Novel Telecentric Collimator Design for Mobile Optical Inspection Instruments

  • Hojong Choi;Seongil Cho;Jaemyung Ryu
    • Current Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.263-272
    • /
    • 2023
  • A collimator refers to an optical system that images a collimated beam at a desired point. A resolution target located at a near distance can be converted into a virtual image located at a long distance. To test the resolution for mobile cameras, a large target is placed at a long distance. If a collimator system is used, the target can be placed at a near distance. The space required for a resolution inspection can thus be drastically reduced. However, to inspect a mobile camera, the exit pupil of the collimator system and the entrance pupil of the mobile camera must match, and the stop of the collimator system must be located on the last surface. Because a collimator system cannot be symmetrical with respect to the stop, the distortion becomes extremely large, which can be corrected by combining the collimator symmetrically with respect to the object plane. A novel system was designed to inspect an optical lens on a mobile phone. After arranging the refractive power, lenses were added using the equivalent lens design method. The distortion was reduced to less than 1%. This optical system satisfies a half-field angle of 45° and an optical performance sufficient for inspection.

Out-of-plane Deformation Measurement of Spherical Glasses Lens Using ESPI (ESPI를 이용한 구면 안경렌즈의 면외 변형 측정)

  • Yang, Seung-Pill;Kim, Kyoung-Suk;Jang, Ho-Sub;Kim, Hyun-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.77-81
    • /
    • 2007
  • The spherical lens is typically classified by the refractive power into two groups such as (+) diopter lens and (-) diopter lens. The deformation occurred by the external force that is applied to a lens is caused by the increase or the decrease in the diopter of a lens. In this paper, the deformation of the lens was quantitatively measured by using ESPI (Electronic Speckle Pattern Interferometry) which have been used in the optical measurement field for past few years. ESPI has an advantage that the deformation of an object can be measured precisely by using coherence of the light. The experiment was carried out to the totally 16 types of plastic lens. It was confirmed that the deformation was decreased by increasing the diopter of the lens when same displacement was applied to the lens in case of (+) diopter lens and was increased by decreasing the diopter of the lens in case of (-) diopter lens. Also, it was found that the deformation of (+) diopter lens is less than that of (-) diopter lens. Therefore, with these results, it is expected that the possibility of the quantitative measurement for variation of the optical defect caused by the deformation of a lens when the deformation is occurred to the various types of the lens can be presented and that the application in the lens industrial field can be performed.

  • PDF

Evaluation of scale accuracy and effect of off-the-visual-axis on schematic retinoscope training eye (검영기 훈련 모형안의 굴절상태 눈금과 벗어난 시축의 평가)

  • Ryu, Dong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3789-3793
    • /
    • 2010
  • To investigate accuracy of graduated scale of schematic retinoscope training eye(schematic eye) and induced effect when measured at off-axis from visual axis. Two skilled retinoscopist measured refractive power using retinoscope in random order. Seven schematic eyes from a single manufacturer were recruited and set to mark +4.00 to -6 diopter(+4, +3, +2, +1, 0, -1, -2, -3, -4, -5, -6). After introducing +2.00 diopter trial lens(50cm working lens), neutral distance was measured at 180 degree to estimate accuracy of scale, and refractive power measured at 0, 5, 10, 15 and 20 degree off-axis to see if any error was induced. According to the results measured by two specialists, in six of seven schematic eye, scale setting varied (p<0.05) and measured refractive power at 5, 10, 15 and 20 degree off-axis from visual axis were $-0.13{\pm}0.06$, $-0.29{\pm}0.06$, $-0.58{\pm}0.11$, and $-0.83{\pm}0.16$ diopter respectively. In some schematic eye, scale graduated on the schematic eye and scale measured by retinoscopy could be different and if retinoscopy is performed off-axis from visual axis, any measuring error can be caused.

