• Title/Summary/Keyword: Lens surface

Search Result 610, Processing Time 0.028 seconds

Polarization-Dependent Microlens Array Using Reactive Mesogen Aligned by Top-Down Nanogrooves for Switchable Three-Dimensional Applications

  • Son, Ki-Beom;Kim, Mugeon;Park, Min-Kyu;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.265-271
    • /
    • 2015
  • We propose a reactive mesogen (RM) lens array to obtain good focusing behavior along with a short focal plane, where the focusing behavior is switchable according to the polarization state of incident light. Polarization-dependent focusing behavior is obtained using a planoconvex RM microlens array on a planoconcave isotropic lens template. Even though the sagitta of our RM lens is high, to obtain the short focal length, the RM layer can be aligned well by introducing a top-down alignment effect, using a nanogrooved template. The optical noise due to the $moir{\acute{e}}$ effect generated by the nanogrooves on the surface of the planoconvex RM layer can be removed simply by overcoating a thin RM layer, which is self-aligned by the geometric surface effect, without an additional alignment process. We demonstrate a hexagonal-packed RM lens array that has a very high fill factor and symmetric phase profile, for an ideal lens.

A Study on Improvement of WC Core Surface Roughness by Feedrate Control (Feedrate Control에 의한 초경코어 표면조도 향상에 관한 연구)

  • Kim, Hyun-Uk;Jeong, Sang-Hwa;Lee, Dong-Kil;Kim, Sang-Suk;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Recently, with the increasing lightness and miniaturization of high resolution camera phones, the demand for aspheric glass lens has increased because plastic and spherical lens are unable to satisfy the required performance. An aspheric glass lens is fabricated by the high temperature and pressure molding using a tungsten carbide molding core, so precision grinding technology for the molding core surface are required. This paper reports a development of feedrate control grinding method for aspherical molding core using parallel grinding method. A plane molding core was ground using conventional and feedrate control grinding method. The performance of the feedrate control method was evaluated by measurement of surface roughness. The result indicated that the average surface roughness was reduced to 1.5 nm, which is more efficient than the conventional grinding method.

Manufacture and Analysis of Ophthalmic Polymers including Gold Nanoparticles with Surface Modification Method

  • Seon-Young Park;Su-Mi Shin;A-Young Sung
    • Korean Journal of Materials Research
    • /
    • v.34 no.4
    • /
    • pp.194-201
    • /
    • 2024
  • In this study, the surfaces of two gold nanoparticles of different shapes were modified with hexadecyltrimethylammonium bromide (CTAB) and used for contact lenses. The polymer was based on 2-hydroxyethyl methacrylate (HEMA), and spherical and sea urchin-shaped gold nanoparticles were used as additives. CTAB was used to modify the surface of the sea urchin-shaped gold nanoparticles. To analyze the physical properties of the prepared contact lens, optical transmittance, refractive index, water content, contact angle, and atomic force microscope (AFM) were measured and evaluated. The results showed the nanoparticles did not significantly affect optical transmittance, refractive index, or water content of the lens, and tensile strength increased according to the ratio of the additive. The addition of the sea urchin-shaped nanoparticles resulted in lower wettability compared with the spherical nanoparticles, but somewhat superior tensile strength. In addition, it was found that the wettability of the lens was improved when the surface-modified sea urchin-shaped gold nanoparticles were added. The types of gold nanoparticles and surface modification methods used in this study are considered to have great potential for use in ophthalmic materials.

Further Analysis of FLS 1718+59: A Galaxy-Galaxy Gravitational Lens

  • Taak, Yoon Chan;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.52.1-52.1
    • /
    • 2013
  • We present new analyses of FLS 1718+59, a galaxy-galaxy gravitational lens system in the Spitzer First Look Survey (FLS) Field. A background galaxy (z = 0.245) is severely distorted by a nearby elliptical galaxy (z = 0.08), which can be interpreted as a result of gravitational lensing. We analyze this system by multiple methods, including ELLIPSE fitting, gravitational lens modeling, and surface brightness fitting. From this analysis, we obtain parameters of the lens galaxy using varying approaches and compare them. In the future, we will conduct SED fitting for the lens galaxy and estimate the stellar mass, and compare this with the total mass of the lens to check the M-L relation.

  • PDF

Effect of Particle Contamination on Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RF Signal (CD-ROM 드라이브의 대물렌즈 입자오염이 Laser Diode의 Power와 Photo Diode의 RF Signal에 미치는 영향)

  • Pae, Yang-Il;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1429-1434
    • /
    • 2003
  • A number of dust particles are intruded into ODD(Optical disk drive) due to the flow caused by disk rotation and are adhered to a lens or disk surface. The space between the disk and the lens is being reduced. Someone indicates the problems of this drive that are relatively small data storing capacity and slow access time. In recent, the problems of this optical disk drive mentioned above are being solved by adding the speed of the disk's revolution, making the actuator high-speed or light, and making the beam spot size smaller than making the space narrow between disk and lens. These particle contamination affects seriously RF Signal, readout signal in an ODD. Especially, the affected parts by a particle contamination in an ODD's readout signal are objective lens and media.

