• Title/Summary/Keyword: Lens diameter

Search Result 170, Processing Time 0.022 seconds

Diameter of the retinal blur circle in a artificial hypermetropia (인워적 원시에 따른 망막에서 착란원 크기)

  • Choi, Woon Sang;Kim, Yoon-Kyung;Oh, Heung Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.145-149
    • /
    • 2005
  • In a artificial hypermetropia with the accommodative response, we investigated a diameter of blur circle as a function of test lens refractive power. In a schematic eye model of the hypermetropia, the second focal length along to accommodated power of the crystal lens are calculated as a function of test lens power and, also distance between the retina and exit pupil are calculated as a function of accommodated power. As these results are compared, the size of blur circle on the retina are obtained.

  • PDF

A study on the fabrication method of middle size LGP using continuous micro-lenses made by LIGA reflow

  • Kim, Jong-Sun;Ko, Young-Bae;Hwang, Chul-Jin;Kim, Jong-Deok;Yoon, Kyung-Hwan
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.3
    • /
    • pp.171-176
    • /
    • 2007
  • LCD-BLU (Liquid Crystal Display-Back Light Unit) of medium size is usually manufactured by forming numerous dots with $50{\sim}300\;{\mu}m$ in diameter by etching process and V-grove shape with $50\;{\mu}m$ in height by mechanical cutting process. However, the surface of the etched dots is very rough due to the characteristics of the etching process and V-cutting needs rather high cost. Instead of existing optical pattern made by etching and mechanical cutting, 3-dimensional continuous micro-lens of $200\;{\mu}m$ in diameter was applied in the present study. The continuous micro-lens pattern fabricated by modified LIGA with thermal reflow process was tested to this new optical design of LGP. The manufacturing process using LIGA-reflow is made up of three stages as follows: (i) the stage of lithography, (ii) the stage of thermal reflow process and (iii) the stage of electroplating. The continuous micro-lens patterned LGP was fabricated with injection molding and its test results showed the possibility of commercial use in the future.

Performance evaluation by simulation for the angular luminous intensity distributions of marine lanterns using a tilting aspherical Fresnel lens and a C-8 type light bulb (기울어진 비구면 프레넬 렌즈와 C-8 type 전구를 이용한 해상용 랜턴의 배광곡선 시뮬레이션을 통한 성능평가)

  • Cho Hyun Seok;Jo Jae Heung;Park Seungl Nam;Park Chul Woung;Kim Yong Wan;Kim Jong Tae
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.511-518
    • /
    • 2004
  • Providing marine signal lanterns with advantages of little weight as well as large aperture, a Fresnel lens has been adopted to transfer the beam from the lanterns up to 10 nautical miles (18.53 km). A Fresnel lens with the diameter of 250 mm and 300 mm was designed by a lens design program and optimized by adjusting the groove parameters of the lens. The angular luminous intensity distribution (ALID) of this lens was calculated by using an illumination analysis program considering the ALID of a light bulb. At the best alignment of the bulb, the maximum luminous intensities (MLI) of the lantern were 1000 cd (in the case of 250 mm diameter) and 1300 cd (in the case of 300 mm diameter). These are more than the critical value of 720 cd that is the Korean Standard of MLI for the marine lantern. The ALID was investigated as a function of misalignment from the lens focus to determine the tolerance of the alignment ranges.

Variable-focus Liquid Lens Based on a Laterally-integrated Thermopneumatic Actuator

  • Lee, June Kyoo;Park, Kyung-Woo;Lim, Geunbae;Kim, Hak-Rin;Kong, Seong Ho
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.22-28
    • /
    • 2012
  • We report a focal-length tunable liquid lens based on thermopneumatically driven fluidic pressure. The fluidic pressure is generated by deformation of an elastomeric diaphragm induced by thermopneumaticity from a laterally integrated microheater sealed within an air chamber. The pressure is transmitted by a confined liquid to a lens diaphragm through an internal fluid channel. The liquid filling under the lens diaphragm functions as a liquid lens for dynamic focusing with properties depending on the curvature of the deformed diaphragm. The diaphragm area of the air chamber is designed five times larger than that of the lens cavity to yield high focal-length tunability by amplified deflection of the lens diaphragm. With our method, we achieved excellent focal-length tunability from infinity (without an input current) to 4 mm (with an input current of 12 mA) with a lens aperture diameter of 2 mm.

Design of an Endoscopic Microscope Objective Lens Composed of Flexible Fiber Bundle and Gradient-index with a High Resolution and a Minimally-Invasive Outer Diameter (광섬유 다발과 Gradient-index Lens가 결합된 고 분해능 및 최소침습 직경의 공초점 내시 현미경 대물렌즈의 설계)

  • Jang, Sun-Young;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.87-94
    • /
    • 2008
  • We present a new design for an endoscope objective lens composed of a lexible fiber bundle with 30,000 core, and a gradient-index (GRIN) objective lens with an optical adaptor. The characteristic of this objective lens is to be minimally-invasive to be able to insert easily in the internal organs of live animals. The GRIN lens has a small diameter and a very simple construction, which is selected with the diameter of 1.0 mm and numerical aperture of 0.5 to achieve a minimally-invasive outer diameter and a high resolution. The resultant designed lens shows the performance as follows; a lateral resolution of 1.63 um and diameters of 100% encircled energy of $0.3\;{\mu}m$ and $0.83\;{\mu}m$ for the on-axis and the off-axis image point, respectively. Also, we can present a cheap solution with a lateral resolution of 1.74 um and diameters of 100% encircled energy of $1.10\;{\mu}m$ and $2.84\;{\mu}m$ for the on-axis and the off-axis image point, respectively.