The Evaluation of Reliability for Exam Distance of Visual Acuity (시력검사거리에 따른 원거리 시력검사 신뢰성 평가)

  • Chun, Young-Yun;Choi, Hyun-Soo;Park, Seong-Jong;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • Purpose: We aimed to evaluate reliability of eye exam for visual acuity as a function of distance. Methods: There were 39 patients (78 eyes) who had visual acuity 1.0 or more at 5 meters. We measured refractive power of patients at each distances, 5 meters, 4 meters and 3 meters. Automatic chart (LCD-700, Hyeseong Optic. Co., Korea) used for visual acuity, skiascope (Beta 200, Heine, Germany) and auto refractometer (RK-5, Canon, Japan) used as for objective refraction. Accommodation was examined by minus lens addition methods, and Accommodative lag was examined by grid chart for reading distance. Results: Being compared to 3 meter test, Amount of corrected spherical refractive power decreased by $0.10{\pm}0.38$ D, astigmatism decreased by $0.05{\pm}0.10$ D, and axis of astigmatism rotated toward to temporal by $2.64{\pm}18.75$ degrees for right eyes, by $11.43{\pm}48.55$ degrees for left eyes in case of 5 meter test. Changes of corrected refraction and astigmatism were slightly correlated (r=-0.31, r=-0.29). Conclusions: Because corrected refraction power and amount of astigmatism decreased and axis of astigmatism tends to turn the temporal direction according to exam distance, examination distance of visual acuity should improved as to 5 meters.

Analysis of Addition Power for New Wearer of Progressive Addition Lenses (누진렌즈 안경 처음 착용자의 가입도 분석)

  • Joo, Seok-Hee;Shim, Hyun-Suk;Shim, Jun-Beom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.247-251
    • /
    • 2013
  • Purpose: To analyse the addition power of new wearer of progressive addition lenses. Methods: Data of 636 subjects who have been prescribed progressive addition lenses as the first time were used for analyse. The range of age for was between 41~78 years old and they visited the optical practice in Gwangju metropolitan city from 2001 to 2013Date of refractive state, gender and age were analysed. Results: The difference of addition by gender was 1.71 D in male and 1.67 D in women. The difference of addition by refractive error was 1.67 D in emmetropic patients and 1.74 D in myopic patients, 1.90 D in hyperopic patients. The difference of addition by age was1.26 D in 41~44 years old sge group, 1.48 D in 45~49 years old age group,1.72 D in 50~54 years old age group 1.84 D in 55~59 years old age group, 2.10 D in 60~64 years old age group and 2.43 D in over 65 years old age group. The difference of addition by diopter in myopic patients was 1.58 D in low myopic patients and 1.48 D in middle myopic patients, 1.67 D in high myopic patients. The difference of addition by axis of astigmatism was 1.80 D in with-the-rule astigmatism, 1.64 D in against-the-rule astigmatism and 1.65 D in oblique astigmatism. Conclusions: The Addition power of progressive lenses were different according to the types of refractive error, astigmatism axis and age.

Optical Evaluation of MR8 Material spectacle Lens with a New Method for the Analysis of Blue Light (새로운 청광 분석법을 적용한 MR8 안경재료의 광학적 시험 평가)

  • Kim, Ha-Rim;Jeong, Ju-Hyun
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.413-420
    • /
    • 2018
  • Purpose : We present a novel method for the analysis of blue light applied by the analysis method of David L. with optical experiment and blue light by measuring the transmittance by dividing it by the refractive power in the spectacle lens made by MR8. Methods : The lenses of -8.00D, -7.00D, -6.00D, -5.00D, -4.00D, -3.00D, and 0.00D manufactured by MR8 being sold in the market, were selected. The transmittance was measured at the intervals of 5 nm from 200 to 1000 nm with UV-VIS Spectrophotometers (SolidSpec 3700), and they were in range of the blue light (380 to 500 nm) analyzed by a David L.'s analysis method. Results : All of the MR8 lenses selected for this study almost completely blocked at the UV range. A lens of -8.00D was measured as the lowest transmittance of 59.56% in the blue light area and low values were measured at the blue areas 1 and 2 according to the analysis of David L.In the infrared ray area, the transmittance of all lenses gradually decreased. The average value of the luminous transmittance was 23.67% ~ 26.33% and then gradually decreased from -4.00D. Conclusion : Applying the analysis of David L., a minimum of 41.28% and a maximum of 46.60% were measured at the blue light 1 area and a minimum of 87.30% and a maximum of 97.55% were measured at the blue light 2 area. A minimum of 86.83% and a maximum of 96.55% were measured at the blue light 3 area, and the average was 94%. The luminous transmittance of the -3.00D lens was 26.33%, which was the highest, and that -8.00D was 23.67%, which was the lowest.

