• Title/Summary/Keyword: Length Dimension

Search Result 665, Processing Time 0.027 seconds

Quantification of Pediatric Cervical Growth : Anatomical Changes in the Sub-Axial Spine

  • Lee, Ho Jin;Lee, Jung Jae;Hong, Jae Taek;Kim, Jong Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.3
    • /
    • pp.185-191
    • /
    • 2015
  • Objective : In order to provide normal values of the pediatric sub-axial cervical spinal canal and vertebral body growth pattern using computed tomographic scans, a total of 318 patients less than 10 years old were included. Methods : The growth of the vertebral body and canal space was investigated using four different age groups. The Torg ratio (TR) was calculated and all patients were classified into a low TR group and a high TR group according to a cutoff value of 1.0. To account for spinal curvature, the C3-7 angle was measured. Results : Very little axial expansion and growth in height were observed (2.9 mm and 3.4 mm, respectively), and the spinal canal increments (1.8 mm) were much smaller than the dimensions of the vertebral body. The mean TR values were $1.03{\pm}0.14$ at the C3 vertebral level, $1.02{\pm}0.13$ at C4, $1.05{\pm}0.13$ at C5, $1.04{\pm}0.13$ at C6, and $1.02{\pm}0.12$ at C7 in all patients. The mean sub-axial angle (C3-7) was $7.9{\pm}10.6^{\circ}$ (range: $-17-47^{\circ}$). Conclusion : The upper sub-axial spinal canal continuously increased in size compared to the lower sub-axial spine after 8 years of age. Considerable decrements in the TR was found after late childhood compared to younger ages. Generally, there were no significant differences between boys and girls in vertical length of the cervical vertebrae. However, the axial dimension of the vertebral body and the spinal canal space varied according to gender.

A FINITE ELEMENT ANALYSIS OF THE CENTER OF RESISTANCE OF A MAXILLARY FIRST MOLAR (상악 제일대구치의 저항중심에 관한 유한요소법적 분석)

  • Cho, Jeong-Hyeon;Lee, Ki-Soo;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.263-273
    • /
    • 1993
  • The purpose of this study was to analyse the center of resistance of the maxillary first molar using the 3-dimension finite element method. An extracted maxillary first molar of normal shape and average root length was selected and sectioned every 1.5mm parallel to the cementoenamel junction. Each section was traced and digitized to construct 3-D finite element model of the maxillary first molar. After a certain magnitude of counterbalancing moment(M) was applied to the tooth, a varying single force(F) of distomesial direction was applied to a certain point of th tooth until the tooth was translated. The force producing translation(Ft) was substituted to the equation ${\Delta}d=M/Ft$ to calculate the center of resistance of the maxillary first molar. And reducing the alveolar bone level 1.68mm, and 3.36mm below to the cementoenamel junction, the tooth movement was analysed to see the effect of reducing the alveolar bone level to the location of the center of resistance. The results were as follows ; 1. The center of resistance of the maxillary first molar was 3.72mm apical, 1.10mm buccal, and 0.71mm mesial to the geometric center of the horizontally sectioned surface at the cementoenamel junction. This point was 0.36mm apical, 1.20mm buccal, and 0.71mm mesial to the trifurcation point, indicating that it was not on the tooth root. 2. As the alveolar bone level was reduced, the center of resistance of the maxillary first molar was moved to the apical direction.

  • PDF

Effects of the long-term use of maxillary protraction facemasks with skeletal anchorage on pharyngeal airway dimensions in growing patients with cleft lip and palate

  • Kim, Jung-Eun;Yim, Sunjin;Choi, Jin-Young;Kim, Sukwha;Kim, Su-Jung;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.50 no.4
    • /
    • pp.238-248
    • /
    • 2020
  • Objective: To investigate the effects of the long-term use of a maxillary protraction facemask with miniplate (FM-MP) on pharyngeal airway dimensions in growing patients with cleft lip and palate (CLP). Methods: The study included 24 boys with CLP (mean age, 12.2 years; mean duration of FM-MP therapy, 4.9 years), divided into two groups according to the amount of A point advancement to the vertical reference plane (VRP): Group 1, > 4 mm; Group 2, < 2 mm; n = 12/group. After evaluating the skeletodental and airway variables using lateral cephalograms acquired before and after FM-MP therapy, statistical analyses were performed. Results: Group 1 showed greater forward and downward displacements of the posterior maxilla (posterior nasal spine [PNS]-horizontal reference plane [HRP]; PNS-VRP), greater increase in ANB, more forward tongue position (tongue tip-Pt vertical line to Frankfort horizontal plane), and greater increase in the oropharynx (superior posterior airway space [SPAS]; middle airway space [MAS]) and upper nasopharynx (PNS-adenoid2) than did Group 2. While maxillary advancement (A-VRP and PNS-VRP) correlated with increases in SPAS, MAS, and PNS-adenoid2, downward displacement of the PNS (PNS-HRP) correlated with increases in SPAS, MAS, PNS-adenoid1, and PNS-adenoid2, and with a decrease in vertical airway length (VAL). Mandibular forward displacement and decrease in mandibular plane correlated with increases in MAS. Conclusions: FM-MP therapy had positive effects on the oropharyngeal and nasopharyngeal airway spaces without increases in VAL in Group 1 rather than in Group 2. However, further validation using an untreated control group is necessary.