  • PDF

A Study on the Machining of Fresnel Lens Mould (Fresnel 렌즈 금형 가공기술 연구)

  • Je, Tae-Jin;Hwang, Gyeong-Hyeon;Lee, Eung-Suk;Kim, Jae-Gu
    • 연구논문집
    • /
    • s.25
    • /
    • pp.105-113
    • /
    • 1995
  • Fresnel lenses are developed for flat optics with the optical characteristics close to aspherical lens such as sharp focusing and dispersion instead of spherical or aspherical surface. Usually, these fresnel lenses and diffraction gratings are machined by high-energy beam such as electron beam machining, but recently with the development of ultra precision machine tool and machining technology, 3-dimension micro machining becomes preferable. This study on the micro machining of fresnel lens is carried out to develop the basic technology of ultra precision micro machining. The machined lens mold will be used for the manufacturing of fresnel lens with 120mm focal distance using synthetic resin material with 1.49 refractive index(PMMA), and the shape of lens is 48mm diameter, $300\mum$ pitch and about $5-700\mum$depth of groove in brass.

  • PDF

A study on searching method of molding condition to control the thickness reduction of optical lens in plastic injection molding process (플라스틱 광학렌즈 사출성형에 있어서 수축 변형량 예측을 위한 사출성형 조건 탐색에 관한 연구)

  • 곽태수;오오모리히토시;배원병
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.27-34
    • /
    • 2004
  • In the injection molding of plastic optical lenses, the molding conditions have critical effects on the quality of the molded lenses. Since there are many molding parameters involved in injection molding process, determination of the molding conditions for lens molding is very important in order to precisely control the surface contours of an optical lens. Therefore this paper presents the application of neural network in suggesting the optimized molding conditions for improving the quality of molded parts based on data of FE Analysis carried out through CAE software, Timon-3D. Suggested model in this paper, which serves to learn from the data of FE Analysis and induce the values for optimized molding conditions. has been implemented for searching the molding conditions without void and with minimized thickness shrinkage at lens center of injection molding optical lens. As the result of this study. we have confirmed that void creation at the inside of lens is primarily determined by mold temperature and thickness shrinkage at center of lens is primarily determined by the parameters such as holding pressure and mold temperature.

A Study of Internal Ultrastructure on the RGP Contact Lens (RGP 콘택트 렌즈의 내부 미세구조에 대한 연구)

  • Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.55-58
    • /
    • 2001
  • The rigid gas permeable(RGP) contact lens has nearly side effect on the cornea. So that, this lens has used the clinical reflective correction of the eye. This study have used several methods for research the fine internal structure on the RGP contact lens by scanning electron microscopy. The results have indicated that the postfixation of 1% $OsO_4$ and tannic acid is responsible for a fine structure in the internal plane of RGP contact lens. These internal surface of contact lens appeared the several shape of the hole of the stereo shape form with arrangement of round form. But, on the contact lens with non-postfixation, the stereo shape have not present and the boundary of the vesicle have not clear. Maybe, these results suggest that the fixation methods have effect on the morphological characters of materials on the RGP contact lens.

  • PDF

Fabrication and Processing Method of Ophthalmic Hydrogel Tinted Lens Containing Indium Tin Oxide-Composited Materials

  • Lee, Min-Jae;Lee, Kyung-Mun;Sung, A-Young
    • Korean Journal of Materials Research
    • /
    • v.28 no.12
    • /
    • pp.685-690
    • /
    • 2018
  • In this study, a multifunctional ophthalmic lens material with an electromagnetic shielding effect, high oxygen permeability, and high water content is tested, and its applicability is evaluated. Metal oxide nanoparticles are applied to the ophthalmic lens material for vision correction to shield harmful electromagnetic waves; the pyridine group is used to improve the antibacterial effect; and silicone substituted with urethane and acrylate is employed to increase the oxygen permeability and water content. In addition, multifunctional tinted ophthalmic lens materials are studied using lens materials with an excellent antibacterial effect (2,6-difluoropyridine, 2-fluoro-4-pyridinecarboxylic acid) and functional (UV protection, high wettability) lens materials (2,4-dihydroxy benzophenone, 2-hydroxy-4-(methacryloyloxy)benzophenone). To solve problems such as air bubbles generated during the polymerization process for the manufacturing and turbidity of the lens surface, polymerization conditions in which the defect rate is minimized are determined. The results show that the polymerization temperature and time are most appropriate when they are $110^{\circ}C$ and 40 minutes, respectively. The optimum injection amount of the polymerization solution is 350 ms. The turbid phenomenon that appears in lens processing is improved by 10 to 95 % according to the test time and conditions.

The Effect of Circle Contact Lens on the Stability of Tear Film (써클콘택트렌즈가 눈물막 안정성에 미치는 영향)

  • Lee, Sehee;Hyung, Sung Min;Koh, Seung Hwan;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.125-131
    • /
    • 2015
  • Purpose: The effect of pigmentation in circle contact lens on lens wearers' tear film stability was investigated in this study. Methods: Non-invasive tear film break-up times of 54 normal eyes before and after lens wearing in twenties and the portion of first tear breakup were measured. The frontal and back surface roughness of circle contact lens was further observed with a scanning electron microscope. The clear lens which was made of hilafilcon B and circle contact lenses which were made of hilafilcon B, polymacon and copolymer of HEMA NVP were tested. Results: Non-invasive tear film breakup time was significantly reduced compared with it before lens wearing. In some case, statistically significant difference in tear film breakup time was also observed between circle contact lenses. The tear file break-up was usually early started in lower than upper portion, and in temporal than nasal portion although there was variation in the lens material. The tear film break-up of circle contact lenses made of hilafilcon B was more commonly observed in peripheral portion(pigmented area) compared with clear contact lens made of same material. Conclusions: The present study revealed that the stability of tear film was affected by wearing circle contact lens and the result seems to be used as the basis for the problem solving that can occur due to the pigmentation when wearing circle contact lens.