Evaluation of a Aluminum Hyperbolic Mirror with the Diameter of 300 mm(f/1.98) by Using the Autostigmatic Null Lens System Assembled in a Fixed Tube Mount (경통고정식 자동무수차점 널 렌즈 테스트법을 이용한 직경 300 mm(f/1.98) 알루미늄 쌍곡면 거울의 형상측정)

  • Lee, Young-Hun;Jo, Jae-Heung;Rim, Cheon-Seog;Yang, Sun-Choel;Kim, Geon-Hee;Won, Jong-Ho;Jeong, Youn-Hong
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.412-419
    • /
    • 2006
  • We design and fabricate an autostigmatic null lens system assembled in a fixed tube mount in order to evaluate the shape of an aluminum hyperbolic mirror with the diameter of 300 mm and the f-number of 1.98, which is fabricated by a high precision aspherical DTM (diamond turning machine). Also, we evaluate the degree of shape of the aspherical mirror by this autostigmatic null lens testing method. The autostigmatic null lens system assembling in a fixed tube mount has several advantages of light weight, good mechanical stability, etc. The permissible fabricating limits of null lenses and a mount are determined by considering various tolerances to assure the measurement reliability.

Design of an Endoscopic Microscope Objective Composed of GRIN(Gradient-Index) Lens with Scanning Devices (GRIN 렌즈로 구성된 주사방식의 내시현미경 대물렌즈의 설계)

  • Kim, Keyong-Jeong;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.311-318
    • /
    • 2009
  • We present an attractive real time in-vivo endoscopic microscope with a resolution of submicron, in which two kinds of optical correcting plates are inserted to eliminate higher order spherical aberration and field curvature. And, since the conventional objective lens is replaced to GRIN lenses with diameter of 1 mm, the above endoscopic microscope can be effectively utilized to invade minimally for live animals.

Effect of Hydrogel lens and Silicone-Hydrogel lens on Corneal thickness (하이드로겔 렌즈와 실리콘-하이드로겔 렌즈가 각막 두께에 미치는 영향)

  • Seo, Jung-Ick
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.4
    • /
    • pp.1021-1025
    • /
    • 2017
  • Purpose: Changes in corneal thickness after wearing hydrogel lens and silicone-hydrogel lens with different oxygen transmission rates wew syudied. Methods: Experiments were performed on 11 subjects(22 eyes). corneal thickness was measured after wearing contact lenses for 8 hours. Corneal thickness was measured using ORB Scan II(ver. 3.14) Results: In the results of the corneal thickness measurement by direction, in the case of the hydrogel-tor lens, the center thickness was $33.63{\mu}m$, the nasal was $34.29{\mu}m$, the temporal was $27.17{\mu}m$, the inferior was $27.17{\mu}m$, the superior was $18.90{\mu}m$, and change rates were 6.28%, 5.71%, 5.40%, 4.75% and 3.09%, respectively. In the results of the corneal thickness measurement by diameter, in the case of the hydrogel-tor lens, the center was $33.63{\mu}m$, the mid-peripheral was $28.19{\mu}m$, the peripheral was $24.18{\mu}m$, and change rates were 6.28%, 4.76%, and 3.79%, respectively. Conclusions: The hydrogel lenses with relatively low oxygen transmission rates resulted in a significant increase in thickness over the entire cornea compared to silicon-hydrogel lenses with high oxygen transmission rates.

Design of an Optical System for Iris Photographing (홍채 촬영용 광학계 설계)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.39-44
    • /
    • 2009
  • Purpose: To design a mini optical system photographing the iris, which is used in the iridology. Methods: We designed a mini optical system photographing the iris by using the Sigma 2000 design program. Results: We designed a mini optical system photographing the iris, which is suitable in the CCD using a micro actuator for auto-focusing, of which characteristics have the TCL of 30 mm, a magnification of -0.65, about 8.0 mm distance from the 1st lens to the last lens, the max barrel diameter of 11 mm, and about 1 mm of the effective stop diameter. Also the resolution line width of this system is characterised by 92 lps/mm at the 30% MTF value criterion. Conclusions: By designing an optical system of which characteristics have the TCL of 30 mm, about 8.0 mm distance from the 1st lens to the last lens, the max barrel diameter of 11 mm, and the resolution line width of $5.4{\mu}m$ at the 30% MTF value criterion, we could miniaturize the iris photographing optical system.

  • PDF

Design of a Rod-Type Aspheric Lens Collimator for Optical Telecommunication (막대 형태의 비구면 렌즈를 이용한 광통신용 시준기의 설계)

  • Kang, Seok-Bong;Kang, Eun-Kyoung;HwangBo, Chang-Kwon;Kang, Sang-Do;Kim, Jong-Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • A rod-type aspheric lens collimator for the optical telecommunication system which shows high coupling efficiency and experiences small coupling loss for misalignment errors is designed. The working distance, thickness, and diameter of the rod-type aspheric lens are determined to be close to those of the GRIN lens collimator in order to replace the GRIN lens with the rod-type aspheric lens. Since the coupling loss mainly originated from the spherical aberration of the lens, the spherical aberration in the rod-type aspheric lens is reduced drastically, and it turns out that the coupling efficiency of the rod-type aspheric lens collimator is higher than that of the available collimators, such as ball lens, GRIN lens, and C-type lens collimators.