Compact Dual-band Double Dipole Quasi-Yagi Antenna with V-shaped Ground Plane (V-모양 접지면을 가지는 소형 이중 대역 이중 다이폴 준-야기 안테나)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.436-441
    • /
    • 2018
  • In this paper, a design method for a compact double dipole quasi-Yagi antenna with a V-shaped ground plane operating in dual bands including 2.45 GHz and 5 GHz wireless LAN frequency bands is studied. First, a quasi-Yagi antenna operating in the 2.45 GHz band is designed, and a V-shaped ground plane is used instead of a conventional strip ground plane to reduce the length of the antenna. A second dipole is connected to the dipole driver of the quasi-Yagi antenna for 2.45 GHz band and a director is appended for 5 GHz band operation. A prototype of the proposed dual-band antenna operating at 2.45 GHz WLAN band and 4.57-7.11 GHz band is fabricated on an FR4 substrate with a dimension of 40 mm by 55 mm. Fabricated antenna shows frequency bands of 2.33-2.75 GHz and 4.38-7.5 GHz for a voltage standing wave ratio less than 2. Measured gain remains more than 4 dBi in both bands.

Predictions of Fouling Phenomena in the Axial Compressor of Gas Turbine Using an Analytic Method (해석적 방법을 이용한 가스터빈 축류 압축기의 파울링 현상 해석)

  • Song, Tae-Won;Kim, Dong-Seop;Kim, Jae-Hwan;Son, Jeong-Rak;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1721-1729
    • /
    • 2001
  • The performance of gas turbines is decreased as their operating hours increase. Fouling in the axial compressor is one of main reasons for the performance degradation of gas turbine. Airborne particles entering with air at the inlet into compressor adhere to the blade surface and result in the change of the blade shape, which is closely and sensitively related to the compressor performance. It is difficult to exactly analyze the mechanism of the compressor fouling because the growing process of the fouling is very slow and the dimension of the fouled depth on the blade surface is very small compared with blade dimensions. In this study, an improved analytic method to predict the motion of particles in compressor cascades and their deposition onto blade is proposed. Simulations using proposed method and their comparison with field data demonstrate the feasibility of the model. It if found that some important parameters such as chord length, solidity and number of stages, which represent the characteristics of compressor geometry, are closely related to the fouling phenomena. And, the particle sloe and patterns of their distributions are also Important factors to predict the fouling phenomena in the axial compressor of the gas turbine.

Impact Fracture Behavior of Ceramic Plates Instrumented Long Bar (계장화한 긴 바를 사용한 세라믹판의 충격 파괴 거동)

  • Shin, Hyung-Seop;Bae, Young-Jun;Oh, Sang-Yeob;Kim, Chang-Uk;Chang, Soon-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.561-566
    • /
    • 2001
  • A long bar impact test to alumina plates(AD 85 and AD 90) was carried out by using fabricated impact testing apparatus. The apparatus adopting a long bar of 2.1m in length made it possible to measure directly the applied impact force to the specimen during bar impact. The dimension of specimens was $33{\times}33mm$ and thickness was 3.4mm. Confinement of D2=18mm outer diameter and D1=10.5mm inner diameter was used to provide contact pressure to the specimen. Contact pressure of p=100 or 200MPa was applied to specimen before impact test. Damage caused in those cases were compared with the case of without contact pressure. The damage of specimen was different depending upon the pressure level of confinement. The existence of confinement had suppressed the development of radial cracks from the bottom of specimen and reduced the extent of damage as compared with cases without contact pressure(p=0MPa). Because the application of contact pressure to the specimen increased the apparent flexural stiffness of specimen during bar impact, it had produced the change of developed damage in the specimen; from the radial cracks to the local contact stress dominant damage. It would contribute to the improvement of the ballistic property in ceramic plates.