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

Refractive Error Induced by Combined Phacotrabeculectomy (섬유주절제술과 백내장 병합수술 후 굴절력 오차의 분석)

  • Lee, Jun Seok;Lee, Chong Eun;Park, Ji Hae;Seo, Sam;Lee, Kyoo Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1173-1180
    • /
    • 2018
  • Purpose: We evaluated the postoperative accuracy of intraocular lens power prediction for patients undergoing phacotrabeculectomy and identified preoperative factors associated with refractive outcome in those with primary open-angle glaucoma (POAG). Methods: We retrospectively reviewed the medical records of 27 patients who underwent phacotrabeculectomy to treat POAG. We recorded all discrepancies between predicted and actual postoperative refractions. We compared the data to those of an age- and sex-matched control group that underwent uncomplicated cataract surgery during the same time period. Preoperative factors associated with the mean absolute error (MAE) were identified via multivariate regression analyses. Results: The mean refractive error of the 27 eyes that underwent phacotrabeculectomy was comparable to that of the 27 eyes treated via phacoemulsification (+0.02 vs. -0.01 D, p = 0.802). The phacotrabeculectomy group exhibited a significantly higher MAE (0.65 vs. 0.35 D, p = 0.035) and more postoperative astigmatism (-1.07 vs. -0.66 D, p = 0.020) than the phacoemulsification group. The preoperative anterior chamber depth (ACD) and the changes in the postoperative intraocular pressure (IOP) were significantly associated with a greater MAE after phacotrabeculectomy. Conclusions: POAG treatment via combined phacoemulsification/trabeculectomy was associated with greater error in terms of final refraction prediction, and more postoperative astigmatism. As both a shallow preoperative ACD and a greater postoperative change in IOP appear to increase the predictive error, these two factors should be considered when planning phacotrabeculectomy.

Assessment of UV Blocking Performance for Development of Converged Technologies of Vision Correcting Spectacle Lenses (시력교정용 안경렌즈의 융복합적 기술개발을 위한 UV차단 성능 평가)

  • Kim, Heung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.93-98
    • /
    • 2018
  • This study was wanted to confirm ability for UV blocking according to its material. The lenses materials were Acryl, CR-39, NK-55, and MR-8. It was grouped: Group A consisting of anti-scratch hard coated lenses and anti-refractive multi coated lenses, Group B added UV blocking coating on the group A, and Group C consisting of only UV blocking lenses. The results measured UV transmittance, On the UV-A wavelength, Group A showed the UV transmittance of 7.726%, 0.043%, 0.007%, and 0.007% respectively. Group B showed 0.038%, 0.037%, 0.007%, and 0.007%, respectively. The UV-blocking performance of CR-39 has been greatly improved. Group C has shown the best UV blocking function; only 0.005% and 0.004% of UV transmittances.(1.60 and 1.67 index of refraction respectively). For the low power of lenses and sunglasses, the CR-39 lens is the most used. Therefore, to UV blocking from the lens, new materials or UV absorbers or UV coating technology and development of Converged Technologies are required.

Study of Ocular Optical Components (안구의 광학적 구조에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.139-144
    • /
    • 2000
  • In this study, anterior corneal radius of curvature in korean subjects aged between 16 to 79 year-olds were measured using a keratometer. Refractive power was also measured without cyloplegia. A-mode Ultrasonography was used to measure anterior chamber depth, crystalline lens thickness, vitreous chamber depth & axial length. Measurements of anterior chamber depth of subjects in their 20s were between 3.0 mm & 4.0 mm, 70s age group were between 2 mm & 3.50 mm, showing a decrease with age. Crystalline lens thickness of 20s age group was 2.64 mm while 70s age group was 4.62 mm showing an increase with age. Vitreous chamber depth, unaffected by age, was about 17 mm. Axial length was 24.47 mm in subjects below 40s age groups decreasing to 24.11 mm in above 40s age groups. Corneal radius of curvature was 7.79 mm and 7.72 mm in younger and older age groups respectively, showing a decrease with age.