-linearity is 0.3%FS and hysteresis is less than 0.2%FS. The output characteristics of pressure transmitter obtained is 4~20㎃ and total accuracy is less than $\pm$0.5%FS. In those conclusions, CrOx thin film pressure sensors is quite satisfactory for many applications in industrial electronics.

  • PDF

Enamel pretreatment with Er:YAG laser: effects on the microleakage of fissure sealant in fluorosed teeth

  • Memarpour, Mahtab;Kianimanesh, Nasrin;Shayeghi, Bahareh
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.180-186
    • /
    • 2014
  • Objectives: The purpose of this in vitro study was to evaluate the microleakage and penetration of fissure sealant in permanent molar teeth with fluorosis after pretreatment of the occlusal surface. Materials and Methods: A total of 120 third molars with mild dental fluorosis were randomly divided into 6 groups (n = 20). The tooth surfaces were sealed with an unfilled resin fissure sealant (FS) material. The experimental groups included: 1) phosphoric acid etching (AE) + FS (control); 2) AE + One-Step Plus (OS, Bisco) + FS; 3) bur + AE + FS; 4) bur + AE + OS + FS; 5) Er:YAG laser + AE + FS; and 6) Er:YAG laser + AE + OS + FS. After thermocycling, the teeth were immersed in 0.5% fuchsin and sectioned. Proportions of mircoleakage (PM) and unfilled area (PUA) were measured by digital microscope. Results: Overall, there were significant differences among all groups in the PM (p = 0.00). Group 3 showed the greatest PM, and was significantly different from groups 2 to 6 (p < 0.05). Group 6 showed the lowest PM. Pretreatment with Er:YAG with or without adhesive led to less PM than bur pretreatment. There were no significant differences among groups in PUA. Conclusions: Conventional acid etching provided a similar degree of occlusal seal in teeth with fluorosis compared to those pretreated with a bur or Er:YAG laser. Pretreatment of pits and fissures with Er:YAG in teeth with fluorosis may be an alternative method before fissure sealant application.

A Feasibility Study on the Application of Ferrosilicon By-Product in Concrete to Replace Silica Fume (콘크리트 내 실리카퓸을 대체하기 위한 페로실리콘 산업부산물의 활용 적절성에 대한 연구)

  • Kim, Hansol;Cho, Won Jung;Ann, Ki Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.413-422
    • /
    • 2019
  • A ferrosilicon (FS) by-product was applied into a cementitious binder in concrete substituting the ordinary Portland cement (OPC). The original material characteristic of FS is very identical to silica fume (SF) regarding chemical composition and physical properties such as specific surface area and specific gravity. Therefore, the FS and SF concrete or mortal of which 10% of the material was replaced to total binder weight were fabricated to evaluate the feasibility of using F S as a binder, and the comparative information of OPC, FS and SF concrete was given. The hydration characteristic of FS concrete was analyzed using X-ray diffraction analysis. The FS concrete was beneficial in compressive strength, resistivity against chloride ingress and reducing porosity considering performance of OPC concrete but the advantage was less than using SF. A possibility of alkali-silica expansion was found out from the FS concrete due to the agglomerated size of the silica particles.