  • PDF

Analysis of Relation between Conduction Path and Threshold Voltages of Double Gate MOSFET (이중게이트 MOSFET의 전도중심과 문턱전압의 관계 분석)

  • Jung, Hakkee;Han, Jihyung;Lee, Jongin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.818-821
    • /
    • 2012
  • This paper have analyzed the change of threshold voltage for conduction path of double gate(DG) MOSFET. The threshold voltage roll-off among the short channel effects of DGMOSFET have become obstacles of precise device operation. The analytical solution of Poisson's equation have been used to analyze the threshold voltage, and Gaussian function been used as carrier distribution to analyze closely for experimental results. The threshold voltages for conduction path have been analyzed for device parameters such as channel length, channel thickness, gate oxide thickness and doping concentration. Since this potential model has been verified in the previous papers, we have used this model to analyze the threshold voltage. Resultly, we know the threshold voltage is greatly influenced on the change of conduction path for device parameters of DGMOSFET.

  • PDF

Analysis of Relation between Conduction Path and Breakdown Voltages of Double Gate MOSFET (DGMOSFET의 전도중심과 항복전압의 관계 분석)

  • Jung, Hakkee;Han, Jihyung;Kwon, Ohshin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.825-828
    • /
    • 2012
  • This paper have analyzed the change of breakdown voltage for conduction path of double gate(DG) MOSFET. The low breakdown voltage among the short channel effects of DGMOSFET have become obstacles of device operation. The analytical solution of Poisson's equation have been used to analyze the breakdown voltage, and Gaussian function been used as carrier distribution to analyze closely for experimental results. The change of breakdown voltages for conduction path have been analyzed for device parameters such as channel length, channel thickness, gate oxide thickness and doping concentration. Since this potential model has been verified in the previous papers, we have used this model to analyze the breakdown voltage. Resultly, we know the breakdown voltage is greatly influenced on the change of conduction path for device parameters of DGMOSFET.

  • PDF

A 8192-Point FFT Processor Based on the CORDIC Algorithm for OFDM System (CORDIC 알고리듬에 기반 한 OFDM 시스템용 8192-Point FFT 프로세서)

  • Park, Sang-Yoon;Cho, Nam-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.8B
    • /
    • pp.787-795
    • /
    • 2002
  • This paper presents the architecture and the implementation of a 2K/4K/8K-point complex Fast Fourier Transform(FFT) processor for Orthogonal Frequency-Division Multiplexing (OFDM) system. The architecture is based on the Cooley-Tukey algorithm for decomposing the long DFT into short length multi-dimensional DFTs. The transposition memory, shuffle memory, and memory mergence method are used for the efficient manipulation of data for multi-dimensional transforms. Booth algorithm and the COordinate Rotation DIgital Computer(CORDIC) processor are employed for the twiddle factor multiplications in each dimension. Also, for the CORDIC processor, a new twiddle factor generation method is proposed to obviate the ROM required for storing the twiddle factors. The overall 2K/4K/8K-FFT processor requires 600,000 gates, and it is implemented in 1.8 V, 0.18 ${\mu}m$ CMOS. The processor can perform 8K-point FFT in every 273 ${\mu}s$, 2K-point every 68.26 ${\mu}s$ at 30MHz, and the SNR is over 48dB, which are enough performances for the OFDM in DVB-T.

Deduction of TWCs and Internal Wavelengths Needed for a Design of Asynchronous OPS System with Shared or Output FDL Buffer (공유형 혹은 아웃풋 광 지연 선로 버퍼를 갖는 비동기 광패킷 스위칭 시스템 설계를 위해 필요한 가변 파장 변환기 및 내부 파장 개수의 도출)

  • Lim, Huhnkuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.2
    • /
    • pp.86-94
    • /
    • 2014
  • Optical packet switching (OPS) is being considered as one of the switching technologies for a future optical internet. For contention resolution in an optical packet switching (OPS) system, the wavelength dimension is generally used in combination with a fiber delay line (FDL) buffer. In this article, we propose a method to reduce the number of tunable wavelength converters (TWCs) by sharing TWCs for a cost-effective design of an asynchronous OPS system with a shared or an output FDL buffer. Asynchronous and variable-length packets are considered in the OPS system design. To investigate the number of TWCs needed for the OPS system, an algorithm is proposed, which searches for an available TWC and an unused internal wavelength, as well as an outgoing channel. This algorithm is applied to an OPS system with a shared or an output FDL buffer. Also, the number of internal wavelengths (i.e., the conversion range of the TWC) needed for an asynchronous OPS system is presented for cost reduction of the OPS system.