• Title/Summary/Keyword: Lens refractive power

Search Result 65, Processing Time 0.027 seconds

Comparison of Progressive Addition Lenses Standards (누진 가입도 렌즈의 규격 비교)

  • Moon, Byeong-Yeon;Paik, Sun-Mok;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: To improve the quality of Korean progressive addition lenses, we measured the optical and geometrical elements of them and evaluated their qualities. Methods: We have measured the refractive power, the thickness at optical center and prism power for home and foreign progressive addition lenses which were distributed in the domestic market, and then have done a comparative analysis according to international standards. Results: The qualities of Korean progressive addition lens were on an equal footing with famous foreign brand products, but they were out of tolerance in a few cases. Conclusions: The careful attention is required to progressive addition lens, therefore, it is considered that more precise quality control is an essential element to strength the competitiveness of Korean products in the world market.

  • PDF

Relationship between Surface Sag Error and Optical Power of Progressive Addition Lens

  • Liu, Zhiying;Li, Dan
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.538-543
    • /
    • 2017
  • Progressive addition lenses (PAL) have very wide application in the modern glasses market. The unique progressive surface can make a lens have progressive refractive power, which can meet the human eye's different needs for distance-vision and near-vision. According to the national glasses fabrication standard, the difference between actual optical power after fabrication and nominal design value should be less than 0.1D over the lens effective area. The optical power distribution of PAL is determined directly by the surface. Consequently, the surface processing accuracy requirement is proposed. Beginning from the surface expressions of progressive addition lenses, the relationship equations between the surface sag and optical power distribution are derived. They are demonstrated through tolerance analysis and test of an example progressive addition lens with addition of 2.09D (5.46D-7.55D). The example addition surface is fabricated under given accuracy by a single-point diamond ultra-precision machine. The optical power of the PAL example is tested with a focal-meter after fabrication. The optical power addition difference between test result and design nominal value is 0.09D, which is less than 0.1D. The derived relationship between the surface error and optical power is verified from the PAL example simulation and test result. It can provide theoretical tolerance analysis proof for the PAL surface fabricating process.

Study on the Development of Wet Cell Holder for the Measurement of Hydrophilic Contact Lens (친수성 콘택트렌즈 측정용 Wet Cell 홀더 개발에 관한 연구)

  • Song, Kyoung-Sek;Lim, Hyeon-Sun;Joo, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.455-462
    • /
    • 2015
  • Purpose: To develop more accurate wet measuring system combining the wet cell, automatic lensmeter and the related software for hydrophilic contact lenses and to verify the accuracy of those measuring holder system already available in the market. Methods: Refractive power measurement were done in both a conventional method which has been commonly used in optical shops and a new method which is recently developed in korea. Hydrophilic contact lens of korean brand was chosen as a test material and was tested by water content ratio and by spherical refractive power. Results: When spherical power of -3.00 D contact lens is measured in the newly developed wet cell measurement holder with automatic lensmeter, it reads -3.01 D at water content ratio of 38%. -3.00 D at 45% and -2.98 D at 58%. The same experiment with the Poster soft contact lens wet cell measurement holder maintaining other conditions same resulted in -3.60 D at the water content ratio of 38%, -3.06 D at 45% and -2.46 D at 58%. Conclusions: At the higher water content, the refractive power values measured by both of the wet cell measuring holders are shown lower, and additionally, the new method using the wet cell holder and new software program in a automatic lensmeter showed more accurate readings than conventional Poster soft contact lens wet cell measuring system.

The Research of the 2nd Lens Design for Wide Angle Distribution (광 확산용 2차 렌즈 설계 기술 연구)

  • Joo, Won-Don;Oh, Sang-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.1-7
    • /
    • 2012
  • Recently an optical diffusion of LED lamps has been studied actively. In this paper, the second lens applied to a cover of the LED lamp was analytically designed to having a wide angle distribution of light without diffuser characteristic by dispersing agent. In this process, We found a major factors that can help improve the performance of the lens. It is the refractive power of the lens, the Mie particle density of phosphor, and the arrangement of the LED. Through the final simulation, we can see the LED lamp is possible to get wide angle light distribution by proper source modeling and second lens designing. Also, we can see this simulated results are entirely consistent with measured data for light distribution. In this research, we present the shape of the second lens with wide angle distribution and derive the important factors for the second lens design.

A Study of a Correction Effect of Astigmatism using Spherical RGP Lens (근시성 난시안에서 구면 RGP 콘택트렌즈의 난시교정 효과)

  • Ju, Seok-Hui;Park, Hae-Jung;Shin, Chul-Gun;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.85-89
    • /
    • 2003
  • A tear lens formed by between back surface of spherical rigid gas permeable(RGP) contact lens and front surface of cornea shows an excellent correction effect of astigmatism. To study an effects of tear lens power using spherical RGP lens and therefore to utilize them in clinical procedures, we analyze a change of the total astigmatism, the cornea astigmatism, and the residual astigmatism, we derive the following conclusion. 1. Almost all refractive astigmatism below than 2.00D present fully corrected. Thereby resulting good visual acuity. Refractive astigmatism higher than 2.50D show under-corrected and apparent decrease of visual acuity if it is higher than 3.00D. 2. Amount of corneal astigmatism below than 2.50D show acceptable under-corrected while higher than 3.000 present unacceptable visual acuity. 3. An estimated residual astigmatism is not revealed as it is : but it is reduced when it incorporate to refractive astigmatism.

  • PDF

The Relationship between Refractive Myopia and Corneal Astigmatism in Korea Women University Students (한국 여자대학생의 굴절성 근시와 각막난시 관계)

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose. To analysis the prevalence of the myopia and corneal astigmatism in Korea women university students. Methods. From August 2011 to December 2012, one hundreds subjects were performed in refraction test using the Auto-Keratometry. Results. The mean age of the 100 subjects (200 eyes) was $21.23{\pm}2.34$. The mean spherical refractive power was -$1.78{\pm}1.65$(OD) and -$1.83{\pm}1.67$(OS) Diopter. The mean astigmatism power was $1.22{\pm}0.96$ (OD) and $1.27{\pm}0.91$ (OS). The mean corneal astigmatism was $1.44{\pm}0.81$(OD) and $1.55{\pm}0.93$(OS). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5%. There was a statistical significance between right eye and left eye in the spherical equivalent power(p=0.002). Also there was a statistical significance between spherical power and refractive astigmatism in OD(p=0.006) and OS(0.003) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.0003). However, there was not a statistical significance between spherical power and corneal astigmatism in OD(p=0.08) and OS(0.1) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.48). Conclusions. In this study, these results suggested that the analysis of the refractive myopia and corneal astigmatism can provide the visual correct and useful diagnosis information for the eyewear dispensing, contact lens fitting and corneal refraction surgery.

  • PDF

Applied Spherical Lens with Reflect Mirror for the CPV module (반사판 적용 구형렌즈를 갖는 집광형 태양전지모듈)

  • Lee, Kang-Yeon;Jeong, Byeong-Ho;Kim, Hyo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.83-90
    • /
    • 2011
  • There are two main types of concentrating optical systems in use today: refractive types that use Fresnel lenses, and reflective systems that use one or more mirrors. Regardless of the chosen optical system, the result is concentrated sunlight being aimed at the sensitive face of the cell, to produce more energy from less photovoltaic material. In this paper, for the achieve trackerless CPV system, CPV module included that the spherical lens with reflect mirror makes it possible to achieve high and stable power generation performance for the high concentration photovoltaic power generation system and cope with the needs for a variety of shapes and sizes in flexible manners and that the multiple cavity assemble method greatly reduces costs. Development of these high performance multi-junction CPV module promises to accelerate growth in photovoltaic power generation.

Study of the Axial Length/Corneal Radius Ratio in Determining the Refractive State of the Eye (굴절이상과 안축장/각막곡률반경 비와의 관계에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.23-31
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between axial length/corneal radius ratio and refractive error for human eye. Ocular components were measured Baush & Lomb keratometer, Holden-Payor pachometer, and Stoz Compuscan. Refractive error was measured by subjective refraction. The results were as follows; 1) Spherical equivalent refractive error and axial length/corneal radius ratio was very highly correlated with the correlation coefficient for -0.89. 2) Axial length/corneal radius ratio and axial length, vitreous chamber depth were highly correlated that the correlation coefficients were 0.82, 0.80 respectively. 3) Axial length/corneal radius ratio and anterior chamber depth, corneal power, corneal radius, lens power were correlated with the correlation coefficients for 0.57, 0.40, -0.39, -0.35 respectively. 4) There were no significant correlation between axial length/corneal radius ratio and lens thickness, and corneal thickness.

  • PDF

Design of a Catadioptric System with Corrected Color Aberration and Flat Petzval Curvature Using a Graphically Symmetric Method

  • Lim, Tae-Yeon;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.324-331
    • /
    • 2018
  • This paper describes a symmetric method for determining a combination of element power and optical material to design a catadioptric system with corrected color aberration and flat Petzval curvature. To graphically obtain the solutions, a glass chart containing the Abbe number, the refractive index, and the optical power, which are closely related to these aberrations, is suggested. First, we recompose an optical system as a doublet of the specific lens and an equivalent single lens, and then locate both lenses on lines that are symmetric to each other on a glass chart, through changing the lens parameters effectively. Utilizing this method, an achromatic catadioptric system with flat Petzval curvature is obtained.